Customer Data Entry Forms COMMANDS 501 + 580 TRUNK PROGRAMMING TYPE: - Register 1 - Trunk Group Membership (1 - 6 = Trunk GroupNumber) (0 = Incoming Calls Only) -Trunk Alarm Control (0 = Disable, 1 = Enable) - Trunk Hardware Type 0 = Short Analog CO Trunk 4 = Satellite Tie Trunk 1 = Long Analog CO Trunk 5 = Short Analog DID Trunk 2 = Analog Toll Office Trunk 6 = Long Analog DIDTrunk ( 3 = Analog Tie Trunk - Trunk Class of Service (1 - 9) - Inward Dial Delay before Answer (8 set) (0 = Disable, 1 = Enable Note: this applies to all trunk types. - Connect to Outgoing Trunk without Third Party 0 = Disable, 1 = Enable Inward Dialing ARS Routing Class of Service (1 - 3) 0 = ARS does not apply r Trunk Use 0 = Disable 2 = Use as a Tie Trunk 1 =UseasaCO 3 = Used as a DID Trunk Trunk Dialing Type 0 = DIL, 1 = DISA, 3 = DID I Default 1 0 1 6 1 0 1 0 3 2 CO TRUNK E&M TRUNK DID TRUNK . . : 102 2-60 Revision 0 9104-091-l 02-NA Issue 3
Customer Data Entry Forms COMMANDS 501 - 580 TRUNK PROGRAMMING TYPE: SLOT: - Register 2 - Trunk Outpulsing Break/Make Ratio 0 = 60140 1 = 65135 2 = 30120 3 = 35115 - Disconnect Supervision Guaranteed? 0 = No, 1 = ?es - Disappearance of Reversal 0 = is ignored 1 = means disconnect - Reversal Meaning on Call Origination 0 = Not Incoming Call 1 = Incoming Call - Disconnect Timing 0 = 60 ms 3 = 4.0 set 1 = 500 ms 4=10.Osec 2 = 1.5 set 5 = Disconnect Ignored Start Type (CO Trunks) 0 = Loop Start 1 = Ground Start r Trunk Hang-up Delay (Guard) Timer 01 -+16=1 +16seconds L l- L -I- l- J I I---l l- lCommandlalbjcldlejf lglhl i 5 2 - 5- 2 5- 2 5- 2 5 2 - I 5-14 I I I I I I I I 5 2 - 5- 2 Default 200001001 9104-091-l 02-NA Issue 3 Revision 0 102 2-61
Customer Data Entry Forms COMMANDS 561 - 580 TRUNK PROGRAMMING TYPE: - Register 3 Command a bl “I - Tie Line Disconnect Timer 0=150ms 1 = 300 ms -E&M Lead Inversion Type 1 Type 5 o= M-Lead None l= ‘Both E-Lead 2= None M-Lead 3= E-Lead Both l- -E&M Delay Dial Outgoing 0 = Disable 1 = Enable - E&M Wink Start Incoming 0 = Disable 1 = Enable -r 7 - E&M Wink Start Outgoing 0 = Disable 1 = Enable RESERVED I I dlelflgl I Default 131112101010121 102 2-62 Revision 0 9104-091-l 02-NA Issue 3
Customer Data Entry Forms COMMANDS 501 - 580 TRUNK PROGRAMMING - Register 4 TYPE: - Dictation Trunk (for LS/GS Trunks) 0 = Disable 1 = Enable - Inter-ringing Delay (for KS/GS Trunks) 5 - 4 5 - 4 Default 4 0 5 1001000* 3 - 9 seconds -Day Answer Mode Day Illegal Number Intercept (DID/DISA) 0 = Direct-In Line 1 = LDNl 2 = LDN2 3 = LDN3 - Day Answer Point (Day Answer Mode = 0) Day Inward Dial Trunk Intercept Answer Point (DID/DISA) 000 = Night Bell 001 -+ 160= Station Number 161 + 166= Hunt Group Number 167= Ring Group 168= RMATS - Busy Intercept 0 = Disable 1 = Enable - Do Not Disturb Intercept 0 = Disable 1 = Enable - No Answer Intercept 0 = Disable 1 = Enable Illegal/Vacant Number Intercept 0 = Disable 1 = Enable * = 0 for CO & DID Trunks; 1 for E&M Trunks 9104-091-l 02-NA Issue 3 Revision 0 102 2-63
