CHAPTER 3 ND-45669 (E) Page 172 Addendum-001 Revision 2.1 AUGUST, 1998 CM35 COMMAND CODE TITLE: TRUNK ROUTE DATA 35 MAT : Initial Data YY/YYY SETTING DATA RELATED COMMAND No. MEANING DATA MEANING 87 Distinctive Ringing by detect- ing the ringing signal from the Main PBX (or Centrex).0 1 To provide Not provided Note 1:When this function is utilized, be sure to set Trunk Line Appearance as the terminat- ing method (CM30 YY = 02, 03, set for 02). Note 2:Tone Ringer is selected by CM35 YY = 34; lamp control is set by CM35 YY = 32.CM30 YY = 02, 03 CM30 YY = 18 89 (CRCD)Cyclic Redundancy Checking for DTI Trunk0 1 To provide Not provided 90 (SPFA)Assignment of Special Facilities0 1 2 3 4 5 6 7 No. 7 CCIS Not used Basic Rate Interface ISDN-Primary Rate Interface Not used PBX-PBX Interface Not used 91 (CCH7)Assignment of Common Channel Handler (CCH) Number used for No. 7 CCIS0 3CCH 0 CCH 3CM06 YY = 07 CMA7, A8 92 (CDTI)Assignment of Digital Data Transmission via DDI/No. 7 CCIS0 1 2 3 4 5 6 7 Digital Data Transmission (48 Kbps) Digital Data Transmission (56 Kbps) Digital Data Transmission (64 Kbps) Reversal of F & S Bits Not used Data Transmission via Modem 93 (DCHI)Assignment of D Channel Handler (DCH) Number00 04 15 DCH 0 DCH 4 Not usedCM06 YY=08 ~~ ~~ [CM35] Trunk Route Data
ND-45669 (E) CHAPTER 3 Addendum-001 Page 173 AUGUST, 1998 Revision 2.1 CM35 COMMAND CODE TITLE: TRUNK ROUTE DATA 35 MAT 97 Assignment of route-class data in CCIS Route to Route RestrictionXX Assignment data is the same as CM12 YY=01 98 Designated seizure of trunks for Private Lines0 1 Allow RestrictedCM12 YY=16 CM42-08 100 Assignment of Terminating Impedance for C.O. line00 01 02 14600 ohm (for regular/long line) Balanced Network Imp.: complex 900 ohm Balanced Network Imp.: complex 600 ohm (for short line/behind PBX) Balanced Network Imp.: 600 ohm 2-wire E&M Trunk 104 Polarity of 2-wire E&M/ 4-wire E&M Trunk (PN-2ODT)1 2 3 E wire M wire Open Open Ground Battery Ground Ground 105 Purpose of 2-wire E&M/ 4-wire E&M Trunk (PN-2ODT)Note 80 1 2-wire E&M Trunk 4-wire E&M Trunk 113 LAPD Mode of D channel Route0 1 Network mode User mode 117 Forced disconnect of tandem connection for incoming trunk0 1 Allow Not allowedCM08-029 127 Whether virtual tie line is re- leased when there are no calls for predetermined time0 1 Released Not released 129 Sending method of calling number from/to network0 1 3 7 Caller ID (CLASS) T1-ANI Enhanced 911 MFC-R2 : Initial Data YY/YYY SETTING DATA RELATED COMMAND No. MEANING DATA MEANING X X Night Trunk Restriction class Day Trunk Restriction class INITIAL AP INITIAL
CHAPTER 3 ND-45669 (E) Page 174 Addendum-001 Revision 2.1 AUGUST, 1998 CM35 COMMAND CODE TITLE: TRUNK ROUTE DATA 35 MAT 135 Kind of trunk route for voice channel and common signal- ing channel0 1 Event Based CCIS Route Other Trunk Route 138 Sending of received ANI information from network to VMS with MCI0 1 To send Not sent 139 Roaming Service assignment for Virtual COT route0 1 Available Not availableCM30 YY=00 140 Roaming Service 0 1 Available Not available 141 Pursuit function after roaming PS0 1 Provide Not provided 142 Protocol type between PBXs 1 7Q931 a-Digital None 143 Method for corresponding of virtual trunks numbers be- tween the offices on Event Based CCIS0 1 By Sub-address No. By dialed-in digits 146 Trunk ID code assigned by CM30 YY=19 displays on Multiline Terminal LCD0 1 Available Not available (Calling/Called Sub address is displayed.)CM30 YY=19 : Initial Data YY/YYY SETTING DATA RELATED COMMAND No. MEANING DATA MEANING AP INITIAL
ND-45669 (E) CHAPTER 3 Addendum-001 Page 174-1 AUGUST, 1998 Revision 2.1 CM35 COMMAND CODE TITLE: TRUNK ROUTE DATA 35 MAT Note 1:In case of CM35 YY = 76, Data = 15, not specified (release the sender by time out or by answer signal from the called distant office). In case of CM35 YY = 76, Data = 00 – 04, specified by the dialed digits assigned by CM85. Note 2:STN means the calling party’s station number, and this number is sent automatically by CM30 – 28, Data = x6. Note 3:LED indication for an internal incoming call is red (120 IPM flashing). For indicating the ter- mination of transferred external incoming call, the flashing LED color depends on CM08-137. Note 4:For incoming calls to a Trunk-Direct Appearance key on Multiline Terminal, the special ringing; 0.2 sec. ON – 0.2 sec. OFF is applied. Note 5:Maximum number digit analysis should be provided to prevent one way calls (See CM35 YY = 76, CM85 and CM8A YYY = 400 – 407). Note 6:When the Trunk Route is assigned as a C.O. line, the data for YY = 56, 57 and 58 are automati- cally set to “Restricted”. Note 7:When the Trunk Route is assigned as a C.O. line, the data for YY = 68 is automatically set to “Restricted”. Note 8:Both circuits must be set as either 2-wire or 4-wire in one PN-2ODT card; they cannot be both. [CM35] Trunk Route Data
THIS PAGE INTENTIONALLY LEFT BLANK. CHAPTER 3 ND-45669 (E) Page 174-2 Addendum-001 Revision 2.1 AUGUST, 1998 This page is for your notes.
