    							CHAPTER 3 ND-45669 (E)
    Pag e 1 08
    Revision 2.0
    CM15
    COMMAND CODE
    TITLE:
    SERVICE RESTRICTION CLASS
    15
    MAT
    4. DATA TABLE:
    Service Class A : Initial Data
    YY/YYY SERVICE 
    REST. 
    CLASS (A)SETTING DATA
    No. MEANING DATA MEANING
    00 Call Forwarding – All Calls 00
    150
    1
     
    Restricted
    Allow
    01 Call Hold
    02 Trunk Queueing – Outgoing
    03 Call Back
    04 Guest Name Display via PMS 0
    1 Allow
    Restricted
    05 Executive Override (Calling side) 0
    1 Restricted
    Allow
    06 System Speed Dialing
    07 Station Speed Dialing
    08 Paging Access (External Speaker and Radio)
    09 Executive Override/Busy Verification (Called 
    side)
    10 Call Forwarding – No Answer
    11 Call Forwarding – Busy Line
    12 Call Forwarding – Busy Line/No Answer
    13 Wake Up Timed Reminder
    14 Call Pickup – Direct
    15 Call Forwarding – Destination
    16 Camp-On by Station (Transfer Method)
    17 Priority Call 0
    18 Priority Call 1
    19 Do Not Disturb from Station/Return Message 
    Schedule
    20 Wake Up call assignment for guest station from 
    predetermined station (serial setting for multiple 
    stations with same time)
    21 Wake-up call assignment for guest station from 
    predetermined station (serial setting for multiple 
    stations with different time)
    22 Trunk to Trunk Transfer
    ~ 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 1 09
    Revision 2.0
    CM15
    COMMAND CODE
    TITLE:
    SERVICE RESTRICTION CLASS
    15
    MAT
    24 Message Waiting Lamp set/reset from the sta-
    tion00
    150
    1 Restricted
    Allow
    25 Timed Queue
    26 Call Forwarding – All Calls – Outside
    27 Call Forwarding – No Answer – Outside
    28 Call Forwarding – Busy Line – Outside
    29 Call Forwarding – Busy Line – Outside/
    No Answer – Outside
    30 Account Code
    31 Authorization Code/Forced Account Code
    32 BGM on Multiline Terminal
    33 Digital Announcement Trunk Access (Record/
    Replay/Delete)
    34 Announcement Service (Replay)
    - No. 0 Announcement Service Group
    35 Announcement Service (Replay)
    - No. 1 Announcement Service Group
    36 Announcement Service (Replay)
    - No. 2 Announcement Service Group
    37 Announcement Service (Replay)
    - No. 3 Announcement Service Group
    38 Announcement Service (Replay)
    - No. 4 Announcement Service Group
    39 Announcement Service (Recording)
    40 Message Waiting Lamp Control from predeter-
    mined station or ATTCON
    41 Voice Message Waiting Service
    - System/Individual (Set/Cancel/Retrieve)
    42 Voice Message Waiting Service
    - System (Recording)
    43 Camp-On by Station (Call Waiting Method)
    (Set - Calling Side)Service Class A : Initial Data
    YY/YYY SERVICE 
    REST. 
    CLASS (A)SETTING DATA
    No. MEANING DATA MEANING
    ~ 
    						
    							CHAPTER 3 ND-45669 (E)
    Page 110 Addendum-002
    Revision 2.2 JANUARY, 1999
    CM15
    COMMAND CODE
    TITLE:
    SERVICE RESTRICTION CLASS
    15
    MAT
    Note:Monitoring telephone conversations may be illegal under certain circumstances and laws.
     Consult a legal ad-
    visor before implementing the monitoring of telephone conversations.
     Some federal and state laws require a
    party monitoring a telephone conversation to use beeptone(s), to notify all parties to the telephone conversa-
    tion, and/or to obtain consent from all parties to the telephone conversation. Some of these laws provide strict
    penalties for illegal monitoring of telephone conversations.
    Service Class A : Initial Data
    YY/YYY SERVICE 
    REST. 
    CLASS (A)SETTING DATA
    No. MEANING DATA MEANING
    44 Camp-On by Station (Call Waiting Method)
    (Answer - Called Side)00
    150
    1 Restricted
    Allow
    46 Call Back - Multiple Assignment
    47 Message Reminder (Setting Side)
    48 Message Reminder (Set Side)
    49 Internal Zone Paging Access/All Zone Internal 
    Paging
    95 Number of digits on the LCD of the Multiline 
    Terminal00
    150
    1 24 digits
    16 digits
    100 Voice Message Waiting Service - Individual 
    (Called Side)00
    150
    1 Restricted
    Allow
    102 Voice Message Waiting Service - Individual All 
    clear when the called station is no answer (Call-
    ing/Called Side)
    103 Station to station/Station to Trunk Call Monitor-
    ing (monitoring side) Note
    104 Station to station/Station to Trunk Call Monitor-
    ing (monitored side) Note
    110 Digital Announcement Trunk Access 
    (Record/Replay/Delete)
    111 Whisper Page (Whispering Side)
    112 Whisper Page (Whispered Side)
    ~
    ~
    ~ 
    						
