CHAPTER 3 ND-45669 (E) Pag e 3 88 Revision 2.0 CMD001 COMMAND CODE TITLE: SYSTEM FEATURES (2) D001 Note:Port 3 can only be connected to the printer for which the RTS signal from the PN-AP00 is not needed. Table 3-3 Quick Reference Data Table for Printer : Initial Data 1ST DATA MEANING2ND DATAMEANING PORT 0 PORT 1 PORT 2 PORT 3 20 24 28 32 Data speed 2 1200 bps 21 25 28 33 ?Stop bit length 2 2 bits 22 26 30 34 Data length 0 7 bits 23 27 31 35 Parity 1 Even parity 80 100 120 140 Function 16/17 Hotel Printer 0/ Hotel Printer 1 81 101 121 141 Priority for data processing 1 2nd 82 102 122 142 Number of characters per line to be printed out 2 80 characters 83 103 123 143 Number of lines per page 0-88 See description of commands 84 104 124 144 Number of lines per page to be printed out 0-88 See description of commands 85 105 125 145 Station Address (SA) 0 Not used 86 106 126 146 Unit Address (UA) 0 Not used 87 107 127 147 Timer for detecting the terminal no answer 0 Not used 89 109 129 149 Timer for detecting the end of block 0 Not used 90 110 130 150 Timer for detecting non data communication 0 Not used 91 111 131 151 Number of times to resend the Selecting Se- quence when NAK is returned in Phase 20Not used 92 112 132 152 Number of times to resend the Selecting Se- quence when no answer in Phase 20Not used 93 113 133 153 Number of times to resend the Selecting Se- quence when NAK is returned in Phase 30Not used 94 114 134 154 Number of times to resend the Selecting Se- quence when no answer in Phase 30Not used 95 115 135 155 Delay before resending the Selecting Sequence when NAK is returned0Not used 96 116 136 156 Delay before resending the text when WABT is returned0Not used 98 118 138 158 Guard timer between texts 0 Not used
ND-45669 (E) CHAPTER 3 Pag e 3 89 Revision 2.0 CMD001 COMMAND CODE TITLE: SYSTEM FEATURES (2) D001 Note:Port 3 cannot be used for the PMS (IMS format). Table 3-4 Quick Reference Data Table for PMS (IMS Format) : Initial Data 1ST DATA MEANING2ND DATAMEANING PORT 0 PORT 1 PORT 2 PORT 3 20 24 28 – Data speed 2/3/4/5 1200/2400/ 4800/9600 bps 21 25 29 – Stop bit length 0 /1/2 1/1.5/2 bits 22 26 30 – Data length 0 /1 7/8 bits 23 27 31 – Parity 0 /1/2 None Parity/Even Parity/Odd Parity 80 100 120 – Function 4 PMS 81 101 121 – Priority for data processing 0 1st priority 82 102 122 – Message Format 6 PMS format (IMS format) 83 103 123 – Number of lines per page 0 Not used 84 104 124 – Protocol 6 IMS procedure 85 105 125 – Station Address (SA) 49 1 86 106 126 – Unit Address (UA) 33 ! 87 107 127 – Timer for detecting terminal/no answer 8 1 sec. 89 109 129 – Timer for detecting the end of block 70 35 sec. 90 110 130 – Timer for detecting non data communication 70 35 sec. 91 111 131 – Number of times to resend the Selecting Sequence when NAK is returned in Phase 233 times 92 112 132 – Number of times to resend the Selecting Sequence when no answer in Phase 215 15 times 93 113 133 – Number of times to resend the Selecting Sequence when NAK is returned in Phase 333 times 94 114 134 – Number of times to resend the Selecting Sequence when no answer in Phase 332 15 times 95 115 135 – Delay before resending the Selecting Sequence when NAK is returned24 3 sec. 96 116 136 – Delay before resending the text when WABT is returned24 3 sec. 98 118 138 – Guard timer between texts 0 Not used
