    							MEMB (Enhanced Memory Card)POWERSUPPLY
    RGEN
    ICGO I1I2 I3 I4ICG51 swc CPM MEM PF,.
    MEMA (PACKAGE A/SVR 1.0.2.2) AND MEMB (PACKAGE B/SVR 1.5.X.X) BOTH INCLUDE:
    -ROM FOR OPERATING SYSTEM SOFTWARE AND DEFAULT STANDARD DATA BASE
    -RAM FOR CUSTOMlZED DATA BASE (ALSO RESIDES IN CPM CARD). MEMB (PACKAGE 
    B/SVR 1.5.X.X):
    -SUPPORTS PACKAGE B EQUIPMENT AND FEATURES
    -FUNCTIONS ONLY WITH CPMB CARD
    -CONTAINS MORE MEMORY THAN CPMA CARD:
    MEMAROM (IN BYTES) RAM (IN BYTES)
    64K0
    MEMB
    192K
    48K
    CPMAIMEMA256K96KCPMB/MEMB
    448K
    144K4.20 
    						
    							Review of Optional RGEN Card (Ring
    Generator) Package B Strapping OptionPOWERSUPPLY
    RGEN CARD IS lNSERTED IN MOUNTING SLOT LEFT OF CARD SLOT 00.
    GENERATES RINGING TONES FOR SINGLE LINE TELEPHONE INSTRUMENTS.
    SUPPLIES POWER TO MESSAGE WAITING FEATURE FOR SLT INSTRUMENTS EQUIPPED WITH
    MESSAGE WAITING LAMP (PACKAGE B).
    MESSAGE WAITING FEATURE FOR SLT IS ACTIVATED THROUGH A STRAPPING OPTION ON THE
    RGEN CARD. (STRAPPING OPTION INSTRUCTIONS ARE DESCRIBED IN SVR 
    1.5.X.X, INSTALLATION
    SECTION).
    RINGING:
    FREQUENCY:
    2f 2 Hz
    VOLTAGE:
    80 V RMS (NOMINAL)
    MESSAGE WAITING LAMP:
    VOLTAGE:
    -100 V DC
    ON/OFF INTERVAL:
    1 SECOND ON, 3 SECONDS OFF
    4.21 
    						
    							_,- -x,l
    8DTC Card (CSD Telephone/Data
    Terminal Interface Card)
    08DTC CARDS CAN BE INSERTED IN SLOTS 00 THROUGH 14 (IF CSD TELEPHONES EQUIPPED WITH
    DATA TERMINAL ADAPTER (DTA) ARE INSTALLED, ONLY SLOTS 
    00,03,06,09 AND 12 MAY BE
    USED)..
    SYSTEM CAPACITY OF FIVE 8DTC CARDS.
    @ 8DTC SPECIFICATIONS:
    -EIGHT CIRCUITS PER CARD (ONLY SIX IF CSD TELEPHONES ARE USED FOR DATA
    TRANSMISSION)
    -PROVIDES SIMULTANEOUS VOICE/DATA TRANSMISSION CONTROL DATA
    TRANSMISSION, CONTROL DATA TRANSMISSION, AND POWER FEEDING (-24V)
    OVER A SINGLE PAIR OF WIRES
    -SUPPORTS CSD DIGITAL TELEPHONES OR CSD TELEPHONES WITH DATA TERMINAL
    INTERFACES VIA DATA TERMINAL ADAPTER
    - 2000 FEET LOOP LIMIT
    -CHANNEL CAPACITY = 64 KBPS FOR VOICE AND DATA, 8 KBPS FOR TELEPHONE
    CONTROL
    -LINE BIT RATE = 384 KBPS
    4.22 
    						
