    							CHAPTER 3 ND-45669 (E)
    Pag e 4 08
    Revision 2.0
    CMD100
    COMMAND CODE
    TITLE:
    SYSTEM DATA PARTIAL CLEAR
    D100
    AP OFF LINE
    Note:Before clearing the system data by this command, make the following switch setting on the PN-AP00 card.
    1. FUNCTION:
    This command is used to delete the data related only to the designated Command Code among the Sys-
    tem Data for Billing and for assigning “0” as the data.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    STDE + D100 + ++DE + +EXE DXXXCCC
    Command Code of the data to be deleted
    4
    3
    2
    1 SW1
    ON
    : Position to be set [CMD100] System Data Partial Clear 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 4 09
    Revision 2.0
    CMD101
    COMMAND CODE
    TITLE:
    SYSTEM DATA ALL CLEAR
    D101
    AP OFF LINE
    Note:Before clearing the system data by this command, make the following switch setting on the PN-AP00 card.
    1. FUNCTION:
    This command is used to delete all the System Data for Billing and for assigning the initial data.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    STDE + D101 + ++DE + +EXE 0000 CCC
    4
    3
    2
    1 SW1
    ON
    : Position to be set [CMD101] System Data All Clear 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 4 10
    Revision 2.0
    CMD102
    COMMAND CODE
    TITLE:
    ADDITIONAL MEMORY CLEAR
    D102
    AP OFF LINE
    Note 1:By entering the 1st data “0000”, the status of the additional memory (SRAM card) will display
    as follows:
    Note 2:Before clearing system data by this command, make the following switch setting on the PN-AP00
    card.
    1. FUNCTION:
    When mounting additional memory (SRAM card), this command is used to delete its stored data.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    STDE + D102 + ++DE + +EXE 0000
    CCC
    (4 digits)
    0 : SRAM card was not mounted
    1 : SRAM card was initialized 0 0 X
    4
    3
    2
    1 SW1
    ON
    : Position to be set [CMD102] Additional Memory Clear 
    						
    							ND-45669 (E) CHAPTER 4
    Page 411
    Revision 2.0
    RESIDENT SYSTEM PROGRAM
    CHAPTER 4 RESIDENT SYSTEM PROGRAM
    1. GENERAL
    The resident system program generates system data automatically according to the system hardware configu-
    ration, thereby providing immediate operation and shorter programming time. When activated, the system
    scans hardware configuration (such as line/trunk card location) and assigns the system data (such as station
    numbers, trunk numbers, etc.) according to a predetermined generic program assignment.
    2. PROCEDURE FOR LOADING THE RESIDENT SYSTEM PROGRAM
    STEP 1 Mount the cards on PIMs.
    STEP 2 Set SW3 of the MP card to “C”.
    STEP 3 Press SW1 of the MP card.
    STEP 4 Confirm the status of MJ/MN lamp on the PWR card.
    • When the MN lamp lights, the office data is normally registered.
    • When the MJ lamp lights, the office data is not normally registered.   
    Repeat STEP 2 and STEP 3.
    STEP 5 Set SW3 of the MP card to “0”.
    STEP 6 P
    ress SW1 of the MP card.
    3. SERVICE CONDITIONS
    (1) This service is applicable for equipment installed in PIM 0 through PIM 3. 
    (2) Data for any vacant slot is not assigned.
    (3) Virtual stations are not assigned.
    (4) A line/trunk card (PN-AUCA/DK00/CFT) is not assigned, even if mounted.
    (5) An application card (PN-AP00/AP01/24DTA/SC00/SC01/ME00) is not assigned, even if mounted.
    (6) No tenant assignment is provided.
    (Tenant 01 is assigned)
    (7) Details of Resident System Program
    For the other commands which are not described in Table 4-1 through Table 4-11, the initial data is loaded
    by the Resident System Program. 
    						
