Shipping, Receiving and Installation r . ‘i . . . ..- (6 AWG) 200 5-22 Figure 5-13(a) System Cabling Revision 0 9104-091-200-NA Issue 5
Installation Procedures Figure 5-13(b) System Cabling 9104-091-200-NA Issue 5 Revision 0 200 5-23
Shipping, Receiving and Installation . CARD HANDLE CABLE TIE DD0049 Figure 5-l 3(c) System Cabling 9-WIRE JACKS (CUSTOMER-PROVIDED) CABLE PROVIDED WITH CONTROL CARD ATENDANT CONSOLE MDFIPLANT WIRING S-WIRE CABLE (CUSTOMER-PROVIDED) 1, THE AlTENDANT CONSOLE CAN BE PLACED A MAXIMUM OF 200m FROM THE CONTROL CARD. 2. CONSOLE WIRING PAIRS (14.2-5, S-4) MUST BE KEPT AS PAIRS IN PLANT WIRING. DD0055 200 5-24 Figure 5-14 Remote Attendant Console Cable Installation Revision 0 9104-091-200-NA Issue 5
Installation Procedures Chart 5-6 Attendant Console Installation Step Action Comments 1. Install Cable at Attendant Console. Refer to Figure 5-l 5, Cable Installa- l Insert the Attendant Console Cable into the tion on the Attendant Console. socket. Note: the Attendant Console can be placed up to 200 m (218 yd.) from the SX-50 System. 2. Install the Handset. l Plug one end of the Handset Cord into the Handset. Plug the other end of the Handset Cord into one of the two sockets on the left- hand side of the Console. 3. If non-default Programmable Function Key Refer to Section 9104-091-210-NA, designations are to be used, Customer Data Entry (CDE). l Prepare the Attendant Console feature desig- nations for the Programmable Function Keys as required. l Remove Key Designation Cover: Gently bend cover to pull the upper and lower tabs out of their slots in the console housing. l Remove default Key Designation Card. l Complete and install the new Key Designation Card. l Replace Key Designation Cover: Gently bend cover to place both the upper and lower tabs in the slots in the console housing. ATENDANT CONSOLE AlTENDANT CONSOLE CABLE DD0038 Figure 5-15 Cable installation on the Attendant Console 9104-091-200-NA Issue 5 Revision 0 200 5-25
Shipping, Receiving and Installation - Chart 5-7 Miscellaneous Equipment installation Step Action Comments 1. Install the Customer-provided Night Bells Refer to Figure 5-16, Night Bell Con- Equipment. nections. l Connect the leads to the terminal block on the Control Card. l For ac Night Bells with a capacitor, terminate bell circuit between B and C. Connect termi- nals A and D together on the terminal block. l For ac Night Bells without a capacitor, termi- nate bell circuit between B and C. Add a 1.8 ^EF/250 V capacitor between terminals A and D on the terminal block. l For dc Night Bells with separate ringing supply, terminate one lead of the bell circuit to A. Con- nect ringing supply in series with bells. Termi- nate other lead of bell circuit to B. Terminals C and D are not used. 2. Install the Customer-provided Printer. Refer to Table 5-3, Printer Port Pin l Connect the printer cable to the RS-232-C Assignments. Extender Cable. l Connect the Extender Cable to the Printer Port on the Control Card. l Note that the printer can be located a maxi- -mum of 15 m away from the SX-50 system. 3. Install the Customer-provided Paging Equip- Refer to Figure 5-l 2, Universal Card ment. Module Installation. Refer to , Tip and l If an MOH/Pager Module is used, mount one Ring Assignments. Refer to Figure 5-l 7, Music/Paging Connec- module per system on the Universal Card; con- tions nect the leads to the proper terminal blocks on ’ the MDF. l If a Control Card 2 (MCC2) is used, connect MS53 I MS54 software or above must the paging equipment directly to the terminal be used. block on the Control Card. 4. Install the Customer-provided Music Source. Refer to Figure 5-17, Music/Paging l If an MOH/Pager Module is mounted on the Connections. Universal card, connect the music source ‘_ leads to the proper terminal blocks on the MDF. l If a Control Card 2 (MCC2) is used, connect the music source leads directly to the terminal block on the Control Card. 5. Install the Customer-provided W Voice Pro- cessingsystem. (Not Available for MS53). Refer to Section 9150-953-003-NA, VX Voice Installation and Repair Manual. 200 ‘5-26 Revision 0 9104-091-200-NA Issue 5