CHAPTER 3 ND-45669 (E) Pag e 3 90 Revision 2.0 CMD001 COMMAND CODE TITLE: SYSTEM FEATURES (2) D001 Note:Port 3 can only be connected to the VMS, which the RTS signal from the PN-AP00 is not needed. Table 3-5 Quick Reference Data Table for VMS with MCI : Initial Data 1ST DATA MEANING2ND DATAMEANING PORT 0 PORT 1 PORT 2 PORT 3 20 24 28 32 Data speed 2/3/4/5 1200/2400/ 4800/9600 bps 21 25 29 33 Stop bit length 0 /1/2 1/1.5/2 bits 22 26 30 34 Data length 0 /1 7/8 bits 23 27 31 35 Parity 0 /1/2/ 3None Parity/Even Parity/Odd Parity 80 100 120 140 Function 24 MCI 81 101 121 141 Priority for data processing 0 1st priority 82 102 122 142 Message Format 0 Not used 83 103 123 143 Number of lines per page 0 Not used 84 104 124 144 Protocol 0 Not used 85 105 125 145 Station Address (SA) 48 0 86 106 126 146 Unit Address (UA) 33 ! 87 107 127 147 Timer for detecting terminal/no answer 0 Not used 89 109 129 149 Timer for detecting end of block 5 512 msec. 90 110 130 150 Timer for detecting non data communication 0 Not used 91 111 131 151 Number of times to resend Selecting Sequence when NAK is returned in Phase 20Not used 92 112 132 152 Number of times to resend Selecting Sequence when no answer in Phase 20Not used 93 113 133 153 Number of times to resend Selecting Sequence when NAK is returned in Phase 30Not used 94 114 134 154 Number of times to resend Selecting Sequence when no answer in Phase 30Not used 95 115 135 155 Delay before resending Selecting Sequence when NAK is returned0Not used 96 116 136 156 Delay before resending text when WABT is returned0Not used 98 118 138 158 Guard timer between texts 0 1 2 3 40-128 msec. 128-256 msec. 256-384 msec. 384-512 msec. 512-640 msec.
ND-45669 (E) CHAPTER 3 Pag e 3 91 Revision 2.0 CMD001 COMMAND CODE TITLE: SYSTEM FEATURES (2) D001 : Initial Data 1ST DATA 2ND DATA DATA FUNCTION 176 Carriage Return (CR) and Line Feed (LF) provision for a printer using 80 or 136 characters on NEAX1400 format0 : For a printer using 136 characters per line, with automatic line feed. 1 : For a printer using 136 characters per line. 2 : For providing a line space between call record on a printer using 136 characters. 3 : For a printer using 80 characters per line, with automatic line feed. 4 : For a printer using 80 characters, without automatic line feed. 5 : For a printer using 80 characters per line, with- out automatic line feed and providing a line space between call records. 189 First digit of 5 digits station 0 : 0 9 : 9 ~ ~
CHAPTER 3 ND-45669 (E) Pag e 3 92 Revision 2.0 CMD001 COMMAND CODE TITLE: SYSTEM FEATURES (2) D001 250 Function of OPE (No. 0-3) LED on the PN-AP00 card 0 : Indicates status of data transmission on each port. (See left column.) 1 Indicates status of signal leads on No. 0 port. (See left column.) 2 : Indicates status of signal leads on No. 1 port. (See left column.) 3 : Indicates status of signal leads on No. 2 port. (See left column.) 4:Not used 252 Output unit for Direct Data Entry Note:This data is valid when CMD016-XX24 is set to “1”.0:PMS 1:Printer 2 : PMS and Printer: Initial Data 1ST DATA 2ND DATA DATA FUNCTION PN-AP00 CARD OPELED 0 L3 L2 L1 L0No.3 port SD No.2 port SD No.1 port SD No.0 port SD1 CS CD SD RDNo.0 port2 CS CD SD RDNo.1 port3 CS CD SD RDNo.2 port 2ND DATA