    							CSD Digital TelephoneTEN PROGRAMMABLE FEATURE BUTTONS (TWO
    PREPROGRAMMED DATA COMMUNICATIONBUTTONS: 
    DATACALL AND VOICE/DATA MODE)
    FOUR FIXED FEATURE BUTTONS:
    SPEAKERPHONE, MUTE, TRANSFER, AND HOLD
    SPEAKERPHONE
    FOUR LINE, 20 CHARACTER LCD DISPLAY
    INTERFACE THROUGH 8DTC CARD
    LINE POWERED
    TWO WIRE:
    -2 DIGITAL TIP AND RING
    2,000 FEET LOOP LIMITMAY BE CONNECTED TO 
    BLFIDSS INSTRUMENT&m
    AS CONSOLE
    OPTIONAL DATA TERMINAL ADAPTER (DTA)
    INSTALLED WITHIN CSD PROVIDES RS-232-C
    INTERFACE TO CUSTOMER-SUPPLIED DATA
    TERMINAL.
    SYSTEM CAPACITY OF 40 CSD TELEPHONES
    (8 CIRCUITS X 5 CARDS) OR 30 CSD
    TELEPHONES WITH DATA INTERFACE (6
    CIRCUITS X 5 CARDS).
    4.23 
    						
    							,-..DTA Terminal
    Adapter (DTA),_--
    INSTALLED IN CSD TELEPHONES REQUIRINGDATA TERMINAL ADAPTER
    DATA APPLICATIONS
    SUPPORTS ASYNCHRONOUS/SYNCHRONOUS
    RS-232-C INTERFACE
    DATA SPEED = UP TO 19.2 KBPS
    CONNECTS TO CSD TELEPHONE USING ONE 64
    KBPSCHANNEL
    REAR OF CSD TELEPHONE EQUIPPED WITH DTA
    POWERED BY SEPARATE AC POWER SUPPLY
    ADAPTER 
    (9V DC)
    INTERFACES WITH 8DTC CARDS IN SLOTS 
    00,03,
    06, 09, OR 12.
    CUSTOMER-SUPPLIED DATA TERMINAL, WORK
    STATION, OR PRINTER CONNECTS TO DTA’S
    RS-232-C CONNECTOR LOCATED IN REAR OF
    CSD TELEPHONE).CONNECTOR
    TELEPHONE
    CORD
    NOTE:REFER TO PACKAGE B, INSTALLATION SECTION FOR INSTRUCTIONS FOR INSTALLING DTA IN
    CSD TELEPHONE.
    4.24 
    						
    							Data Terminal Station
    CUSTOMER-PROVIDED MICROCOMPUTER, WORK
    STATION, CRT TERMINAL, PRINTER, OR MODEM
    INTERFACES TO 
    OMNI SBCS VIA DTA IN CSD
    TELEPHONE
    DATA STATION DIRECTORY NUMBERING PLAN
    BEGINS WITH DIRECTORY NUMBER 350
    REQUIRES 25 PIN RS-232-C CONNECTOR CABLE
    (4,7, OR 12 PIN CABLE MAY BE USED DEPENDING
    ON SYSTEM APPLICATION)
    RS-232-C PIN CONFIGURATION MUST BE
    COMPATIBLE WITH PIN CONFIGURATION OF DTA
    IN CSD TELEPHONE
    SYSTEM ACCOMMODATES DATA TERMINALS
    WITH:
    -
    -
    -
    NOTE:ASYNCHRONOUS OR SYNCHRONOUS
    TRANSMISSION
    HALF OR FULL DUPLEX OPERATION
    DATA SPEED OF UP TO 19.2 KBPS
    REFER TO CSD USER’S GUIDE FOR DATA CALL OPERATING INSTRUCTIONS.
    4.25 
    						
