Laboratory Activity (1.3) - Peripheral (1) USING 25 PAIR CABLES WITH MALE CONNECTORS ON ONE END, CONNECT FIVE CABLES TO THE FOLLOWING RECEPTACLES: CN 0, CN 1, CN 10, CN 11, CN 12. (2) RUN CABLES NEATLY FROM THE OMNI SBCS CABINET USING SCREWS TO FASTEN THE CONNECTORS TIGHTLY TO THE RECEPTACLES. CONNECT EACH CABLE TO THE CDF BLOCK DESIGNATED BELOW: (A) CN 0 - FIRST STATION CDF BLOCK (B) CN 1 - SECOND STATION CDF BLOCK (C) CN 10 - FIRST STATION CDF BLOCK (D) CN 11 - SECOND STATION CDF BLOCK (E) CM 12 - POWER FAIL TRANSFER CDF BLOCK (3) ENSURE THAT CDF BLOCKS ARE MOUNTED TO THE WALL. MARK EACH CABLE FOR EASY IDENTIFICATION. LAB MILESTONE: . VERIFY THAT ALL CDF CABLES ARE INSTALLED CORRECTLY. 0 ASK INSTRUCTOR TO INSPECT INSTALLATION OF CABLES AND INITIAL YOUR PERFORMANCE CHECKLIST. . TURN TO REVIEW EXERCISE 1.3 AND ANSWER QUESTIONS l-3. 1.72
tory ffktivity (1.3) - Peripheral tion (Contin (4) WIRE CROSS CONNECTIONS AND INSTALL THE FOLLOWING STATION INSTRUMENTS USING THE DESIGNATED CONFIGURATIONS: -.- (A) - (W CG’ (C) -/CD) J (El u:.l (F) ‘ii! (G) b’: (H) LA) ’ (J) CS-10 TELEPHONE USING 8EKC CARD IN SLOT 01, CIRCUIT 0. DEFAULT STATION DIRECTORY NUMBER WILL BE 208. DO NOT CONNECT THIS STATION TO THE MODULAR JACK AT THIS TIME. IT WILL BE ADDED DURING A DATA BASE PROGRAMMING LAB ACTIVITY. CS-10 TELEPHONE USING 8EKC CARD IN SLOT 01, CIRCUIT 7. DEFAULT STATION DIRECTORY NUMBER WILL BE 215. CS-20 TELEPHONE USING 8EKC CARD IN SLOT 01, CIRCUIT 4. DEFAULT STATION DIRECTORY NUMBER WILL BE 212. CS-20 TELEPHONE USING 8EKC CARD IN SLOT 01, CIRCUIT 6. DEFAULT STATION DIRECTORY NUMBER WILL BE 214. BLFlDSS CONSOLE USING 8EKC CARD IN SLOT 01, CIRCUIT 5. BLF/DSS WILL BE CONNECTED TO CS-20 TELEPHONE AT DIRECTORY NUMBER 212. BLFIDSS CONSOLE USING 8EKC CARD IN SLOT 01, CIRCUIT 3. DO NOT CONNECT THIS BLFlDSS AT THIS TIME. IT WILL BE ADDED DURING A DATA BASE PROGRAMMING LAB ACTIVITY. THIS BLF/DSS WILL BE CONNECTED IN FUTURE TO THE CS-20 TELEPHONE AT DIRECTORY NUMBER 214. SINGLE LINE TELEPHONE INSTRUMENT USING 8SLC CARD IN SLOT 02, CIRCUIT 0. THIS DIRECTORY NUMBER WILL BE 216. 9 SINGLE LINE TELEPHONE INSTRUMENT USING 8SLC CARD IN SLOT 02. CIRCUITPI. DEFAULT STATION DIRECTORY NUMBER WILL BE -22-3: ,:I$ ‘;: v CSD TELEPHONE USING ~DTC CARD IN SLOT 00, CIRCUIT 0. DEFAULT STATION< DIRECTORY NUMBER WILL BE 200. CSD TELEPHONE USING 8DTC CARD IN SLOT 00, CIRCUIT 1. DEFAULT STATION DIRECTORY NUMBER WILL BE 201. (5) LABEL EACH INSTRUMENT WITH THE APPROPRIATE STATION DIRECTORY NUMBER AND EQUIPMENT NUMBER (CARD SLOT AND CIRCUIT NUMBER). LAB MILESTONE: . VERIFY THAT ALL STATION CROSS CONNECTIONS ARE WIRED AND THAT STATION INSTRUMENTS ARE INSTALLED CORRECTLY. . ASK INSTRUCTOR TO INSPECT CROSS CONNECTIONS AND STATION INSTALLATION AND INITIAL YOUR PERFORMANCE CHECKLIST. l TURN TO REVIEW EXERCISE 1.3 AND ANSWER QUESTIONS 4- 6 1.73