    							ND-45669 (E) CHAPTER 3
    Addendum-002 Page 110-1
    JANUARY, 1999 Revision 2.2
    CM15
    COMMAND CODE
    TITLE:
    SERVICE RESTRICTION CLASS
    15
    MAT
    Service Class A : Initial Data
    YY/YYY SERVICE 
    REST. 
    CLASS (A)SETTING DATA
    No. MEANING DATA MEANING
    115 PS Call Forwarding-Not Available 00
    150
    1 Allow
    Restricted
    116 Voice Guide (Validity of data set by CM48 Y=2 
    first data 12, 13, 14.)0
    1 Restricted
    Allow
    117 Roaming Service 0
    1 Allow
    Restricted
    119 Simultaneous Paging Class
    120 Dynamic Dial Pad
    124 Remote Hold
    127 WCS Numbering Sharing station number which 
    is informed to calling/called party, SMDR and 
    MCI.00
    150
    1 Main station number 
    is informed
    Sub station number
    (own station number) 
    is informed
    128 WCS Numbering Sharing setting/cancelling 
    Number Sharing from sub station.00
    150
    1 Allowed
    Restricted
    129 WCS Numbering Sharing whether sub station is 
    controlled as same as main station, by a Message 
    Waiting lamp control signal sent to main station.
    Note:This assignment is effective only when
    the system is an Integrated type.00
    150
    1 Main station and sub 
    station are controlled 
    Only main station is 
    controlled
    ~
    ~
    ~
    ~ 
    						
    							THIS PAGE INTENTIONALLY LEFT BLANK.
    CHAPTER 3 ND-45669 (E)
    Page 110-2 Addendum-001
    Revision 2.1 AUGUST, 1998
    This page is for your notes. 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 1 11
    Revision 2.0
    CM15
    COMMAND CODE
    TITLE:
    SERVICE RESTRICTION CLASS
    15
    MAT
    Note:To provide the Multiline Terminal Attendant Position, data “0” must be assigned to a different Service Restric-
    tion Class Number than for regular Multiline Terminal Stations.
    For example:
    CLASS No.00 (ATT Position) CLASS No.15 (Station)
    YY=71 0 1
    YY=73 0 1
    Service Class B : Initial Data
    YY/YYY SERVICE 
    REST. 
    CLASS (B)SETTING DATA
    No. MEANING DATA MEANING
    53 TAS Service 00
    150
    1
     
    Restricted
    Allow
    55 Individual Trunk Access from station
    56 Change of mode for CAT
    59 Starting up MSF from PB telephone/Multiline 
    Terminal by using an access code
    60 Day/Night Mode Change by Station Dialing
    61 Periodic Time Indication Tone Sending
    62 Front Desk Instrument (Multiline Terminal)
    63 Privacy Release
    64 Dual Hold
    66 Inhibit Override by Do Not Disturb
    67 Voice Call (Called Side)
    68 Off-Hook Ringing
    69 Conference Trunk (PN-CFTA) Access for con-
    ference leader
    70 Group Listening 00
    150
    1
     
    Allow
    Restricted
    71 Attendant Position ClassNote0
    1
     
    Attendant Terminal
    Ordinary Station
    72 Automatic Hold 0
    1
     
    Allow
    Restricted
    73 Attendant Position ICI / OPE keyNote0
    1
     
    ICI / OPE key
    Regular Station
    75 Maid Status 00
    150
    1Restricted
    Allow
    78 Set stations to voice first for Station to Station 
    calls00
    150
    1Voice Call D
    term
    Ring Dterm
    ~
    ~
    ~
    ~ 
    						
