Home > Mitel > Communications System > Mitel Sx 50 Dpabx Instructions Guide

Mitel Sx 50 Dpabx Instructions Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Mitel Sx 50 Dpabx Instructions Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 727
    							PN 9104-091-001-NA 
    Issue 5, March 1993 
    sx-SOS 
    DIGITAL PRIVATE AUTOMATIC BRANCH EXCHANGE (DPABX) 
    I CONTRQL SHEET - PN 9104-091-106-NA 
    CONTENTS 
    Section Number 
    9104-091-001-NA 
    9104-091-010-NA 
    9104-091-l 00-NA 
    9104-091-l 02-NA 
    9104-091-l 05-NA 
    I 9104-091-l 50-NA 
    9104-091-l 80-NA 
    - 9104-091-200-NA 
    9104-091-210-NA 
    9104-091-220-NA 
    9104-091-221 -NA 
    9104-091-301-NA 
    9104-091350-NA Control Sheet 
    Documentation Index 
    General Description 
    Customer Data Entry Forms 
    Features Description 
    Ordering Information 
    Engineering Information 
    Shipping, Receiving and Installation 
    Customer Data Entry 
    ARS and Toll Control Description 
    Station Message Detail Recording (SMDR) 
    Remote Maintenance and Administration Test System 
    Troubleshooting Procedures & General Maintenance 
    Information Issue 
    5 
    5 
    5 
    3 
    5 
    3 
    5 
    5 
    5 
    5 
    5 
    5 
    5  
    						
    							Table of Contents 
    1. INTRODUCTION 
    General ............................. 
    Reason for Reissue 
    .................... 
    Section Overview ...................... .................... 
    100 l-l 
    . . . , .................... 
    100 l-l 
    .................... 100 l-l 
    PHYSICAL DESCRIPTION 
    General ............................................................... 
    100 2-l 
    CardFrame ............................................................ 
    100 2-l 
    Backplate..................................................;...:....: .. 
    100 2-5 
    Cover ................................................................. 
    100 2-6 
    PowerSupply ........................................................... 
    100 2-7 
    ControlCard ........................................................... 
    100 2-9 
    Control Card 2 (MCC2) 
    ................................................... 100 2-9 
    Peripheral Circuit Cards 
    ................................................... 100 2-l 2 
    ONSLineCard ......................................................... 
    100 2-16 
    OPSLineCard 
    ......................................................... 
    100 2-16 
    DNlCLineCard.. ....................................................... 
    100 2-17 
    COVLineCard ......................................................... 
    100 2-17 
    LS/GSTrunkCard ....................................................... 
    100 2-18 
    Direct Inward Dial (DID) Trunk Card 
    ......................................... 100 2-18 
    UniversalCard 
    -  .......................................................... 
    100 2-19 
    E&MTrunkModule ...................................................... 
    100 2-19 
    Music on Hold/Pager Module 
    ................................................ 100 2-22 
    RMATSModule ......................................................... 
    100 2-24 
    GenericModule.. ....................................................... 
    100 2-26 
    AttendantConsole ....................................................... 
    100 2-28 
    3. SYSTEM REQUIREMENTS 
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
    4. SYSTEM CONFIGURATION 
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
    Identifying the Software Revision Level . . . . . 
    Card Configurations . . . . . . . . . . . . . . . . . . . . 
    5. PERIPHERAL DEVICES 
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
    6. HARDWARE OVERVIEW 
    General .......................... 
    Microprocessor .................... 
    DX Switching Matrix ................ 
    Clock Signal Generation ............. 
    Digital Signal Processor .............. 
    Attendant Console interface .......... 
    Printer Interface .................... 
    DTMF Receivers ................... 
    Memory .......................... . . . . * . 
    . . . . . . 
    . . . . . . 
    . . . . . . 
    . . * . . . 
    . . * . . * . . 
    . . . . * . . . 
    . . . * . . . . 
    . . . . . . . , 
    . . . . . . . . 
    * . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 3-l 
    .................... 
    100 4-l 
    .................... 100 4-l 
    .................... 
    100 4-2 
    . . . . . . . . . . . . . . . . . . . . 
    100 5-l 
    ..,................... 
    ....... 
    ....... 
    ....... 
    ....... 
    ....... 
    ....... 
    ....... 
    ....... 
    .............. 
    .............. 
    .............. 
    .............. 
    .............. 
    .............. 
    .............. 
    .............. 
    100 6-l 
    100 6-l 
    100 6-l 
    100 6-3 
    100 6-3 
    100 6-3 
    100 6-3 
    100 6-3 
    100 6-3 
    7. SOFIWARE OVERVIEW 
    General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 7-l 
    9104-091-l 00-NA issue 5 Revision 0 . . . 
    III  
    						
