CHAPTER 2 ND-45669 (E) Pag e 5 4 Revision 2.0 INFORMATION FOR DATA PROGRAMMING Single Digit Dialing 20 0 – 3 F/808 – 811 21 0 – 3 F/S 41 0 13/S Table 2-7 List of Commands for Each Hotel/Motel Feature (Continued) For Hotel/Motel SystemF: First Data S : Second Data — : No Data FEATURECOMMAND 1S T DATA/2N D DATA (F/S)REMARKS CODE Y-YYY
ND -4 5669 ( E) CHAPTER 2 IN FORM ATION FO R DATA PR O GRAMM ING INI TIAL AP INI TIAL Syste m F eat ure s (2) A P OFF LIN E
CHAPTER 2 ND-45669 (E) Pag e 5 6 Revision 2.0 INFORMATION FOR DATA PROGRAMMING (2) When deleting data in any command, enter “CCC” as 2nd data. However, data in the following commands cannot be deleted. • Commands where the initial data ( ) is provided but the initial data ( ) is “NONE”. • CM29, CM41, CM42, CM60 YY = 30. 4.2 Method of Setting On-Line/Off-Line Mode (1) For the MP card: (a) Operation for changing on-line mode to off-line mode: • Set SW3 to “2” or “3”. • Press SW1. (b) Operation for changing off-line mode to on-line mode: • Set SW3 to “0”. • Press SW1. For details, refer to the Circuit Card Manual. (2) For the AP card: (a) Operation of changing on-line mode to off-line mode: • Set SW1 as shown below. SW1 OFF 4 3 2 1 ON : POSITION TO BE SET
ND-45669 (E) CHAPTER 2 Page 57 Revision 2.0 INFORMATION FOR DATA PROGRAMMING (b) Operation for changing off-line mode to on-line mode: • Set SW1 as shown below. For details, refer to the Circuit Card Manual. 4.3 Method for Installing Line/Trunk Cards In the PBX, all line/trunk circuits are provided by installing the cards into a card shelf. The PBX employs a flexible port assignment architecture in which the system allocates a port (Time Slot) to each LEN (Line Equipment Number) according to system data. Consider the following conditions before installing cards: • Number of Time Slots within Unit • Card installation location (1) Number of Time Slots Figure 2-2 Line/Trunk Card Installation Location SW1 OFF 4 3 2 1 ON : POSITION TO BE SET L T 0 0L T 0 1L T 0 2L T 0 3L T 0 4L T 0 5L T 0 6L T 0 7L T 0 8L T 0 9L T 1 0L T 1 1L T 1 2L T 1 3L T 1 4L T 1 5A P 6M P / F P / A P 7B U S / A P 8 P W R BUILT-IN BATTERY * PIM 0 - 7 * Application cards can be mounted also in LT10 through LT15 slots.
CHAPTER 2 ND-45669 (E) Page 58 Addendum-001 Revision 2.1 AUGUST, 1998 INFORMATION FOR DATA PROGRAMMING • Number of ports on each card Each card slot has four (4) LENs. For the relation between Slot Numbers and LENs, refer to the “Port Assignment Table” of the Office Data Programming Manual. Note:When performing the 10-party conference, two PN-CFTA cards are needed. In this case, the total num- ber of time slots is 20. • The following two conditions should be considered for the PBX: Table 2-9 Port Assignment on Each Line/Trunk Card X: Assignment possible –: Assignment not possible CARD NAMELEN TO BE ASSIGNED ON EACH LTXX NUMBER OF CIRCUITS NUMBER OF TIME SLOTS LEVEL 0 LEVEL 1 LEVEL 2 LEVEL 3 PN-4COT XXXX 4 4 PN-4LC XXXX 4 4 PN-4DLC XXXX 4 4 PN-2DLC X X – – 2 2 PN-2DATA X–X– 2 2 PN-2ODT X X – – 2 2 PN-8RSTA X–X– 8 8 PN-AUCA X X – – 2 2 PN-CFTA X – – – 8 10 PN-DK00 X – X – 8 0 PN-TNTA X – X – 2 4 PN-2DPCB X–X– 2 2 PN-2AMPA X–X– 2 4 PN-2ILCA X X – – 2 5 Number of time slots within any PIMs (0 - 7) £ 64 time slots Number of time slots per System £ 512 time slots
ND -4 5669 ( E) CHAPTER 2 IN FORM ATION FO R DATA PR O GRAMM ING + 03 + + Pa ssword L ev el N o. + + P asswo rd + STDEDEEXE + 03 + + 9 + + CC CC CCC C + STDEDEEXE 8 dig its
CHAPTER 2 ND-45669 (E) Pag e 6 0 Revision 2.0 This page is for your notes.