ND-45669 (E) CHAPTER 3 Pag e 3 93 Revision 2.0 CMD001 COMMAND CODE TITLE: SYSTEM FEATURES (2) D001 253 Printout format of Direct Data Entry 0 : Printout format 1 1 : Printout format 2 (See left column) • Printout format 1 • Printout format 2 Note:This data is valid when CMD016-XX24 is set to “1”, moreover CMD001-252 is set to “1” or “2”.: Initial Data 1ST DATA 2ND DATA DATA FUNCTION 1995 04/11 17:20 MON NO. 220 CODE 1 1 CODE 2 2 CODE 3 2 CODE 4 1 1995 04/11 17:20 MON NO. 220 CODE 1 QUANTITY 2 CODE 2 QUANTITY 1
CHAPTER 3 ND-45669 (E) Pag e 3 94 Revision 2.0 CMD003 COMMAND CODE TITLE: TIME BLOCK ASSIGNMENT D003 4. DATA TABLE: 1. FUNCTION: This command is used to determine the Maximum number of Call Records for SMDR. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: : Initial Data 1ST DATA 2ND DATA DATA FUNCTION 29 Maximum number of Call Record for SMDR 0 : No limitation 1:1 call 12000 : 12000 calls STDE + D003 + ++DE (1-5 digits) 2ND DATA + + EXE(2 digits) 1ST DATA ~ ~ [CMD003] Time Block Assignment
ND-45669 (E) CHAPTER 3 Addendum-001 Page 395 AUGUST, 1998 Revision 2.1 CMD004 COMMAND CODE TITLE: OFFICE NUMBER ASSIGNMENT D004 4. DATA TABLE: Note:If using a leading digit(s) of 0 and 0 is required to print at the host terminal, enter “A” for each leading 0 to be printed. If the leading digit(s) 0 is not required to print at the host terminal, enter “0”. 1. FUNCTION: This command is used to assign the office number of the calling party and the office number of the bill- ing office for centralized billing. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: 1ST DATA 2ND DATA DATA FUNCTION 55 Assignment of office number of calling party The office number is output to SMDR when the office num- ber of calling party is not sent from the local office of the call- ing party. NoteX - XXXX: Office No. of calling party 56 Assignment of office number of billing office NoteX - XXXX: Office No. of billing office ST + D004 + DE +1ST DATA (1 - 2 digits)+ DE +2ND DATA (1 - 4 digits)+ EXE [CMD004] Office Number Assignment
CHAPTER 3 ND-45669 (E) Pag e 3 96 Revision 2.0 CMD012 COMMAND CODE TITLE: STATION GROUP NUMBER D012 4. DATA TABLE: Note:Assign Group Number 128 to stations in which a Group Number is not assigned. 1. FUNCTION: By CMD012, a Group Number is to be assigned to each station for sending the tenant information (01- 63) to the SMDR Terminal. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: 1ST DATA 2ND DATA REMARKS X-XXXX : Station Number (1-4 digits) 00-07 : ATTCON Number (2 digits)XXX: Group Number (001-063) + D012 + + + + + STDE1ST DATA (1-4 digits)DE2ND DATA (3 digits)EXE [CMD012] Station Group Number
ND-45669 (E) CHAPTER 3 Pag e 3 97 Revision 2.0 CMD015 COMMAND CODE TITLE: STATION SERVICE CLASSES D015 4. DATA TABLE: 1. FUNCTION: This command is used to assign the class of service to each station and ATTCON. The class functions are assigned by CMD016. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: : Initial Data 1ST DATA 2ND DATA REMARKS X-XXXX : Station Number (1 - 4 digits) 00 - 07 : ATTCON Number (2 digits)XXX : Group Number (001-053) ST + D015 + DE +1ST DATA (1 - 4 digits)+ DE +2ND DATA (2 digits)+ EXE [CMD015] Station Service Classes