    							CHAPTER 4 ND-45669 (E)
    Page 412 Addendum-002
    Revision 2.2 JANUARY, 1999
    RESIDENT SYSTEM PROGRAM
    4. PROGRAMMED DATA TABLES
    • Basic Service Feature (CM08)
    The following data is assigned on a per service feature basis.
    Table 4-1  Basic Service Feature
    : Initial Data
    CM08
    FEATURE 
    No.DATA  
    0/1FEATURE 
    No.DATA  
    0/1FEATURE
    No.DATA 
    0/1FEATURE
    No.DATA  
    0/1FEATURE
    No.DATA  
    0/1FEATURE 
    No.DATA 
    0/1FEATURE 
    No.DATA 
    0/1
    012 1 050  1 101 1 150 1 221 1 264 1 379 1
    014 051 102 0 151 1 222 1 265 380
    018 055 103 0 153 0 227 1 267 381
    021 056 104 1 155 1 228 0 268 382 1
    025 057 109 1 156 0 232 1 269 390 0
    026 058 110 157 1 233 0 270 391 1
    028 062 111 158 234 1 271 394
    029 063 1 112 161 235 1 274 400
    032 067 1 113 162 1 236 1 280 401
    035 068 0 115 163 0 237 1 281 403
    036 069 1 116 165 1 238 282 405
    040 076 119 168 239 283 450
    043 094 123 171 241 284 451 1
    044 095 124 172 244 286
    045 096 1 125 176 245 287
    048 1 128 177 246 293
    130 178 1 250 294
    133 179 0 251 311
    135 180 1 252 319
    136 181 253 322
    137 183 254 324
    138 185 255 331
    139 187 259 333
    141 193 262 1 334
    142 194 352
    143 199 353
    145 200 357
    146 201 359
    147 204 361
    148 205 362
    149 1 206 1 363
    208 0 366
    212 1 369
    214 370
    215 371
    216 372
    217 1 378 1 
    						
    							ND-45669 (E) CHAPTER 4
    Page 413
    Revision 2.0
    RESIDENT SYSTEM PROGRAM
    • Station Number, Trunk Number, Card Number (CM10)
    The following data is assigned according to the sequential slot location number of the associated circuit
    cards.
    Note:If the DSS Console is not connected to the system, though the PN-4DLC card is mounted in the slot, the
    data (F200-F455) for Multiline Terminal is assigned.
    Table 4-2  Station Number, Trunk Number, Card Number
    CARD PURPOSE ASSIGNED DATA REMARKS
    PN-4LC Single  Line  Telephone 200  –  455 Station Numbers 200 through 455 for Single Line 
    Telephone and Multiline Terminal are assigned 
    according to sequential slot location number of 
    associated circuit card.
    SN610 ATTCON Numbers E004 through E007 
    are assigned according to sequential slot location 
    number of associated circuit card. PN-4DLC
    PN-2DLCBMultiline Terminal F200 – F455
    PN-2DLCC SN610 ATTCON E004 – E007
    PN-4COT
    PN-2COT
    PN-2ODTTrunk D000 – D255
    PN-8RST DTMF Receiver E200 – E203 (PIM0/1)
    E204 – E207 (PIM2/3)
    Consecutive card number beginning at 00 is
    assigned according to the sequential slot location 
    number of the associated circuit cards. PN-2DAT Digital Announcement 
    TrunkEB000 – EB031
    (PIM0/1)
    EB032 – EB063
    (PIM2/3)
    PN-CP03 DTMF Receiver E200 – E203 
    						
    							CHAPTER 4 ND-45669 (E)
    Page 414 Addendum-002
    Revision 2.2 JANUARY, 1999
    RESIDENT SYSTEM PROGRAM
    • Station Class Data (CM12, 13)
    The following data is assigned on a per station basis.
    Table 4-3  Station Class Data: Initial Data
    CM10 CM12
    STATION No.
    TRUNK No.
    CARD No.
    (1–5 DIGITS)YY
    00 01 02 03 04 05 07 12 13 16
    0
    2DAY NI GHT A B
    00
    1500
    630/100
    15x
    xxxx00
    15D000
    D255x
    xxxx 1
    81
    800
    1500
    15
    31 1 15151501115
    200 3 1 1 15 15 15 01 1 15
    201 3 1 1 15 15 15 01 1 15
    202 3 1 1 15 15 15 01 1 15
    456
    : Initial Data
    CM10 CM13
    STATION No.
    TRUNK No.
    CARD No.
    (1–5 DIGITS)YY
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 21 22 23 29
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    11111111111111111111
    200 11101111111111111111
    201 11101111111111111111
    202 11101111111111111111
    456
    ~
    ~
    ~
    ~
    ~
    ~
    ~
    ~ ~
    ~
    ~
    ~ 
    						
