CHAPTER 3 ND-45669 (E) Pag e 3 12 Revision 2.0 CMA0 COMMAND CODE TITLE: TYPE OF DATA ADAPTER A0 MAT 4. DATA TABLE: 1. FUNCTION: This command is used to specify the type of Data Adapter used for accommodating a Data Terminal to the data station. 2. PRECAUTION: This command is included in MAT mode menu “E5” (Data Station Attribute [COM02]). 3. ASSIGNMENT PROCEDURE: : Initial Data DATA STATION NUMBER (STA NO.)SETTING DATA (TYPE) RELATED COMMAND DATA MEANING (TYPE OF DATA ADAPTER) X XXXX02 SN1152 DTAM – A Data Adapter CMMA1 CM1A 04 Data Port Controller (DPC) 15 Not used STDEDEEXE ++A0 + + + +DATA STATION (2 digits) NUMBER (1-4 digits)DATA ~ [CMA0] Type Of Data Adapter
ND-45669 (E) CHAPTER 3 Pag e 3 13 Revision 2.0 CMA1 COMMAND CODE TITLE: DATA TERMINAL ATTRIBUTE DATA A1 MAT 4. DATA TABLE: 1. FUNCTION: This command is used to define the attribute data (terminal characteristics data for data communications) of each data terminal. 2. PRECAUTION: This command is included in MAT mode menu “E5” (Data Station Attribute [COM02]). 3. ASSIGNMENT PROCEDURE: : Initial Data YY SETTING DATA RELATED COMMAND No. MEANING DATA MEANING 00 (ER)Detection of ER (DTR) signal from Data terminal0 1Not to be detected To be detected 01 (AUTO)Automatic answer 0 1Automatic answer Manual or Automatic (Selectable by Key) STDEDEEXE ++A1YY + + + +DATA STATION (2 digits) NUMBER (1-4 digits)DATA AUTO [CMA1] Data Terminal Attribute Data
CHAPTER 3 ND-45669 (E) Pag e 3 14 Revision 2.0 CMA1 COMMAND CODE TITLE: DATA TERMINAL ATTRIBUTE DATA A1 MAT 04 (SPEED)Data Speed 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17–3150 bps 75 bps 110 bps 150 bps 200 bps 300 bps 600 bps 1200 bps 2400 bps 4800 bps 9600 bps 19.2 Kbps 48 Kbps 56 Kbps 64 Kbps 7200 bps 14.4 Kbps 1200 bps 05 (PRTY)Parity Check 0 1Effective Ineffective 06 (SYNC)Synchronous/Asynchronous 0 1 2 3 7Synchronous Transmission by In- ternal Clock (PBX Clock) Synchronous Transmission by Ex- ternal Clock (PBX Clock) Synchronous Transmission by Ex- ternal Clock (ST 1 Mode) Synchronous Transmission by Ex- ternal Clock (ST2 Mode) Asynchronous 07 (HDX)Duplex or half-duplex 0 1 08 (STOP)Stop Bit 0 12-Stop Bit 1-Stop Bit : Initial Data YY SETTING DATA RELATED COMMAND No. MEANING DATA MEANING Note:When using Data Port Controller (DPC), the 50 bps through 300 bps are converted to 1200 bps.
ND-45669 (E) CHAPTER 3 Pag e 3 15 Revision 2.0 CMA1 COMMAND CODE TITLE: DATA TERMINAL ATTRIBUTE DATA A1 MAT 09 (CHR)Type of Code 00 01 02 03 04 05 06 07 15ASCII (7-bit) + even parity ASCII (7-bit) + odd parity ASCII (7-bit) + parity (0) ASCII (7-bit) + parity (1) JIS (7-bit) + even parity JIS (7-bit) + odd parity JIS (8-bit) EBCDIC (8-bit) Non character (Binary Data) 11 (HOTL)Hot Line Data Station 0 1Hot Line Data Station (Calling Side) Ordinary Data StationCM52 12 (HOTC)Hot Line connection 0 1By “DATA” key or ER (DTR) sig- nal (ON) of the terminal By “DATA” keyCM52 13 (CI)CI (RI) signal sent to terminal 0 1 2 32 sec ON, 4 sec OFF 1 sec ON, 2 sec OFF Continuous signal 14 (CSTIM)CS (CTS) delay timing after send- ing RS (RTS)00 1501: 0 ms 02: 30 ms 03: 60 ms 04: 120 ms 05: 240 ms 06: 360 ms 07: 720 ms 08: 1080 ms 15: 60 ms 21 Rate Adaptation 00 04 15PROTIMS V. 110 Not used : Initial Data YY SETTING DATA RELATED COMMAND No. MEANING DATA MEANING
CHAPTER 3 ND-45669 (E) Pag e 3 16 Revision 2.0 CMA5 COMMAND CODE TITLE: NAILED DOWN CONNECTION A5 4. DATA TABLE: 1. FUNCTION: This command is used to define a nailed-down connection, which provides a fixed connection between data stations, data station and DTI (Digital Trunk Interface) or DTIs. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: YYSETTING DATA DATA STATION NUMBER (A) / TRUNK NUMBER (A) + DATA STATION NUMBER (B) / TRUNK NUMBER (B)RELATED COMMAND No. MEANING DATA MEANING 00 99Memory Block 00 Memory Block 99X XXXXData Station Number CM1A DXXX Trunk Number assigned by CM07 YY = 01CM07 YY = 01 ST + A5YY + DE + DATA STATION NUMBER (A) (1 - 4 digits)TRUNK NUMBER (A) (1 - 4 digits)+ DE + DATA STATION NUMBER (B) (1 - 4 digits)TRUNK NUMBER (B) (1 - 4 digits)+ EXE ~~~ [CMA5] Nailed Down Connection