    							General Descriotion 
    CallProcessingLayer .................................................... 100 7-1 
    Peripheral Processing Layer ............................................... 100 7-l 
    8. FEATURES 
    General ..,..........,........................................,,.....,. 100 8-1 
    9. MAINTENANCE 
    General ............................................................... 100 9-l 
    Alarms ................................................................ 100 9-l 
    TypesofDiagnostics ..................................................... 100 9-l 
    Diagnostic Test Routines .................................................. 100 9-l 
    List of Figures 
    Figure 2-l Overall View of the SX-508 System .............................. 100 2-2 
    Figure 2-2 Card Frame ................................................. 100 2-3 
    Figure 2-3 Card Frame Dimensions ....................................... 100 2-4 
    Figure 2-4 Backplate ................................................... 100 2-5 
    Figure2-5 Cover ...................................................... 100 2-6 
    Figure26 PowerSupply ................................................ 100 2-7 
    Figure 2-7 Power Supply Dimensions ...................................... 100 2-8 
    Figure 2-8 Control Card ................................................. 100 2-10 
    Figure 2-9 Control Card 2 (MCC2) ........................................ 100 2-11 
    Figure 2-l 0 Control Card Dimensions ....................................... 100 2-12 
    Figure 2-l 1 Peripheral Circuit Card .......................................... 100 2-13 
    Figure 2-l 2 Peripheral Card Dimensions ..................................... 100 2-l 5 
    Figure 2-13 E&M Trunk Module ............................................ 100 2-20 
    Figure 2-l 4 E&M Trunk Module Dimensions .................................. 100 2-21 
    Figure 2-l 5 Music On Hold/Pager Module ................................... 100 2-22 
    Figure 2-16 Music On Hold/Pager Module Dimensions .......................... 100 2-23 
    Figure 2-l 7 RMATS Module .............................................. 100 2-24 
    Figure 2-l 8 RMATS Module Dimensions .................................... 100 2-25 
    Figure 2-l 9 Generic Module .............................................. 100 2-26 
    Figure 2-20 Generic Module Dimensions .................................... 100 2-27 
    Figure 2-21 Attendant Console ............................................ 100 2-28 
    Figure 4-l Software Identification ......................................... 100 4-l 
    Figure 5-l SX-50 System Peripherals ...................................... 100 5-2 
    Figure 6-l SX-50 System Block Diagram ................................... 100 6-2 
    List of Tables 
    Table 2-l 
    CardandModuleTypes ........................................ 100 2-14 
    Table 3-l 
    Environmental Requirements .................................... 100 3-l 
    Table 3-2 Electrical Requirements ......................................... 100 3-l 
    Table 8-l Feature List 
    ............................ . .................... 100 8-l 
    iv Revision 0 9104-091-l 00-NA Issue 5  
    						
