Customer Data Entry (CDE) COMMANDS 501 - 580 Trunk Programming -Slots 1 + 10 (Cont’d) - Register 6 a b c d e f g h i-j 6 1 1 0 4 1 a: Register Number b: DID Start Type 0 = Immediate Start 1 = Wink Start 2 = Delay Dial c: RESERVED d: Incoming Address Signaling 0 = Loop-Dial Pulsing 1 = Battery-and-Ground Pulsing 2 = DTMF e: N : Number Of Digits Expected (1 - 9) f: M : Number Of Digits To Be Absorbed (0 - 8) Cl- j: X : Digits To Be Inserted Note: In orderto change the number of ‘X’digits, fields g - j must be programmed as ‘00’. This clears the previous entry and allows a new “Digits to be Inserted” value to be entered. 210 4-50 Revision 0 9104-091-210-NA Issue 5

cau Customer Data Entry Registers COMMANDS 501 - 580 Trunk Programming - Slots 1 - 10 (Cont’d) Register 7 a: Register Number b,c: Incoming Seizure Debounce Timer (01 - 15)xiOms d: Wink Timer (3 - 6) x 50 ms e: Permanent-Signal Partial-Dial Timer (1 - 6) x 5 set f: DID Disconnect Timer (3 - 6) x 50 ms cl- i: Release Acknowledge Timer 002 - 120 set 9104-091-210-NA Issue 5 Revision 0 210 4-51

Customer Data Entry (CDE) Verified Authorization Code Programming 4.15 Command 600 is used to program Verified Authorization codes (VAC) on the SX-50 system. Verified Authorization codes are required by the following features: Traveling COS and Special DISA. Refer to Section 9104-091-l 05:NA, TRAVELING COS and Section 9104-091-l 05-NA, SPECIAL DISA, for further details. COMMAND 600 VERIFIED AUTHORIZATION CODE PROGRAtiMIN6 a,b,c: Register Number 001 - 999 d: VAC Activation 0 = Disable 1 = Enable e: COS for Authorization Code 0 = Disable 1 - 9 = COS (for VAC) f: ARS Routing Number I 0 = Original RCS Number of Calling Device 1 - 3 = Routing Class of Service (for VAC) g- n: Authorization Code (1 to 8 digits) 210 4-52 Revision 0 9104-091-210-NA Issue 5

w Customer Data Entry Registers ARS Programming 4.16 Commands 700 through 745 and 750 through 752 apply to the SX-50 system’s Automatic Route Selection package. For detailed information refer to Section 9104-091-220-NA, Automatic Route Selection. COMMAND 700 ARS DIGIT COMPARISON TABLE PROGRAMMING si _ a,b,c: Entry Number 001 - 800 d,e: Time-of-Day Table Number 01 -+ 45 9’ I: Dialed Digits String (field scrolls to provide up to 32 digits) COMMANDS 701 + 745: ARS TIME-OF-DAY TABLE PROGRAMMING a bcdefghijkimn - - - - 0 0 0 0 0 0 0 0 0 a: b,c: d,e: f,g,h: i,j,k: I,m,n: Period Number 1 - 6 Start Hour 00 - 23 Start Minute 00 + 59 RCS 1 Route List 001 - 200 000 = not programmed RCS 2 Route List 001 - 200 000 = not programmed RCS 3 Route List 001 - 200 000 = not programmed 9104-091-21GNA Issue 5 Revision 0 210 4-53

Customer Data Entry (CDE) COMMAND 750 ARS ROUTE LIST TABLE PROGRAMMING a b c d e f g h i j k I m n o - - - - - - - -. - - - - a,b,c: Route List Number 001 - 200 d,e,f: 1 st Choice Route Number . g,h,i: 2nd Choice Route Number j,k,l: 3rd Choice Route Number m,n,o: 4th Choice Route COMMAND 751 ARS ROUTE TABLE PROGRAMMING a b c d e f g h 0 0 0 0 0 a,b,c: Route Number 001 - 100 d: _ Trunk Group Number 1 - 6 e,f,g: Digit Modification Entry Number 001 --+ 100 h: Toll Calls 0 = Non-Toll 1 = Toll COMMAND 752 ARS DIGIT MODIFICATION TABLE PROGRAMMING a,b,c: Digit Modification Number 001 --, 100 d,e: Number of Digits to be Deleted 00 + 26 9’ I: Digits to Insert (maximum of 26 digits) 210 4-54 Revision 0 9104-091-210-NA Issue 5

