    of 727
    							Customer Data Entry Forms 
    COMMAND IOO- SYSTEM OPTIONS PROGRAMMING 
    - Register 01 SYSTEM MAINTENANCE 
    r 
    Automatic Diaanostics 
    0 = Disable,- 1 = Enable 
    RMATS Protocol Selection 
    0 = CCllT, 1 = North American 
    r Test Line Equipment Number 
    001 + 160 
    r 
    Register 02 ATTENDANT FUNCTIONS 
    Executive Busy Override (Console) 
    0 = Disable 
    - 1 = Enable Except on I/C Trunks, 
    2 = Enable on all calls 
    Console Inhibit 
    - 0 = Disable 
    1 = Enable 
    102 2-6 Revision 0 9104-091-l 02-NA Issue 3 .:  
    						
    							Customer Data Entrv Forms 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    - Register 03 TONE AND RINGING CONTROL 
    -Tone Plan Variants (0 = North American, 1 = Hong Kong 
    2 = Taiwan) 
    - Transfer Dial Tone (0 = Disable, 1 = Enable) 
    - Ringing Cadence Cycle Time 
    3 = 3 seconds 
    4 = 4 seconds 
    5 = 5 seconds 
    abcdefghij 
    0 3 0 
    Default 
    0 1 4 1 1 2 0 0 
    L l- 
    Discriminating Ringing 
    - 0 = Disable, 1 = Enable 
    l- 
    Distinctive Callback Ringing 
    - 0 = Disable, 1 = Enable 
    -I- 
    Disconnect Tone 
    0 = Disable 
    - 1 = Send selected DTMF tone to Dictation Port 
    2 = Connect selected Call Progress Tone to 
    - Dictation Port 
    Tones Selected 
    - If field H is 1: 
    00 - 09 = DTMF digits 0 - 9 
    10 = DTMF * sign 
    11 = DTMF # sign 
    If field H is 2: 
    00 = Dial Tone 
    01 = Busy Tone 
    02 = Reorder Tone 
    - 
    I I 
    9104-091-l 02-NA Issue 3 
    Revision 0 102 2-9  
    						
    							Customer Data Entrv Forms 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    Register 04 field values should not be changed. 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    -Register 05 TRUNK CONNECTIONS 
    - CO to CO Connection 
    0 = Disable, 1 = Enable 
    - E&M to E&M Connection 
    0 = Disable, 1 = Enable 
    - CO to E&M Connection 
    0 = Disable 
    1 = Enable for Incoming CO Trunks Only 
    2 = Enable for Outgoing CO Trunks Only 
    3 = Enable for Borh Incoming and Outgoing CO Trunks 
    - Conference Warning Tone 
    0 = Disable 
    1 = Enable if a CO Trunk is a conferee 
    2 = Enable on all Conferences 
    - DID to CO Connection 
    0 = Disable, 1 = Enable 
    DID to E&M Connection 
    0 = Disable, 1 = Enable 
    DID to DID Connection 
    0 = Disable, 1 = Enable 
    102 2-10 Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    -Register 06 
    STATION AlTRIBUTES 
    r 
    Station Switchhook-Flash Timing 
    0=150-+750ms - 
    1 = 150 - 1500 ms 
    2 = Flash is Release 
    3 = 90 ms Calibrated Flash 
    - Station Digit Collection 
    1 = 1opps 
    2 = 20 pps 
    Partial Flash Inhibit 
    1 = Disable, 2 = Enable 
    RESERVED 
    r 
    Register 07 SUPERSET TELEPHONE ATTRIBUTES 
    -Auto-Answer 
    0 = Disable, 1 = Enable 
    -SUPERSET Auto-Hold 
    0 = Disable, 1 = Enable 
    I 7 Delayed Ringing Key Timeout 
    l-u 3  2 1 =  =  = 20  30  10 seconds  seconds  seconds 
    9104-091-l 02-NA Issue 3 
    Revision 0 
    102 2-11  
    						
    							Customer Data Entry Forms 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    - - Register 08 OVERFLOW CONTROL 
    - - Overflow Mode in Day Service 
    0 = Disable 
    1 = Immediate Switching to Overflow - 
    2 = Automatic Switching to Overflow after Time-out 
    3 = Automatic Switching to Night Service 
    - Overflow Mode in Night Service . 
    abcdefghi 
    0 8 
    Default 2 0 3 2 0 0 0  O = Disable 
    1 = immediate Switching to Overflow 
    2 = Automatic Switching to Overflow after Time-out 
    - Automatic Switch to Overflow Time-out 
    (1 + 7) x 10 seconds 
    Internal Calls to Console Routed to Overflow 
    0 = Disable 
    1 = Enable During Day Service 
    2 = Enable During Night Service 
    3 = Enable During Both Day and Night Service 
    r 
    - Overflow Point 
    000 = Night Bell 
    001 - 160 = Station (Equipment Number) 
    161 --, 166 = Hunt Group 
    167 = Ring Group 
    1 
    102 2-12 Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    - Register 09 FEATURES SELECTION 1 
    -Abbreviated Dial Enable 
    l- L l- 
    T- -I- -l- I 
    II 
    0 = Disable 1 = Enable 
    - Last Number Redial # Key Access 
    0 = Disable, 1 = Enable 
    -Conflict Dialing Timer . 
    I- 
    0 = Disable 
    1 = 3 seconds 
    2 = 5 seconds 
    3 = 7 seconds 
    - Music on Hold 
    0 = Disable, 1 = Enable 
    -Background Music 
    0 = Disable, 1 = Enable 
    - Abbreviated Dial Access 
    0 = 2 digit index number - 90 entries maximum 
    1 = 3 digit index number 
    - 900 entries maximum 
    r 
    RESERVED 
    - 
    9104-091-l 02-NA Issue 3 
    Revision 0 
    102 2-13  
    						