ND-45669 (E) CHAPTER 3 Page 61 Revision 2.0 DESCRIPTION OF COMMANDS CHAPTER 3 DESCRIPTION OF COMMANDS 1. GENERAL This chapter provides a detailed description for each command. 2. DETAILED DESCRIPTION OF COMMANDS This section describes the methods for programming commands. Information about each command is present- ed in the following order: (1) Function: The function of the command. (2) Precaution: Precautions related to assigning data. (3) Assignment Procedure: The procedure for assigning data. (4) Data Table: A detailed description of the data. In the description of each command, initial data which is automatically loaded into memory, after system ini- tialization (using position “B” on SW3 of the MP, followed by a reset) is indicated with “ ”. Refer to Chap- ter 4 for details on default data when the automatic resident program function (using position “C” on SW3 of the MP, followed by a reset) is used. The installer should confirm the meaning of initial data, and change or delete the data, if required. If under the command code designation there is an abbreviation, then programming can be accomplished by the MAT mode of programming instead of the MOC mode or CAT mode. MAT
CHAPTER 3 ND-45669 (E) Page 62 Addendum-002 Revision 2.2 JANUARY, 1999 CM00 COMMAND CODE TITLE: SYSTEM DATA MEMORY ALL CLEAR 00 [CM00] System Data Memory All Clear 4. DATA TABLE: 1. FUNCTION: This command confirms that the system data memory (RAM) area can be Written-in /Read-out and also assigns the Initial Data to the RAM area. 2. PRECAUTION: (1) This command can only be used in off-line mode. (2) When this command is executed, “OK” displays with Memory Clear completed (about 30 seconds later). (3) If an error exists in memory, “WD ERROR” displays. (4) This command is not available with a CAT. To clear all system data, set SW3 to “B”, and press SW1 on the MP card. In this case, the only functional port is LEN0000, which is assigned as a CAT. 3. ASSIGNMENT PROCEDURE: 1ST DATA 2ND DATA DATA MEANING DATA MEANING 1 System data memory all clear CCC Clear 3 System data clear for new memory area Note:This data is available when using PN-CP00-C/CP02-C/CP03-C card.CCC Clear +00+ + ++ +CCC MEMORY AREA EXESTDEDE DESIGNATION (1/3)
ND-45669 (E) CHAPTER 3 Pag e 63 Revision 2.0 CM01 COMMAND CODE TITLE: SYSTEM DATA MEMORY PARTIAL CLEAR 01 4. DATA TABLE: 1. FUNCTION: This command is used to clear the data associated with the Numbering Plan (CM20-CM29) or Toll Restriction (CM85-CM8A). 2. PRECAUTION: This command can only be used in off-line mode. 3. ASSIGNMENT PROCEDURE: CLEAR DESIGNATIONSYSTEM DATA TO BE CLEARED REMARKS 20 CM20: Assignment of Numbering Plan CM21: Assignment of Single Digit Access Code CM22: Assignment of Route Advance CM23: Assignment of Tenant Development CM24: Assignment of Kind of Calling Terminal Development CM25: Assignment of Kind of Special Terminal Development CM26: Assignment of Closed Number CM29: Assignment of Numbering Plan Tenant Group 80 CM85: Assignment of Maximum Number of Digits on C.O. Call CM88: Assignment of Dialed Digit requiring an automatic pause CM8A: Assignment of LCR/Toll Restriction Development Table 740 Clears Guest Name memory area +01+ + + + +CCC 80 Commands to be cleared: 20, 21, 22, 23, 24, 25, 26 and 29 in Data Memory Commands to be cleared: 85, 88 and 8A in Data MemoryEXESTDEDE +01+ + + + +CCC 20EXE STDEDE +01+ + + + +CCC 740EXE STDEDE [CM01] System Data Memory Partial Clear