    							Customer Data Entrv Forms 
    COMMANDS 12) - 129 
    - Register 8 
    I l- 11 d 
    c l- d I el 
    COS 1 - COS 9 PROGRAMMING 
    Extension Camp-on 
    0 = Disable, 1 = Enable 
    -Trunk Camp-on 
    0 = Disable, 1 = Enable 
    - Inward Dial Trunk Camp-on 
    0 = Disable, 1 = Enable 
    r DID Restriction 
    0 = Disable, I = Enable 
    cos 1 
    cos 2 
    cos 3 
    cos 4 
    cos 5 
    COS 6 
    cos 7 
    COS 8 
    cos 9 
    . 
    102 2-28 
    Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    - COMMANDS 151 - 156 TRUNK GROUP PROGRAMMING 
    - Register 1 
    l- - Trunk Select ( 0 = Automatic) 
    - Type of Hunting 
    I I I I I 
    cld ef ah i  0 = Circular - 
    1 = Terminal 
    - Trunk Group Overflow 
    0 = Disable 
    1 - 6 = Trunk Group Number 
    Identified Trunk Group 
    0 = Disable, 1 = Enable 
    r 
    Trunk Group Access Code 
    I ‘56 IAl I I I I I I I I 
    DEFAULT VALUES 
    GROUP 1 
    GROUP 2 
    GROUP 3 
    GROUP 4 
    GROUP 5 
    GROUP 6 abcdefg 
    I 
    I ’ 
    1 
    1 
    f 1 
    1 
    1 8 
    9 
    9104-091-l 02-NA Issue 3 
    Revision 0 102 2-29  
    						
    							Customer Data Entrv Forms 
    COMMANDS 151-- 156 TRUNK GROUP PROGRAMMING 
    r -Register 2 
    - 
    Wait for Dial Tone 
    0 = No wait, outpulse after delay 
    1 = Wait up to 5 seconds, then outpulse anyway 
    2 = Check for dial tone every 5 seconds 
    3 = Unlimited wait with detection by user 
    - Dial Tone Detection Timing 
    0 = 120 ms required 
    1 = 40 ms required 
    - Delay before Outpulsing (Wait for Dial Tone = 0) 
    1 - 5 seconds 
    - Answer Supervision 
    0 = No Answer Supervision 
    1 = Supervision is Meter Pulse or Reversal 
    2 = Ignore Supervision except for Toll Restriction 
    3 = Supervision is Meter Pulse, Ignore Reversals 
    - Restrict External Calls on REversal 
    (0 = Disable, 1 = Enable) 
    - DTMF or Rotary Outpulsing 
    0 = DTMF 
    1 = Rotary 
    2 = Rotary, Disable Outgoing Audio Until Answer 
    3 = Rotary, Inhibit DTMF Until Answer 
    Simulate CO Dial Tone 
    0 = Disable, 1 = Enable 
    Trunk 
    Group SMDR l&able 
    0 = Disable, 1 = Enable 
    r 
    Trunk Group Last Number Redial 
    0 = Disable, 1 = Enable 
    r Trunk Group Manual E&M Trunk 
    l- L 
    l- 
    I Command1 a 1 b 1 c 1 d 
    I 1 t efghi jk 
    151 2 I I I I I 
    0 = Disable, 1 = Enable 
    t 
    $ 0 0 T 
    102 230 Revision 0 GROUP 1 
    GROUP 2 
    GROUP 3 
    GROUP 4 
    GROUP 5 
    GROUP 6 
    9104-091-l 02-NA Issue 3  
    						
    							- 
    Customer Data Entry Forms 
    COMMANDS 151 - 156 
    TRUNK GROUP PROGRAMMING 
    - Register 3 
    Message Registration 
    0 = Disable 1 = Enable  Message Registration 
    0 = Disable 1 = Enable 
    Count Additional Message Units 
    0 = Disable 
    1 = Enable 
    2 = Enable, Insert Pseudo Message Unit every 6 seconds 
    3 = Enable, insert Pseudo Message Unit every 60 seconds  Count Additional Message Units 
    0 = Disable 
    1 = Enable 
    2 = Enable, Insert Pseudo Message Unit every 6 seconds 
    3 = Enable, insert Pseudo Message Unit every 60 seconds 
    r 
    Initial Message Unit Charge  Initial Message Unit Charge 
    0 - 99 Units  0 - 99 Units 
    r 
    Additional Message Unit Charge  Additional Message Unit Charge 
    0 -  0 - 99 Units  99 Units 
    Pseudo Answer Timer  Pseudo Answer Timer 
    (1 - 7) x 10 seconds 
    GROUP 1 
    GROUP 2 
    GROUP 3 
    GROUP 4 
    GROUP 5 
    GROUP 6 
    Default 
    3 0 0 0 0 0 1 3 
    9104-091-l 02-NA Issue 3 
    Revision 0 
    102 2-31  
    						
