CHAPTER 3 ND-45669 (E) Pag e 3 58 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT : Initial Kind (Upper digit) 1: Program address information 2: Receive command information F: No system initialized related information : Initial Kind (Lower digit) 0: Power On Initialize 1: Initialize by Reset key 2: Major Alarm 1 3: Major Alarm 2 4: Not Used 5: Major Alarm 3 6: Major Alarm 4 7: Major Alarm 5 8: Major Alarm 6 9: Initialize by SENS SW selection A: Major Alarm 7 B: Initialize from CAT/MAT C: Not Used D: Not Used E: Not Used F: Not Used 18 FP/AP No. 6 19 Power Fail- ure Kind 1 8Power Fail- ure Kind 2 8Power Fail- ure Kind 3 8 30 Fault Detail Kind 9 31 D-channel circuit No. 10 32 CCH No. 11 35 36 DLC Fail- ure Kind LEN Station Number FAU LT KIND NUMBER56789101112 1 2 1413 12
ND-45669 (E) CHAPTER 3 Pag e 3 59 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT : System Initialization related information The address of the program which caused system initialization. Note that, when the program which caused initialization is lpdi, the receive command (4 bytes from the head) is stored. This informa- tion is output in the case of system initialization only when the initial kind in 14 is 02, 03, 06, or 0A. : Stack Kind (Lower digit) 0: The number of registrations into H-rank stack was over 16. 1: The number of registrations into L-rank stack was over 48. : Communication Failure Kind (Lower digit) 0: Overflow of the buffer for data sending from MP to FP/AP. : FP/AP Number (Lower digit) 0–3: FP No. 0–3 4–F: AP Card No. 4–15 : Power Failure Kind 00: AC input failure 01: Fuse break 02: PWR alarm : Power Failure Restoration Kind 00: Restoration from AC input failure 01: Restoration from fuse break 02: Restoration from PWR alarm : Fault Kind Detail (Lower digit) 0: PCM Loss 1: Frame loss 2: Multiframe loss 3: Not used 4: Remote alarm 5: Not used 6: S-bit error 7: Not used 8: CRC error 9: Slip detected3 4 5 6 7 8 9
CHAPTER 3 ND-45669 (E) Pag e 3 60 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT A: Not used B: Not used C: Not used D: Not used E: Not used F: Not used : D-channel circuit No. • DCH: 00=Channel No. 0 : CCH No. 0–3: CCH No. : DLC Failure Kind 00: Terminal was cut off 02: Short circuit was made on the line 03: A wire was grounded 04: B wire was grounded or terminal was unconnected 05: Terminal failure 08: Terminal circuit failure : LEN (0000-0511) : Station No. (X-XXXX) 10 11 12 13 14
ND-45669 (E) CHAPTER 3 Pag e 3 61 Revision 2.0 CMEC COMMAND CODE TITLE: BATTERY RELEASE/LINE STATUS DISPLAY EC 4. DATA TABLE: 1. FUNCTION: This command is used for maintenance of the PBX. The functions of this command are outlined below: • Battery release • Line status display for single line telephone or Multiline Terminal 2. PRECAUTION: (1) See Line Status Display in the following pages for details on how to read the status information. (2) Line status display of a single line should not be performed while the single line is in use. (3) Line status display is not available in off-line. 3. ASSIGNMENT PROCEDURE: Y 1S T DATA 2 ND DATA RELATED COMMAND No. MEANING DATA MEANING DATA MEANING 0 Battery release 00 — 0 1Available Not available 1 Line status display [See Line Status Dis- play]X XXXXSingle Line Station Number or Primary Extension Number X = 0 - 9, A(*),B(#)—— ST + ECY + DE +1ST DATA (1 - 4 digits)+ DE +2ND DATA (0/1)+ EXE ~ [CMEC] Battery Release/Line Status Display
CHAPTER 3 ND-45669 (E) Pag e 3 62 Revision 2.0 CMEC COMMAND CODE TITLE: BATTERY RELEASE/LINE STATUS DISPLAY EC n Line Status Display Operation : Explanation of Screen Information: (a) Station Number : X-XXXX (1-4 digits) (b) Analog Line/Digital Line 00: LC (Single Line Tel.) 10: DLC (Multiline Terminal) (c) Hardware Test (d) Software Test 01: Idle 02: Line Lockout Other than 01, 02: Busy INDICATION STATUS OF SINGLE LINE TEL.STATUS OF MULTILINE TERMINALREMARKS 00 Terminal is not connected Terminal is not connected or tip wire is grounded 01 Terminal is connected Terminal is connected 02 Loop (Short circuit is made on the line) Short circuit is made on the line 03 Ring wire is grounded Ring wire is grounded 04 LC card is not mounted DLC card is not mounted 05 Test busy Terminal failure 06 — DLC card down 07 — — 08 — Line failure detect ST DE DECOMMAND= ECI> XXXX : XX XX XX XXXX : XX XX XX ECI+ X - XXXX + (Station No.) (a) (b) (c) (d)
