    							CHAPTER 3 ND-45669 (E)
    Pag e 3 12
    Revision 2.0
    CMA0
    COMMAND CODE
    TITLE:
    TYPE OF DATA ADAPTER
    A0
    MAT
    4. DATA TABLE:
    1. FUNCTION:
    This command is used to specify the type of Data Adapter used for accommodating a Data Terminal to
    the data station.
    2. PRECAUTION:
    This command is included in MAT mode menu “E5” (Data Station Attribute [COM02]).
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    DATA STATION
    NUMBER (STA NO.)SETTING DATA (TYPE)
    RELATED
    COMMAND
    DATA MEANING (TYPE OF DATA ADAPTER)
    X
    XXXX02 SN1152 DTAM – A Data Adapter CMMA1
    CM1A
    04 Data Port Controller (DPC)
    15 Not used
    STDEDEEXE
    ++A0 + + + +DATA STATION
    (2 digits) NUMBER
    (1-4 digits)DATA
    ~
    [CMA0] Type Of Data Adapter 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 13
    Revision 2.0
    CMA1
    COMMAND CODE
    TITLE:
    DATA TERMINAL ATTRIBUTE DATA
    A1
    MAT
    4. DATA TABLE:
    1. FUNCTION:
    This command is used to define the attribute data (terminal characteristics data for data communications)
    of each data terminal.
    2. PRECAUTION:
    This command is included in MAT mode menu “E5” (Data Station Attribute [COM02]).
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    YY SETTING DATA
    RELATED
    COMMAND
    No. MEANING DATA MEANING
    00
    (ER)Detection of ER (DTR) signal 
    from Data terminal0
    1Not to be detected
    To be detected
    01
    (AUTO)Automatic answer 0
    1Automatic answer
    Manual or Automatic
    (Selectable by  Key)
    STDEDEEXE
    ++A1YY + + + +DATA STATION
    (2 digits) NUMBER
    (1-4 digits)DATA
    AUTO
    [CMA1] Data Terminal Attribute Data 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 14
    Revision 2.0
    CMA1
    COMMAND CODE
    TITLE:
    DATA TERMINAL ATTRIBUTE DATA
    A1
    MAT
    04
    (SPEED)Data Speed 00
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17–3150 bps
    75 bps
    110 bps
    150 bps
    200 bps
    300 bps
    600 bps
    1200 bps
    2400 bps
    4800 bps
    9600 bps
    19.2 Kbps
    48 Kbps
    56 Kbps
    64 Kbps
    7200 bps
    14.4 Kbps
    1200 bps
    05
    (PRTY)Parity Check 0
    1Effective
    Ineffective
    06
    (SYNC)Synchronous/Asynchronous 0
    1
    2
    3
    7Synchronous Transmission by In-
    ternal Clock (PBX Clock)
    Synchronous Transmission by Ex-
    ternal Clock (PBX Clock)
    Synchronous Transmission by Ex-
    ternal Clock (ST 1 Mode)
    Synchronous Transmission by Ex-
    ternal Clock (ST2 Mode)
    Asynchronous
    07
    (HDX)Duplex or half-duplex 0
    1
    08
    (STOP)Stop Bit 0
    12-Stop Bit
    1-Stop Bit
    : Initial Data
    YY SETTING DATA
    RELATED
    COMMAND
    No. MEANING DATA MEANING
    Note:When using Data
    Port Controller
    (DPC), the 50 bps
    through 300 bps
    are converted to
    1200 bps. 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 15
    Revision 2.0
    CMA1
    COMMAND CODE
    TITLE:
    DATA TERMINAL ATTRIBUTE DATA
    A1
    MAT
    09
    (CHR)Type of Code 00
    01
    02
    03
    04
    05
    06
    07
    15ASCII (7-bit) + even parity
    ASCII (7-bit) + odd parity
    ASCII (7-bit) + parity (0)
    ASCII (7-bit) + parity (1)
