Home > GTE > Communications System > GTE Omni Scbs Installation And Maintenance Manual

GTE Omni Scbs Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GTE Omni Scbs Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 656
    							f”~‘ ‘.\‘\/‘!:  :‘\Laboratory Activity 
    - Package C Data Base
    Adminstration (5.3) (Continued)
    GTE aww SEESPART 3: DIRECT INWARD DIALING
    I.PRIOR TO PROGRAMMING, EMULATE A DID LINE BY PUNCHING THE TIP/RING WIRES FROM A SLT TO THE TIP/RING
    WIRES OF A LOOP TIE TRUNK CIRCUIT (USE EQUIPMENT NUMBER 160).
    2.USE THE CMC-250 TO ASSIGN A DID TRUNK USING THE FOLLOWING PARAMETER VALUES:
    EQUIPMENT NUMBER (PI) = 160
    TYPE OF TRUNK (P2) = 13 (LOOP DIAL)
    TRUNK GROUP NUMBER (P3) = 57
    OPERATION MODE (P4) = 1 (INCOMING)
    SIGNALING 
    (85) = 1 (FIXED)
    START MODE (P6) = 3 (IMMEDIATE)
    3.ASSIGN COS/COR TO THE DID TRUNK LINE WITH CMC-252, USING THE FOLLOWING PARAMETERS VALUES:
    TRUNK GROUP NUMBER (PI) = 57
    DAY COS (P2) = 1
    NIGHT COS (P3) = 16
    DAY COR (P4) = 1NIGHT COR (P5) = 16
    4.ASSIGN THE RECEIVED DI,GIT LENGTH AND PREFIX CODE TO THE DID TRUNK WITH CMC-430, USING THE FOLLOWING
    PARAMETER VALUES:TRUNK GROUP NUMBER (PI) = 57
    RECEIVED DIGIT LENGTH (P2) = 3 (RECIEVED DIGIT LENGTH FROM CO PROVIDING DID)
    PREFIX CODE (P3) = BLANK
    DISA DIRECTORY NUMBER = 123 (SIMULATED)
    DISA AUTHORIZATION CODE = 456 (SIMULATED)
    5.97 
    						
    							Laboratory Activity - Package C Data Base
    Adminstration (5.3) (Continued)
    GTE OMNU a3cs
    PART 4:KEY SYSTEM FEATURES
    1. REMOVE ATTENDANT CONSOLE.
    2.COLD RESTART THE SYSTEM.
    3.CHECK/CONFIRM KEY SYSTEM FEATURE CHANGES ON EKT INSTRUMENT BUTTONS.
    5.98 
    						
    							Review Exercise - Package C
    Data Base 
    Adminstration(5.3)INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, 
    FILL IN THE
    BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E., STUDENT WORKBOOK, NOTES,
    AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO INSTRUCTOR FOR GRADING WHEN
    LAST QUESTION HAS BEEN COMPLETED.
    1.WHAT INSTALLATION OR DATA BASE PROGRAMMING STEPS ARE REQUIRED TO ALLOW A PREVIOUSLY
    INSTALLED 
    BLF/DSS MODULE TO FUNCTION AS A ROOM STATUS INDICATOR?
    2.(TRUE OR FALSE) A TRUNK GROUP WITH AN INCOMING CALL TERMINATION PRIORITY OF 1WOULD BE ANSWERD BY THE ATTENDANT CONSLE BEFORE ANOTHER TRUNK GROUP WITH A PRIORITY
    OF 3.3. 
    CMC-IS USED TO CREATE A NIGHT ANSWER GROUP FOR AN ATTENDANT CONSOLE OVERFLOW
    STATION, THEN TO ASSIGN “ALL TENANTS” TO BE ANSWERED BY THE OVERFLOW STATION.
    4. THE
    FEATURE BUTTON MUST BE ASSIGNED TO EITHER THE ATTENDANT
    CONSOLE OR CSD DESIGNATED TO SERVE AS THE HOTEL/MOTEL FRONT DESK CONSOLE.
    5.“AUTOMATIC WAKE-UP REGISTRATION/CANCELLATION BY GUEST ROOM” IS AN EXAMPLE OF A
    MESSAGE WHICH CAN BE RECORDED BY THE HOTEL/MOTEL PRINTER.
    6.THE DTMF AUTHORIZATION CODE REQUIRED BY DISA USERS IS ASSIGNED WITH CMC-
    5.99 
    						
