    of 727
    							Customer Data Entry Forms 
    COMMANDS 501 + 580 TRUNK PROGRAMMING 
    TYPE: 
    - Register 1 
    - Trunk Group Membership (1 - 6 = Trunk GroupNumber) (0 = Incoming Calls Only) 
    -Trunk Alarm Control (0 = Disable, 1 = Enable) 
    - Trunk Hardware Type 
    0 = Short Analog CO Trunk 4 = Satellite Tie Trunk 
    1 = Long Analog CO Trunk 5 = Short Analog DID Trunk 
    2 = Analog Toll Office Trunk 6 = Long Analog DIDTrunk ( 
    3 = Analog Tie Trunk 
    - Trunk Class of Service (1 - 9) 
    - Inward Dial Delay before Answer (8 set) 
    (0 = Disable, 1 = Enable 
    Note: this applies to all trunk types. 
    - Connect to Outgoing Trunk without Third Party 
    0 = Disable, 1 = Enable 
    Inward Dialing ARS 
    Routing Class of Service (1 - 3) 
    0 = ARS does not apply 
    r Trunk Use 
    0 = Disable 2 = Use as a Tie Trunk 
    1 =UseasaCO 3 = Used as a DID Trunk 
    Trunk Dialing Type 
    0 = DIL, 1 = DISA, 3 = DID 
    I 
    Default 1 0 1 6 1 0 1 
    0 3 2 CO TRUNK 
    E&M TRUNK 
    DID TRUNK 
    . . 
    : 
    102 2-60 
    Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMANDS 501 - 580 TRUNK PROGRAMMING 
    TYPE: 
    SLOT: 
    - Register 2 
    - Trunk Outpulsing Break/Make Ratio 
    0 = 60140 
    1 = 65135 
    2 = 30120 
    3 = 35115 
    - Disconnect Supervision Guaranteed? 
    0 = No, 1 = ?es 
    - Disappearance of Reversal 
    0 = is ignored 
    1 = means disconnect 
    - Reversal Meaning on Call Origination 
    0 = Not Incoming Call 
    1 = Incoming Call 
    - Disconnect Timing 
    0 = 60 ms 3 = 4.0 set 
    1 = 500 ms 4=10.Osec 
    2 = 1.5 set 5 = Disconnect Ignored 
    Start Type (CO Trunks) 
    0 = Loop Start 
    1 = Ground Start 
    r 
    Trunk Hang-up Delay (Guard) Timer 
    01 -+16=1 +16seconds 
    L 
    l- L 
    -I- l- 
    J I I---l l- 
    lCommandlalbjcldlejf lglhl i 
    5 2 
    - 
    5- 2 
    5- 2 
    5- 2 
    5 2 
    - 
    I 5-14 I I I I I I I I 
    5 
    2 
    - 
    5- 2 
    Default 200001001 
    9104-091-l 02-NA Issue 3 
    Revision 0 
    102 2-61  
    						
    							Customer Data Entry Forms 
    COMMANDS 561 - 580 TRUNK PROGRAMMING 
    TYPE: 
    - Register 3 
    Command a 
    bl “I  - Tie Line Disconnect Timer 
    0=150ms 
    1 = 300 ms 
    -E&M Lead Inversion 
    Type 1 Type 5 
    o= M-Lead None 
    l= ‘Both E-Lead 
    2= None M-Lead 
    3= E-Lead Both 
    l- 
    -E&M Delay Dial Outgoing 
    0 = Disable 
    1 = Enable 
    - E&M Wink Start Incoming 
    0 = Disable 
    1 = Enable 
    -r 7 
    - E&M Wink Start Outgoing 
    0 = Disable 
    1 = Enable 
    RESERVED 
    I I 
    dlelflgl 
    I Default 131112101010121 
    102 2-62 Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMANDS 501 - 580 
    TRUNK PROGRAMMING 
    - Register 4 
    TYPE: 
    - Dictation Trunk (for LS/GS Trunks) 
    0 = Disable 
    1 = Enable 
    - Inter-ringing Delay (for KS/GS Trunks) 
    5 
    - 4 
    5 
    - 4 
    Default 4 
    0 5 1001000* 3 - 9 seconds 
    -Day Answer Mode 
    Day Illegal Number Intercept (DID/DISA) 
    0 = Direct-In Line 
    1 = LDNl 2 = LDN2 
    3 = LDN3 
    - Day Answer Point (Day Answer Mode = 0) 
    Day Inward Dial Trunk Intercept Answer Point (DID/DISA) 
    000 = Night Bell 
    001 -+ 160= Station Number 
    161 + 166= 
    Hunt Group Number 
    167= 
    Ring Group 
    168= RMATS 
    - Busy Intercept 
    0 = Disable 
    1 = Enable 
    - Do Not Disturb Intercept 
    0 = Disable 
    1 = Enable 
    - No Answer Intercept 
    0 = Disable 
    1 = Enable 
    Illegal/Vacant Number Intercept 
    0 = Disable 
    1 = Enable 
    * = 0 for CO & DID Trunks; 1 for E&M Trunks 
    9104-091-l 
    02-NA Issue 3 
    Revision 0 102 2-63  
    						
