    C M 42
    4.  DATA  T A BLE :
    KIN D OF  SY STE M  COU NTER
    ~
    ~
    ~
    ~
    ~
    ~
    ~
    ~
    ~ 
    						
    							ND -4 5669 ( E)  CHAPTER 3
    CM 42
    Note 1 :No “Lo ckou t A la rm  Di sp lay”  fu nctio n if thi s da ta  is  no t a ssign ed.
    K IND  O F SYS TEM COUN TER
    ~
    ~
    ~
    ~
    ~ 
    						
    							CHAPTER 3 ND-45669 (E)
    Page 199-1 Addendum-001
    Revision 2.1 AUGUST, 1998
    CM42
    COMMAND CODE TITLE:
    SYSTEM COUNTER DATA/PAD DATA/TRUNK RESTRICTION CLASS
    CONVERSION 42
    4.2 PAD Data (Programmable)
    PAD DATA PATTERNS
    CONNECTING PATTERNS
    (A – B)
    CM35 YY=19
    2ND DATA=0CM35 YY=19
    2ND DATA=1CM35 YY=19
    2ND DATA=2CM35 YY=19
    2ND DATA=3
    50
    6550 54 58 62 STA – COT/ODT
    51 55 59 63 TONE – COT/ODT
    52 56 60 64 COT – COT/ODT
    53 57 61 65 ODT/DTI – COT/ODT
    50 54 58 62 STA/TONE – DTI
    51 55 59 63 COT – DTI
    52 56 60 64 ODT – DTI
    53 57 61 65 DTI – DTI
    PAT T E R N
    1ST DATA
    ~ 
    						
    							THIS PAGE INTENTIONALLY LEFT BLANK.
    ND-45669 (E) CHAPTER 3
    Addendum-001 Page 199-2
    AUGUST, 1998 Revision 2.1
    This page is for your notes. 
    						
    							CHAPTER 3 ND-45669 (E)
    Page 200 Addendum-002
    Revision 2.2 JANUARY, 1999
    CM42
    COMMAND CODE TITLE:
    SYSTEM COUNTER DATA/PAD DATA/TRUNK RESTRICTION CLASS
    CONVERSION 42
    T/R: Transmit/Receive
    +: Gain
    -: Loss
    PAD DATA OF B TRUNK (T/R) [dB]
    REMARKS
    ODT
    (4W E&M)ODT
    (2W E&M)COT/DID DTI
    00
    1500 0/0 0/0 0/0 0/0
    01 0/0 0/0 0/0 -2/-2
    02 0/0 0/0 0/0 -3/-3
    03 -2/-2 -3/-3 -3/-3 0/-6
    04 -3/-3 0/0 0/0 -3/-8
    05 -12/-11 -6/-6 -6/-6 +3/-3
    06 -16/-11 0/0 0/+5 -6/-6
    07 -6/-6 0/0 +3/+3 -8/-8
    08
    15Not UsedPATTERNS
    2ND DATA
    ~
    ~ 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 2 01
    Revision 2.0
    CM42
    COMMAND CODE TITLE:
    SYSTEM COUNTER DATA/PAD DATA/TRUNK RESTRICTION CLASS
    CONVERSION 42
    4.3 Trunk Restriction Class Conversion (PBX ICS)
    1 ST  DATA 2 ND DATA
    REMARKS
    DATA MEANING DATA MEANING
    20 NEAX2000 IVS Trunk Rest.
    Class 1 (RCA)00
    15NEAX2400 IMS Trunk Rest.
    Class (0 - 15)
    21 NEAX2000 IVS Trunk Rest.
    Class 2 (RCB)
    22 NEAX2000 IVS Trunk Rest.
    Class 3 (RCC)
    23 NEAX2000 IVS Trunk Rest.
    Class 4 (RCD)
    24 NEAX2000 IVS Trunk Rest.
    Class 5 (RCE)
    25 NEAX2000 IVS Trunk Rest.
    Class 6 (RCF)
    26 NEAX2000 IVS Trunk Rest.
    Class 7 (RCG)
    27 NEAX2000 IVS Trunk Rest.
    Class 8 (RCH)
    30 NEAX2400 Trunk Rest. Class 0 01
    08NEAX2000 IVS Trunk Rest.
    Class (1 - 8)
    31 NEAX2400 Trunk Rest. Class 1
    32 NEAX2400 Trunk Rest. Class 2
    33 NEAX2400 Trunk Rest. Class 3
    34 NEAX2400 Trunk Rest. Class 4
    35 NEAX2400 Trunk Rest. Class 5
    36 NEAX2400 Trunk Rest. Class 6
    37 NEAX2400 Trunk Rest. Class 7
    38 NEAX2400 Trunk Rest. Class 8
    39 NEAX2400 Trunk Rest. Class 9
    40 NEAX2400 Trunk Rest. Class 10
    41 NEAX2400 Trunk Rest. Class 11
    42 NEAX2400 Trunk Rest. Class 12
    43 NEAX2400 Trunk Rest. Class 13
    44 NEAX2400 Trunk Rest. Class 14
    45 NEAX2400 Trunk Rest. Class 15
    ~
    NEAX2000 IVS
    NEAX2400 IMS
    ~
    NEAX2400 IMS
    NEAX2000 IVS 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 2 02
    Revision 2.0
    CM42
    COMMAND CODE TITLE:
    SYSTEM COUNTER DATA/PAD DATA/TRUNK RESTRICTION CLASS
    CONVERSION 42
    Note 1:Initial Data in the Data Table represents the value for the data “NONE”. In this case, the fol-
    lowing conversion is performed in the Deluxe Traveling Class Mark-CCIS.
    (1) NEAX2400 to NEAX2000 IVS
    (2) NEAX2000 IVS to NEAX2400
    Note 2:This command should be used when changing the initial setting shown above, or when receiving
    the NEAX2400 Trunk Restriction Class (9 – 15) as a Deluxe Traveling Class Mark.
    NEAX2400
    TRK REST. CLASSNEAX2000 IVS
    TRK REST. CLASS
    0: OG via ATT
    1: Unrestricted-1
    2: Unrestricted-2
    3: Non-Restricted
    4: Semi-Restricted
    5: Restricted
    6: Fully-Restricted
    7: 
    8: 
     
