Mitel Sx 50 Dpabx Instructions Guide
Have a look at the manual Mitel Sx 50 Dpabx Instructions Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Customer Data Entrv Forms COMMANDS 12) - 129 - Register 8 I l- 11 d c l- d I el COS 1 - COS 9 PROGRAMMING Extension Camp-on 0 = Disable, 1 = Enable -Trunk Camp-on 0 = Disable, 1 = Enable - Inward Dial Trunk Camp-on 0 = Disable, 1 = Enable r DID Restriction 0 = Disable, I = Enable cos 1 cos 2 cos 3 cos 4 cos 5 COS 6 cos 7 COS 8 cos 9 . 102 2-28 Revision 0 9104-091-l 02-NA Issue 3
Customer Data Entry Forms - COMMANDS 151 - 156 TRUNK GROUP PROGRAMMING - Register 1 l- - Trunk Select ( 0 = Automatic) - Type of Hunting I I I I I cld ef ah i 0 = Circular - 1 = Terminal - Trunk Group Overflow 0 = Disable 1 - 6 = Trunk Group Number Identified Trunk Group 0 = Disable, 1 = Enable r Trunk Group Access Code I ‘56 IAl I I I I I I I I DEFAULT VALUES GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 abcdefg I I ’ 1 1 f 1 1 1 8 9 9104-091-l 02-NA Issue 3 Revision 0 102 2-29
Customer Data Entrv Forms COMMANDS 151-- 156 TRUNK GROUP PROGRAMMING r -Register 2 - Wait for Dial Tone 0 = No wait, outpulse after delay 1 = Wait up to 5 seconds, then outpulse anyway 2 = Check for dial tone every 5 seconds 3 = Unlimited wait with detection by user - Dial Tone Detection Timing 0 = 120 ms required 1 = 40 ms required - Delay before Outpulsing (Wait for Dial Tone = 0) 1 - 5 seconds - Answer Supervision 0 = No Answer Supervision 1 = Supervision is Meter Pulse or Reversal 2 = Ignore Supervision except for Toll Restriction 3 = Supervision is Meter Pulse, Ignore Reversals - Restrict External Calls on REversal (0 = Disable, 1 = Enable) - DTMF or Rotary Outpulsing 0 = DTMF 1 = Rotary 2 = Rotary, Disable Outgoing Audio Until Answer 3 = Rotary, Inhibit DTMF Until Answer Simulate CO Dial Tone 0 = Disable, 1 = Enable Trunk Group SMDR l&able 0 = Disable, 1 = Enable r Trunk Group Last Number Redial 0 = Disable, 1 = Enable r Trunk Group Manual E&M Trunk l- L l- I Command1 a 1 b 1 c 1 d I 1 t efghi jk 151 2 I I I I I 0 = Disable, 1 = Enable t $ 0 0 T 102 230 Revision 0 GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 9104-091-l 02-NA Issue 3
- Customer Data Entry Forms COMMANDS 151 - 156 TRUNK GROUP PROGRAMMING - Register 3 Message Registration 0 = Disable 1 = Enable Message Registration 0 = Disable 1 = Enable Count Additional Message Units 0 = Disable 1 = Enable 2 = Enable, Insert Pseudo Message Unit every 6 seconds 3 = Enable, insert Pseudo Message Unit every 60 seconds Count Additional Message Units 0 = Disable 1 = Enable 2 = Enable, Insert Pseudo Message Unit every 6 seconds 3 = Enable, insert Pseudo Message Unit every 60 seconds r Initial Message Unit Charge Initial Message Unit Charge 0 - 99 Units 0 - 99 Units r Additional Message Unit Charge Additional Message Unit Charge 0 - 0 - 99 Units 99 Units Pseudo Answer Timer Pseudo Answer Timer (1 - 7) x 10 seconds GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 Default 3 0 0 0 0 0 1 3 9104-091-l 02-NA Issue 3 Revision 0 102 2-31
Customer Data Entrv Forms COMMANDS 151 + 156 TRUNK GROUP PROGRAMMING r Register 4 Sending Answer on Incoming Dial Trunks 0 = Send Answer when Answer Received (Supervision is Answer only) 1 = Send Answer after End of Dialing (Timeout) 2 = Send Answer upon Accessing Outgoing Trunk . Behind’PABX Operation 0 = Disable 1 = Enable, Flash is Loop Disconnect 2 = Enable, Flash is Ring Ground Behind PBX Recall Signal Duration 0 = 500 ms 1 = 750 ms Credit Card Calling Operation 0 = Disable, 1 = Enable GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 102 2-32 Revision 0 9104-091-l 02-NA Issue 3
Customer Data Entry Forms COMMAND 180 USER PROGRAMMING ACCESS - Register 1 - Command 100 - System Options 0 = Disable, 1 = Enable - Commands 121 - 129 COS Programming - 0 = Disable, 1 = Enable - Command 110 Feature Access Codes - 0 = Disable, 1 = Enable - Commands 301 - 310 - Station Programming 0 = Disable 1 = Enable all fields Commands 321 - 330 - Block Programming - Station Numbering Commands 331 * 350 - Block Programming - Station Memberships - Register 2 DEFAULT VALUES - Commands 361 - 366 - Station Hunting - Command 381 - Ring Group Programming Commands 700 + 752 - ARS Data Table Programming Commands 700 + 752 - ARS Data Table Programming 0 = Disable, 1 = Enable 0 = Disable, 1 = Enable Command 600 -Verified Authorization Command 600 -Verified Authorization 0 = Disable, 1 = Enable 0 = Disable, 1 = Enable DEFAULT VALUES DEFAULT VALUES - Commands 401 - 480 - SUPERSET Telephone Programming Commands 501 - 580 -Trunk Programming ‘I Commands 151 - 156 - Trunk Group Programming 0 = Disable 1 = Enable all fields 0 = Disable 1 = Enable 0 = Disable 1 = Enable 9104-091-I 02-NA Issue 3 Revision 0 102 2-33
Customer Data Entrv Forms COMMAND 180 - USER PROGRAMMING ACCESS - Register 3 - Command 185 - Function Key Programming 0 = Disable, 1 = Enable - Command 190 - System Security Programming abcdef 3 3’0 0 0 0 0 0 = Disable, 1 = Enable - Command 191 - User Security Code Programming 0 = Disable, 1 = Enable - Command 193 - DISA Access Code Programming 0 = Disable, 1 = Enable Note: Fields c and fare always disabled and r Command 192 - RMATS Security Code Programming DEFAULT cannot be modified. VALUES 102 2-34 Revision 0 9104-091-l 02-NA Issue 3
Customer Data Entry Forms r TelephoneNumber abc def 0 3 mm 0 6 23 9 DD0031FO Figure 2-2 Programmable Function Keys 9104-091-l 02-NA Issue 3 Revision 0 102 235
Customer Data Entrv Forms COMI\?AND 190 SYSTEM SECURITY CODE PROGRAMMING -Register 1 - System Security Code 1st Digit - r System Security Code 2nd Digit r System Security Code 3rd Digit v System Security Code 4th Digit a b c d e 1 1 7 7 7 2 I I I I COMMAND 191 -Register 1 DEFAULT VALUES (0 - 9) _ USER SECURITY CODE PROGRAMMING DEFAULT VALUE.S - User Security Code 1 st Digit User Security Code 2nd Digit User Security Code 3rd Digit User Security Code 4th Digit 9104-091-l 02-NA Issue 3 Revision 0 (0 - 9) ._ 102 2-37