    							ew Exercise = Package CDntinued)
    7.
    8.
    9.
    10.CMC-430 ASSIGNS 
    DISA DIRECTORY NUMBERS AND AN AUTHORIZATON CODE TO A
    TRUNK LINE.
    A CS-10 OR CS-20 WHICH WILL SERVE AS A VOICE STATION ASSOCIATED WITH A DIU MUST BE
    ASSIGNED WITH 
    CMC-, AND HAVE THEFEATURE BUTTON ASSIGNED
    WITH CMC-203.
    EKT INSTRUMENTS CONNECTED TO CARD SLOT
    RING ON ALL INCOMING CALLS IN A KEY
    TELEPHONE BUTTON ARRANGEMENT.
    MATCH EACH OF THE FOLLOWING CMC COMMANDS WITH ITS CORRECT FUNCTION:
    CMC-223
    A. ASSIGNS TRUNK 
    COSICOR TO DID TRUNKS
    CMC-355
    B. ASSIGNS 
    DISA STANDARD TO A GROUND STRAT TRUNK
    CMC-252
    C. ASSIGNS GUEST ROOM NUMBERS TO ROOM STATUS INDICATOR LAMPS
    CMC-231D. ASSIGNS ATTENDANT CONSOLE SERVICES TO FEATURE BUTTONS
    CMC-250E. ASSIGNS DATA STATION ATTRIBUTES (Ill) AND RS-232-C 
    SlGNAL MODES
    5.100 
    						
    							PACKAGE C
    MAINTENANCE
    5.101 
    						
    							5.4 EnablingObiective
    GIVEN:0
    0
    0
    0
    0GTE 
    OMNI SBCS
    GTE 
    OMNI SBCS PACKAGE C EQUIPMENT AND PERIPHERALS
    ATTENDANT CONSOLE (ASSIGNED AS MASTER CONTROL TELEPHONE IN
    DATA BASE)GTE 
    OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE
    REVIEW EXERCISE
    ACTION:
    CRITERIA:
    0
    Q
    6
    0
    USE ATTENDANT CONSOLE AS AN ALTERNATE MASTER CONTROL TELEPHONEFOR DATA BASE 
    ADMINSTRATION AND MAINTENANCE TASKS.
    IDENTIFY FUNCTIONSAND APPLICATIOtiS OF PACKAGE C CMC MAINTENANCE
    COMMANDS.
    MODIFY PARAMETER VALUES FOR PACKAGE C CMC MAINTENANCE
    COMMANDS.
    USE ATTENDANT CONSOLE AND DATA INTERFACE UNIT DIAGNOSTIC TESTS TOIDENTIFY INSTRUMENT MALFUNCTIONS.
    COMPLETE REVIEW EXERCISE.
    TASKS WILL BE PERFORMED IN ACCORDANCE WITH PROCEDURES OUTLINEDIN 
    OMNI SBCS GTEP MANUAL AND OMNI SBCS STUDENT WORKBOOK.
    REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN ACCORDANCE WITHPASS/FAIL CRITERIA OF THIS TRAINING ORGANIZATION.0
    5.102 
    						
