    							CHAPTER 3 ND-45669 (E)
    Pag e 3 58
    Revision 2.0
    CMEA
    COMMAND CODE
    TITLE:
    FAULT INFORMATION STORE/DISPLAY FUNCTIONS
    EA
    MAT
    : Initial Kind (Upper digit)
    1: Program address information
    2: Receive command information
    F: No system initialized related information
    : Initial Kind (Lower digit)
    0: Power On Initialize
    1: Initialize by Reset key
    2: Major Alarm 1
    3: Major Alarm 2
    4: Not Used
    5: Major Alarm 3
    6: Major Alarm 4
    7: Major Alarm 5
    8: Major Alarm 6
    9: Initialize by SENS SW selection
    A: Major Alarm 7
    B: Initialize from CAT/MAT
    C: Not Used
    D: Not Used
    E: Not Used
    F: Not Used
    18 FP/AP No.
    6
    19 Power Fail-
    ure Kind 1
    8Power Fail-
    ure Kind 2
    8Power Fail-
    ure Kind 3
    8
    30 Fault Detail 
    Kind 9
    31 D-channel 
    circuit No.
    10
    32 CCH No.
    11
    35
    36 DLC Fail-
    ure Kind LEN Station Number FAU LT  
    KIND 
    NUMBER56789101112
    1
    2
    1413
    12 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 59
    Revision 2.0
    CMEA
    COMMAND CODE
    TITLE:
    FAULT INFORMATION STORE/DISPLAY FUNCTIONS
    EA
    MAT
    : System Initialization related information
    The address of the program which caused system initialization. Note that, when the program which
    caused initialization is lpdi, the receive command (4 bytes from the head) is stored. This informa-
    tion is output in the case of system initialization only when the initial kind in 14 is 02, 03, 06, or
    0A.
    : Stack Kind (Lower digit)
    0: The number of registrations into H-rank stack was over 16.
    1: The number of registrations into L-rank stack was over 48.
    : Communication Failure Kind (Lower digit)
    0: Overflow of the buffer for data sending from MP to FP/AP.
    : FP/AP Number (Lower digit)
    0–3:  FP No. 0–3
    4–F:  AP Card No. 4–15
    : Power Failure Kind
    00:  AC input failure
    01:  Fuse break
    02:  PWR alarm
    : Power Failure Restoration Kind
    00:  Restoration from AC input failure
    01:  Restoration from fuse break
    02:  Restoration from PWR alarm
    : Fault Kind Detail (Lower digit)
    0: PCM Loss
    1: Frame loss
    2: Multiframe loss
    3: Not used
    4: Remote alarm
    5: Not used
    6: S-bit error
    7: Not used
    8: CRC error
    9: Slip detected3
    4
    5
    6
    7
    8
    9 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 60
    Revision 2.0
    CMEA
    COMMAND CODE
    TITLE:
    FAULT INFORMATION STORE/DISPLAY FUNCTIONS
    EA
    MAT
    A: Not used
    B: Not used
    C: Not used
    D: Not used
    E: Not used
    F: Not used
    : D-channel circuit No.
    • DCH:  00=Channel No. 0
    : CCH No.
    0–3:  CCH No.
    : DLC Failure Kind
    00: Terminal was cut off
    02: Short circuit was made on the line
    03: A wire was grounded
    04: B wire was grounded or terminal was unconnected
    05: Terminal failure
    08: Terminal circuit failure
    : LEN (0000-0511)
    : Station No. (X-XXXX)
    10
    11
    12
    13
    14 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 61
    Revision 2.0
    CMEC
    COMMAND CODE
    TITLE:
    BATTERY RELEASE/LINE STATUS DISPLAY
    EC
    4. DATA TABLE:
    1. FUNCTION:
    This command is used for maintenance of the PBX. The functions of this command are outlined below:
    •  Battery release
    •  Line status display for single line telephone or Multiline Terminal
    2. PRECAUTION:
    (1) See Line Status Display in the following pages for details on how to read the status information.