Installation Procedures TERMINAL BLOCK CROSS CONNECT CONTROL CARD FRAME AC NIGHT BELLS (WITH INTERNAL CAPACITOR) NIGH? BELL NIGHT BELL TERMINAL BLOCK CROSS CONNECT CONTROL CARD FRAME AC NIGHT BELLS (WITHOUT INTERNAL CAPACITOR) “p FRAME CROSS CONNECT TERMINA; BLOCK RELAYA [ ” REIAY B J.QURN C(NC’ NGING D(NC CONTROL CARD DC NIGHT BELLS DD0056 Figure 5-16 Night Bell Connections 9104-091-200-NA Issue 5 Revision 0 200 5-27
. Shipping, Receiving and Installation Table 5-3 Printer Port Pin Assignments Pin 1 Source Assignment Not Used I I 2 Printer 1 RxD (Receive Data) -3 SC-50 System TxD (Transmit Data) 4 Printer RTS (Request to Send) - 5 SX-50 System CTS (Clear to Send) I 6 I 1 Not Used 7 Common GND (Ground) 8* 25 Not Used Table 5-4 Control Card Status Switch Functions 1 Switch Number 1 Function I 1 OPEN - Programming: Security Code Required CLOSED - Programming: No Security Code Required I 2 OPEN - Test Line Disabled CLOSED - Test Line Enabled 3 NOT USED 4 OPEN - SMDR CLOSED - DEBUG (MITEL use only) 200 5-28 Revision 0 9104-091-200-NA Issue 5
Installation Procedures MDF MUSIC ON HOLD/PAGER MODULE ----- ----- NOTES: 1. PIN DESIGNATIONS SHOW MOH/PAGER MODULE IN FIRST POSITION OF UNIVERSAL CARD 2. THE SXS08 SYSTEM SUPPORTS ONE MOHlPAGER MODULE. I CONTROL CARD 2 I I I I. I I I I I I I TERMINAL BLOCK 4 I * 3 PAGER DDOO57 Figure 5-17 Music/Paging Connections 9104-091-200-NA Issue 5 Revision 0 200 5-29
Shipping, Receiving and Installation - Chart 5-8 System Power-Up and Load Default Data Step Action Comments 1. Ensure the Power Supply is OFF. 2. Plug in the ac Power Cord. 3. Set all the Control Card Status Switches to Refer to Table 5-4, Control Card Sta- open. tus Switch Functions. 4. Install Attendant Console. (If required). 5. Switch Power Supply ON. 6. Load Default Data.Within 10 seconds after ? ap- If this does not occur, refer to Section pears on the Control Card LED (the Attendant 9104-091-350-NA, Troubleshooting. Console displays LOAD DEFAULT DATA? If 0 does not appear on the Control l Toggle Status Switch 1 to the CLOSED posi- Card, LED, refer to Section tion and then back to OPEN. While the system 9104-091-350-NA, Troubleshooting. executes the power-up diagnostics, the Con- trol Card LED displays c, followed by d. The Attendant Console display shows NO COM- MUNICATION. The appearance of the A char- acter on the Control Card indicates the system has successfully loaded the default database. (The Attendant Console shows DEFAULT DATA LOADED). The flashing 0 on the Control Card LED indicates the system has completed the initialization process (the Attendant Con- sole displays the default date and time). 7. 8. Install the Cover. Refer to Figure 5-l 8, Cover Installa- l Place the top part of the Cover over the top tion. end of the Backplate. l Pull Cover down over Card Frame. l Position the cables in the slot at the bottom of the Cover. Lock the Cover. l The keys are located in one of the accessory bags. 200 530 Revision 0 9104-091-200-NA Issue 5
i- Installation Procedures moo37 Figure 5-18 Cover Installation 9104-091-200-NA Issue 5 Revision 0 200 5-31