    INFORMATION FOR DATA PROGRAMMING
    Table 2-6  List of Commands for Each Business Feature (Continued)
    For Business SystemF:  First Data
    S:  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/ 2ND DATA
    (F/S)REMARKS
    CODE Y-YYY
    • Ring Frequency Control 08 – 262, 390/S
    12 07 F/S
    15 83, 84 F/S
    35 34 F/S
    • Soft Key 12 12, 23
    90 00 F/F1091
    9A 00-03, 10-
    13F/S
    • Volume Control – – –
    Remote Hold 12 02 F/S
    15 124 F/S
    41 0 06/S
    90 00 F/F1010
    Remote Maintenance – – –
    Reserve Power – – –
    Resident System Program – – – See Chapter 4.
    Return Message Schedule Display 08 – 334
    12 02 F/S
    15 19 F/1
    20 0 – 3 F/A54, 023
    Ringing Line Pickup 12 07 F/S
    15 82, 86 F/0
    Route Advance 20 0 – 3 F/200 – 231
    22 00 – 31 F/S
    Save and Repeat 90 00 F/F1001, F1013, F1014
    Security Alarm 12 03 F/04
    52 00 – 99 F/S
    Six-/Ten-Party Conference 10 – F/ED00 – ED03
    12 02, 05 F/S
    15 69 F/1
    20 0 – 3 F/A59 – A62
    90 00 F/F0A85, F0A86 
    						
    							CHAPTER 2 ND-45669 (E)
    Pag e 4 6
    Revision 2.0
    INFORMATION FOR DATA PROGRAMMING
    Software Line Appearance 11 – F/S
    12 01 – 14 F/S
    13 12, 13 F/1
    90 00 F/S
    Stack Dial 08 – 178/S
    12 07 F/S
    15 96 F/S
    90 00 F/F1000, F6121
    Station Hunting – – –
    • Station Hunting - Circular 08 – 240/S
    18 0, 1 F/S
    • Station Hunting - Terminal 08 – 240/S
    18 0, 1 F/S
    • Station Hunting - Secretarial 08 – 240/S
    18 2 F/S
    19 0, 1, 2 F/S
    Station Message Detail Recording Refer to SMDR System 
    Manual.
    Station Speed Dialing 05 – F/19
    08 – 035, 168, 171, 252/S
    12 02 F/S
    15 07 F/1
    20 0 - 3 F/064 - 066
    73 – F/S
    74 – F/S
    90 00 F/S
    94 – F/S
    CMD000 – 56/1 Table 2-6  List of Commands for Each Business Feature (Continued)
    For Business SystemF:  First Data
    S :  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/2N D DATA
    (F/S)REMARKS
    CODE Y-YYY 
    						
    							ND-45669 (E) CHAPTER 2
    Page 47
    Revision 2.0
    INFORMATION FOR DATA PROGRAMMING
    Step Call 08 – 069, 163/1, 208/0
    Supervisory Control of Peripheral 
    Equipment13 22 F/0
    41 1 08/S
    System Speed Dialing 08 – 043, 044, 110 - 112, 176/S
    12 02 F/S
    15 06 F/1
    20 0 - 3 F/067, 068, A50 - A52
    41 0 38/S
    71 – 00 - 64/S
    72 – F/S
    74 – F/S
    Tenant Service 12 04 F/S
    20 0 - 3 F/S
    23 00 - 23 F/S
    29 – F/S
    30 01 F/S
    49 01 - 07 F/S
    51 00 - 12/15 F/S
    61 00 F/S
    62 0 - 3 F/S
    63 0 - 2 F/S
    64 0 F/S
    65 50/51 F/S
    71 – F/S
    8A 100 F/S
    Tie Line Tandem Switching 36 – F/S
    Timed Queue 41 0 35 – 37/S
    90 00 F/F004 Table 2-6  List of Commands for Each Business Feature (Continued)
    For Business SystemF:  First Data
    S :  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/2N D DATA
    (F/S)REMARKS
    CODE Y-YYY 
    						
    							CHAPTER 2 ND-45669 (E)
    Pag e 4 8
    Revision 2.0
    INFORMATION FOR DATA PROGRAMMING
    Timed Reminder 08 – 228/S
    10 – F/DB00, E8XX, EBXXX
    12 02 F/S
    15 13 F/1
    20 0 - 3 F/024, 025, A00 – A02
    41 0 23, 52/S
    42 – 03, 04/S
    44 – F/0100
    48 1 00/0200, 0500, 1400
    49 00, 08 F/S
    90 00 F/F0024
    Trunk-Direct Appearances 08 – 365/S
    30 02, 18 F/S
    90 00 F/D000 – D255/F0058
    Trunk Queuing - Outgoing 08 – 196/S
    12 02 F/S
    15 02 F/1
    20 0 – 3 F/000, 001, 004, 005
    35 28 F/S
    90 00 F/F0004
    Trunk-to-Trunk Connection 08 – 028, 029/S
    10 – F/C100-C163
    12 07 F/S
    15 90, 91 F/1
    35 119 F/S
    36 – F/S
    38 00–07 F/S
    41 0 54, 55/S Table 2-6  List of Commands for Each Business Feature (Continued)
    For Business SystemF:  First Data
    S :  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/2N D DATA
    (F/S)REMARKS
    CODE Y-YYY 
    						