Laboratory Activity (1.3) - Peripheral Hnstallatio (Continue GTE OMNU SBCS (6) WIRE CROSS CONNECTIONS FOR THE POWER FAIL TRANSFER STATION: (A) SINGLE LINE TELEPHONE INSTRUMENT USING 8SLC CARD IN SLOT 02, CIRCUIT 0 TO POWER FAIL TRANSFER CDF BLOCK. (B) POWER FAIL TRANSFER CARD (GPFT) IN SLOT 22, CIRCUIT 0 TO CO TRUNK ON 4BWC CARD IN SLOT 18, CIRCUIT 0. LAB MILESTONE: e VERIFY THAT POWER FAIL TRANSFER CROSS CONNECTIONS ARE WIRED CORRECTLY. . ASK INSTRUCTOR TO INSPECT THE CROSS CONNECTIONS AND INITIAL YOUR PERFORMANCE CHECKLIST. . TURN TO REVIEW EXERCISE 1.3 AND ANSWER QUESTION 7. 1.74
(7) VERIFY THAT POWER FAlL TRANSFER TRUNKS HAVE BEEN INSTALLED FROM CARD SLOT 18, CIRCUIT 0. WIRE CROSS CONNECTIONS AND INSTALL THE FOLLOWING TRUNK LINES USING THE DESIGNATED CONFIGURATIONS: (A) THREE ADDITIONAL CO TRUNK LINES USING 4BWC CARD IN SLOT 18, CIRCUITS 1,2, AND 3. (B) TWO LOOP TIE LINES USING 2TTL CARD IN SLOT 16, CIRCUITS 0 AND 1. THESE TIE LINES WILL BE USED TO ACCESS OTHER OMNI SBCS LAB SYSTEMS. INSTRUCTOR WILL PROVIDE INSTRUCTIONS REGARDING CONNECTION. (6) TWO E&M TIE LINE (TYPE II) USING 2TTE CARD IN SLOT 17, CIRCUITS 0 AND 1. THESE TIE LINES WILL BE USED TO ACCESS OTHER OMNI SBCS LA5 SYSTEMS. INSTRUCTOR WILL PROVIDE INSTRUCTIONS REGARDING CONNECTIONS. LAB MILESTONE: . VERIFY THAT ALL TRUNK LINE CROSS CONNECTIONS ARE WIRED CORRECTLY. @ ASK INSTRUCTOR TO INSPECT CROSS CONECTIONS AND INITIAL YOUR PERFORMANCE CHECKLIST. . TURN TO REVIEW EXERCISE 1.3 AND ANSWER QUESTlbN 8. SUBMIT YOUR COMPLETED REVIEW EXERCISE TO THE INSTRUCTOR FOR GRADING. 1.75
(8) CONNECT PORTABLE MAINTENANCE PANEL (PMP) TO OMNI SBCS CABINET. CONNECT DIN PLUG OF EPSON CABLE #715 TO PORT MARKED “RS-232-C” ON BACK OF PMP. CONNECT DB-25 CONNECTOR END OF CABLE TO PORT CN13 (I/O 0) ON THE SBCS CABINET. (9) ENSURE THAT BOTH OMNI SBCS AND PMP POWER SWITCHES ARE OFF. (10) INSTALL FLOPPY DISKETTE UNIT TO PMP USING PROCEDURE FOUND IN THE STUDENT WORKBOOK. DO NOT POWER ON THE PMP OR FLOPPY DISKETTE DRIVE UNIT UNTIL INSTRUCTED TO DO SO DURING THE INITIALIZATION LAB ACTIVITY. (11) CONNECT SMDR PRINTER CABLE TO PORT CN14 (I/O 1) ON THE SBCS CABINET. INSTRUCTOR WILL PROVIDE SPECIAL INSTRUCTIONS RELATING TO TYPE OF PRINTER BEING INSTALLED. PORT CONFIGURATION REQUIREMENTS WILL BE DISCUSSED DURING THE DATA BASE ADMINISTRATION MODULE OF THIS COURSE. DO NOT POWER ON SMDR PRINTER UNTIL DIRECTED TO DO SO. LAB MILESTONE: l VERIFY THAT PORTABLE MAINTENANCE PANEL, FLOPPY DISKETTE DRIVE, AND SMDR PRINTER ARE CORRECTLY INSTALLED. . ASK INSTRUCTOR TO INSPECT THESE INSTALLATIONS AND INITIAL YOUR PERFORMANCE CHECKLIST. o TURN TO REVIEW EXERCISE 1.3 AND ANSWER QUESTIONS 9-12. SUBMIT YOUR COMPLETED REVIEW EXERCISE TO THE INSTRUCTOR FOR GRADING. . YOU HAVE NOW COMPLETED THE BASIC PERIPHERAL INSTALLATION LAB ACTIVITY. 1.76