ND-45669 (E) CHAPTER 3 Pag e 1 75 Revision 2.0 CM36 COMMAND CODE TITLE: RESTRICTION DATA FOR TANDEM CONNECTION 36 4. DATA TABLE: Note:The 2-digit Incoming Trunk Route number and the 2-digit Outgoing Trunk Route number are entered as a concatenated 4-digit number. For example, the value “1824” would represent Incoming Trunk Route “18” and Outgoing Trunk Route 24. 1. FUNCTION: This command is used to define restriction data for tandem connection within a system, for each combi- nation of an incoming trunk route and an outgoing trunk route. 2. PRECAUTION: Any incoming Trunk Route assigned to “No release signal” in CM35 YY=05, is restricted from tandem connection. 3. ASSIGNMENT PROCEDURE: : Initial Data INCOMING CALL TRUNK ROUTEOUTGOING TRUNK ROUTESETTING DATA RELATED COMMAND DATA MEANING 00 6300 630 1 Allowed RestrictedCM35 YY = 05 ST+36+DE+ + +DE+ +EXEINCOMING TRUNK ROUTE (2 Digits)OUTGOING TRUNK ROUTE (2 Digits)D ATA (0/1) Note ~~ [CM36] Restriction Data for Tandem Connection
CHAPTER 3 ND-45669 (E) Pag e 1 76 Revision 2.0 CM38 COMMAND CODE TITLE: AMP TRUNK 38 4. DATA TABLE: 1. FUNCTION: This command is used to define the AMP Trunk controlled data. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: : Initial Data YYINCOMING/OUTGOING TRUNK ROUTE NO. AMP PATTERN NO.SETTING DATA RELATED COMMAND DATA MEANING 00 00 14 15AMP Pattern Number 00 AMP Pattern Number 14 Not use the AMP Trunk 01 AMP Pattern Number 00 AMP Pattern Number 14Assignment of gain value Fixed Gain 0 : 12dB 1 : 8dB 2 : 4dB 3 : 0dB AGC(Automatic Gain Control) 0 : 0 dbr 1 : +4dbr 2 : -4dbr 3 : Through (Assigned by Fixed Gain) 02 0 1Echo Canceller Function Through Normal or AMP PATTERN NUMBER(4 digits or 2 digits) ST INCOMING/OUTGOING TRUNK ROUTE DE + EXE 38YY ++ + DATA (1-2 digits) +DE + Outgoing Trunk Route No. Incoming Trunk Route No. XX XX ~~ ~ X X [CM38] AMP Trunk
ND-45669 (E) CHAPTER 3 Pag e 1 77 Revision 2.0 CM38 COMMAND CODE TITLE: AMP TRUNK 38 Note:CM38 YY=07 setting data 0 is effective except ISDN and CCIS lines. 03 AMP Pattern Number 00 AMP Pattern Number 140 1Echo Canceller Gain Controller ON OFF 04 AMP Pattern Number 00 AMP Pattern Number 140 1Mode Selection of Tone Disabler G164 G165 05 AMP Pattern Number 00 AMP Pattern Number 140 1Detect Time of Tone Disabler 0 sec. 2 sec. 06 AMP Pattern Number 00 AMP Pattern Number 140 1Channel to be connected Incoming Route : Tie Line Outgoing Route : C.O. Line Incoming Route : C.O. Line Outgoing Route : Tie Line 07 AMP Pattern Number 00 AMP Pattern Number 140 1Timing of AMP Trunk connection When dialing is finished Note When answering : Initial Data YYINCOMING/OUTGOING TRUNK ROUTE NO. AMP PATTERN NO.SETTING DATA RELATED COMMAND DATA MEANING ~ ~ ~ ~ ~
CHAPTER 3 ND-45669 (E) Pag e 1 78 Revision 2.0 CM40 COMMAND CODE TITLE: FUNCTION OF RS-232C INTERFACE CIRCUIT 40 1. FUNCTION: This command is used to assign the function of the RS-232C interface circuits, mounted on the MP card. The MP card has two RS-232C interface circuits, which are used for the following purposes: (1) PN-CP00/PN-CP00-B (2) PN-CP03 (a) When using Built-in SMDR (b) When not using Built-in SMDR 2. PRECAUTION: None PORT LOCATION NUMBERPURPOSES CONNECTOR Port 0 Local MAT D-SUB connector on the back wiring board (BWB). Port 1 Remote Maintenance using external MODEM or built- in MODEM of the MP card.RS connector on the MP card PORT LOCATION NUMBERPURPOSES CONNECTOR Port 0 Built-in SMDR RS connector on the MP card Port 1 Local MAT or Remote Maintenance using external MODEM or built-in MODEM of the MP card.RS connector on the MP card PORT LOCATION NUMBERPURPOSES CONNECTOR Port 0 Local MAT RS connector on the MP card Port 1 Remote Maintenance using external MODEM or built- in MODEM of the MP card.RS connector on the MP card [CM40] Function of RS-232C Interface Circuit
ND-45669 (E) CHAPTER 3 CM 40 4. DATA T ABL E: 3. ASSIG NM EN T P R O CEDUR E: DATAPO RT LO CAT IO N NU MBERD E + 40Y Y+ + ++DE EXE+