5 . PROGRAMMING ERRORS General 5.1 The SX-50 system can detect certain errors made during CDE. The detection of a programming error results in a display similar to that shown in Figure 5-1, Alarm Message Format. The meaning of each code is listed in Table 2-2, Programming Error Codes. Exit From Error Mode 5.2 After the error code has been checked and the correct data determined, the programmer can exit the Error Mode by: 4 pressing the QUIT softkey on the Attendant Console, OR, l pressing the CANCEL softkey from the Test Line (SUPERSET Telephone) OR l dialing *## from the Test Line (DTMF set), OR l flashing the switchhook twice on the Test Line (Rotary Dial set). The system restores the original data and data entry begins at the start of the register. 10: 34 NO TRUNK RELEASE ACK. ,A 12 C ‘; Alarm Code - Equipment Number - Explanatory message Slot/Circuit (where applicable) I Figure 5-l Alarm Message Format 9104-091-210-NA Issue5 Revision 0 05102 Yr 210 5-1

Customer Data Entry (CDE) Table 5-l Programming Error Codes Error Code Description EOl Illegal Command identity E02 Digit keyed while Access Mode Error displayed E03 Directory Number already exists E04 Data out of range E05 Illegal Directory Number length E06 Directory Number range insufficient E07 Too many digits keyed E08 Illegal Device range E09 Write.protected command El0 Insufficient software package level El1 Write protected data El2 Data field incomplete El3 RESERVED El4 Maximum Limit Exceeded El5 Hunt Groups linked into a loop; e.g, linked Hunt Group 1 to Hunt Group 6 then linked Hunt Group 6 to Hunt Group 1 El6 El7 El8 E20 E21 E22 E23 E24 E25 E26 E27 E28 E29 E30 E31 E32 Duplicate assignment of Programmable Function Key Attempt to program non-idle key SUPERSETTelephone Prime Line Programming Error Invalid double-digit command Directory number already in Ring Group Device must be an extension ARS Busy - Calls in progress Digit String already programmed Digit String register overflow No Digit String entered Digit area is full The start time entered for this time period is earlier than or equal to the start time of the preceding period. Time periods must be entered in ascending order. The start time entered for this time period is later than the start time of the next peri- od. Time periods must be entered in ascending order. RESERVED Attempt to program a DTS, DLS or Private Line in SUPERSET Telephone Programming when the trunk is not assigned to a Trunk Group. Refer to Commands 501 - 580, Trunk Programming. SUPERSET 4 Telephone key type conflict Page 1 of 2 210 5-2 Revision 0 9104-091-210-NA Issue 5

Programming Errors Table 5-l Programming Error Codes (continued) Error Code Dkscription E33 Attempt to display System Security Code E34 Attempt to display User Security Code E35 Attempt to display DISA Access Code E36 RESERVED E37 Specified card type not found in slot position _ E38 Attempt to overflow current Trunk Group E39 Invalid Trunk Number keyed E40 Invalid Auxiliary Attendant Equipment (must be a SUPERSETTelephone) E41 Auxiliary Attendant not idle. E42 Auxiliary Attendant Programming conflict. E43 Invalid base Directory Number (Occurs when programming Commands 301 - 310). E44 invalid Directory Number (Occurs when programming Commands 321 - 330). E45 Contact monitor conflict. Attempted to assign as an answer point an ONS circuit programmed as a contact monitor. E46 VAC Length Conflict. Attempted to change length of VAC before deleting all existing VACs Page 2 of i 9104-091-210-NA Issue 5 Revision 0 210 53

Customer Data Entry (CDE) 210 5-4 Revision 0 9104-091-210-NA issue 5

issue 5 March, 1993 SX-50@ DIGITAL PRIVATE AUTOMATIC BRANCH EXCHANGE (DPABX) ~ __... -~~--~..~. .- ~- ..~.~. ~~-~- -- _---- Automatic Route Selection and Toll Control _..-___-.---- &,F- d Tra emark of Mite1 Corporation. opyright 1993, MM Corporation. All rights reserved. Printed in Canada. @ MITEL?