    							CHAPTER 3 ND-45669 (E)
    Pag e 3 88
    Revision 2.0
    CMD001
    COMMAND CODE
    TITLE:
    SYSTEM FEATURES (2)
    D001
    Note:Port 3 can only be connected to the printer for which the RTS signal from the PN-AP00 is not needed.
    Table 3-3  Quick Reference Data Table for Printer
    : Initial Data
    1ST DATA
    MEANING2ND 
    DATAMEANING
    PORT 0 PORT 1 PORT 2 PORT 3
    20 24 28 32 Data speed 2 1200 bps
    21 25 28 33 ?Stop bit length 2 2 bits
    22 26 30 34 Data length 0 7 bits
    23 27 31 35 Parity 1 Even parity
    80 100 120 140 Function 16/17 Hotel Printer 0/
    Hotel Printer 1
    81 101 121 141 Priority for data processing 1 2nd
    82 102 122 142 Number of characters per line to be printed out 2 80 characters
    83 103 123 143 Number of lines per page 0-88 See description of 
    commands
    84 104 124 144 Number of lines per page to be printed out 0-88 See description of 
    commands
    85 105 125 145 Station Address (SA) 0 Not used
    86 106 126 146 Unit Address (UA) 0 Not used
    87 107 127 147 Timer for detecting the terminal no answer 0 Not used
    89 109 129 149 Timer for detecting the end of block 0 Not used
    90 110 130 150 Timer for detecting non data communication 0 Not used
    91 111 131 151 Number of times to resend the Selecting Se-
    quence when NAK is returned in Phase 20Not used
    92 112 132 152 Number of times to resend the Selecting Se-
    quence when no answer in Phase 20Not used
    93 113 133 153 Number of times to resend the Selecting Se-
    quence when NAK is returned in Phase 30Not used
    94 114 134 154 Number of times to resend the Selecting Se-
    quence when no answer in Phase 30Not used
    95 115 135 155 Delay before resending the Selecting Sequence 
    when NAK is returned0Not used
    96 116 136 156 Delay before resending the text when WABT is 
    returned0Not used
    98 118 138 158 Guard timer between texts 0 Not used 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 89
    Revision 2.0
    CMD001
    COMMAND CODE
    TITLE:
    SYSTEM FEATURES (2)
    D001
    Note:Port 3 cannot be used for the PMS (IMS format).
    Table 3-4  Quick Reference Data Table for PMS (IMS Format)
    : Initial Data
    1ST DATA
    MEANING2ND 
    DATAMEANING
    PORT 0 PORT 1 PORT 2 PORT 3
    20 24 28 – Data speed 2/3/4/5 1200/2400/
    4800/9600 bps
    21 25 29 – Stop bit length 0 /1/2 1/1.5/2 bits
    22 26 30 – Data length 0 /1 7/8 bits
    23 27 31 – Parity 0 /1/2 None Parity/Even 
    Parity/Odd Parity
    80 100 120 – Function 4 PMS
    81 101 121 – Priority for data processing 0 1st priority
    82 102 122 – Message Format 6 PMS format
    (IMS format)
    83 103 123 – Number of lines per page 0 Not used
    84 104 124 – Protocol 6 IMS procedure
    85 105 125 – Station Address (SA) 49 1
    86 106 126 – Unit Address (UA) 33 !
    87 107 127 – Timer for detecting terminal/no answer 8 1 sec.
    89 109 129 – Timer for detecting the end of block 70 35 sec.
    90 110 130 – Timer for detecting non data communication 70 35 sec.
    91 111 131 – Number of times to resend the Selecting 
    Sequence when NAK is returned in Phase 233 times
    92 112 132 – Number of times to resend the Selecting 
    Sequence when no answer in Phase 215 15 times
    93 113 133 – Number of times to resend the Selecting 
    Sequence when NAK is returned in Phase 333 times
    94 114 134 – Number of times to resend the Selecting 
    Sequence when no answer in Phase 332 15 times
    95 115 135 – Delay before resending the Selecting 
    Sequence when NAK is returned24 3 sec.
    96 116 136 – Delay before resending the text when WABT is 
    returned24 3 sec.