    							Customer Data Entrv Forms 
    COMMANDS 151 + 156 TRUNK GROUP PROGRAMMING 
    r 
    Register 4 
    Sending Answer on Incoming Dial Trunks 
    0 = Send Answer when Answer Received (Supervision is Answer only) 
    1 = Send Answer after End of Dialing (Timeout) 
    2 = Send Answer upon Accessing Outgoing Trunk . 
    Behind’PABX Operation 
    0 = Disable 
    1 = Enable, Flash is Loop Disconnect 
    2 = Enable, Flash is Ring Ground 
    Behind PBX Recall Signal Duration 
    0 = 500 ms 
    1 = 750 ms 
    Credit Card Calling Operation 
    0 = Disable, 1 = Enable 
    GROUP 1 
    GROUP 2 
    GROUP 3 
    GROUP 4 
    GROUP 5 
    GROUP 6 
    102 2-32 
    Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMAND 180 USER PROGRAMMING ACCESS 
    - Register 1 
    - Command 100 - System Options 
    0 = Disable, 1 = Enable 
    - Commands 121 - 129 COS Programming  - 
    0 = Disable, 1 = Enable 
    - Command 110 Feature Access Codes  - 
    0 = Disable, 1 = Enable 
    - Commands 301 - 310 - Station Programming 
    0 = Disable 
    1 = Enable all fields 
    Commands 321 - 330 - Block Programming - 
    Station Numbering 
    Commands 331 * 350 - Block Programming - 
    Station Memberships 
    - Register 2 
    DEFAULT VALUES 
    - Commands 361 - 366 - Station Hunting 
    - Command 381 - Ring Group Programming 
    Commands 700 + 752 - ARS Data Table Programming  Commands 700 + 752 - ARS Data Table Programming 
    0 = Disable, 1 = Enable  0 = Disable, 1 = Enable 
    Command 600 -Verified Authorization  Command 600 -Verified Authorization 
    0 = Disable, 1 = Enable  0 = Disable, 1 = Enable 
    DEFAULT VALUES  DEFAULT VALUES  - Commands 401 - 480 - SUPERSET Telephone Programming 
    Commands 501 - 580 -Trunk Programming 
    ‘I 
    Commands 151 - 156 - Trunk Group Programming 
    0 = Disable 
    1 = Enable all fields 0 = Disable 
    1 = Enable 
    0 = Disable 
    1 = Enable 
    9104-091-I 02-NA Issue 3 
    Revision 0 102 2-33  
    						
    							Customer Data Entrv Forms 
    COMMAND 180 - USER PROGRAMMING ACCESS 
    - Register 3 
    - Command 185 - Function Key Programming 
    0 = Disable, 1 = Enable 
    - Command 190 - System Security Programming 
    abcdef 
    3 
    3’0 0 0 0 0  0 = Disable, 1 = Enable 
    - Command 191 - User Security Code Programming 
    0 = Disable, 1 = Enable 
    - Command 193 - DISA Access Code Programming 
    0 = Disable, 1 = Enable 
    Note: Fields c and fare always disabled and 
    r 
    Command 192 - RMATS Security Code Programming 
    DEFAULT cannot be modified. 
    VALUES 
    102 2-34 Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    r 
    TelephoneNumber 
    abc def 
    0 
    3 
    mm 
    0 6 
    23 9 
    DD0031FO 
    Figure 2-2 Programmable Function Keys 
    9104-091-l 02-NA Issue 3 
    Revision 0 
    102 235  
    						
    							Customer Data Entrv Forms 
    COMI\?AND 190 SYSTEM SECURITY CODE PROGRAMMING 
    -Register 1 
    - System Security Code 1st Digit - 
    r System Security Code 2nd Digit 
    r 
    System Security Code 3rd Digit 
    v System Security Code 4th Digit 
    a b c d e 
    1 
    1 7 7 7 2  I 
    I I I 
    COMMAND 191 
    -Register 1 DEFAULT VALUES (0 - 9) 
    _ 
    USER SECURITY CODE PROGRAMMING 
    DEFAULT VALUE.S  - User Security Code 1 st Digit 
    User Security Code 2nd Digit 
    User Security Code 3rd Digit 
    User Security Code 4th Digit 
    9104-091-l 02-NA Issue 3 
    Revision 0 
    (0 - 9) 
    ._ 
    102 2-37  
    						