Home > NEC > Communications System > NEC Neax2000 Ivs Command Manual

NEC Neax2000 Ivs Command Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax2000 Ivs Command Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 473
    							CHAPTER 3 ND-45669 (E)
    Page 348 Addendum-002
    Revision 2.2 JANUARY, 1999
    CME5
    COMMAND CODE
    TITLE:
    STATION, TRUNK LINE MAKE BUSY
    E5
    4. DATA TABLE:
    Note 1:For a station that is made busy, call termination to the station is restricted, but Call origination is available.
    For extension lines on a Multiline Terminal, My Line and Multiline make busy can be set individually, with
    the same condition as mentioned above.
    Note 2:For a trunk that is made busy, the outgoing call is restricted, but on incoming, the call is available.
    Note 3:For the B channel that is made busy, call termination to the ISDN Terminal corresponds with the B channel
    is restricted, but call origination is available.
    Note 4:Under a made busy condition, the Busy Lamp on the card flashes (60 IPM).
    Note 5:Make idle of ZT since the ZT is in make busy forcibly when assigning the ZT data by CM10.
    1. FUNCTION:
    This command is used to make busy any station or trunk in the software.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    YSTATION TRUNK NUMBER SETTING DATA
    REMARKS
    No. MEANING DATA MEANING
    0X
    XXXXStation number
    (1-4 digits)
    Note 10
    1Make Busy set
    In serviceFor LC, AUC, and 
    DLC card
    1 000
    255Trunk number
    Note 20
    1Make Busy set
    In serviceFor COT, LDT, 
    ODT, 2BRT, and 
    AUC card
    2 XXXX
    X
    ISDN Circuit Station No.
    0: B1 Channel
    1: B2 Channel
    Note 30
    1Make busy set
    In serviceFor ILC card
    3 000
    255ZT number 0
    1
    2Make busy (forced)
    Make idle
    Make busy
    (after calls finished)For ZT
    Note 5
    STDEDEEXE
    ++E5Y + + + +
    (0/1) D ATA
    NUMBER STATION/TRUNK
    ~ ~
    ~
    , 
    						
