    							Programming Station Message 
    etail Recorder/SMDR 
    a?wt F 
    @ TIME MESSAGE IS PRINTED WITH SMDR REPORT TO SEPARATE EACH SMDR MESSAGE. TIME INCRE- 
    MENTS BY HOUR. 
    09:27 02107186 
    (1) (2) 
    Time Date 
    . SAMPLE OUTPUT: 
    08:15 00.00.36 ST 0201 Cl234 1600 07035344789 123456780123 00 00 
    (1) 
    (2) (3) (4) (5) (6) (7) (8) (0% (10) 
    (I) = Time of call origination 
    (2) = Duration of call 
    (3) = Calling party identification: 
    ST = Station 
    AT = Attendant 
    TI = TIE trunk 
    (4) = Originating Station number 
    (5) = Trunk Identification and Trunk number: 
    c: CO trunk DDD: Trunk number 
    F: FX trunk 
    w: WATS trunk 
    T: TIE trunk 
    0.5) = Trunk access code (also when line button on EKT is used, access code is output) 
    (7) = Directory number dialed (maximum 20 digits) 
    (8) = Account code (if not specified, no code is output) 
    (9) = Tenant number (if not specified, no tenant number is output) 
    (IO) = Metering group (if not specified, no metering group is output) 
    2.156  
    						
    							Programming Station Message 
    Detail Recorder/CMC 
    Command Summary 
    CATEGORY 
    l OUTGOING MDR 
    l MDR TRUNK SCREEN 
    . CLASS OF RESTRICTION 
    . TENANT 
    . CALL DURATION 
    CMC TABLE 
    FUNCTION 
    CMC-500 SELECTS CO, TIE, ACCOUNT AND TOLL 
    FOR SMDR OUTPUT 
    CMC-501 SELECTS TRUNK GROUPS FOR MDR 
    OUTPUT 
    CMC-502 
    SELECTS COR GROUPS FOR MDR OUTPUT 
    CMC-503 SELECTS TENANTS FOR SMDR OUTPUT 
    CMC-504 
    SETS MINIMUM CALL DURATION FOR MDR 
    REGISTRATION 
    NOTE: REFER TO MODULE Ill FOR SMDR MAINTENANCE COMMANDS 
    (CMC-705) AND CMC-901). 
    2.157  
    						
    							- 
    ,, 
    Laboratory Activity - Station Message 
    etail 
    Recsr rogramming 
    GTE OMNU SBCS 
    PERFORM THE FOLLOWING PROGRAMMING TASKS IN THE SEQUENCE 
    OUTLlNED BELOW USING THE SAMPLE WORK ORDERS AND IN ACCOR- 
    DANCE WITH THE GTE OMNI SBCS GTEP MANUAL. COMPLETE THE REVIEW 
    EXERCISE QUESTIONS PERTAINING TO STATION MESSAGE DETAIL RE- 
    CORDER PROGRAMMING UPON COMPLETION OF THIS LABORATORY 
    ACTIVITY. 
    WORK ORDER #2.8 
    ZOMPANY NAME: NU SYSTEM CO. PHONE #: (703) 5551212 
    -0CATION: RESTON, VIRGINIA WORK ORDER 
    #2.8 (TASK #l) 
    IRIGINATOR: TELECOMMUNICATIONS MANAGER 
    TASKS: 
    l Determine SMDR output for system parameters with CMC-500. 
    (1) Assign both tie line outgoing connections with (1) Perform programming changes for Station 
    “no SMDR output”. Message Detail Recorder. 
    (2) Change toll call flag to indicate “SMDR output (2) Check/test the operation of changes after 
    for toll calls only”. completion of this portion of the laboratory 
    2.158  
    						
    							Laboratory Activity - Station 
    Message Detail Recorder 
    Programming (Continued) 
    WORK ORDER #2.8 
    COMPANY NAME: NU SYSTEM CO. 
    LOCATION: RESTON, VIRGINIA 
    ORIGINATOR: TELECOMMUNICTIONS MANAGER 
    TASKS: PHONE #: (703) 5551212 
    WORK ORDER #2.8 (TASK #2) 
    l Establish minimum call duration for SMDR with CMC-504. 
    PARAMETERS: 
    INSTRUCTIONS: 
    (1) Specify 45 seconds for “minimum call duration” (1) Perform programming changes for Station 
    to receive SMDR output. Message Detail Recorder. 
    (2) Check/test the operation of changes after 
    completion of this portion of the laboratory 
    activity. 
    (3) Proceed to next work order task: 
    2.159  
    						