ND-45669 (E) CHAPTER 3 Pag e 3 63 Revision 2.0 CMEE COMMAND CODE TITLE: VIRTUAL TIE LINE SET/RELEASE EE 4. DATA TABLE: 1. FUNCTION: This command sets/releases the virtual tie line (Event Based CCIS) from a MAT. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: + EEY + + + + + : Initial Data Y Y 1S T DATA 2ND DATA RELATED COMMAND No. MEANING DATA MEANING DATA MEANING 1 Virtual tie line set/ releaseXXXX Trunk No. of oppo- site office assigned by CM30 YY = 190 1Set ReleaseCM30 YY = 19 STDE1ST DATA (1-4 digits)DE2ND DATA (0/1)EXE [CMEE] Virtual Tie Line Set/Release
CHAPTER 3 ND-45669 (E) Pag e 3 64 Revision 2.0 CME1, F0, F1 COMMAND CODE TITLE: SPECIAL COMMANDS E1, F0, F1 1. FUNCTION: These commands are used only for maintenance. DO NOT USE these commands without the assistance of a NEC engineer. (1) MP Memory Check Sum Display (CME1 Y=0) The following shows the steps for displaying check sums using the CAT Note 1:XX: 01-04 (MP Memory Area Number) Note 2:YYYY: 0000-FFFF (Check Sum) (2) MP Memory Dump (CMF0) The following shows the steps for performing a memory read using the CAT. Note 1:Z: 0-F (Segment) Note 2:XXXX: 0000-FFFF (Address) Note 3:YY: 00-FF (Data) Note 4:This command is used only for memory display and cannot be used for memory changing. (3) MP Memory Read/Write (CMF1)Note 1 The following shows the steps for changing memory using the CAT. Note 1:Use extreme care when using this command while the system is in service. Note 2:Z: 0-F (Segment) Note 3:XXXX: 0000-FFFF (Address) STDEDE ++E10 + +XX Note 1 ---------- Display Data YYYY Note 2 STDEDE ++F0 + +ZXXXX Address Note 1, 2 Display XXXX: YYYYYYYY Designated AddressData of the designated address + 3 Data of the designated address + 2 Data of the designated address + 1 Data of the designated address STDEDE ++F1 + +ZXXXX Address Note 2, 3 +XX+EXE New Data [CME1, F0, F1] Special Commands
ND-45669 (E) CHAPTER 3 Pag e 3 65 Revision 2.0 CMF2, F3 COMMAND CODE TITLE: SPECIAL COMMANDS F2, F3 (4) FP Memory Dump (CMF2) The following shows the steps for performing a memory read using the CAT. Note 1:Y: 0-F (FP Number) Note 2:Z: 0-F (Segment) Note 3:XXXX: 0000-FFFF(Address) Note 4:YY: 00-FF (Data) (5) FP Memory Read/Write (CMF3)Note 1 The following shows the steps for changing memory using the CAT. Note 1:Use Extreme care when using this command while the system is in service. Note 2:Y: 0-F (FP Number) Note 3:Z: 0-F (Segment) Note 4:XXXX: 0000-FFFF (Address) STDEDE ++F2 + +YZXXXX Address Note 1, 2 Display XXXX: YYYYYYYY Designated AddressData of the designated address + 3 Data of the designated address + 2 Data of the designated address + 1 Data of the designated address Note 3 Note 4 STDEDE ++F3 + +YZXXXX Address Note 2, 3, 4 +XX+EXE New Data [CMF2, F3] Special Commands
CHAPTER 3 ND-45669 (E) Pag e 3 66 Revision 2.0 CMF5 COMMAND CODE TITLE: SPECIAL COMMANDS F5 (6) Line/Trunk Memory/Alarm Memory Read (CMF5) The following shows the steps for performing a memory read using the MAT/CAT. Y1ST DATAREADOUT DATA (STATUS INFORMATION)REMARKS 0X XXXXSingle Line Station/Virtual Line Station Number (1-4 digits) X=0-9, A(*), B(#)Status of Station/Trunk FX FXXXXMultiline Terminal Number represents Primary Extension Number D000 D255Trunk Number 2X XXXXSingle Line Station/Virtual Line Station Number (1-4 digits) X-0-9, A(*), B(#)LEN Number X FXXXMultiline Terminal Number represents Primary Extension Number D000 D255Trunk Number 3 000 003 004Memory Dump Data Reason for initialization MP initialization time FP initialization time STDEDE ++F5Y + +1ST DATA ~ ~ ~ ~ ~ ~ [CMF5] Special Commands
ND-45669 (E) CHAPTER 3 Pag e 3 67 Revision 2.0 CMF5 COMMAND CODE TITLE: SPECIAL COMMANDS F5 Note 1:A status information associated with Y = 0, 3 will be displayed as shown below. For the meaning of the status information displayed, refer to the Maintenance Manual. Note 2:Status information associated with Y = 2 will be displayed as shown below: Display F52 > X - XXXX : YYYY - /ZZZZ - or F52 > FX - FXXXX: YYYY - or F52 > D000 - D255 : YYYY - YYYY : 0000 - 0511 (LEN) ZZZZ : 0000 - 0255 (Virtual LEN) Display XXXX:YY YY YY YY Data of the designated Address + 3 Data of the designated Address + 2 Data of the designated Address + 1 Data of the designated Address XXXX: 0000 — FFFF (Address) YY = 00 — FF (Data)Designated Address