    							ND-45669 (E) CHAPTER 4
    Page 415
    Revision 2.0
    RESIDENT SYSTEM PROGRAM
    • Number Plan (CM20)
    The following data is assigned for access code of each service feature.
    Table 4-4  Numbering Plan
    CM20
    Y (0–3) ACCESS CODE SETTING DATA SERVICE FEATURES
    0 0 800 Operator Call
    11 046 Call Hold
    2, 3 or 4 803 First Digit of Three Digit Station Number
    50 A30 Internal Zone Paging Group 0
    For calling 51 A31 Group 1
    52 A32 Group 2
    53 A33 Group 3
    54 A34 Group 4
    55 A38 Internal Zone Paging Group 0
    For answering 56 A39 Group 1
    57 A40 Group 2
    58 A41 Group 3
    59 A42 Group 4
    5* 024 Automatic Wake Up/Timed ReminderSet
    5# 025 Cancel
    60 A63 Voice Call/Ring Tone Programming
    62 A10 Assignment of Station Name
    66 039 BGM on Multiline Terminal Set/Reset
    68 043 Day/Night Mode Change by Station Dialing
    6* 008 Call Park-System Set
    6# 009 Call Park-System Retrieve
    72 047 TAS Answer A
    73 021 Call Pickup – Direct
    74 020 Call Pickup – Group
    75 037 Call Pickup – Designated Group
    7* 065 Station Speed Dialing Entry
    7# 066 Cancel 
    						
    							CHAPTER 4 ND-45669 (E)
    Pag e 4 16
    Revision 2.0
    RESIDENT SYSTEM PROGRAM
    0 9 100 Trunk Access Code RT00
    81 101 RT01
    82 102 RT02
    83 104 RT04
    84 105 RT05
    85 106 RT06
    86 107 RT07
    87 081 Individual Trunk Access
    *1 004 Trunk Queuing – Outgoing Set
    #1 005 /Call Back Cancel
    *2 007 Camp-On by Station (Transfer Method)
    #2 A25 Camp-On by Station (Call Waiting Method)
    *4 006 Executive Override
    *5 010 Call Forwarding – All Calls Entry
    #5 011 Cancel
    *6 012 Call Forwarding – No Answer Entry
    #6 013 /Busy Line Cancel
    *7 018 Call Forwarding – Designation Entry
    #7 019 Cancel
    *8 022 Do Not Disturb Set
    #8 023 Cancel
    *9 040 MW Lamp Control Set
    #9 041 Reset
    ** 069 Last Number Redial
    *# 085 Account Code Entry
    #* 064 Station Speed Dialing Origination
    ## 067 System Speed Dialing OriginationTable 4-4  Numbering Plan (Continued)
    CM20
    Y (0–3) ACCESS CODE SETTING DATA SERVICE FEATURES 
    						
    							ND-45669 (E) CHAPTER 4
    Page 417
    Revision 2.0
    RESIDENT SYSTEM PROGRAM
    • Trunk Data (CM30)
    The following data is assigned according to the type of trunk card.
    Table 4-5  Trunk Data
    :  Initial Data
    CM30
    TYPE OF 
    TRUNK 
    CARDYY
    00 01 02 03 04 05 07 08 09 13 14 15
    00
    6300
    6300
    3100
    31X
    XXXX
    EBXXXX
    XXXX
    EBXXX000
    0290/100
    6200
    1500
    1500
    15
    01 31 31 1 15 15 15
    PN-4COT 00 01 02 02 NONE NONE 1 NONE 15 15 15
    PN-2ODT 02 01 31 31 NONE NONE 1 NONE 15 15 15 
    						