ND-45669 (E) CHAPTER 3 Pag e 3 17 Revision 2.0 CMA6 COMMAND CODE TITLE: ATTRIBUTE DATA FOR RS-232C PORT ON AP01 A6 MAT 4. DATA TABLE: 1. FUNCTION: This command is used to assign the attribute data for the RS-232C port on the PN-AP01 card. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: : Initial Data YY SETTING DATA RECOMMENDED SETTING No. MEANING DATA MEANING 04 Data Transmission Speed of RS-232C Port0 1 2 3 4 5 6150 bps 300 bps 600 bps 1200 bps 2400 bps 4800 bps 9600 bps5 (example) 05 Parity Check 0 1 Effective Ineffective1 06 Synchronous/Asynchronous 0 3 7 Synchronous Transmission by Internal Synchronous Transmission by External Asynchronous7 07 Duplex or half-duplex 0 1 Half-duplex Duplex1 ST + A6YY + DE + 3 +DATA (1 - 2 digits)+ EXE [CMA6] Attribute Data For RS-232C Port On AP01
CHAPTER 3 ND-45669 (E) Pag e 3 18 Revision 2.0 CMA6 COMMAND CODE TITLE: ATTRIBUTE DATA FOR RS-232C PORT ON AP01 A6 MAT 08 Stop Bit 0 1 2-Stop Bit 1-Stop Bit1 09 Type of Code 00 01 02 03 04 05 06 07 15 ASCII (7-bit) + even parity ASCII (7-bit) + odd parity ASCII (7-bit) + parity (0) ASCII (7-bit) + parity (1) JIS (7-bit) + even parity JIS (7-bit) + odd parity JIS (8-bit) EBCDIC (8-bit) Non character (Binary Data)06 10 DCD Signal check at Data Trans- mission0 1 Ineffective Effective0 (example) 11 RTS Signal Control 0 1 Ineffective (RTS Signal ON) Effective1 (example) 12 Designate of Signal for detecting line disconnection0 1 DCD (with MODEM) DSR (without MODEM) 20 Designate of Facility 0 1 2 OAI2 21 Priority 0 1 21st Priority 2nd Priority 3rd Priority0 22 Message of Sub-Function 0 Not in use : Initial Data YY SETTING DATA RECOMMENDED SETTING No. MEANING DATA MEANING Not used
ND-45669 (E) CHAPTER 3 Pag e 3 19 Revision 2.0 CMA6 COMMAND CODE TITLE: ATTRIBUTE DATA FOR RS-232C PORT ON AP01 A6 MAT 24 Kind of procedure 1 3 4Free Wheel 1 : Initial Data YY SETTING DATA RECOMMENDED SETTING No. MEANING DATA MEANING Not used
CHAPTER 3 ND-45669 (E) Pag e 3 20 Revision 2.0 CMA7 COMMAND CODE TITLE: CCIS CHANNEL DATA A7 4. DATA TABLE: 1. FUNCTION: This command assigns the various data to each Common Channel Handler (CCH) provided. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: : Initial Data YY SETTING DATA RELATED COMMAND No. MEANING DATA MEANING 00 Assignment of the trunk used as the Common Signaling channel000 255Trunk number assigned by CM07 YY = 01 / YY = 02 01 Assignment of the Originating Point Code (OPC)00001 16367Originating Point Code 02 Assignment of the Destination Point Code (DPC)00001 16367Destination Point Code 03 Centralized Billing Facility 0 1 3Distant End is a Centralized Office Distant End is a Local Office Not to be provided 04 Assignment of Centralized Billing destination00001 16367Point Code of Centralized Billing Office ST + A7YY + DE + CCH No. (0-3) + DE +DATA (1 - 5 digits)+ EXE ~ ~ ~ ~ [CMA7] CCIS Channel Data
ND-45669 (E) CHAPTER 3 Pag e 3 21 Revision 2.0 CMA7 COMMAND CODE TITLE: CCIS CHANNEL DATA A7 05 Assignment of the Centralized Fault Reporting destination00001 16367Point Code of Centralized Fault Re- porting office 06 Assignment of the Originating Of- fice Number0 9999Originating Office Number 10 Assignment of the ACM signal wait- ing timer after sending IAI signal when originating calls via CCIS. Note:Assign the primary digit number of the 5-digit sta- tion number to be dis- played.00 01 14 150 sec. 2 sec. (Increment Unit : 2 sec.) 28 sec. 10 sec. 26 Calling Name Display-CCIS Note:This data is effective when CM08-255 2nd data is 1 and CM08-379 2nd data is 0.0 1To be provided Not to be providedCM08-255, 379 27 Specify the CCH for Event Based CCIS0 1CCH for Event Based CCIS CCH for nomal CCIS 28 Assignment of calling Party infor- mation transferring service0 1To be provided Not to be provided : Initial Data YY SETTING DATA RELATED COMMAND No. MEANING DATA MEANING ~ ~ ~ ~