    							ND-45669 (E) CHAPTER 3
    Addendum-002 Page 349
    JANUARY, 1999 Revision 2.2
    CME6
    COMMAND CODE
    TITLE:
    CALL FORWARDING SET/RESET FROM MAT/CAT
    E6
    4. DATA TABLE:
    Note:To reset Call Forwarding, assign “CCC” to the second data.
    1. FUNCTION:
    This command sets/resets the Call Forwarding service to each station from a MAT/CAT.
    2. PRECAUTION:
    CME6 can be used for any station irrespective of its state.
    3. ASSIGNMENT PROCEDURE:
     + E6YY +   +  +   +   + 
    YY MEANING DESTINATION No.
    00 Call Forwarding-All Calls • Destination = Extension;
    X-XXXX: Station No. (1-4 digits)
    • Destination = Outside party;
    X-XX
    +,+YY...YY
    Called No. (Max. 26 digits)
    Separator Mark
    Outgoing Trunk/LCR Group Access Code (1-2 
    digits)
    • Destination = Attendant; E000 01 Call Forwarding-Busy Line
    02 Call Forwarding-No Answer
    03 Call Forwarding-Busy Line/
    No Answer
    04 Split Call Forwarding-All Calls 0: Target station for Split Call Forwarding (Block 0)/ATT
    1: Target station for Split Call Forwarding (Block 1)
    2: Target station for Split Call Forwarding (Block 2)
    3: Target station for Split Call Forwarding (Block 3)
    4: Target station for Split Call Forwarding (Block 4)
    05 Split Call Forwarding-Busy Line/No 
    Answer5: Target station for Split Call Forwarding (Block 5)
    6: Target station for Split Call Forwarding (Block 6)
    7: Target station for Split Call Forwarding (Block 7)
    8: Target station for Call Forwarding
    9: Station Speed Dialing (Block 0)
    STDESTATION No.
    (1-4 digits)DEDESTINATION No.
    (1-26 digits)CCC
    (for reset)EXE
    [CME6] Call Forwarding Set/Reset From MAT/CAT 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 50
    Revision 2.0
    CME7
    COMMAND CODE
    TITLE:
    PASSWORD LEVEL
    E7
    4. DATA TABLE:
    Note:In case of YY = 20, 21, the data to be set is “1” only.
    1. FUNCTION:
    This command specifies the accessible commands for each Password Level.
    2. PRECAUTION:
    None
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    YY
    COMMAND CODE SETTING DATA
    No. PASSWORD LEVEL
    00
    01
    02
    03
    04
    05
    06
    10
    11
    12
    13
    14
    15
    16Password Level 0 – 6
    1 – 6
    2 – 6
    3 – 6
    4 – 6
    5 – 6
    6
    0
    1
    2
    3
    4
    5
    6XX: 00 – FF
    (Exclusive of 03, E7, E9)0: Allowed
    1:
      Restricted
    20 To clear all the Password Level 
    settings for individual commandsXX: 00 – FF
    (Exclusive of 03, E7, E9)1: All Password Levels exclud-
    ing Level 7 are restricted from 
    assignment of designated 
    command.
    21 To clear all the Password Level 
    settings for all commandsXX: 00 1: All Password Levels exclud-
    ing Level 7 are restricted 
    from assignment of all com-
    mands.
    ST  +  E7YY  +  DE  +COMMAND CODE
    (2 digits)+  DE   +D ATA
    (1 digit)+  EXE
    [CME7] Password Level 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 51
    Revision 2.0
    CME9
    COMMAND CODE
    TITLE:
    PASSWORD CODE
    E9
    MAT
    4. DATA TABLE:
    Note:Password Level 7 can access all the commands.
    1. FUNCTION:
    This command is used to define the Password Code of each Password Level and the availability of Pass-
    word Service.
    2. PRECAUTION:
    (1) Before setting the Password code, Function Number 8 (Change of Password) must be set to 0
    (Allowed).
    (2) When programming a Password Code, the Password Code for Password Level 7 must be made. If
    no Password Code of Password Level 7 is set, the programming of Password Service provision
    (CME9, FUNCTION No. 9) is restricted with the message “CODE NOT USED”. 
    Note
    (3) Function No. 9 (Password Service) must be set to 0 (Provided) after programming of all Password
    Codes is completed.
    3. ASSIGNMENT PROCEDURE:
    : Initial Data
    PASSWORD LEVEL No. /
    FUNCTION No.SETTING DATA
    REMARKS
    DATA MEANING
    0
    7Password Level 0
    Password Level 7X
    XX
    X . . . X
    (Max. 8 digits)Password Code Following Password Codes are 
    not available:
    “CC . . . C” (All “C”)
    “FF . . . F” (All “F”)
    8 Change of Password
    (Display of Password)0 
    1
     
    Allowed
    Restricted
    9Password Service 0
    1
     
    Provided
    Not provided
    ST  +  E9  +  DE  +PASSWORD LEVEL NO.
    /FUNCTION NO.
    (1 digit)+  DE  +  DATA  +  EXE
    ~~
    ~
    [CME9] Password Code 
    						
    							CHAPTER 3  ND-45669  (E)
    C M EA
    M AT
    1.  FUN CTIO N:
    ST  +   E AY   +   DE  +
    [ C M EA ]  Fau lt  I nf orm ation  Store /D isp lay F unct io n s 
    						
    							ND-45669  (E)   CHAPTER 3
    CM EA
    MAT
    : I n it ial Data
    ~ 
    						
    							CHAPTER 3  ND-45669  (E)
    C M EA
    M AT
    2  Regis tr atio n  of  fau lt 
    ~ 
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 55
    Revision 2.0
    CMEA
    COMMAND CODE
    TITLE:
    FAULT INFORMATION STORE/DISPLAY FUNCTIONS
    EA
    MAT
    n  
    Fault Information Display
    After the following operation:
                  