    JIS (7-bit) + even parity
    JIS (7-bit) + odd parity
    JIS (8-bit)
    EBCDIC (8-bit)
    Non character (Binary Data)
    11
    (HOTL)Hot Line Data Station 0
    1Hot Line Data Station 
    (Calling Side)
    Ordinary Data StationCM52
    12
    (HOTC)Hot Line connection 0
    1By “DATA” key or ER (DTR) sig-
    nal (ON) of the terminal
    By “DATA” keyCM52
    13
    (CI)CI (RI) signal sent to terminal 0
    1
    2
    32 sec ON, 4 sec OFF
    1 sec ON, 2 sec OFF
    Continuous signal
    14
    (CSTIM)CS (CTS) delay timing after send-
    ing RS (RTS)00
    1501: 0 ms
    02: 30 ms
    03: 60 ms
    04: 120 ms
    05: 240 ms
    06: 360 ms
    07: 720 ms
    08: 1080 ms
    15: 60 ms
    21 Rate Adaptation 00
    04
    15PROTIMS
    V. 110
    Not used
    : Initial Data
    YY SETTING DATA
    RELATED
    COMMAND
    No. MEANING DATA MEANING 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 16
    Revision 2.0
    CMA5
    COMMAND CODE
    TITLE:
    NAILED DOWN CONNECTION
    A5
    4. DATA TABLE:
    1. FUNCTION:
    This command is used to define a nailed-down connection, which provides a fixed connection between
    data stations, data station and DTI (Digital Trunk Interface) or DTIs.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    YYSETTING DATA
    DATA STATION NUMBER (A) / 
    TRUNK NUMBER (A)
    +
    DATA STATION NUMBER (B) / 
    TRUNK NUMBER (B)RELATED
    COMMAND
    No. MEANING DATA MEANING
    00
    99Memory Block 00
    Memory Block 99X
    XXXXData Station Number CM1A
    DXXX Trunk Number assigned by CM07 
    YY = 01CM07 YY = 01
    ST  + A5YY +  DE  + DATA STATION NUMBER (A)
    (1 - 4 digits)TRUNK NUMBER (A)
    (1 - 4 digits)+  DE  +
    DATA STATION NUMBER (B)
    (1 - 4 digits)TRUNK NUMBER (B)
    (1 - 4 digits)+  EXE
    ~~~
    [CMA5] Nailed Down Connection 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 17
    Revision 2.0
    CMA6
    COMMAND CODE
    TITLE:
    ATTRIBUTE DATA FOR RS-232C PORT ON AP01
    A6
    MAT
    4. DATA TABLE:
    1. FUNCTION:
    This command is used to assign the attribute data for the RS-232C port on the PN-AP01 card.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    YY SETTING DATA
    RECOMMENDED
    SETTING
    No. MEANING DATA MEANING
    04 Data Transmission Speed of 
    RS-232C Port0
    1
    2
    3
    4
    5
    6150 bps
    300 bps
    600 bps
    1200 bps
    2400 bps
    4800 bps
    9600 bps5
    (example)
    05 Parity Check 0
    1 Effective
    Ineffective1
    06 Synchronous/Asynchronous 0
    3
    7 Synchronous Transmission by 
    Internal
    Synchronous Transmission by 
    External
    Asynchronous7
    07 Duplex or half-duplex 0
    1 Half-duplex
    Duplex1
    ST  + A6YY +  DE  +  3  +DATA
    (1 - 2 digits)+  EXE
    [CMA6] Attribute Data For RS-232C Port On AP01 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 18
    Revision 2.0
    CMA6
    COMMAND CODE
    TITLE:
    ATTRIBUTE DATA FOR RS-232C PORT ON AP01
    A6
    MAT
    08 Stop Bit 0
    1 2-Stop Bit
    1-Stop Bit1
    09 Type of Code 00
    01
    02
    03
    04
    05
    06
    07
    15 ASCII (7-bit) + even parity
    ASCII (7-bit) + odd parity
    ASCII (7-bit) + parity (0)
    ASCII (7-bit) + parity (1)
    JIS (7-bit) + even parity
    JIS (7-bit) + odd parity