    							Customer Data Entrv Forms 
    COMMAND 100 _ SYSTEM OPTIONS PROGRAMMING 
    -Register 10 FEATURES SELECTION 2 
    - Automatic Wajeup 
    0 = Disable 
    1 = Enable with Wake-up Tone 
    2 = Enable with Music 
    3 = Enable with Intercept to RAD 
    -Automatic Wake-up Printout 
    0 = Disable 
    1 = Enable 
    -Message Register Audit 
    0 = Disable 
    1 = Enable 
    2 = Enable with Clearing of Message Registers 
    - Use of Hash (#) for Trunks 
    0 = Enable Tone-to-Pulse Override on Trunks 
    1 = Enable End-of-Dial 
    - Proportional Call Charging 
    0. = Charge to Originating Extension Only 
    1 = Charge to All Parties Involved in the Call 
    -RESERVED 
    r 
    Room Status Printout 
    0 = Disable 
    1 = Enable 
    102 2-14 Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    - Register 11 TIME-OUT SELECTION 
    - Timed Recall - Camp-on (Trunks) 
    (1 + 7) x 10 seconds 
    - Timed Recall - No Answer 
    (1 - 7) x 10 seconds - 
    - Timed Recall - Call Hold (Extension) 
    (1 -+ 4) x 1 minute 
    - Timed Recall - Call Hold (Attendant) 
    (1 - 7) x 10 seconds . 
    Call Forward No Answer Timeout 
    (1 -+ 7) x 10 seconds 
    Drop Unanswered Trunks after 5 minutes 
    0 = Disable, 1 = Enable 
    - 
    L 
    - Register 12 MESSAGE WAITING 
    - 
    I- - Message Waiting System Enable 
    abcdef 
    1 2 
    Default 2 1 3 1 
    -I- L 
    0 = Disable 
    1 = Enable with Lamps 
    2 = Enable with Bells 
    3 = Enable with 30-second Manual Line 
    - Message Waiting Indication 
    -r 
    0 = Always, 
    1 = During Day Service Only 
    - Message Waiting Indication Interval 
    1 = 5 minutes 
    2 = 10 minutes 
    3 = 15 minutes 
    4 = 20 minutes 
    l--L- 
    Message Waiting Automatic Cancel 
    0 = Disable, 1 = Enable 
    9104-091-l 02-NA Issue 3 
    Revision 0 102 2-15  
    						
    							Customer Data Entry Forms 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    - -Register 13 AUTOMATIC ROUTE SELECTION (ARS) 
    - ARS Enable 
    0 = Disable, 1 = Enable 
    - ARS Attendant Bypass 
    0 = Disable, 1 = Enable 
    - ARS Alarms 
    0 = Disable, 1 = Enable 
    - ARS Return Dial Tone 
    0 = Disable, 1 = Enable 
    - 
    I 
    I I I l- -L 1 T -L l- I 
    - Expensive Route Warning Tone 
    0 = Disable, 1 = Enable 
    - Attendant ARS Routing Class of Service 
    0 = ARS does not apply 
    1 = RCS 1 
    2=RCS2 
    3=RCS3 
    -ARS Interdigit Timeout 
    0 = 5 seconds 
    1 = 10 seconds 
    l- -L 
    -Abbreviated Dial ARS Bypass Enable 
    0 = Disable, 1 = Enable 
    abcdefghij 
    1 3 
    Default 0 
    0 000010 
    102 2-16 Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMAND 100 SYSTEM OPTIONS PROGRAMMING 
    1 Register 14 SYSTEM MESSAGE DETAIL RECORDING (SMDR) 
    - SMDR System Enable 
    0 = Disable 
    1 = Enable Incoming Trunks Calls Only 
    2 = Enable Outgoing Trunks Calls Only 
    3 = Enable Both Incoming and Outgoing Trunk Calls 
    - Record Meter Pulses 
    0 = Disable, 1 = Enable 
    - Local Call Indicator 
    0 = Disable, 1 = Enable 
    I Incoming Calls Record Only COs 
    0 = Disable, 1 = Enable 
    - Drop Calls of less than 8 digits 
    0 = Disable, 1 = Enable 
    - Drop Incomplete Outgoing Calls 
    0 = Disable, 1 = Enable 
    - Overwrite Queued Printer Buffer 
    0 = Disable, 1 = Enable 
    - SMDR X Digits Dialed 
    0 = Disable 
    1 - 7 = 1 - 7 Digits Dialed 
    VAC Overwrite Account Code 
    0 = Priority to VAC printing 
    1 = Priority to Account Code printing 
    I Register 15 ACCOUNT CODE CONTROL 
    r 
    Number,of Digits (maximum if Variable Length enabled) 
    0 = Disable Account Codes 
    1 - 8 = Digits 
    Variable Length Account Codes 
    0 = Disable, 1 = Enable 
    Verified Authorization Code Enable/Length 
    0 = Disable, 1 + 8 = 1 - 8 Digits 
    NOTE: All Verified Authorization Codes (VAC) 
    must be deleted prior to changing 
    VAC length. 
    9104-091-l 02-NA Issue 3 
    Revision 0 
    102 2-17  
    						