AMP Connector Number Receptacles (1) (2) (3) (4) v 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 r I[ RGEN RGEN POWER SUPPLY AFTER CARDS HAVE BEEN INSTALLED, DETERMINE WHICH INTERFACE CARD 3: e &- c: --)i ‘-1 GROUP (ICG) WILL REQUIRE CABLES; ;, ‘,.a \$ &-’ ‘1 ’ PJ. ( .(‘-’ w”-i:L’,. , : ‘: ,I .. i ,:,I INSTALL M‘ALL! ENDED 25 PAIR AMP’CABiES TO CONNECTOR NhlBER 1-J-c * _.(2 :‘i ,. ( RECEPTACLES WHICH MATCH THE ICG QF THE INSTALLED CARDS. ENSURE THAT AMP CONNECTORS ARE SECURED FIRMLY TO THE AMP CONNECTOR NUMBER RECEPTACLES USING THE SCREWS PROVIDED. ATTACH THE CABLE TO THE WALL USING TIE WRAPS OR SIMILAR DEVICES TO PREVENT THE CONNECTOR FROM WORKING LOOSE. 1.52
Relationship of Card Slots and C Cables and AMP Connector Pins 1ST CARD SLOT ICG 0 ZND CARD SLOT 3RD CARD SLOT / \/ / CNO (AMP 0) CN 1 (AMP 1) 0 G !i is ICG-1 TROUGH THROUGH ICG 0 K z n ICG 5 PFT ALARMS SLOT 15 SLOT 36 SLOT 17 SLOT 18 72 a2 l.lL.l ’ 9b 1 5 10 15 20 25 uuYuu/YYu/YYu\/ CKTO NO I 2 3 o i 2 3 o I 2 3 CNlO 1 5 10 I 15 20 25 UUYU REMOTE ALARM MINOR RELAY REMOTE ALARM MAJOR RELAY 0 1 2 3 CNll 1.53 PFT . .
@ DIAGRAM REPRESENTS A TYPICAL EXAMPLE OF CROSS CONNECTIONS FOR A CS-10 OR CS-20 ELECTRONIC TELEPHONE. . EACH CS-10 AND CS-20 TELEPHONE WILL REQUIRE TWO PAIRS OF WIRES. ONE PAIR IS FOR TIP AND RING, THE OTHER FOR DATA/POWER. DATA PAIRS MUST BE INSTALLED PROPERLY FOR TELEPHONE TO WORK. BLF/DSS REQUIRES ONLY ONE PAIR OF WIRES (DATA/POWER) FOR OPERATION. e EXAMPLE ILLUSTRATES CDF CROSS CONNECTION FOR AN 8EKC INTERFACE CARD IN SLOT 01, USING CABLE NUMBER (CN) 1. CONNECTOR BLOCK SHOWN WOULD HANDLE THE LAST FOUR CIRCUITS FOR THE CARD SLOT IDENTIFIED ABOVE. . REFER TO CDF CROSS CONNECT REFERENCE CHART IN STUDENT WORKBOOK FOR CROSS CONNECTION INSTRUCTIONS FOR OTHER CARD AND EQUIPMENT CONFIGURATIONS. 25 PAIR CDF BLOCK CS-10 AND CS-20 TYPICAL CROSS
Single Line Telephone Installation DIAGRAM REPRESENTS A TYPICAL EXAMPLE OF CROSS CONNECTIONS FOR A SINGLE LINE TELEPHONE. EACH SINGLE LINE TELEPHONE REQUIRES ONLY ONE PAIR OF WIRES FOR TIP AND RING. ON THE CDF TERMINAL BLOCK, ONLY EVERY OTHER PAIR OF WIRES IS USED. EXAMPLE ILLUSTRATES CDF CROSS CONNECTION FOR AN 8SLC INTERFACE CARD IN SLOT 02, USING CABLE NUMBER (CN) 1. CONNECTOR BLOCK SHOWN WOULD HANDLE ALL EIGHT CIRCUITS FOR THE CARD SLOT IDENTIFIED ABOVE. REFER TO CDF CROSS CONNECT REFERENCE CHART IN STUDENT WORKBOOK FOR CROSS CONNECTION INSTRUCTIONS FOR OTHER CARD AND EQUIPMENT CONFIGURATIONS. POWER SUPPLY - LINE TELEPHONE
