CHAPTER 3 ND-45669 (E) Page 348 Addendum-002 Revision 2.2 JANUARY, 1999 CME5 COMMAND CODE TITLE: STATION, TRUNK LINE MAKE BUSY E5 4. DATA TABLE: Note 1:For a station that is made busy, call termination to the station is restricted, but Call origination is available. For extension lines on a Multiline Terminal, My Line and Multiline make busy can be set individually, with the same condition as mentioned above. Note 2:For a trunk that is made busy, the outgoing call is restricted, but on incoming, the call is available. Note 3:For the B channel that is made busy, call termination to the ISDN Terminal corresponds with the B channel is restricted, but call origination is available. Note 4:Under a made busy condition, the Busy Lamp on the card flashes (60 IPM). Note 5:Make idle of ZT since the ZT is in make busy forcibly when assigning the ZT data by CM10. 1. FUNCTION: This command is used to make busy any station or trunk in the software. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: : Initial Data YSTATION TRUNK NUMBER SETTING DATA REMARKS No. MEANING DATA MEANING 0X XXXXStation number (1-4 digits) Note 10 1Make Busy set In serviceFor LC, AUC, and DLC card 1 000 255Trunk number Note 20 1Make Busy set In serviceFor COT, LDT, ODT, 2BRT, and AUC card 2 XXXX X ISDN Circuit Station No. 0: B1 Channel 1: B2 Channel Note 30 1Make busy set In serviceFor ILC card 3 000 255ZT number 0 1 2Make busy (forced) Make idle Make busy (after calls finished)For ZT Note 5 STDEDEEXE ++E5Y + + + + (0/1) D ATA NUMBER STATION/TRUNK ~ ~ ~ ,
ND-45669 (E) CHAPTER 3 Addendum-002 Page 349 JANUARY, 1999 Revision 2.2 CME6 COMMAND CODE TITLE: CALL FORWARDING SET/RESET FROM MAT/CAT E6 4. DATA TABLE: Note:To reset Call Forwarding, assign “CCC” to the second data. 1. FUNCTION: This command sets/resets the Call Forwarding service to each station from a MAT/CAT. 2. PRECAUTION: CME6 can be used for any station irrespective of its state. 3. ASSIGNMENT PROCEDURE: + E6YY + + + + + YY MEANING DESTINATION No. 00 Call Forwarding-All Calls • Destination = Extension; X-XXXX: Station No. (1-4 digits) • Destination = Outside party; X-XX +,+YY...YY Called No. (Max. 26 digits) Separator Mark Outgoing Trunk/LCR Group Access Code (1-2 digits) • Destination = Attendant; E000 01 Call Forwarding-Busy Line 02 Call Forwarding-No Answer 03 Call Forwarding-Busy Line/ No Answer 04 Split Call Forwarding-All Calls 0: Target station for Split Call Forwarding (Block 0)/ATT 1: Target station for Split Call Forwarding (Block 1) 2: Target station for Split Call Forwarding (Block 2) 3: Target station for Split Call Forwarding (Block 3) 4: Target station for Split Call Forwarding (Block 4) 05 Split Call Forwarding-Busy Line/No Answer5: Target station for Split Call Forwarding (Block 5) 6: Target station for Split Call Forwarding (Block 6) 7: Target station for Split Call Forwarding (Block 7) 8: Target station for Call Forwarding 9: Station Speed Dialing (Block 0) STDESTATION No. (1-4 digits)DEDESTINATION No. (1-26 digits)CCC (for reset)EXE [CME6] Call Forwarding Set/Reset From MAT/CAT
CHAPTER 3 ND-45669 (E) Pag e 3 50 Revision 2.0 CME7 COMMAND CODE TITLE: PASSWORD LEVEL E7 4. DATA TABLE: Note:In case of YY = 20, 21, the data to be set is “1” only. 1. FUNCTION: This command specifies the accessible commands for each Password Level. 2. PRECAUTION: None 3. ASSIGNMENT PROCEDURE: : Initial Data YY COMMAND CODE SETTING DATA No. PASSWORD LEVEL 00 01 02 03 04 05 06 10 11 12 13 14 15 16Password Level 0 – 6 1 – 6 2 – 6 3 – 6 4 – 6 5 – 6 6 0 1 2 3 4 5 6XX: 00 – FF (Exclusive of 03, E7, E9)0: Allowed 1: Restricted 20 To clear all the Password Level settings for individual commandsXX: 00 – FF (Exclusive of 03, E7, E9)1: All Password Levels exclud- ing Level 7 are restricted from assignment of designated command. 21 To clear all the Password Level settings for all commandsXX: 00 1: All Password Levels exclud- ing Level 7 are restricted from assignment of all com- mands. ST + E7YY + DE +COMMAND CODE (2 digits)+ DE +D ATA (1 digit)+ EXE [CME7] Password Level