    The first screen displays on the MAT/CAT. The fault information is separated into four separate parts,
    and displayed on four screens. An example of fault information display is provided below:
    EXPLANATION OF SCREEN INFORMATION
    1: Fault Occurrence Kind No./Fault Restoration Kind No.
    FAULT KIND 
    NUMBERFAULT CONTENT
    01 System initialized
    03 The number of stack entries was more than the caution level 
    04 MP-FP/AP communication failure 
    08 FP-AP card down
    09 Power failure 
    20 DTI line failure 
    21 DCH D-channel link connection failure 
    22 CCH link connection
    25 The number of lockout stations was more than the predetermined number 
    26 DLC card down
    STDEDE
    EA0 00 ++++
    1st Screen2nd Screen
    4th Screen3rd Screen
    DE
    DEDE 1 : 03 MN MP    00
    12 3
    91011124
    5678 3 : xx xx xx xx 2 : 93/3/20 20 : 31
    3 : xx xx xx xx
    to 1st screen of next data 
    						
    							CHAPTER 3 ND-45669 (E)
    Pag e 3 56
    Revision 2.0
    CMEA
    COMMAND CODE
    TITLE:
    FAULT INFORMATION STORE/DISPLAY FUNCTIONS
    EA
    MAT
    EXPLANATION OF SCREEN INFORMATION (Continued)
    2: External Alarm Kind (MJ/MN/-)
    Use of External Alarm Kind - Minor (MN), Major (MJ) or external alarm is not provided (-) can be
    programmed by CMEA Y=2. The following table shows the standard data set by the 2nd data = 3 of
    CMEA Y=2.
    FAULT RESTORATION 
    KIND NUMBERFAULT RESTORATION CONTENT
    18 FP/AP package returned to normal condition
    19 Power failure returned to normal condition
    30 DTI line returned to normal condition
    31 DCH D-channel link connection returned to the normal condition
    32 CCH link connection returned to normal condition
    35 The number of lockout stations was less than the predetermined number
    36 DLC card returned to normal condition
    FAULT KIND 
    (1ST)CONTENT ALARM KIND
    01 System Initialized MN ALARM
    03 The number of stack entries was more than the caution level MN ALARM
    04 MP-FP/AP communication failure  MN ALARM
    08 FP/AP package down MN ALARM
    09 Power failure MN ALARM
    18 FP/AP package returned to normal condition  -- 
    19 Power failure returned to normal condition  -- 
    20 DTI line failure  MN ALARM
    21 DCH D-channel link connection failure  MN ALARM
    22 CCH link connection failure MN ALARM
    25 The number of lockout stations was more than the predetermind number 
    (Refer to CM42, 1ST data = 01) MN ALARM 
    (Fixed)
    26 DLC card down -- 
    30 DTI line returned to normal condition  -- 
    31 DCH D-channel link connection returned to the normal condition  -- 
    32 CCH link connection returned to normal condition  -- 
    35 The number of lockout stations was less than the predetermined number  -- 
    36 DLC card returned to normal condition  --  
    						
    							ND-45669 (E) CHAPTER 3
    Pag e 3 57
    Revision 2.0
    CMEA
    COMMAND CODE
    TITLE:
    FAULT INFORMATION STORE/DISPLAY FUNCTIONS
    EA
    MAT
    EXPLANATION OF SCREEN INFORMATION (Continued)
    3: 
    CPU Kind and FP/AP number for which a fault was detected
    4:  Date and Time of Fault Occurrence and Restoration
    5-12: Fault-Related Information/Fault Restoration-Related Information
    INDICATION MEANING
    MP 00 MP
    FP 00 - 03 FP Number 0 - 3
    AP 04 - 15 AP Card Number 4 - 15
    FAU LT  
    KIND 
    NUMBER56789101112
    01 Initial 
    Kind, etc 
    1 ,  2System Initialization-related information
    3
    03 Stack Kind 
    4
    04 Communi-
    cation Fail-
    ure Kind
    5
    08 FP/AP 
    Number 6
    09 Power Fail-
    ure Kind 1
    7Power Fail-
    ure Kind 2
     7Power Fail-
    ure Kind 3
    7
    20 Fault Detail 
    Kind 9
    21 D-channel 
    circuit No. 
    10
    22 CCH No. 
    11
    25
    26 DLC Fail-
    ure KindLEN Station Number 
    1413
    12 
    						
    All NEC manuals Comments (0)