COMPLETE ALL OR PART OF THE FOLLOWlNG ACTIVITY IF TlME PERMITS OR IF INSTRUCTOR DIRECTS YOU TO DO SO. (1) WIRE CROSS CONNECTIONS AND INSTALL ONE OR BOTH OF THE FOLLOWING OPTIONAL PERIPHERAL EQUIPMENT USING THE DESIGNATED CONFIGURATIONS BELOW: (A) NIGHT BELL USlNG 8SLC CARD IN SLOT 02, CIRCUIT 3. (B) MUSIC SOURCE FOR MUSIC-ON HOLD USING 4BWC CARD IN SLOT 18, CIRCUIT 2. LAB MILESTONE: 8 VERIFY THAT NIGHT BELL AND MUSIC SOURCE ARE WIRED AND INSTALLED CORRECTLY. @ ASK INSTRUCTOR TO INSPECT CROSS CONNECTIONS AND INITIAL YOUR PERFORMANCE CHECKLIST. e TURN TO REVIEW EXERCISE 1.3 AND ANSWER OPTIONAL QUESTIONS 13 AND 14. SUBMIT YOUR COMPLETED REVIEW EXERCISE TO THE INSTRUCTOR FOR GRADING. @ YOU HAVE NOW COMPLETED THE OPTIONAL PERIPHERAL INSTALLATION LAB ACTIVITY. 1.77
Review Exercise (1.3) - Peripheral I tisn INSTRUCTIONS: THE FOLLOWING EXERClSE CONSISTS OF MULTIPLE CHOICE, FILL IN THE BLANK OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E. STUDENT WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 1. WHAT CARD SLOTS AND CIRCUITS DO THESE SYSTEM CABLES SUPPORT (ALL SPACES WILL NOT BE REQUIRED); CABLE CARD SLOT / CIRCUITS CARD SLOT / CIRCUITS CARD SLOT / CIRCUITS 0 10 11 12 2. DESCRIBE THE FUNCTIONS OF CABLE NUMBER 12. 3. IF ALL CIRCUITS ON THE LINE AND TRUNK CARDS YOU INSTALLED WERE USED, HOW MANY STATIONS AND TRUNK LINES COULD ACTUALLY BE INSTALLED? STATIONS TRUNKS 1.78
ewiew 4. COMPLETE THE FOLLOWING DIAGRAM INDICATING THE CROSS CONNECTIONS THAT WERE MADE FOR THE SIX EKT TELEPHONES. ONE OF THE CS-10 TELEPHONES HAS BEEN COMPLETED, AS AN EXAMPLE. cs-20 (CKT4) _ - _ - _ - _ - _ - _ - _ - _ - _ _ _ - _ - _ - _ - _ - _ - _ - _ - _ - ” - _ - _ - _ - _ - _ - _ _ _ - _ - - - _ - _ - _ - _ - - - _ - _ - _ - _ - _ _ _ - _ - _ - CABLE 0. MODULAR JACK CABLE 1 cs-10 (CKTO)
eview Exercise (1.3) - Peripheral ati 5. COMPLETE THE FOLLOWING DIAGRAM INDICATING THE CROSS CONNECTIONS THAT WERE MADE FOR THE TWO SINGLE LINE TELEPHONES. CABLE 1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1.80 SLT (CKTO) I I ET2 t 0 SLT (CKT7)
ewiew Exercise 7. COMPLETE THE FOLLOWING DIAGRAM INDICATING THE CROSS CONNECTIONS THAT WERE MADE FOR THE POWER FAILURE TRANSFER INSTALLATION (INCLUDE TRUNK AND INSTRUMENT CROSS CONNECTIONS, AS WELL AS CROSS CONNECTIONS TO THE THREE CARDS). CABLE 1 (TO 8SLC) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1.81