    98 118 138 – Guard timer between texts 0 Not used 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 90
    Revision 2.0
    CMD001
    COMMAND CODE
    TITLE:
    SYSTEM FEATURES (2)
    D001
    Note:Port 3 can only be connected to the VMS, which the RTS signal from the PN-AP00 is not needed.
    Table 3-5  Quick Reference Data Table for VMS with MCI
    : Initial Data
    1ST DATA
    MEANING2ND 
    DATAMEANING
    PORT 0 PORT 1 PORT 2 PORT 3
    20 24 28 32 Data speed 2/3/4/5 1200/2400/
    4800/9600 bps
    21 25 29 33 Stop bit length 0 /1/2 1/1.5/2 bits
    22 26 30 34 Data length 0 /1 7/8 bits
    23 27 31 35 Parity 0 /1/2/
    3None Parity/Even 
    Parity/Odd Parity
    80 100 120 140 Function 24 MCI
    81 101 121 141 Priority for data processing 0 1st priority
    82 102 122 142 Message Format 0 Not used
    83 103 123 143 Number of lines per page 0 Not used
    84 104 124 144 Protocol 0 Not used
    85 105 125 145 Station Address (SA) 48 0
    86 106 126 146 Unit Address (UA) 33 !
    87 107 127 147 Timer for detecting terminal/no answer 0 Not used
    89 109 129 149 Timer for detecting end of block 5 512 msec.
    90 110 130 150 Timer for detecting non data communication 0 Not used
    91 111 131 151 Number of times to resend Selecting 
    Sequence when NAK is returned in Phase 20Not used
    92 112 132 152 Number of times to resend Selecting 
    Sequence when no answer in Phase 20Not used
    93 113 133 153 Number of times to resend Selecting 
    Sequence when NAK is returned in Phase 30Not used
    94 114 134 154 Number of times to resend Selecting 
    Sequence when no answer in Phase 30Not used
    95 115 135 155 Delay before resending Selecting 
    Sequence when NAK is returned0Not used
    96 116 136 156 Delay before resending text when WABT is
    returned0Not used
    98 118 138 158 Guard timer between texts 0
    1
    2
    3
    40-128 msec.
    128-256 msec.
    256-384 msec.
    384-512 msec.
    512-640 msec. 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 91
    Revision 2.0
    CMD001
    COMMAND CODE
    TITLE:
    SYSTEM FEATURES (2)
    D001
    : Initial Data
    1ST DATA
    2ND DATA
    DATA FUNCTION
    176 Carriage Return (CR) and Line Feed (LF) provision for a printer using 80 
    or 136 characters on NEAX1400 format0 : For a printer using 136 
    characters per line, with 
    automatic line feed.
    1 : For a printer using 136 
    characters per line.
    2 : For providing a line space 
    between call record on a 
    printer using 136 
    characters.
    3 : For a printer using 80 
    characters per line, with 
    automatic line feed.
    4 : For a printer using 80 
    characters, without 
    automatic line feed.
    5 : For a printer using 80 
    characters per line, with-
    out automatic line feed 
    and providing a line space 
    between call records.
    189 First digit of 5 digits station 0 :  0
     
    9 :  9
    ~
    ~ 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 92
    Revision 2.0
    CMD001
    COMMAND CODE
    TITLE:
    SYSTEM FEATURES (2)
    D001
    250 Function of OPE (No. 0-3) LED on the PN-AP00 card 0 : Indicates status of data 
    transmission on each port. 
    (See left column.)
    1 Indicates status of signal 
    leads on No. 0 port. (See 
    left column.)
    2 : Indicates status of signal 
    leads on No. 1 port. (See 
    left column.)
    3 : Indicates status of signal 
    leads on No. 2 port. (See 
    left column.)
