    							Shipping, Receiving and Installation 
    r . 
    ‘i 
    . 
    . . ..- (6 AWG) 
    200 5-22 
    Figure 5-13(a) System Cabling 
    Revision 0 9104-091-200-NA Issue 5  
    						
    							Installation Procedures 
    Figure 5-13(b) System Cabling 
    9104-091-200-NA Issue 5 
    Revision 0 200 5-23  
    						
    							Shipping, Receiving and Installation 
    . 
    CARD 
    HANDLE 
    CABLE 
    TIE 
    DD0049 
    Figure 5-l 3(c) System Cabling 
    9-WIRE JACKS (CUSTOMER-PROVIDED) 
    CABLE PROVIDED WITH 
    CONTROL CARD 
    ATENDANT CONSOLE 
    MDFIPLANT WIRING 
    S-WIRE CABLE (CUSTOMER-PROVIDED) 
    1, THE AlTENDANT CONSOLE CAN BE PLACED A MAXIMUM OF 200m FROM THE CONTROL CARD. 
    2. CONSOLE WIRING PAIRS (14.2-5, S-4) MUST BE KEPT AS PAIRS IN PLANT WIRING. 
    DD0055 
    200 5-24 
    Figure 5-14 Remote Attendant Console Cable Installation 
    Revision 0 9104-091-200-NA Issue 5  
    						
    							Installation Procedures 
    Chart 5-6 Attendant Console Installation 
    Step Action Comments 
    1. Install Cable at Attendant Console. Refer to Figure 5-l 5, Cable Installa- 
    l Insert the Attendant Console Cable into the tion on the Attendant Console. 
    socket. 
    Note: the Attendant Console can be 
    placed up to 200 m (218 yd.) from the SX-50 
    System. 
    2. Install the Handset. 
    l Plug one end of the Handset Cord into the 
    Handset. Plug the other end of the Handset 
    Cord into one of the two sockets on the left- 
    hand side of the Console. 
    3. If non-default Programmable Function Key Refer to Section 9104-091-210-NA, 
    designations are to be used, Customer Data Entry (CDE). 
    l Prepare the Attendant Console feature desig- 
    nations for the Programmable Function Keys 
    as required. 
    l Remove Key Designation Cover: Gently bend 
    cover to pull the upper and lower tabs out of 
    their slots in the console housing. 
    l Remove default Key Designation Card. 
    l Complete and install the new Key Designation 
    Card. 
    l Replace Key Designation Cover: Gently bend 
    cover to place both the upper and lower tabs in 
    the slots in the console housing. 
    ATENDANT 
    CONSOLE 
    AlTENDANT 
    CONSOLE 
    CABLE 
    DD0038 
    Figure 5-15 Cable installation on the Attendant Console 
    9104-091-200-NA Issue 5 
    Revision 0 200 5-25  
    						
    							Shipping, Receiving and Installation 
    - Chart 5-7 Miscellaneous Equipment installation 
    Step Action Comments 
    1. Install the Customer-provided Night Bells Refer to Figure 5-16, Night Bell Con- 
    Equipment. nections. 
    l Connect the leads to the terminal block on the 
    Control Card. 
    l For ac Night Bells with a capacitor, terminate 
    bell circuit between B and C. Connect termi- 
    nals A and D together on the terminal block. 
    l For ac Night Bells without a capacitor, termi- 
    nate bell circuit between B and C. Add a 1.8 
    ^EF/250 V capacitor between terminals A and 
    D on the terminal block. 
    l For dc Night Bells with separate ringing supply, 
    terminate one lead of the bell circuit to A. Con- 
    nect ringing supply in series with bells. Termi- 
    nate other lead of bell circuit to B. Terminals C 
    and D are not used. 
    2. Install the Customer-provided Printer. Refer to Table 5-3, Printer Port Pin 
    l Connect the printer cable to the RS-232-C Assignments. 
    Extender Cable. 
    l Connect the Extender Cable to the Printer Port 
    on the Control Card. 
    l Note that the printer can be located a maxi- 
    -mum of 15 m away from the SX-50 system. 
    3. Install the Customer-provided Paging Equip- Refer to Figure 5-l 2, Universal Card 
    ment. Module Installation. Refer to , Tip and 
    l If an MOH/Pager Module is used, mount one Ring Assignments. Refer to 
    Figure 5-l 7, Music/Paging Connec- 
    module per system on the Universal Card; con- tions 
    nect the leads to the proper terminal blocks on ’ 
    the MDF. 
    l If a Control Card 2 (MCC2) is used, connect 
    MS53 I MS54 software or above must 
    the paging equipment directly to the terminal 
    be used. 
    block on the Control Card. 
    4. Install the Customer-provided Music Source. Refer to Figure 5-17, Music/Paging 
    l If an MOH/Pager Module is mounted on the Connections. 
    Universal card, connect the music source ‘_ 
    leads to the proper terminal blocks on the 
    MDF. 
    l If a Control Card 2 (MCC2) is used, connect 
    the music source leads directly to the terminal 
    block on the Control Card. 
    5. Install the Customer-provided W Voice Pro- 
    cessingsystem. 
    (Not Available for MS53). Refer to Section 9150-953-003-NA, 
    VX Voice Installation and Repair 
    Manual. 
    200 ‘5-26 Revision 0 9104-091-200-NA Issue 5  
    						