/’ _... CSD Telephone Installation @ DIAGRAM REPRESENTS A TYPICAL EXAMPLE OF CROSS CONNECTIONS FOR A CSD TELEPHONE. . EACH CSD TELEPHONE REQUIRES ONLY ONE PAIR OF WIRES FOR TIP AND RING (SIMILAR TO SLT CROSS CONNECTIONS). ON THE CDF TERMINAL BLOCK, ONLY EVERY OTHER PAIR OF WIRES IS USED. . EXAMPLE ILLUSTRATES CDF CROSS CONNECTION FOR AN 8DTC INTERFACE CARD IN SLOT 00, USING CABLE NUMBER (CN) 0. CONNECTOR BLOCK SHOWN WOULD HANDLE ALL EIGHT CIRCUITS FOR THE CARD SLOT IDENTIFIED ABOVE. . REFER TO CDF CROSS CONNECT REFERENCE CHART IN OF STUDENT WORKBOOK, INSTALLATION MODULE FOR CROSS CONNECTION INSTRUCTIONS FOR OTHER CARD AND EQUIPMENT CONFIGURATIONS. 25PAlR CDF BLOCK RING GREEN 1 RED MODULAR CABLE 25 PAIR CABLE TYPICAL CSD CROSS CONNECTION 1.56
CO Trunk Installatism @ DIAGRAM REPRESENTS A TYPICAL EXAMPLE OF CROSS CONNECTIONS FOR A CO TRUNK. @ EACH CO TRUNK FROM A 4BWC CARD REQUIRES 25PAlR CDF BLOCK ONLY ONE PAIR OF WIRES FOR TIP AND RING. EACH 1 :” - - I$ 4BWC CARD HAS FOUR CIRCUITS AND ON THE CDF TERMINAL BLOCK, ONLY EVERY OTHER PAIR OF WIRES IS USED. @ EXAMPLE ILLUSTRATES CDF CROSS CONNECTION FOR A 4BWC INTERFACE CARD IN SLOT 06, USING CABLE NUMBER (CN) 4. CONNECTOR BLOCK SHOWN WOULD HANDLE ALL FOUR CIRCUITS FOR THE CARD SLOT IDENTIFIED ABOVE, USING 26/l, 28/3,30/5, AND 3217 FOR EACH CIRCUIT. @ REFER TO CDF CROSS CONNECT REFERENCE CHART IN STUDENT WORKBOOK FOR CROSS CONNECTION INSTRUCTIONS FOR OTHER CARD AND EQUIPMENT CONFIGURATIONS. - POWER SUPPLY L MEEN RED ‘I 1.57
Loop Tie Trunk Installation DIAGRAM REPRESENTS A TYPICAL EXAMPLE OF CROSS CONNECTIONS FOR A LOOP TIE TRUNK. EACH LOOP TIE TRUNK FROM A 2TTL CARD REQUIRES ONLY ONE PAIR OF WIRES FOR TIP AND RING. EACH 2TTL CARD HAS TWO CIRCUITS. EXAMPLE ILLUSTRATES CDF CROSS CONNECTION FOR A 2TTL INTERFACE CARD IN SLOT 08, USING CABLE NUMBER (CN) 5. CONNECTOR BLOCK SHOWN WOULD HANDLE BOTH CIRCUITS FOR THE CARD SLOT IDENTIFIED ABOVE, USING PINS 34/9 FOR THE FIRST CIRCUIT AND 36/I 1 FOR THE SECOND CIRCUIT. REFER TO CDF CROSS CONNECT REFERENCE CHART IN STUDENT WORKBOOK FOR CROSS CONNECTION INSTRUCTIONS FOR OTHER CARD AND EQUIPMENT CO’ FIGURATIONS. I 25 PAIR CDF BLOCK 48- - 23 - _ 49 - - 24 - - 50 - - 25 - - L 1.58 la 111 IRUlKS