Customer Data Entry Forms COMMANDS 561 - 580 TRUNK PROGRAMMING TYPE: Night answer Mode Night illegal Number Intercept (DID/DISA) 0 = Flexible Night Service 1 = LDN 1 2=LDN2 3=LDN 3 _ 5 Register 5 -Night Answer Point (Night Answer Mode = 0) Night Inward Dial Trunk Intercept Answer Point (DID/DISA) 000 = Night Bell 001 - 160 = Station Number 161 - 166 = Hunt Group Number 167= Ring Group 168= RMATS r DID Night Answer Point 0 = Disable 1 1 = Enable e f I I I I 102 2-64 Revision 0 9104-091-l 02-NA Issue 3
Customer Data Entry Forms COMMANDS 501 - 580 TRUNK PROGRAMMING - Register 6 - DID Start Type 0 = Immediate Start 1 = Wink Stat-l 2 = Delay Dial - RESERVED - Incoming Address Signalling 0 = LoopDial Pulsing 1 = Battery-and-Ground Pulsing 2 = DTMF - N = Number of Digits Expected (1 - 9) - M = Number of Digits to be Absorbed (0 - 8) Digits to be Inserted 5 6 - 5- 6 Default 6 1 1 0 4 1 TYPE: 9104-091-l 02-NA Issue 3 Revision 0 l-02 2-65
Customer Data Entry Forms COMMANDS 501 + 580 TRUNK PROGRAMMING TYPE: r - Register 7 -r - Incoming Seizure Debounce Timer (01 - 15) x 10 ms - WinkTimer (3 + 6) x 50 ms - Permanent-Signal Partial-Dial Timer .(I +6)x5s - DID Disconnect Timer (3-6)x50ms Release Acknowledge Timer 002+12os l- a 1 b 1 c 1 d I e I f I g I h I i I 5 7 - 5 - 7 I Default I 7 I I I I I o I 4 I I I, I I I 102 2-66 Revision 0 9104-091-l 02-NA Issue 3
Customer Data Entrv Forms COMMAND 600 VERIFIED AUTHORIZATION CODE PROGRAMMING L I l- l- 11 DEFAULT VALUES - Register Number: 001 +.999 - VAC Activation: 0 = Disable, 1 = Enable - CDS for Authorization Code 0 = Disable, 1 -j 9 = COS 1 - 9 (for VAC) - ARS Routing Nilmber 1 +3=ARSRCSl -3(forVAC), 0 = Original RCS Number of Calling Device Authorization Code (1 to 8 digits) 9104-091-102-NA Issue 3 Revision 0 102 2-67
Customer Data Entry Forms COMMAND 700 ARS DIGIT COMPARISON TABLE PROGRAMMING r Entry Number 001 - 800 r Time-of- Day Table Number 01 -45 [ 1 [ . . 1 1 I 1 1 102 2-68 Revision 0 9104-091-l 02-NA Issue 3
Customer Data Entry Forms COMMA-NDS 701 - 745 ARS TIME-OF-DAY TABLE PROGRAMMING COMMAND 7 CO-MMAND 7 - -. I- r a 1 1 2 - Period Number - Start Hour 00 - 23 - Start Minute 00 + 59 Route List 001 + 200, 000 = not programmed RCS 1 Route List RCS 2 Route List RCS 3 Route List Ill I I I I I elf 1 al hl iI iI kl I Iml nl - Period Number - Start Hour 00 - 23 . - Start Minute 00 - 59 Route List 001 + 200, 000 = not programmed RCS 1 Route List RCS 2 Route List RCS 3 Route List I 1 I I I I I cldlelf I al hl i jI k llmln I I I - - ., _ - 0 0 0 0 0 0 0 0 0 Default - - - - 0 0 0 0 0 0 0 0 0 Default 9104-091- 02-NA Issue 3 Revision 0 102 2-69