    							Customer Data Entry Forms 
    COMMANDS 561 - 580 
    TRUNK PROGRAMMING 
    TYPE: 
    Night answer Mode 
    Night illegal Number Intercept (DID/DISA) 
    0 = Flexible Night Service 
    1 = LDN 1 
    2=LDN2 
    3=LDN 3 _ 
    5 
    Register 5 
    -Night Answer Point (Night Answer Mode = 0) 
    Night Inward Dial Trunk Intercept Answer Point (DID/DISA) 
    000 = Night Bell 
    001 - 160 = Station Number 
    161 - 166 = Hunt Group Number 
    167= Ring Group 
    168= RMATS 
    r 
    DID Night Answer Point 
    0 = Disable 
    1 1 = Enable 
    e f 
    I I 
    I I 
    102 2-64 
    Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMANDS 501 - 580 TRUNK PROGRAMMING 
    - Register 6 
    - DID Start Type 
    0 = Immediate Start 
    1 = Wink Stat-l 
    2 = Delay Dial 
    - 
    RESERVED 
    - Incoming Address Signalling 
    0 = LoopDial Pulsing 
    1 = Battery-and-Ground Pulsing 
    2 = DTMF 
    - N = Number of Digits Expected (1 - 9) 
    - M = Number of Digits to be Absorbed (0 - 8) 
    Digits to be Inserted 
    5 6 
    - 
    5- 6 
    Default 6 1 1 0 4 1 
    TYPE: 
    9104-091-l 02-NA Issue 3 Revision 0 l-02 2-65  
    						
    							Customer Data Entry Forms 
    COMMANDS 501 + 580 
    TRUNK PROGRAMMING 
    TYPE: 
    r 
    - Register 7 
    -r 
    - Incoming Seizure Debounce Timer 
    (01 - 15) x 10 ms 
    - WinkTimer 
    (3 + 6) x 50 ms 
    - Permanent-Signal Partial-Dial Timer 
    .(I +6)x5s 
    - DID Disconnect Timer 
    (3-6)x50ms 
    Release Acknowledge Timer 
    002+12os 
    l- 
    a 1 b 1 c 1 d I e I f I g 
    I h I i I 
    5 
    7 - 
    5 - 7 
    I Default I 7 I I I I I o I 4 I I I, I I I 
    102 2-66 
    Revision 0 
    9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entrv Forms 
    COMMAND 600 VERIFIED AUTHORIZATION CODE PROGRAMMING 
    L I l- l- 
    11 DEFAULT VALUES  - Register Number: 001 +.999 
    - VAC Activation: 0 = Disable, 1 = Enable 
    - CDS for Authorization Code 
    0 = Disable, 1 -j 9 = COS 1 - 9 (for VAC) 
    - ARS Routing Nilmber 
    1 +3=ARSRCSl -3(forVAC), 
    0 = Original RCS Number of Calling Device 
    Authorization Code (1 to 8 digits) 
    9104-091-102-NA Issue 3 
    Revision 0 102 2-67  
    						
    							Customer Data Entry Forms 
    COMMAND 700 ARS DIGIT COMPARISON TABLE PROGRAMMING 
    r 
    Entry Number 
    001 - 800 
    r 
    Time-of- Day Table Number 
    01 -45 
    [ 1 
    [ . . 
    1 
    1 I 
    1 1 
    102 2-68 Revision 0 9104-091-l 02-NA Issue 3  
    						
    							Customer Data Entry Forms 
    COMMA-NDS 701 - 745 
    ARS TIME-OF-DAY TABLE PROGRAMMING 
    COMMAND 7 CO-MMAND 7 
    - -. 
    I- 
    r 
    a 
    1 
    1 
    2 
    - Period Number 
    - Start Hour 
    00 - 23 
    - Start Minute 
    00 + 59 
    Route List 001 + 200, 
    000 = not programmed 
    RCS 1 Route List 
    RCS 2 Route List 
    RCS 3 Route List 
    Ill I I I I I 
    elf 1 al hl iI iI kl I Iml nl 
    - Period Number 
    - Start Hour 
    00 - 23 
    . 
    - Start Minute 
    00 - 59 
    Route List 001 + 200, 
    000 = not programmed 
    RCS 1 Route List 
    RCS 2 Route List 
    RCS 3 Route List 
    I 
    1 I I I I I 
    cldlelf I al hl i jI k llmln 
    I I I 
    - - ., _ - 0 0 0 0 0 0 0 0 0 Default - - - - 0 0 0 0 0 0 0 0 0 Default 