e DIAGRAM REPRESENTS A TYPICAL EXAMPLE OF CROSS CONNECTIONS FOR A E&M (TYPE I) TIE TRUNK. 0 EACH TYPE I E&M TRUNK FROM A PTTE CARD REQUIRES TWO PAIR OF WIRES. ONE PAIR FOR TIP AND RING, THE OTHER PAIR FOR E (RECEIVE) AND M (TRANSMIT). EACH PTTE CARD HAS TWO CIRCUITS. . EXAMPLE ILLUSTRATES CDF CROSS CONNECTION FOR A 2TTE INTERFACE CARD IN SLOT 08, USING CABLE NUMBER (CN) 5. CONNECTOR BLOCK SHOWN WOULD HANDLE BOTH CIRCUITS FOR THE CARD SLOT IDENTIFIED ABOVE, USING PINS 34/9,35/10 FOR THE FIRST CIRCUIT AND 38/13, 39/14 iOR THE SECOND CIRCUIT. . REFER TO CDF CROSS CONNECT REFERENCE CHART IN STUDENT WORKBOOK FOR CROSS CONNECTION INSTRUCTIONS FOR OTHER CARD AND EQUIPMENT CONFIGURATIONS. I[ RGEN RGEN ,O 0, 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 I! ~~~~~~~ 25 PAIR CDF BLOCK 1IP - Rlmi Y --A-.-
M (Type II) Tie Trunk Installation DIAGRAM REPRESENTS A TYPICAL EXAMPLE OF CROSS CONNECTIONS FOR A E&M (TYPE II) TIE TRUNK. EACH TYPE II E&M TRUNK FROM A 2TTE CARD REQUIRES THREE PAIR OF WIRES. ONE PAIR FOR TIP AND RING, THE OTHER FOUR WIRES FOR SIGNAL GROUND, E (RECEIVE), M (TRANSMIT), AND SIGNAL BATTERY. EACH 2TTE CARD HAS TWO CIRCUITS. EXAMPLE ILLUSTRATES CDF CROSS CONNECTION FOR A 2TTE INTERFACE CARD IN SLOT 06, USING CABLE NUMBER (CN) 4. CONNECTOR BLOCK SHOWN WOULD HANDLE BOTH CIRCUITS FOR THE CARD SLOT IDENTIFIED ABOVE, USING PINS 26/l, 28/3, 29/4 FOR THE FIRST CIRCUIT AND 30/5,32/7, AND 3318 FOR THE SECOND CIRCUIT. REFER TO CDF CROSS CONNECT REFERENCE CHART IN STUDENT WORKBOOK FOR CROSS CONNECTION INSTRUCTIONS FOR OTHER CARD AND EQUIPMENT CONFIGURATIONS. 25PAlR CDF BLOCK 1.60
ass Connect ce; rt CAAO SLOT CABLE CIRCUIT AMP COFCABLE BSLC BEKC BBTC 48WC 2TTE 2TrE NUMBER NUMBER CONN COLOR (TYPE I) (TYPE II) PTTL NOTES: 0 26 WHT-BLU TIP 0 TIP 0 TIP 0 TIP 0 TIP 0 TIP 0 TIP 0 1 sLwT RING 0 RlNS 0 RING 0 RING 0 AINS 0 RING 0 RlNS 0 . BSLC. BEKC. AN0 80TC CAROS 21 WHT-SRN SAIA M CANNOT BE INSERTEO IN SLOTS 2 ORNWHT OAIA E 15.18. II. AN0 I* TIP I SIN6 1 2 0 IO 36 II BLU-ELK 37 ELK-DAN 12 ORN-SLK 18 44 19 45 TIP 2 “INS 2 OAIA OAIA TIP 2 RING 2 TIP 2 RING 2 TIP I RING I M F ORN-REO REO-8RN BAN-NED RELTSL SL-RED SLK.BLU BLK.SRN GAN4LK BLK-BRN BRN-ELK BKSL SL-SLK “EL-W KU-“EL YEL.ORN ORN-YEL “EL-SRN !&IN-“EL YEL-BHN URN-YE1 YEL.SL SL.YEL YIO4LU mJ4I0 WORN ORN4,O TIP 4 RING 4 TIP 5 RING 5 TIP 6 RING 6 TIP 7 RING I TIP 0 FUNS 0 TIP , RINS 1 TIP 2 RING 2 RING 4 DATA OATA TIP 5 RING 5 SATA OATA TIP 6 AINS 6 OAIR OATR TIP 7 RING I DATA OATA TIP 0 RING 0 SATA OAIA TIP I RING I OATA OAIA TIP 2 RING 2 DATA DATA TIP 3 TIP 4 RING 4 TIP 5 AING 5 TIP 6 RING 6 TIP 7 NlNS I TIP 0 RING 0 TIP 1 RING 1 TIP 2 RING 2 TIP 3 TIP 0 RING 0 M E TIP I NINS I M TIP 0 TIP 0 ION6 0 RING 0 E M 88 TIP I RING I ss . *OTC ONLY CAN BE INSERTED IN SLOTS 00 03.06.09. AN0 12 WHEN “SE0 FOR “OICEIOATA IOTA OPTION, . 48WC. 2TTE. AN0 2TTL CANNOT BE INSERIEO IN SLOTS 00. 01.0*.03.04. on 05 TIP 1 AIN 1 1.61