NEC Neax2000 Ivs Command Manual
Have a look at the manual NEC Neax2000 Ivs Command Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 3 ND-45669 (E) Pag e 4 08 Revision 2.0 CMD100 COMMAND CODE TITLE: SYSTEM DATA PARTIAL CLEAR D100 AP OFF LINE Note:Before clearing the system data by this command, make the following switch setting on the PN-AP00 card. 1. FUNCTION: This command is used to delete the data related only to the designated Command Code among the Sys- tem Data for Billing and for assigning “0” as the data. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: STDE + D100 + ++DE + +EXE DXXXCCC Command Code of the data to be deleted 4 3 2 1 SW1 ON : Position to be set [CMD100] System Data Partial Clear
ND-45669 (E) CHAPTER 3 Pag e 4 09 Revision 2.0 CMD101 COMMAND CODE TITLE: SYSTEM DATA ALL CLEAR D101 AP OFF LINE Note:Before clearing the system data by this command, make the following switch setting on the PN-AP00 card. 1. FUNCTION: This command is used to delete all the System Data for Billing and for assigning the initial data. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: STDE + D101 + ++DE + +EXE 0000 CCC 4 3 2 1 SW1 ON : Position to be set [CMD101] System Data All Clear
CHAPTER 3 ND-45669 (E) Pag e 4 10 Revision 2.0 CMD102 COMMAND CODE TITLE: ADDITIONAL MEMORY CLEAR D102 AP OFF LINE Note 1:By entering the 1st data “0000”, the status of the additional memory (SRAM card) will display as follows: Note 2:Before clearing system data by this command, make the following switch setting on the PN-AP00 card. 1. FUNCTION: When mounting additional memory (SRAM card), this command is used to delete its stored data. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: STDE + D102 + ++DE + +EXE 0000 CCC (4 digits) 0 : SRAM card was not mounted 1 : SRAM card was initialized 0 0 X 4 3 2 1 SW1 ON : Position to be set [CMD102] Additional Memory Clear
ND-45669 (E) CHAPTER 4 Page 411 Revision 2.0 RESIDENT SYSTEM PROGRAM CHAPTER 4 RESIDENT SYSTEM PROGRAM 1. GENERAL The resident system program generates system data automatically according to the system hardware configu- ration, thereby providing immediate operation and shorter programming time. When activated, the system scans hardware configuration (such as line/trunk card location) and assigns the system data (such as station numbers, trunk numbers, etc.) according to a predetermined generic program assignment. 2. PROCEDURE FOR LOADING THE RESIDENT SYSTEM PROGRAM STEP 1 Mount the cards on PIMs. STEP 2 Set SW3 of the MP card to “C”. STEP 3 Press SW1 of the MP card. STEP 4 Confirm the status of MJ/MN lamp on the PWR card. • When the MN lamp lights, the office data is normally registered. • When the MJ lamp lights, the office data is not normally registered. Repeat STEP 2 and STEP 3. STEP 5 Set SW3 of the MP card to “0”. STEP 6 P ress SW1 of the MP card. 3. SERVICE CONDITIONS (1) This service is applicable for equipment installed in PIM 0 through PIM 3. (2) Data for any vacant slot is not assigned. (3) Virtual stations are not assigned. (4) A line/trunk card (PN-AUCA/DK00/CFT) is not assigned, even if mounted. (5) An application card (PN-AP00/AP01/24DTA/SC00/SC01/ME00) is not assigned, even if mounted. (6) No tenant assignment is provided. (Tenant 01 is assigned) (7) Details of Resident System Program For the other commands which are not described in Table 4-1 through Table 4-11, the initial data is loaded by the Resident System Program.
CHAPTER 4 ND-45669 (E) Page 412 Addendum-002 Revision 2.2 JANUARY, 1999 RESIDENT SYSTEM PROGRAM 4. PROGRAMMED DATA TABLES • Basic Service Feature (CM08) The following data is assigned on a per service feature basis. Table 4-1 Basic Service Feature : Initial Data CM08 FEATURE No.DATA 0/1FEATURE No.DATA 0/1FEATURE No.DATA 0/1FEATURE No.DATA 0/1FEATURE No.DATA 0/1FEATURE No.DATA 0/1FEATURE No.DATA 0/1 012 1 050 1 101 1 150 1 221 1 264 1 379 1 014 051 102 0 151 1 222 1 265 380 018 055 103 0 153 0 227 1 267 381 021 056 104 1 155 1 228 0 268 382 1 025 057 109 1 156 0 232 1 269 390 0 026 058 110 157 1 233 0 270 391 1 028 062 111 158 234 1 271 394 029 063 1 112 161 235 1 274 400 032 067 1 113 162 1 236 1 280 401 035 068 0 115 163 0 237 1 281 403 036 069 1 116 165 1 238 282 405 040 076 119 168 239 283 450 043 094 123 171 241 284 451 1 044 095 124 172 244 286 045 096 1 125 176 245 287 048 1 128 177 246 293 130 178 1 250 294 133 179 0 251 311 135 180 1 252 319 136 181 253 322 137 183 254 324 138 185 255 331 139 187 259 333 141 193 262 1 334 142 194 352 143 199 353 145 200 357 146 201 359 147 204 361 148 205 362 149 1 206 1 363 208 0 366 212 1 369 214 370 215 371 216 372 217 1 378 1