    							Attendee Assignment as Master
    e1 DESCRIPTION 1
    .
    A MAXIMUM OF TWO ATTENDANT CONSOLES CAN BE IDENTIFIED IN SYSTEM AS HAVING MASTER
    CONTROL TELEPHONE (MCT) CAPABILITIES FOR DATA BASE ADMINSTRATION AND
    MAINTENANCE ACTIVITIES..
    ATTENDANT CONSOLE FIRST MUST BE PLACED IN THE POSITION BUSY MODE TO FUNCTION AS
    AN MCT.
    1.ASSIGN OR CANCEL ATTENDANT CONSOLE DIRECTORY NUMBER
    AS MCT WITH CMC-702:.MCT NUMBER 
    (Pl) - (1 - 4)
    .
    DIRECTORY NUMBER OF MCT ATTENDANT CONSOLE (P2)
    (ATTENDANT CONSOLE ACCESS (0) + ATTENDANT CONSOLE
    NUMBER)
    NOTE: ATTEMPTS TO DELETE THE MCT BEING USED TO MAKE ENTRIES
    WILL BE DENIED BY DATA BASE.ICMC = 702
    Pl: 4
    P2: 015.103 
    						
    							Attehdent Console Operation as
    Master Control 
    ITelepPROCEDURE
    1.
    2.
    3.
    4.
    5.PLACE ATTENDANT CONSOLE IN POSITION BUSY MODE BY DEPRESSING THE POSITION BUSY FEATURE BUTTON. ANY
    CALLS IN PROCESS MUST BE CLEARED BEFORE POSITION BUSY MODE CAN BE ACTIVATED.
    ENTER APPROPRIATE HIGH OR LOW LEVEL SECURITY CODE USING KEYBOARD OF ATTENDANT CONSOLE
    (PREVIOUSLY ASSIGNED AS MCT) WHILE ON-HOOK AND IN IDLE STATE.
    AT COMMAND PROMPT, ENTER APPROPRIATE CMC COMMAND AND PRESS SELECT (ATTENDANT CONSOLE’S
    DEFAULT INCOMING FEATURE BUTTON).
    ENTER PARAMETER VALUES USING ATTENDANT CONSOLE‘S NUMERIC KEYPAD AND DESIGNATED PROGRAM
    FUNCTION BUTTONS (ILLUSTRAED ABOVE).
    PRESS RELEASE, THEN TERMINATE PROGRAM FUNCTION BUTTONS. PRESS POSITION BUSY FEATURE BUTTON TO
    RETURN TO NORMAL CALL PROCESSING MODE AS AN ATTENDANT CONSOLE.
    5.104 
    						
    							Student Notes
    5.105 
    						
    							Attendent Console
    Instrumentiagnostics
    .ATTENDANT CONSOLE MUST BE TESTED OFF-LINE.0THE FOLLOWING TESTS CAN BE PERFORMED:
    -BUTTON AND KEYPAD TEST
    - LED LAMP TEST
    - LCD DISPLAY TEST
    - AUDIBLE TONE TEST
    1.
    2.
    3.
    4.
    5.
    6.UNPLUG TELEPHONE CORD FROM MODULAR JACK IN BACK OF ATTENDANT CONSOLE.
    PRESS 1 and 3 KEYS SIMULTANEOUSLY.
    PLUG TELEPHONE CORD INTO MODULAR JACK WHILE KEEPING THE 1 AND 3 KEYS PRESSED.
    WHEN STEP 3 IS COMPLETED, PRESS ANY KEY TO ELIMINATE 
    lNlTlALSIGNAL(INDICATING INSTRUMENT IS
    IN DIAGNOSTIC MODE WITH ALL LED LAMPS FLASHING AND TONE RINGER SOUNDING).
    PRESS APPROPRIATE TEST EXECUTION KEYS (REFER TO TABLES ON FOLLOWING PAGES) AND MONITOR
    VISUAL AND AUDIBLE RESULTS. IF RESULTS VARY FROM THOSE LISTED, RETURN DEFECTIVE INSTRUMENT
    FOR REPAIR.
    TO RETURN TO NORMAL CALL PROCESSING MODE, REMOVE TELEPHONE CORD AND THEN REPLACE IN
    MODULAR JACK.
    5.106 
    						