    							1 . 
    INTRODUCTION 
    General 
    1.1 This Section contains an overall description of the SX-508 Digital Private Automatic 
    Branch Exchange (DPABX). The SX-50 DPABX handles analog voice signals 
    (processed digitally) and is compatible with most Private Branch Exchange (PBX) 
    and Central Office (CO) equipment. 
    Reason for Reissue 
    I 
    1.2 Section 9104-091-l 00-NA, General Description, has been reissued to include a 
    description of the SUPERSET’” 410 and 
    SUPERSET 420 telephones, the Digital 
    Network Interface Circuit (DNIC) Line Card and the functionality provided by MS55 
    software. 
    Section Overview 
    1.3 This Section is divided into nine Parts as described below: 
    1. Introduction: this part. 
    2. Physical Description: describes the appearance, dimensions and circuit cards of 
    the SX-50 system. 
    3. System Requirements: lists the environmental and electrical requirements for 
    system operation. 
    4. System Configuration: lists the maximum line and trunk configurations for the 
    SX-50 system in tabular form. 
    5. Peripheral Devices: lists the interfacing capabilities of the SX-50 system. 
    6. Hardware Overview: describes the system hardware. . . 
    7. Software Overview: lists the software layers for system operation. 
    8. Features: provides a list of the SX-50 system features. . 
    9. Maintenance: lists the automatic maintenance routines. 
    9104-091-lO&NA Issue 5 
    Revision 0 100 l-l  
    						
    							General Description 
    i 
    100 l-2 Revision 0 9104-091-l 00-NA Issue 5  
    						
    							ml 
    2 
    . 
    PHYSICAL DESCRIPTION 
    General 
    2.1 The following items comprise the hardware of the SX-50 system: 
    l Cabinet Assembly: Card Frame, Backplate and Cover 
    l Power Supply, 
    l Control Card, 
    l Peripheral Circuit Cards, and 
    l Attendant Console. 
    Connections to the customer-provided cross-connect field are made via standard 
    25-pair cables (customer-provided). The cables enter from the bottom of the Cabinet 
    Assembly and attach to connectors on the front edge of the peripheral cards. The 
    weight of the SX-50 system (with a full quota of cards and no cables) is 21 kg (46 lb). 
    Refer to Figure 2-1, Overall View of the SX-50 System. 
    Card Frame 
    2.2 The Card Frame supports all the required.cards (the Control Card plus up to 10 
    peripheral cards) for system operation. The Card Frame is shown in Figure 2-2. The 
    Power Supply unit mounts on the left side of the Card Frame. The dimensions of the 
    Card Frame are shown in Figure 2-3; it weighs 3.25 kg (7.17 lb). 
    9104-091-lOO-NA Issue 5 
    Revision 0 100 2-l  
    						
    							General Description 
    BA( 
    PLATE 
    CONTROL 
    CARD . 
    CARD 
    FRAME 
    PERIPHERAL 
    CARD 
    DD0002 
    100 2-2 
    Figure 2-l Overall View of the SX-50 System ,’ 
    Revision 0 9104-091-l 00-NA issue 5  
    						
    							Physical Description 
    - 
    CARD FRAME LATCH 
    1 
    t 
    C 
    GAObNDlNG 
    BRAlD 
    Figure 2-2 Card Frame 
    9104-091-l 00-NA 
    Issue 5 
    Revision 0 
    100 23  
    						
    							General Description 
    A-- 
    26.3 cm 
    (10.4 Ill.) 
    t 
    39.7 cm 
    (15.6 in.) 
    llsl - 
    . 
    100 24 
    Figure 2-3 Card Frame Dimensions 36.3 cm 
    (14.3 in.) 
    DDoo21 
    Revision 0 9104-091-l 00-NA Issue 5  
    						
    							Physical Description 
    Bat kplate 
    2.3 The SX-50 system is wall-mounted using the Backplate provided. The Card Frame 
    hooks onto the upper and lower horizontal Card Frame Guides. The Card Frame 
    Latch secures it to the top of the Card Frame. The Control Card stiffening bar locks 
    with the guide on the Backplate and positions the Control Card for connection to the 
    Power Supply. It also provides support for the Control Card when inserting and 
    extracting the peripheral cards. The Backplate is also equipped with an Energy 
    Dumping Ground (EDG) bar and cable guides. The Backplate weighs 0.97 kg (2.14 
    lb). Refer to Figure 2-4, Backplate for the dimensions of the Backplate. 
    3cm 
    6 I” 
    I 36 
    (‘6 m 
    n.) * 42.4 cm 
    (16.7 in.) 
    l 
    - 
    Figure 2-4 Backplate 
    9104-091-l 00-NA Issue 5 
    Revision 0 100 2-5  
    						