    4:Not used
    252 Output unit for Direct Data Entry
    Note:This data is valid when CMD016-XX24 is set to “1”.0:PMS
    1:Printer
    2 : PMS and Printer: Initial Data
    1ST DATA
    2ND DATA
    DATA FUNCTION
    PN-AP00 CARD
    OPELED
    0
    L3
    L2
    L1
    L0No.3 port SD
    No.2 port SD
    No.1 port SD
    No.0 port SD1
    CS
    CD
    SD
    RDNo.0
    port2
    CS
    CD
    SD
    RDNo.1
    port3
    CS
    CD
    SD
    RDNo.2
    port
    2ND DATA 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 93
    Revision 2.0
    CMD001
    COMMAND CODE
    TITLE:
    SYSTEM FEATURES (2)
    D001
    253 Printout format of Direct Data Entry 0 : Printout format 1
    1 : Printout format 2
    (See left column)
    • Printout format 1
    • Printout format 2
    Note:This data is valid when CMD016-XX24 is set to “1”, moreover
    CMD001-252 is set to “1” or “2”.: Initial Data
    1ST DATA
    2ND DATA
    DATA FUNCTION
    1995 04/11 17:20 MON
    NO. 220
    CODE 1  1
    CODE 2  2
    CODE 3  2
    CODE 4  1
    1995 04/11 17:20 MON
    NO. 220
    CODE 1
    QUANTITY 2
    CODE 2
    QUANTITY 1 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 94
    Revision 2.0
    CMD003
    COMMAND CODE
    TITLE:
    TIME BLOCK ASSIGNMENT
    D003
    4. DATA TABLE:
    1. FUNCTION:
    This command is used to determine the Maximum number of Call Records for SMDR.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    1ST DATA
    2ND DATA
    DATA FUNCTION
    29 Maximum number of Call Record for SMDR 0 : No limitation
    1:1 call
    12000 : 12000 calls
    STDE + D003 + ++DE
    (1-5 digits)  2ND DATA
    + + EXE(2 digits)  1ST DATA
    ~
    ~
    [CMD003] Time Block Assignment 
    						
    							ND-45669 (E) CHAPTER 3
    Addendum-001 Page 395
    AUGUST, 1998 Revision 2.1
    CMD004
    COMMAND CODE
    TITLE:
    OFFICE NUMBER ASSIGNMENT
    D004
    4. DATA TABLE:
    Note:If using a leading digit(s) of 0 and 0 is required to print at the host terminal, enter “A” for each leading 0 to be
    printed. If the leading digit(s) 0 is not required to print at the host terminal, enter “0”.
    1. FUNCTION:
    This command is used to assign the office number of the calling party and the office number of the bill-
    ing office for centralized billing.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    1ST DATA
    2ND DATA
    DATA FUNCTION
    55 Assignment of office number of calling party
    The office number is output to SMDR when the office num-
    ber of calling party is not sent from the local office of the call-
    ing party.
    NoteX - XXXX: Office No. of calling party
    56 Assignment of office number of billing office
    NoteX - XXXX: Office No. of billing office
    ST  +  D004  +  DE  +1ST DATA
    (1 - 2 digits)+  DE  +2ND DATA
    (1 - 4 digits)+  EXE
    [CMD004] Office Number Assignment 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 96
    Revision 2.0
    CMD012
    COMMAND CODE
    TITLE:
    STATION GROUP NUMBER
    D012
    4. DATA TABLE:
    Note:Assign Group Number 128 to stations in which a Group Number is not assigned.
    1. FUNCTION:
    By CMD012, a Group Number is to be assigned to each station for sending the tenant information (01-
    63) to the SMDR Terminal.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    1ST DATA 2ND DATA REMARKS
    X-XXXX : Station Number
    (1-4 digits)
    00-07 : ATTCON Number
    (2 digits)XXX: Group Number
    (001-063)
     + D012 +   +   +   +   + 
    STDE1ST DATA
    (1-4 digits)DE2ND DATA
    (3 digits)EXE
    [CMD012] Station Group Number 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 97
    Revision 2.0
    CMD015
    COMMAND CODE
    TITLE:
    STATION SERVICE CLASSES
    D015
    4. DATA TABLE:
    1. FUNCTION:
    This command is used to assign the class of service to each station and ATTCON.  The class functions
    are assigned by CMD016.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    1ST DATA 2ND DATA REMARKS
    X-XXXX : Station Number 
    (1 - 4 digits)
    00 - 07 : ATTCON Number
    (2 digits)XXX : Group Number
    (001-053)
    ST  +  D015  +  DE  +1ST DATA
    (1 - 4 digits)+  DE  +2ND DATA
    (2 digits)+  EXE
    [CMD015] Station Service Classes 
    						