    							ND-45669 (E) CHAPTER 2
    Page 49
    Revision 2.0
    INFORMATION FOR DATA PROGRAMMING
    Uniform Call Distribution (UCD) 
    with Overflow08 – 212, 214, 215, 227, 259, 357, 
    442/S
    10 – F/S
    12 02 F/S
    15 33, 103, 
    104F/1
    17 0 – 2, 
    4 – 7, A, BF/S
    20 0 – 3 F/033, 044, 045, A00 – A02
    35 18, 60 F/S
    41 0 16, 47/S
    42 – 15, 16/S
    44 – F/S
    49 00 F/S
    51 17 F/S
    59 – 00/S
    76 6 F/S
    90 00 F/F0033, F0044, F1020, 
    F1280 – 1295
    Uniform Numbering – Voice & Data 20 0 - 3 F/A26 - A29
    35 17 F/S
    50 00 0/S
    80 – 0/2
    8A A00,
    405 - 407, 
    000 - 063, 
    500 - 755F/S
    Variable Timing Parameters 41 0, 1, 2 F/STable 2-6  List of Commands for Each Business Feature (Continued)
    For Business SystemF:  First Data
    S :  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/2N D DATA
    (F/S)REMARKS
    CODE Y-YYY 
    						
    							CHAPTER 2 ND-45669 (E)
    Page 50 Addendum-002
    Revision 2.2 JANUARY, 1999
    INFORMATION FOR DATA PROGRAMMING
    Table 2-6  List of Commands for Each Business Feature (Continued)
    For Business SystemF:  First Data
    S :  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/2N D DATA
    (F/S)REMARKS
    CODE Y-YYY
    Vo i c e  G u i d e 1 5 1 1 6 F / S
    41 0 95/S
    48 2 12, 13, 14/S
    49 00, 13 F/S
    Voice Mail Integration 08 – 063, 156, 208, 333, 428/S
    12 02 F/S
    13 03, 10, 13 F/S
    15 24, 40 F/1
    20 0 – 3 F/040, 041, A46, A47
    41 0 00, 14, 44, 48, 49/S
    50 00 3, 4/S
    51 15, 18 F/S
    77 0, 1 F/S
    90 00 F/F1005, F5001, F6112, 
    F6113, F6123
    Whisper Page 08 – 268, 269/S
    12 02 F/S
    15 111, 112 F/S
    20 0 – 3 F/A88
    48 2 17/S
    90 00 F/F0A88
    Wireless Communication System 
    (WCS)– – – Refer to WCS System 
    Manual 
    						
    							ND-45669 (E) CHAPTER 2
    Page 51
    Revision 2.0
    INFORMATION FOR DATA PROGRAMMING
    Table 2-7  List of Commands for Each Hotel/Motel Feature
    For Hotel/Motel SystemF:  First Data
    S :  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/2N D DATA
    (F/S)REMARKS
    CODE Y-YYY
    Automatic Wake-Up 08 – 228, 282 – 284, 286, 
    287/S
    10 – F/S
    12 02 F/S
    15 13, 20, 21, 
    33F/1
    20 0 – 3 F/024, 025, 027, 028, 
    A00 – A02
    41 0 23, 52/S
    42 – 03, 04/S
    44 – F/0100
    48 1 00/XX00
    49 00, 08 F/S
    90 – F/S
    Check In/Check Out D000 – 11/1
    D001 – 12, 13/S
    D015 – F/S
    D016 – XX06/1
    D031 – F/S
    Direct Data Entry 20 0 – 3 F/097
    90 00 F/F0097
    D001 – 252, 253/S
    D015 – F/S
    D016 – XX24/S 
    						
    							CHAPTER 2 ND-45669 (E)
    Pag e 5 2
    Revision 2.0
    INFORMATION FOR DATA PROGRAMMING
    Do Not Disturb 08 – 240,241/S
    12 02 F/S
    15 19 F/1
    20 0 – 3 F/022, 023
    48 2 14/S
    51 10 F/S
    90 00 F/S
    Do Not Disturb - System 08 – 240, 241/S
    13 00 F/0
    48 2 14/S
    51 10 F/S
    90 00 F/S
    Hotel/Motel Attendant Console 90 00 F/S
    Hotel/Motel Front Desk
    Instrument02 – 0, 1, 2/S
    10 – F/S
    12 02 F/S
    15 62 F/1
    90 00 F/S
    D000 – 2/1
    D001 – F/S
    D035 – F/S
    House Phone 08 – 055, 056/S
    12 03 F/00 – 03
    51 14 00 – 03/S Table 2-7  List of Commands for Each Hotel/Motel Feature (Continued)
    For Hotel/Motel SystemF:  First Data
    S :  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/2N D DATA
    (F/S)REMARKS
    CODE Y-YYY 
    						
    							ND-45669 (E) CHAPTER 2
    Page 53
    Revision 2.0
    INFORMATION FOR DATA PROGRAMMING
    Maid Status 08 – 281/S
    20 0 – 3 F/029
    90 00 F/F1069
    D015 – F/S
    D016 – XX06/1
    D031 – F/S
    Message Registration – – – Refer to SMDR System 
    Manual
    Message Waiting 08 – 233 – 235/S
    12 02 F/S
    13 03, 13 F/S
    15 24, 40 F/S
    20 0 – 3 F/040, 041, A47
    48 2 12/S
    51 15 F/S
    90 00 F/S
    Property Management System
    Interface      Refer to PMS System 
    Manual.
    Room Cut Off 08 – 232/S
    51 11 F/S
    90 00 F/S
    D001 – 5, 13/S
    D015 – F/S
    D016 – XX06, XX46/1
    D031 – F/S
    D033 – F/S
    D034 – F/S
    Room StatusRefer to Maid Status Table 2-7  List of Commands for Each Hotel/Motel Feature (Continued)
    For Hotel/Motel SystemF:  First Data
    S :  Second Data
    — :  No Data
    FEATURECOMMAND
    1S T DATA/2N D DATA
    (F/S)REMARKS
    CODE Y-YYY 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax2000 Ivs Command Manual