ND-45669 (E) CHAPTER 4 Page 413 Revision 2.0 RESIDENT SYSTEM PROGRAM • Station Number, Trunk Number, Card Number (CM10) The following data is assigned according to the sequential slot location number of the associated circuit cards. Note:If the DSS Console is not connected to the system, though the PN-4DLC card is mounted in the slot, the data (F200-F455) for Multiline Terminal is assigned. Table 4-2 Station Number, Trunk Number, Card Number CARD PURPOSE ASSIGNED DATA REMARKS PN-4LC Single Line Telephone 200 – 455 Station Numbers 200 through 455 for Single Line Telephone and Multiline Terminal are assigned according to sequential slot location number of associated circuit card. SN610 ATTCON Numbers E004 through E007 are assigned according to sequential slot location number of associated circuit card. PN-4DLC PN-2DLCBMultiline Terminal F200 – F455 PN-2DLCC SN610 ATTCON E004 – E007 PN-4COT PN-2COT PN-2ODTTrunk D000 – D255 PN-8RST DTMF Receiver E200 – E203 (PIM0/1) E204 – E207 (PIM2/3) Consecutive card number beginning at 00 is assigned according to the sequential slot location number of the associated circuit cards. PN-2DAT Digital Announcement TrunkEB000 – EB031 (PIM0/1) EB032 – EB063 (PIM2/3) PN-CP03 DTMF Receiver E200 – E203
CHAPTER 4 ND-45669 (E) Page 414 Addendum-002 Revision 2.2 JANUARY, 1999 RESIDENT SYSTEM PROGRAM • Station Class Data (CM12, 13) The following data is assigned on a per station basis. Table 4-3 Station Class Data: Initial Data CM10 CM12 STATION No. TRUNK No. CARD No. (1–5 DIGITS)YY 00 01 02 03 04 05 07 12 13 16 0 2DAY NI GHT A B 00 1500 630/100 15x xxxx00 15D000 D255x xxxx 1 81 800 1500 15 31 1 15151501115 200 3 1 1 15 15 15 01 1 15 201 3 1 1 15 15 15 01 1 15 202 3 1 1 15 15 15 01 1 15 456 : Initial Data CM10 CM13 STATION No. TRUNK No. CARD No. (1–5 DIGITS)YY 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 21 22 23 29 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 11111111111111111111 200 11101111111111111111 201 11101111111111111111 202 11101111111111111111 456 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
ND-45669 (E) CHAPTER 4 Page 415 Revision 2.0 RESIDENT SYSTEM PROGRAM • Number Plan (CM20) The following data is assigned for access code of each service feature. Table 4-4 Numbering Plan CM20 Y (0–3) ACCESS CODE SETTING DATA SERVICE FEATURES 0 0 800 Operator Call 11 046 Call Hold 2, 3 or 4 803 First Digit of Three Digit Station Number 50 A30 Internal Zone Paging Group 0 For calling 51 A31 Group 1 52 A32 Group 2 53 A33 Group 3 54 A34 Group 4 55 A38 Internal Zone Paging Group 0 For answering 56 A39 Group 1 57 A40 Group 2 58 A41 Group 3 59 A42 Group 4 5* 024 Automatic Wake Up/Timed ReminderSet 5# 025 Cancel 60 A63 Voice Call/Ring Tone Programming 62 A10 Assignment of Station Name 66 039 BGM on Multiline Terminal Set/Reset 68 043 Day/Night Mode Change by Station Dialing 6* 008 Call Park-System Set 6# 009 Call Park-System Retrieve 72 047 TAS Answer A 73 021 Call Pickup – Direct 74 020 Call Pickup – Group 75 037 Call Pickup – Designated Group 7* 065 Station Speed Dialing Entry 7# 066 Cancel
CHAPTER 4 ND-45669 (E) Pag e 4 16 Revision 2.0 RESIDENT SYSTEM PROGRAM 0 9 100 Trunk Access Code RT00 81 101 RT01 82 102 RT02 83 104 RT04 84 105 RT05 85 106 RT06 86 107 RT07 87 081 Individual Trunk Access *1 004 Trunk Queuing – Outgoing Set #1 005 /Call Back Cancel *2 007 Camp-On by Station (Transfer Method) #2 A25 Camp-On by Station (Call Waiting Method) *4 006 Executive Override *5 010 Call Forwarding – All Calls Entry #5 011 Cancel *6 012 Call Forwarding – No Answer Entry #6 013 /Busy Line Cancel *7 018 Call Forwarding – Designation Entry #7 019 Cancel *8 022 Do Not Disturb Set #8 023 Cancel *9 040 MW Lamp Control Set #9 041 Reset ** 069 Last Number Redial *# 085 Account Code Entry #* 064 Station Speed Dialing Origination ## 067 System Speed Dialing OriginationTable 4-4 Numbering Plan (Continued) CM20 Y (0–3) ACCESS CODE SETTING DATA SERVICE FEATURES
ND-45669 (E) CHAPTER 4 Page 417 Revision 2.0 RESIDENT SYSTEM PROGRAM • Trunk Data (CM30) The following data is assigned according to the type of trunk card. Table 4-5 Trunk Data : Initial Data CM30 TYPE OF TRUNK CARDYY 00 01 02 03 04 05 07 08 09 13 14 15 00 6300 6300 3100 31X XXXX EBXXXX XXXX EBXXX000 0290/100 6200 1500 1500 15 01 31 31 1 15 15 15 PN-4COT 00 01 02 02 NONE NONE 1 NONE 15 15 15 PN-2ODT 02 01 31 31 NONE NONE 1 NONE 15 15 15