    							Optional External Paging Amplifier
    Interface
    QPRQVIDES SYSTEM ACCESS TO CUSTOMER PROVlDED PAGING
    SPEAKER/AMPLIFIER.
    @ALLOWS FOR PAGING TO A MAXIMUM OF 9 PAGING ZONES.
    @INTERFACES WITH SYSTEM VIA A 4,BWC TRUNK CIRCUIT.
    4.26 
    						
    							view Exercise-SVR.l.S.X.X
    @=J)INSTRUCTIONS:THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL IN
    THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E., STUDENT
    WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO
    INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED.
    1.OMNI SBCS PACKAGE B DEVELOPMENT PHASE SVR.1.5.X.X) DIFFERS FROM THE LATER
    DEVELOPMENT PHASE BY PROVIDING BASICDATA COMMUNICATIONS
    ONLY.
    2.MATCH EACH OF THE FOLLOWING PACKAGE B FEATURES OR ENHANCEMENTS WITH ITS
    CORRECT DEFINITION:
    EQUAL ACCESS
    SIMULTANEOUS VOICE/DATA
    TRANSMISSION
    CALL SPLITTING
    MASTER CONTROL
    TELEPHONE
    BASIC DATA SWITCHING
    ENHANCED PAGING
    MESSAGE WAITING FOR
    SLT INSTRUMENTS
    a.
    b.
    C.
    d.
    e.
    f.
    9ACCESS TO EXTERNAL SPEAKER/AMPLIFIER
    ACTIVATES LAMP ON SLT TELEPHONES
    INTERNAL DATA COMMUNICATION BETWEEN 
    ON-SITE, LOW SPEED DATA TERMINALS
    CSD TELEPHONE FOR DATA BASE ADMINISTRATION
    AND MAINTENANCE TASKS
    VOICE AND DATA AT SAME TIME OVER CSD
    TELEPHONE’S SINGLE PAIR WIRING
    CAPABILITY OF TALKING TO EITHER CALLED OR
    CALLING PARTY WITHOUT HEARING THE OTHER’S
    CONVERSATION
    AUTOMATIC TRUNK CONNECTION TO CARRIER IN
    GEOGRAPHIC AREAS WHERE SERVICE IS AVAILABLE
    4.28 
    						
    							Review Exercise -SVR.1.5.X.X
    Overview (4.1) (Continued)
    3. 
    ~ASYNCHRONOUS TRANSMISSION IS:
    a. TWO-WAY SIMULTANEOUS TRANSMISSION
    b.TRANSMlSSiON WHERE THE SENDING DEVICE SIGNALS THE RECEIVING DEVICE BEFORE ITTRANSMITS EACH BYTE OF DATA
    c. TRANSMISSION ERROR CHECKING
    d.DATA TRANSMITTED IN A CONTINUOUSLY, VARYING SIGNAL
    4. (TRUE OR FALSE)
    DATA TERMINALS MUST BE 
    CdNNECTED TO A CSD TELEPHONE PROGRAMMED AS
    A MASTER CONTROL TELEPHONE.
    5.MATCH EACH OF THE FOLLOWING PACKAGE B DATA FEATURES WITH ITS CORRECT DEFINITION:
    DATA HOT LINE
    a.RELEASES A DATA CALL AUTOMATICALLY BY THE CALLING\STATION’S CALL RELEASE OPERATION
    AUTOMATIC DISCONNECT
    b.ALLOWS OR DENIES DATA TERMINAL STATIONS ACCESS TO
    SYSTEM DATA FEATURES BASED ON ASSIGNED LEVELS
    DATA TERMINAL GROUPc. ALLOWS A DATA TERMINAL STATION TO BE AUTOMATICALLY
    HUNTING
    CONNECTED TO ANOTHER PREDETERMINED DATA TERMINAL
    STATIONDATA CLASS OF SERVICE/
    CLASS OF RESTRICTIONd. ALLOWS A DATA CALL TO CALL AT AN IDLE STATION IN
    A DEFINED DATA TERMINAL STATION SELECTION GROUP AFTER IT
    ENCOUNTERS A BUSY SIGNAL
    6.THE PRIMARY ENHANCEMENT INCLUDED ON THE CPMB CARD IS ITS SUPPORT OF ALL
    EQUIPMENT AND FEATURES.
    7.(TRUE OR FALSE)-THE MEMBCARD FUNCTIONS ONLY WITH THE CPMB CARD AND CONTAINS
    MORE THAN TWICE THE MEMORY OF THE 
    MEMA CARD.
    4.29 
    						