    							Customer Data Entry (CDE) 
    COMMANDS 501 - 580 Trunk Programming -Slots 1 + 10 
    (Cont’d) - 
    Register 6 
    a 
    b c d e f g h i-j 
    6 
    1 1 0 4 1 
    a: 
    Register Number 
    b: 
    DID Start Type 
    0 = Immediate Start 
    1 = Wink Start 
    2 = Delay Dial 
    c: RESERVED 
    d: 
    Incoming Address Signaling 
    0 = Loop-Dial Pulsing 
    1 = Battery-and-Ground Pulsing 
    2 = DTMF 
    e: N : 
    Number Of Digits Expected (1 - 9) 
    f: M : 
    Number Of Digits To Be Absorbed (0 - 8) 
    Cl- j: X : Digits To Be Inserted 
    Note: 
    In orderto change the number of ‘X’digits, fields g - j must be programmed as ‘00’. This 
    clears the previous entry and allows a new “Digits to be Inserted” value to be entered. 
    210 4-50 
    Revision 0 9104-091-210-NA Issue 5  
    						
    							cau 
    Customer Data Entry Registers 
    COMMANDS 501 - 580 Trunk Programming - Slots 1 - 10 
    (Cont’d) 
    Register 7 
    a: 
    Register Number 
    b,c: Incoming Seizure Debounce Timer 
    (01 - 15)xiOms 
    d: Wink Timer 
    (3 - 6) x 50 ms 
    e: Permanent-Signal Partial-Dial Timer 
    (1 - 6) x 5 set 
    f: 
    DID Disconnect Timer 
    (3 - 6) x 50 ms 
    cl- i: Release Acknowledge Timer 
    002 - 120 set 
    9104-091-210-NA Issue 5 
    Revision 0 
    210 4-51  
    						
    							Customer Data Entry (CDE) 
    Verified Authorization Code Programming 
    4.15 Command 600 is used to program Verified Authorization codes (VAC) on the SX-50 
    system. Verified Authorization codes are required by the following features: Traveling 
    COS and Special DISA. Refer to Section 9104-091-l 05:NA, TRAVELING COS and 
    Section 9104-091-l 05-NA, SPECIAL DISA, for further details. 
    COMMAND 600 VERIFIED AUTHORIZATION CODE PROGRAtiMIN6 
    a,b,c: Register Number 001 - 999 
    d: 
    VAC Activation 
    0 = Disable 
    1 = Enable 
    e: 
    COS for Authorization Code 
    0 = Disable 
    1 - 9 = COS (for VAC) 
    f: ARS Routing Number 
    I 0 = Original RCS Number of Calling Device 
    1 - 3 = Routing Class of Service (for VAC) 
    g- n: Authorization Code (1 to 8 digits) 
    210 4-52 Revision 0 9104-091-210-NA Issue 5  
    						
    							w 
    Customer Data Entry Registers 
    ARS Programming 
    4.16 Commands 700 through 745 and 750 through 752 apply to the SX-50 system’s 
    Automatic Route Selection package. For detailed information refer to Section 
    9104-091-220-NA, Automatic Route Selection. 
    COMMAND 700 ARS DIGIT COMPARISON TABLE PROGRAMMING 
    si _ 
    a,b,c: Entry Number 001 - 800 
    d,e: Time-of-Day Table Number 01 -+ 45 
    9’ I: Dialed Digits String (field scrolls to provide up to 32 digits) 
    COMMANDS 701 + 745: ARS TIME-OF-DAY TABLE PROGRAMMING 
    a bcdefghijkimn 
    - - - - 
    0 0 0 0 0 0 0 0 0 
    a: 
    b,c: 
    d,e: 
    f,g,h: 
    i,j,k: 
    I,m,n: Period Number 1 - 6 
    Start Hour 00 - 23 
    Start Minute 00 + 59 
    RCS 1 Route List 
    001 - 200 
    000 = not programmed 
    RCS 2 Route List 
    001 - 200 
    000 = not programmed 
    RCS 3 Route List 
    001 - 200 
    000 = not programmed 
    9104-091-21GNA Issue 5 
    Revision 0 
    210 4-53  
    						
    							Customer Data Entry (CDE) 
    COMMAND 750 ARS ROUTE LIST TABLE PROGRAMMING 
    a 
    b c d e f g h i j k I m n o 
    - - - - - - - -. - - 
    - - 
    a,b,c: Route List Number 001 - 200 
    d,e,f: 1 st Choice Route Number 
    . 
    g,h,i: 2nd Choice Route Number 
    j,k,l: 
    3rd Choice Route Number 
    m,n,o: 4th Choice Route 
    COMMAND 751 ARS ROUTE TABLE PROGRAMMING 
    a 
    b c d e f g h 
    0 0 0 0 0 
    a,b,c: Route Number 001 - 100 
    d: 
    _ Trunk Group Number 1 - 6 
    e,f,g: Digit Modification Entry Number 001 --+ 100 
    h: Toll Calls 
    0 = Non-Toll 
    1 = Toll 
    COMMAND 752 ARS DIGIT MODIFICATION TABLE PROGRAMMING 
    a,b,c: Digit Modification Number 001 --, 100 
    d,e: Number of Digits to be Deleted 00 + 26 
    9’ I: Digits to Insert (maximum of 26 digits) 
    210 
    4-54 
    Revision 0 9104-091-210-NA Issue 5  
    						