    							CHAPTER 3  ND-45669  (E)
    C M 15
    MAT
    Serv ic e  Class C   : In itia l Data
    ~
    ~
    ~
    ~
    ~
    ~
    ~
    ~
    ~
    ~
    ~
    ~ 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 1 13
    Revision 2.0
    CM15
    COMMAND CODE
    TITLE:
    SERVICE RESTRICTION CLASS
    15
    MAT
    Note 1:The tone indication pattern is assigned by the combination of data in YY=83 and YY = 84
    Note 2:The result of a Switch Hook Flash during a station-to-station call is specified by the combination
    of data in YY= 88 and YY = 89.
    Note 3:The result of a Switch Hook Flash during a C.O. line Connection is specified by the combination
    of data in YY=90 and YY = 91.
    Note 4:Automatic Allocation is available by Multiline Terminal with LCD for call park-system.
    Note 5:Service for an Off Hook Alarm call which encounters a busy terminating station is specified by
    the combination of data in YY=97 and YY = 98
    Note 6:Call Waiting is automatically set, when UCD is not set.
    : Initial Data
    YY 83 84 MEANING OF DATA
    Setting Data 0 0 600 + 700 [Hz] Modulating Signal
    1 0 1024 + 1285 [Hz]/16 [Hz] Modulating Signal
    0 1 480 + 606 [Hz]/8 [Hz] Modulating Signal
    1 1 480 + 606 [Hz]/16 [Hz] Modulating Signal
    : Initial Data
    88 89 MEANING OF DATA
    1 1 Effective (Special Dial Tone Connection)
    0 1 Ineffective
    0 0 Attendant Recall
    : Initial Data
    90 91 MEANING OF DATA
    1 1 Effective (Special Dial Tone Connection)
    0 1 Ineffective
    0 0 Attendant Recall
    : Initial Data
    97 98 MEANING OF DATA
    0 0 UCD - Call WaitingNote 6(CM08-212-0)
    0 1 UCD (CM08-212-1)
    1 0 Call Waiting
    1 1 Hunting 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 1 14
    Revision 2.0
    CM16
    COMMAND CODE
    TITLE:
    CALL PICKUP GROUP/GROUP DIVERSION GROUP
    16
    MAT
    1. FUNCTION:
    This command is used to assign stations to a Call Pickup Group and a Group Diversion Group.
    2. PRECAUTION:
    (1) The maximum number of stations which can be assigned to a Call Pickup Group is 60.
    (2) There is no limitation to the number of Call Pickup Groups.
    (3) An individual station cannot be assigned to more than one Call Pickup Group.
    (4) A maximum of 31 Group Diversion groups can be assigned.
    There is no limitation to the number of stations within a Group Diversion group.
    (5) This command is included in MAT mode menu “A3” (Call Pickup Group [COM01]).
    (6) Group Diversion does not work for stations that are not in the Call Pickup Group.
    3. ASSIGNMENT PROCEDURE:
    ST + 16Y + DE + + DE + + EXESTATION NUMBER (A)
    (1-4 digits)D ATA
    (1-4 digits)
    [CM16] Call Pickup Group/Group Diversion Group 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 1 15
    Revision 2.0
    CM16
    COMMAND CODE
    TITLE:
    CALL PICKUP GROUP/GROUP DIVERSION GROUP
    16
    MAT
    4. DATA TABLE:
    Y STATION NUMBER (A) SETTING DATA
    No. MEANING DATA MEANING DATA MEANING
    0 Assignment of Station 
    Numbers to be included 
    in a Call Pickup GroupX
    XXXXStation Numbers (A) X
    XXXXStation Number (B)
    When assigning station numbers to a Call Pickup Group, only two station 
    numbers can be assigned per operation.  Thus, by repeating the operation as 
    often as required, all the station numbers to be included in a Call Pickup 
    Group can be assigned.  The two station numbers to be assigned by one op-
    eration are defined as Station Number (A) and Station Number (B).
    For example, when defining a Call Pickup Group with Station Numbers 300, 
    301, and 302, three operations are performed.
    Station Number (A)
    Station Number (B)
    1st Operation 300 301
    2nd Operation 301 302
    3rd Operation 302 300
    By these three operations, a chain of three lines is set up.  As seen above, 
    one station can be either Station Number (A) or Station Number (B).  Thus, 
    Station Number (A)/(B) is used for identifying which of the two station 
    numbers is to be set first.
    2
    (CF-DA
    SYS
    STA)Assignment of Station 
    Number to be included 
    in Group DiversionX
    XXXXStation Numbers to be 
    included in Group Di-
    version00
    30Group Diversion Group 00
    Group Diversion Group 30
    (See CM19 Y = 6)
    3 Display of Station Num-
    bers included in a Call 
    Pickup GroupBy entering a Station Number as the first data, the station numbers included 
    in the Group are displayed by depressing the 
     key.
    OPERATION
    DISPLAY
    1st STN A +   STN A: STN B
    2nd +  STN B: STN C
    3rd +   STN C: END
    ~~
    ~~~
    DE
    DE
    DE
    DE 
    						
    All NEC manuals Comments (0)