    (2) Line status display of a single line should not be performed while the single line is in use.
    (3) Line status display is not available in off-line.
    3. ASSIGNMENT PROCEDURE:
    Y 1S T  DATA 2 ND DATA
    RELATED
    COMMAND
    No. MEANING DATA MEANING DATA MEANING
    0 Battery release 00 — 0
    1Available
    Not available
    1 Line status display
    [See Line Status Dis-
    play]X
    XXXXSingle Line Station 
    Number or Primary 
    Extension Number
    X = 0 - 9, A(*),B(#)——
    ST   +   ECY   +   DE   +1ST DATA
    (1 - 4 digits)+   DE   +2ND DATA
    (0/1)+   EXE
    ~
    [CMEC] Battery Release/Line Status Display 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 62
    Revision 2.0
    CMEC
    COMMAND CODE
    TITLE:
    BATTERY RELEASE/LINE STATUS DISPLAY
    EC
    n  Line Status Display
    Operation : 
    Explanation of Screen Information:
    (a)  Station Number : X-XXXX (1-4 digits)
    (b) Analog Line/Digital Line
    00: LC (Single Line Tel.)
    10: DLC (Multiline Terminal)
    (c) Hardware Test
    (d) Software Test
    01: Idle
    02: Line Lockout
    Other than 01, 02: Busy
    INDICATION STATUS OF SINGLE LINE TEL.STATUS OF MULTILINE 
    TERMINALREMARKS
    00 Terminal is not connected Terminal is not connected or tip wire is 
    grounded
    01 Terminal is connected Terminal is connected
    02 Loop (Short circuit is made on the line) Short circuit is made on the line
    03 Ring wire is grounded Ring wire is grounded
    04 LC card is not mounted DLC card is not mounted
    05 Test busy Terminal failure
    06 — DLC card down
    07 — —
    08 — Line failure detect
    ST
    DE
    DECOMMAND=
    ECI>
    XXXX : XX XX XX XXXX : XX XX XX ECI+
    X - XXXX +
    (Station No.)
    (a) (b) (c) (d) 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 63
    Revision 2.0
    CMEE
    COMMAND CODE
    TITLE:
    VIRTUAL TIE LINE SET/RELEASE
    EE
    4. DATA TABLE:
    1. FUNCTION:
    This command sets/releases the virtual tie line (Event Based CCIS) from a MAT.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
     + EEY +   +   +   +   + 
    : Initial Data
    Y Y 1S T DATA 2ND DATA
    RELATED 
    COMMAND
    No. MEANING DATA MEANING DATA MEANING
    1 Virtual tie line set/
    releaseXXXX Trunk No. of oppo-
    site office assigned 
    by CM30 YY = 190
    1Set
    ReleaseCM30 YY = 19
    STDE1ST DATA
    (1-4 digits)DE2ND DATA
    (0/1)EXE
    [CMEE] Virtual Tie Line Set/Release 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 64
    Revision 2.0
    CME1, F0, F1
    COMMAND CODE
    TITLE:
    SPECIAL COMMANDS
    E1, F0, F1
    1. FUNCTION:
    These commands are used only for maintenance. DO NOT USE these commands without the assistance of
    a NEC engineer.
    (1) MP Memory Check Sum Display (CME1 Y=0)
    The following shows the steps for displaying check sums using the CAT
    Note 1:XX: 01-04 (MP Memory Area Number)
    Note 2:YYYY: 0000-FFFF (Check Sum)
    (2) MP Memory Dump (CMF0)
    The following shows the steps for performing a memory read using the CAT.
    Note 1:Z: 0-F (Segment)
    Note 2:XXXX: 0000-FFFF (Address)
    Note 3:YY: 00-FF (Data)
    Note 4:This command is used only for memory display and cannot be used for memory changing.
    (3) MP Memory Read/Write (CMF1)Note 1
    The following shows the steps for changing memory using the CAT.
    Note 1:Use extreme care when using this command while the system is in service.