    							Installation Procedures 
    TERMINAL BLOCK 
    CROSS 
    CONNECT 
    CONTROL CARD 
    FRAME 
    AC NIGHT BELLS (WITH INTERNAL CAPACITOR) NIGH? 
    BELL 
    NIGHT 
    BELL 
    TERMINAL BLOCK 
     CROSS 
    CONNECT 
    CONTROL CARD 
    FRAME 
    AC NIGHT BELLS (WITHOUT INTERNAL CAPACITOR) 
     “p FRAME  CROSS 
    CONNECT 
    TERMINA; BLOCK 
     RELAYA [ ” 
    REIAY B 
    J.QURN C(NC’ 
    NGING D(NC 
    CONTROL CARD 
    DC NIGHT BELLS 
    DD0056 
    Figure 5-16 Night Bell Connections 
    9104-091-200-NA Issue 5 
    Revision 0 200 5-27  
    						
    							. 
    Shipping, Receiving and Installation 
    Table 5-3 Printer Port Pin Assignments 
    Pin 
    1 Source Assignment 
    Not Used 
    I I 2 Printer 1 RxD (Receive Data) 
    -3 SC-50 System TxD (Transmit Data) 
    4 Printer RTS (Request to Send) 
    - 
    5 SX-50 System CTS (Clear to Send) 
    I 6 I 1 Not Used 
    7 Common GND (Ground) 
    8* 25 Not Used 
    Table 5-4 Control Card Status Switch Functions 
    1 Switch Number 1 Function 
    I 1 
    OPEN - Programming: Security Code Required 
    CLOSED - Programming: No Security Code Required 
    I 
    2 
    OPEN - Test Line Disabled 
    CLOSED - Test Line Enabled 
    3 NOT USED 
    4 OPEN - SMDR 
    CLOSED - DEBUG (MITEL use only) 
    200 5-28 Revision 0 9104-091-200-NA Issue 5  
    						
    							Installation Procedures 
    MDF 
    MUSIC ON HOLD/PAGER MODULE 
    ----- 
    ----- 
    NOTES: 
    1. PIN DESIGNATIONS SHOW MOH/PAGER MODULE IN FIRST POSITION OF UNIVERSAL CARD 
    2. THE SXS08 SYSTEM SUPPORTS ONE MOHlPAGER MODULE. 
    I CONTROL CARD 2 
    I 
    I 
    I 
    I. 
    I 
    I 
    I 
    I 
    I 
    I 
    I 
    TERMINAL 
    BLOCK 4 
    I 
     
    * 
    3 PAGER 
    DDOO57 
    Figure 5-17 Music/Paging Connections 
    9104-091-200-NA Issue 5 
    Revision 0 200 5-29  
    						
    							Shipping, Receiving and Installation 
    - Chart 5-8 System Power-Up and Load Default Data 
    Step Action Comments 
    1. Ensure the Power Supply is OFF. 
    2. 
    Plug in the ac Power Cord. 
    3. Set all the Control Card Status Switches to 
    Refer to Table 5-4, Control Card Sta- 
    open. tus Switch Functions. 
    4. 
    Install Attendant Console. (If required). 
    5. 
    Switch Power Supply ON. 
    6. Load Default 
    Data.Within 10 seconds after ? ap- If this does not occur, refer to Section 
    pears on the Control Card LED (the Attendant 9104-091-350-NA, Troubleshooting. 
    Console displays 
    LOAD DEFAULT DATA? If 0 does not appear on the Control 
    l Toggle Status Switch 1 to the CLOSED posi- Card, LED, refer to Section 
    tion and then back to OPEN. While the system 9104-091-350-NA, Troubleshooting. 
    executes the power-up diagnostics, the Con- 
    trol Card LED displays c, followed by 
    d. The 
    Attendant Console display shows NO 
    COM- 
    MUNICATION. 
    The appearance of the A char- 
    acter on the Control Card indicates the system 
    has successfully loaded the default database. 
    (The Attendant Console shows 
    DEFAULT 
    DATA LOADED). 
    The flashing 0 on the Control 
    Card LED indicates the system has completed 
    the initialization process (the Attendant Con- 
    sole displays the default date and time). 
    7. 
    8. Install the Cover. Refer to Figure 5-l 8, Cover Installa- 
    l Place the top part of the Cover over the top tion. 
    end of the Backplate. 
    l Pull Cover down over Card Frame. 
    l Position the cables in the slot at the bottom of 
    the Cover. 
    Lock the Cover. 
    l The keys are located in one of the accessory 
    bags. 
    200 530 Revision 0 9104-091-200-NA Issue 5  
    						
    							i- Installation Procedures 
    moo37 
    Figure 5-18 Cover Installation 
    9104-091-200-NA Issue 5 
    Revision 0 
    200 5-31  
    						