    JIS (8-bit)
    EBCDIC (8-bit)
    Non character (Binary Data)06
    10 DCD Signal check at Data Trans-
    mission0
    1 Ineffective
    Effective0
    (example)
    11 RTS Signal Control 0
    1 Ineffective (RTS Signal ON)
    Effective1
    (example)
    12 Designate of Signal for detecting 
    line disconnection0
    1 DCD (with MODEM)
    DSR (without MODEM)
    20 Designate of Facility 0
    1
    2 OAI2
    21 Priority 0
    1
    21st Priority
    2nd Priority
    3rd Priority0
    22 Message of Sub-Function 0 Not in use
    : Initial Data
    YY SETTING DATA
    RECOMMENDED
    SETTING
    No. MEANING DATA MEANING
    Not used 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 19
    Revision 2.0
    CMA6
    COMMAND CODE
    TITLE:
    ATTRIBUTE DATA FOR RS-232C PORT ON AP01
    A6
    MAT
    24 Kind of procedure 1
    3
    4Free Wheel 1
    : Initial Data
    YY SETTING DATA
    RECOMMENDED
    SETTING
    No. MEANING DATA MEANING
    Not used 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 20
    Revision 2.0
    CMA7
    COMMAND CODE
    TITLE:
    CCIS CHANNEL DATA
    A7
    4. DATA TABLE:
    1. FUNCTION:
    This command assigns the various data to each Common Channel Handler (CCH) provided.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    YY SETTING DATA
    RELATED 
    COMMAND
    No. MEANING DATA MEANING
    00 Assignment of the trunk used as the 
    Common Signaling channel000
    255Trunk number assigned by CM07 
    YY = 01 / YY = 02
    01 Assignment of the Originating Point 
    Code (OPC)00001
    16367Originating Point Code
    02 Assignment of the Destination Point 
    Code (DPC)00001
    16367Destination Point Code
    03 Centralized Billing Facility 0
    1
    3Distant End is a Centralized 
    Office
    Distant End is a Local Office
    Not to be provided
    04 Assignment of Centralized Billing 
    destination00001
    16367Point Code of Centralized Billing 
    Office
    ST  +  A7YY + DE + CCH No. (0-3) + DE  +DATA
    (1 - 5 digits)+ EXE
    ~ ~ ~
    ~
    [CMA7] CCIS Channel Data 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 21
    Revision 2.0
    CMA7
    COMMAND CODE
    TITLE:
    CCIS CHANNEL DATA
    A7
    05 Assignment of the Centralized Fault 
    Reporting destination00001
    16367Point Code of Centralized Fault Re-
    porting office
    06 Assignment of the Originating Of-
    fice Number0
    9999Originating Office Number
    10 Assignment of the ACM signal wait-
    ing timer after sending IAI signal 
    when originating calls via CCIS.
    Note:Assign the primary digit
    number of the 5-digit sta-
    tion number to be dis-
    played.00
    01
    14
    150 sec.
    2 sec.
     (Increment Unit : 2 sec.)
    28 sec.
    10 sec.
    26 Calling Name Display-CCIS
    Note:This data is effective when
    CM08-255 2nd data is 1
    and CM08-379 2nd data is
    0.0
    1To be provided
    Not to be providedCM08-255, 379
    27 Specify the CCH for Event Based 
    CCIS0
    1CCH for Event Based CCIS
    CCH for nomal CCIS
    28 Assignment of calling Party infor-
    mation transferring service0
    1To be provided
    Not to be provided
    : Initial Data
    YY SETTING DATA
    RELATED 
    COMMAND
    No. MEANING DATA MEANING
    ~ ~ ~
    ~ 
    						