    Note 2:Z: 0-F (Segment)
    Note 3:XXXX: 0000-FFFF (Address)
    STDEDE
    ++E10 + +XX
    Note 1
    ---------- Display Data YYYY
    Note 2
    STDEDE
    ++F0 + +ZXXXX
    Address
    Note 1, 2
    Display XXXX: YYYYYYYY
    Designated
    AddressData of the designated address + 3
    Data of the designated address + 2
    Data of the designated address + 1
    Data of the designated address
    STDEDE
    ++F1 + +ZXXXX
    Address
    Note 2, 3
    +XX+EXE
    New Data
    [CME1, F0, F1] Special Commands 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 65
    Revision 2.0
    CMF2, F3
    COMMAND CODE
    TITLE:
    SPECIAL COMMANDS
    F2, F3
    (4) FP Memory Dump (CMF2)
    The following shows the steps for performing a memory read using the CAT.
    Note 1:Y: 0-F (FP Number)
    Note 2:Z: 0-F (Segment)
    Note 3:XXXX: 0000-FFFF(Address)
    Note 4:YY: 00-FF (Data)
    (5) FP Memory Read/Write (CMF3)Note 1
    The following shows the steps for changing memory using the CAT.
    Note 1:Use Extreme care when using this command while the system is in service.
    Note 2:Y: 0-F (FP Number)
    Note 3:Z: 0-F (Segment)
    Note 4:XXXX: 0000-FFFF (Address)
    STDEDE
    ++F2 + +YZXXXX
    Address
    Note 1, 2
    Display XXXX: YYYYYYYY
    Designated
    AddressData of the designated address + 3
    Data of the designated address + 2
    Data of the designated address + 1
    Data of the designated address
    Note 3 Note 4
    STDEDE
    ++F3 + +YZXXXX
    Address
    Note 2, 3, 4
    +XX+EXE
    New Data
    [CMF2, F3] Special Commands 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 66
    Revision 2.0
    CMF5
    COMMAND CODE
    TITLE:
    SPECIAL COMMANDS
    F5
    (6) Line/Trunk Memory/Alarm Memory Read (CMF5)
    The following shows the steps for performing a memory read using the MAT/CAT.
    Y1ST DATAREADOUT DATA
    (STATUS INFORMATION)REMARKS
    0X
    XXXXSingle Line Station/Virtual Line Station 
    Number (1-4 digits) X=0-9, A(*), B(#)Status of Station/Trunk
    FX
    FXXXXMultiline Terminal Number  
    represents Primary Extension Number
    D000
    D255Trunk Number
    2X
    XXXXSingle Line Station/Virtual Line Station 
    Number (1-4 digits) X-0-9, A(*), B(#)LEN Number
    X
    FXXXMultiline Terminal Number  
    represents Primary Extension Number
    D000
    D255Trunk Number
    3 000
    003
    004Memory Dump Data Reason for initialization
    MP initialization time
    FP initialization time
    STDEDE
    ++F5Y + +1ST DATA
    ~ ~ ~ ~ ~ ~
    [CMF5] Special Commands 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 67
    Revision 2.0
    CMF5
    COMMAND CODE
    TITLE:
    SPECIAL COMMANDS
    F5
    Note 1:A status information associated with Y = 0, 3 will be displayed as shown below.
    For the meaning of the status information displayed, refer to the Maintenance Manual.
    Note 2:Status information associated with Y = 2 will be displayed as shown below:
    Display F52 > X - XXXX : YYYY - /ZZZZ -
    or
    F52 > FX - FXXXX: YYYY -
    or
    F52 > D000 - D255 : YYYY -
    YYYY : 0000 - 0511 (LEN)
    ZZZZ : 0000 - 0255 (Virtual LEN)
    Display XXXX:YY YY YY YY
    Data of the designated Address + 3
    Data of the designated Address + 2
    Data of the designated Address + 1
    Data of the designated Address
    XXXX: 0000 — FFFF (Address)
    YY = 00 — FF (Data)Designated