ND-45669 (E) CHAPTER 3 Pag e 3 51 Revision 2.0 CME9 COMMAND CODE TITLE: PASSWORD CODE E9 MAT 4. DATA TABLE: Note:Password Level 7 can access all the commands. 1. FUNCTION: This command is used to define the Password Code of each Password Level and the availability of Pass- word Service. 2. PRECAUTION: (1) Before setting the Password code, Function Number 8 (Change of Password) must be set to 0 (Allowed). (2) When programming a Password Code, the Password Code for Password Level 7 must be made. If no Password Code of Password Level 7 is set, the programming of Password Service provision (CME9, FUNCTION No. 9) is restricted with the message “CODE NOT USED”. Note (3) Function No. 9 (Password Service) must be set to 0 (Provided) after programming of all Password Codes is completed. 3. ASSIGNMENT PROCEDURE: : Initial Data PASSWORD LEVEL No. / FUNCTION No.SETTING DATA REMARKS DATA MEANING 0 7Password Level 0 Password Level 7X XX X . . . X (Max. 8 digits)Password Code Following Password Codes are not available: “CC . . . C” (All “C”) “FF . . . F” (All “F”) 8 Change of Password (Display of Password)0 1 Allowed Restricted 9Password Service 0 1 Provided Not provided ST + E9 + DE +PASSWORD LEVEL NO. /FUNCTION NO. (1 digit)+ DE + DATA + EXE ~~ ~ [CME9] Password Code
CHAPTER 3 ND-45669 (E) C M EA M AT 1. FUN CTIO N: ST + E AY + DE + [ C M EA ] Fau lt I nf orm ation Store /D isp lay F unct io n s
ND-45669 (E) CHAPTER 3 CM EA MAT : I n it ial Data ~
CHAPTER 3 ND-45669 (E) C M EA M AT 2 Regis tr atio n of fau lt ~
ND-45669 (E) CHAPTER 3 Pag e 3 55 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT n Fault Information Display After the following operation: The first screen displays on the MAT/CAT. The fault information is separated into four separate parts, and displayed on four screens. An example of fault information display is provided below: EXPLANATION OF SCREEN INFORMATION 1: Fault Occurrence Kind No./Fault Restoration Kind No. FAULT KIND NUMBERFAULT CONTENT 01 System initialized 03 The number of stack entries was more than the caution level 04 MP-FP/AP communication failure 08 FP-AP card down 09 Power failure 20 DTI line failure 21 DCH D-channel link connection failure 22 CCH link connection 25 The number of lockout stations was more than the predetermined number 26 DLC card down STDEDE EA0 00 ++++ 1st Screen2nd Screen 4th Screen3rd Screen DE DEDE 1 : 03 MN MP 00 12 3 91011124 5678 3 : xx xx xx xx 2 : 93/3/20 20 : 31 3 : xx xx xx xx to 1st screen of next data
CHAPTER 3 ND-45669 (E) Pag e 3 56 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT EXPLANATION OF SCREEN INFORMATION (Continued) 2: External Alarm Kind (MJ/MN/-) Use of External Alarm Kind - Minor (MN), Major (MJ) or external alarm is not provided (-) can be programmed by CMEA Y=2. The following table shows the standard data set by the 2nd data = 3 of CMEA Y=2. FAULT RESTORATION KIND NUMBERFAULT RESTORATION CONTENT 18 FP/AP package returned to normal condition 19 Power failure returned to normal condition 30 DTI line returned to normal condition 31 DCH D-channel link connection returned to the normal condition 32 CCH link connection returned to normal condition 35 The number of lockout stations was less than the predetermined number 36 DLC card returned to normal condition FAULT KIND (1ST)CONTENT ALARM KIND 01 System Initialized MN ALARM 03 The number of stack entries was more than the caution level MN ALARM 04 MP-FP/AP communication failure MN ALARM 08 FP/AP package down MN ALARM 09 Power failure MN ALARM 18 FP/AP package returned to normal condition -- 19 Power failure returned to normal condition -- 20 DTI line failure MN ALARM 21 DCH D-channel link connection failure MN ALARM 22 CCH link connection failure MN ALARM 25 The number of lockout stations was more than the predetermind number (Refer to CM42, 1ST data = 01) MN ALARM (Fixed) 26 DLC card down -- 30 DTI line returned to normal condition -- 31 DCH D-channel link connection returned to the normal condition -- 32 CCH link connection returned to normal condition -- 35 The number of lockout stations was less than the predetermined number -- 36 DLC card returned to normal condition --
ND-45669 (E) CHAPTER 3 Pag e 3 57 Revision 2.0 CMEA COMMAND CODE TITLE: FAULT INFORMATION STORE/DISPLAY FUNCTIONS EA MAT EXPLANATION OF SCREEN INFORMATION (Continued) 3: CPU Kind and FP/AP number for which a fault was detected 4: Date and Time of Fault Occurrence and Restoration 5-12: Fault-Related Information/Fault Restoration-Related Information INDICATION MEANING MP 00 MP FP 00 - 03 FP Number 0 - 3 AP 04 - 15 AP Card Number 4 - 15 FAU LT KIND NUMBER56789101112 01 Initial Kind, etc 1 , 2System Initialization-related information 3 03 Stack Kind 4 04 Communi- cation Fail- ure Kind 5 08 FP/AP Number 6 09 Power Fail- ure Kind 1 7Power Fail- ure Kind 2 7Power Fail- ure Kind 3 7 20 Fault Detail Kind 9 21 D-channel circuit No. 10 22 CCH No. 11 25 26 DLC Fail- ure KindLEN Station Number 1413 12