    							5 . 
    PROGRAMMING ERRORS 
    General 
    5.1 The SX-50 system can detect certain errors made during CDE. The detection of a 
    programming error results in a display similar to that shown in Figure 5-1, Alarm 
    Message Format. The meaning of each code is listed in Table 2-2, Programming 
    Error Codes. 
    Exit From Error Mode 
    5.2 
    After the error code has been checked and the correct data determined, the 
    programmer can exit the Error Mode by: 
    4 pressing the QUIT softkey on the Attendant Console, 
    OR, 
    l pressing the CANCEL softkey from the Test Line (SUPERSET Telephone) 
    OR 
    l dialing *## from the Test Line (DTMF set), 
    OR 
    l flashing the switchhook twice on the Test Line (Rotary Dial set). 
    The system restores the original data and data entry begins at the start of the register. 
    10: 34 NO TRUNK RELEASE ACK. 
    ,A 12 C 
    ‘; 
    Alarm Code - 
    Equipment Number - 
    Explanatory message 
    Slot/Circuit (where applicable) I 
    Figure 5-l Alarm Message Format 
    9104-091-210-NA Issue5 Revision 0 
    05102 
    Yr 
    210 5-1  
    						
    							Customer Data Entry (CDE) 
    Table 5-l Programming Error Codes 
    Error Code Description 
    EOl Illegal Command identity 
    E02 Digit keyed while Access Mode Error displayed 
    E03 Directory Number already exists 
    E04 Data out of range 
    E05 Illegal Directory Number length 
    E06 Directory Number range insufficient 
    E07 Too many digits keyed 
    E08 Illegal Device range 
    E09 Write.protected command 
    El0 Insufficient software package level 
    El1 Write protected data 
    El2 Data field incomplete 
    El3 RESERVED 
    El4 Maximum Limit Exceeded 
    El5 Hunt Groups linked into a loop; e.g, linked Hunt Group 1 to Hunt Group 6 then linked 
    Hunt Group 6 to Hunt Group 1 
    El6 
    El7 
    El8 
    E20 
    E21 
    E22 
    E23 
    E24 
    E25 
    E26 
    E27 
    E28 
    E29 
    E30 
    E31 
    E32 Duplicate assignment of Programmable Function Key 
    Attempt to program non-idle key 
    SUPERSETTelephone Prime Line Programming Error 
    Invalid double-digit command 
    Directory number already in Ring Group 
    Device must be an extension 
    ARS Busy - Calls in progress 
    Digit String already programmed 
    Digit String register overflow 
    No Digit String entered 
    Digit area is full 
    The start time entered for this time period is earlier than or equal to the start time of 
    the preceding period. Time periods must be entered in ascending order. 
    The start time entered for this time period is later than the start time of the next peri- 
    od. Time periods must be entered in ascending order. 
    RESERVED 
    Attempt to program a DTS, DLS or Private Line in SUPERSET Telephone 
    Programming when the trunk is not assigned to a Trunk Group. Refer to Commands 
    501 - 580, Trunk Programming. 
    SUPERSET 4 Telephone key type conflict 
    Page 1 of 2 
    210 5-2 Revision 0 9104-091-210-NA Issue 5  
    						
    							Programming Errors 
    Table 5-l Programming Error Codes 
    (continued) 
    Error Code Dkscription 
    E33 Attempt to display System Security Code 
    E34 Attempt to display User Security Code 
    E35 Attempt to display DISA Access Code 
    E36 RESERVED 
    E37 Specified card type not found in slot position _ 
    E38 Attempt to overflow current Trunk Group 
    E39 Invalid Trunk Number keyed 
    E40 Invalid Auxiliary Attendant Equipment (must be a SUPERSETTelephone) 
    E41 Auxiliary Attendant not idle. 
    E42 Auxiliary Attendant Programming conflict. 
    E43 
    Invalid base Directory Number (Occurs when programming Commands 301 - 310). 
    E44 
    invalid Directory Number (Occurs when programming Commands 321 - 330). 
    E45 Contact monitor conflict. Attempted to assign as an answer point an ONS circuit 
    programmed as a contact monitor. 
    E46 VAC Length Conflict. Attempted to change length of VAC before deleting all existing 
    VACs 
    Page 2 of i 
    9104-091-210-NA Issue 5 
    Revision 0 210 53  
    						
    							Customer Data Entry (CDE) 
    210 5-4 Revision 0 9104-091-210-NA issue 5  
    						
    							issue 5 
    March, 1993 
    SX-50@ DIGITAL PRIVATE 
    AUTOMATIC BRANCH EXCHANGE 
    (DPABX) 
    ~ __... -~~--~..~. .- ~- ..~.~. ~~-~- -- _---- 
    Automatic 
    Route 
    Selection and 
    Toll Control 
    _..-___-.---- 
    &,F- d Tra emark of Mite1 Corporation. 
    opyright 1993, MM Corporation. 
    All rights reserved. 
    Printed in Canada. 
    @ 
    MITEL?  
    						
    All Mitel manuals Comments (0)

    Related Manuals for Mitel Sx 50 Dpabx Instructions Guide