    15:1: Unrestricted (RCA)
    1: Unrestricted (RCA)
    2: Non-Restricted-1 (RCB)
    3: Non-Restricted-2 (RCC)
    4: Semi-Restricted-1 (RCD)
    5: Semi-Restricted-2 (RCE)
    6: Restricted-1 (RCF)
    7: Restricted-2 (RCG)
    8:
    8:
    NEAX2000 IVS
    TRK REST. CLASSNEAX2400
    TRK REST. CLASS
    1: Unrestricted (RCA)
    2: Non-Restricted-1 (RCB)
    3: Non-Restricted-2 (RCC)
    4: Semi-Restricted-1 (RCD)
    5: Semi-Restricted-2 (RCE)
    6: Restricted-1 (RCF)
    7: Restricted-2 (RCG)
    8: Fully-Restricted (RCH)1: Unrestricted-1
    2: Unrestricted-2
    3: Non-Restricted
    4: Semi-Restricted
    5: Restricted
    6: Fully-Restricted
    7:
    8: Not Defined
    ~Fully-Restricted (RCH)~
    Not Defined 
    						
    							ND-45669 (E) CHAPTER 3
    Addendum-002 Page 203
    JANUARY, 1999 Revision 2.2
    CM44
    COMMAND CODE
    TITLE:
    EXTERNAL EQUIPMENT STARTING CONDITIONS
    44
    4. DATA TABLE:
    1. FUNCTION:
    This command assigns the relay (circuit number of the PN-DK00) used for controlling external equip-
    ment.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    CIRCUIT NUMBER
    RELATED
    COMMANDREMARKS
    NUMBER MEANING
    XXX XX
    X
     Circuit Number
    (0-3)
    Card Number
    (00-31)CM10
    Card number E8XX
    CIRCUIT
    ST + 44 + DE + NUMBER + DE + + + EXE
    (3 digits)D ATA  1
    (2 digits)D ATA  2
    (2 digits)
    [CM44] External Equipment Starting Conditions 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 2 04
    Revision 2.0
    CM44
    COMMAND CODE
    TITLE:
    EXTERNAL EQUIPMENT STARTING CONDITIONS
    44
    DATA 1 DATA 2
    RELATED
    COMMAND
    DATA MEANING DATA MEANING
    00 External Hold Tone Machine Start
    (TNT/COT Interface)00
    09External Hold Tone for Music On 
    HoldCM10
    (DA00-DA09)
    CM48
    01 External Announcement Machine Start
    (COT Interface)00 External Announcement Machine 
    for wake-up callingCM10
    CM48
    02 Speaker Paging Machine Start 00
    09Speaker Paging Zone 0
    Speaker Paging Zone 9CM30 YY = 28
    11 Indication for Trunk All Busy 01
    62Trunk Group 01
    Trunk Group 62CM30 YY = 09
    13 TAS Indication 00
    63TAS Group 00
    TAS Group 63CM30 YY = 17
    14 Indication for ACD/UCD call waiting 00
    15UCD Group 00
    UCD Group 15CM17
    CM59
    15 Relay Control Function Key 00 Relay Control (ON/OFF) via 
    Multiline TerminalCM90 YY = 00,
    F7XXX
    30 External Alarm driver function for the 
    SMDR buffer overflow01 Activates when buffer overflows 
    (when CMD001-80/100/120 is set 
    to “4”.)CMD001-80/100/120
    02 Activates when buffer overflows 
    (when CMD001-80/100/120 is set 
    to “5”.)
    35 No. 7 CCIS Link Alarm Display XX CM06 YY = 07
    36 No. 7 CCIS Day/Night Status Display 
    when the day/night mode change is 
    performed by the main office01 Tenant No.
    Note:An intraoffice attendant
    console should not be
    assigned for the tenant.
    ~
    ~~
    ~~
    ~~
    ~~
    XX
    CCH No. (00 - 03) 
    						
    							ND-45669 (E) CHAPTER 3
    Addendum-001 Page 205
    AUGUST, 1998 Revision 2.1
    CM45
    COMMAND CODE
    TITLE:
    PURPOSE OF PBR/CFT
    45
    1. FUNCTION:
    This command is used to define the presence and purpose of PB (DTMF) Receivers (PN-8RST) and
    conference trunks. This command is also used to make CFTs and PBRs busy.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    PBR/CFT
    ST + 45Y + DE + NUMBER + DE + + EXE
    (2-3 digits)DATA
    (1 digit)
    [CM45] Purpose of PBR/CFT 
    						