    							oratory wity - Station Message 
    tail .Reco mming (Continued) 
    WORK ORDER #2.8 
    :OMPANY NAME: NU SYSTEM CO. PHONE #: (703) 555-1212 
    .OCATION: RESTON, VIRGINIA WORK ORDER #2.8 (TASK #3) 
    )RfCfNATCR. TELECOMMUNICATIONS MANAGER 
    -ASKS: 
    e Assign SMDR output for COR with CMC-502. 
    ‘ARAMETERS. 
    (1) Change COR 3 and 4 to indicate “no SMDR 
    OUTPUT”. INSTRUCTIONS: 
    (1) Perform programming changes for Station 
    Message Detail Recorder. 
    (2) Check/test the operation of changes after 
    completion of this portion of the laboratory 
    activity. 
    (3) complete review exercise questions l-8. 
    NOTE: 
    Tenant Group SMDR output was assigned 
    previously during Special System 
    Configuration laboratory activity with 
    CMC-503. 
    LAB MILESTONE: 
    . VERIFY THAT ALL PROGRAMMING CHANGES REQUESTED IN WORK ORDERS HAVE 
    BEEN PERFORMED CORRECTLY. 
    e ASK INSTRUCTOR TO INSPECT STATION MESSAGE DETAIL RECORDER AND INITIAL 
    YOUR PERFORMANCE CHECKLIST. 
    e MAKE CERTAIN QUESTIONS l-8 OF REVIEW EXERCISE 2.8 HAVE BEEN COMPLETED 
    BEFORE SUBMITTING TO THE INSTRUCTOR FOR GRADING. 
    2.160  
    						
    							Review Exercise - Station Message Detail 
    Recorder (2.8) 
    GTE OMNU SBCS 
    INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL 
    IN THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E. STUDENT 
    WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO 
    INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 
    1. 
    2. 
    3. 
    4. 
    5. THE FOLLOWING INFORMATION IS RECORDED FOR EVERY CALL IF SMDR OUTPUT IS 
    SELECTED: ~ 
    A. TIME OF CALL ORIGINATION, CALL DURATION, AND CLASS OF RESTRICTION SELECTION. 
    B. CALL DURATION, CALLING PARTY IDENTIFICATION, AND TOLL CALLS. 
    C. CALL DURATION, ORIGINATING STATION NUMBER, AND TRUNK ACCESS CODE. 
    D. TIME OF CALL ORIGINATION, OVERTIME CALLS, AND METERING GROUP NUMBER. 
    WHAT CMC COMMAND, PARAMETERS AND SETTINGS WOULD BE REQUIRED TO ESTABLISH 
    SMDR OUTPUT FOR OUTGOING CO CONNECTIONS, AND TOLL AND NON-TOLL CALLS? 
    SMDR OUTPUT FOR TRUNKS IS IDENTIFIED ON PRINTOUT BY 
    WHY MIGHT A MINIMUM CALL DURATION TO RECEIVE SMDR OUTPUT BE SELECTED? 
    WHAT CMC COMMAND, PARAMETERS, AND SETTINGS WOULD BE REQUIRED TO ESTABLISH 
    A MINIMUM CALL DURATION OF 1% MINUTES? 
    2.162  
    						
    							Review Exercise 
    - Station Message 
    Detail Recorder 
    (2.8) 
    GUE c&MN/ SBCS 
    6. WHAT CMC COMMAND, PARAMETERS, AND SETTlNG WOULD BE REQUIRED TO PROVIDE SMDR 
    OUTPUT FOR COR LEVELS 6 AND 16? 
    7. IS IT NECESSARY FOR ALL FIVE TENANTS TO RECEIVE SMDR OUTPUT? 
    PLEASE EXPLAIN 
    8. MATCH EACH OF THE FOLLOWING CMC COMMANDS WITH ITS CORRECT DEFINITION: 
    CMC-500 
    A. SMDR COR SCREENING ASSIGNMENT 
    CMC-501 
    B. SMDR CALL DURATION SCREENING ASSIGNMENT 
    CMC-502 
    C. SMDR OUTGOING CONNECTION SCREENING ASSIGNMENT 
    CMC-503 D. SMDR TENANT SCREENING ASSIGNMENT 
    CMC-504 
    E. SMDR TRUNK GROUP SCREENING ASSIGNMENT 
    CMC-705 
    F. SMDR IN/OUT OF SERVICE 
    2.163  
    						
    							DATA BASE ADMINISTRATION 
    Programming Toll and 
    Multi-Digit Restriction 
    2.164  
    						
    							abling Objective 
    GIVEN: 
    @ GTE OMNI SBCS 
    . GTE OMNI SBCS PERIPHERALS 
    @ PORTABLE MAINTENANCE PANEL 
    @ GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE 
    0 LABORATORY ACTIVITY 
    - PROGRAMMING TOLL AND MULTI-DIGIT 
    RESTRICTION PROGRAMMING 
    @ REVIEW EXERCISE 
    ACTION: 
    . USE OMNI SBCS PROGRAMMING TOOLS AND EQUIPMENT TO: 
    - ASSIGN TOLL AND TRUNK GROUP RESTRICTIONS TO CLASS 
    OF RESTRICTION TABLE. 
    - CREATE AREA CODE, OFFICE CODE, AND COMBINED AREA/ 
    OFFICE CODE MULTI-DIGIT RESTRICTION TABLES. 
    - ESTABLISH TOLL AND OPERATOR CALL RESTRICTION NUMBER. 
    - IDENTIFY AND ASSIGN TOLL AND OPERATOR PREFIX CODES 
    FOR TRUNK DIAL GROUP NUMBERS. 
    . COMPLETE REVIEW EXERCISE. 
    CRITERIA: 
    0 DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE WITH 
    PROCEDURES OUTLINED IN OMNI SBCS GTEP MANUAL AND OMNI 
    SBCS GTEP MANUAL AND OMNI SBCS STUDENT WORKBOOK. 
    @ REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN 
    ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING 
    ORGANIZATION. 