    							Hotel/Motel PrinterInstdlation (Continued)
    HOTEL/MOTEL PRINTER AND 
    DlU/DTA RS-232-C
    PIN CONFIGURATION
    H/M PRINTER
    DIU/DTA
    FG
    TXD
    RXD
    RTS
    CTS
    DSR
    SG
    RLSD
    DTR25 PIN
    1
    2
    3
    4
    5
    6
    7
    8
    20
    1
    2
    3
    4
    5
    6
    7
    8
    20
    5.56
    FG
    TXD
    RXD
    RTS
    CTS
    DSR
    SG
    RLSD
    DTR25 PIN 
    						
    							Laboratory Activity -
    Package C Installation; (5.2)
    1.
    2.
    3.
    4.
    5.
    6.
    7.
    6.
    9.POWER SYSTEM OFF.
    ENSURE THAT PROPER ELECTROSTATIC GROUND PROCEDURES ARE FOLLOWED PRIOR TO
    HANDLNG PCB CARDS.
    BEGIN REPLACING AND INSTALLING THE DESIGNATED PRINTED CIRCUIT BOARDS IN CARD
    SLOTS IDENTIFIED BELOW. ENSURE THAT CARD COMPONENTS ARE ON LEFT SIDE OF THE
    BOARDS.
    (A)INSERT AND SEAT A CHARACTER TRUNK CARD (4CHT) IN CARD SLOT 14.
    (B)REPLACE THE CPMB CARD IN SLOT 20 WITH THE PACKAGE C ENHANCED
    CONTROL PROCESSOR MEMORY CARD (CPMC).
    (C)REPLACE THE MEMB CARD IN SLOT 21 WITH THE PACKAGE C ENHANCED
    MEMORY CARD (MEMC).
    REMOVE THE CS-20 PREVIOUSLY WIRED TO CARD SLOT 01, CIRCUIT 4 (FORMERLY
    DIRECTORY NUMBER 212). REPLACE THE INSTRUMENT WITH AN ATTENDANT CONSOLE
    INSTRUMENT.
    REMOVE THE BLF/DSS MODULE PREVIOUSLY WIRED TO CARD SLOT 01, CIRCUIT 5. REPLACE
    THE MODULE WITH AN ATTENDANT CONSOLE BLF/DSS MODULE WHICH WILL BE USED FOR
    ROOM STATUS INDICATION.
    WIRE CROSS CONNECTION AND INSTALL A DATA INTERFACE UNIT (WITH ATTACHED
    PRINTER) TO CARD SLOT 00, CIRCUIT 2. DEFAULT DIRECTORY NUMBER WILL BE 202.
    POWER SYSTEM ON AND COLD RESTART SYSTEM BY PRESSING RESTART BUTTON ON CPMC
    CARD WITH TOGGLE SWITCH IN UPPER POSITION.
    REPROGRAM THE ODDB.
    TEST OPERATION OF PACKAGE C PERIPHERALS.
    5.57 
    						
    							Review Exercise -Package C Installation 
    (5.2)
    INSTRUCTIONS:
    THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL IN THE
    BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E., STUDENT WORKBOOK,
    NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO INSTRUCTOR FOR
    GRADING WHEN LAST QUESTION HAS BEEN COMPLETED.
    1.
    2.
    3.
    4.
    5.
    6.(TRUE OR FALSE) THE 6PFE CARD CAN PROVIDE POWER FAILURE TRANSFER INTERFACES
    FOR THE STANDARD OR EXPANDED SYSTEMS, IF INSTALLED IN SLOT 22 OF BOTH 
    BASIC OR
    EXPANSION CABINETS.
    IF THE 
    6PFE CARD IS USED IN THE EXPANSION CABINET, THE CARD’S
    MUST BE SET IN EXPANSION MODE.
    EACH DATA INTERFACE UNIT (DIU) REQUIRES INSTALLATION OF
    PAIR OF WIRES ON THE
    TERMINAL BLOCK.
    DATA INTERFACE UNITS USED WITH MODEMS MUST BE IN
    MODE TO
    COMMUNICATE VIA THE RS-232-C CABLE.
    HOW CAN AN ATTENDANT CONSOLE BE INSTALLED TO ACCOMMODATE DISTANCES GREATER THAN
    300 FEET FROM THE SYSTEM CABINET?
    INSTALLATION OF EXPANSION CABINET REQUIRES CONNECTION OF AN INTERMODULE CABLE FROM
    THE
    CARD IN THE BASIC CABINET TO THE
    CARD IN THE EXPANSION CABINET.
    5.58 
    						
    							Review Exercise -
    Package YicInstallation (5.2) (Continued).. .
    7.
    8.
    9.
    10.(TRUE OR FALSE)THE HOTEL/MOTEL PRINTER IS CONNECTED DIRECTLY TO THE
    SYSTEM VIA A TWO-WIRE INTERFACE TO A CIRCUIT ON THE 4CHT CARD.
    INSTALLATION OF POWER TRANSFER FOR THE EXPANDED SYSTEM REQUIRES CROSS
    CONNECTIONS FOR THE
    , AND, SIGNAL
    LEADS ON THE 
    6PFT AND 6PFE CARDS.
    AN ATTENDANT CONSOLE CROSS CONNECTED TO CIRCUIT 4 OF AN 8EKC CARD INSTALLED IN
    SLOT 01 WOULD USE PINS
    , AND
    , ON THE
    CDF TERMINAL BLOCK.
    A DATA INTERFACE UNIT CROSS CONNECTED TO CIRCUIT 2 OF AN 
    8DTC CARD INSTALLED IN
    SLOT 00 WOULD USE PINSAND
    ON THE CDF TERMINAL BLOCK.
    5.59 
    						
    							Student Notes5.60 
    						
    							PACKAGE C
    Data Base Administration
    5.61 
    						
    							5.3 Enabling ObjectiveGIVEN:0
    0
    0
    0
    l
    ACTION:0
    a
    0CRITERIA: .
    0
    GTE OMNI SBCSGTE OMNI SBCS PACKAGE C EQUIPMENT AND
    PERIPHERALSPROGRAMMING DEVICE (PMP OR MCT)
    OMNI SBCS COURSE AND SITE DOCUMENTATION
    PACKAGE
    REVIEW EXERCISEIDENTIFY FUNCTIONS AND APPLICATIONS OF PACKAGE
    C CMC COMMANDS.
    PERFORM SYSTEM PROGRAMMING TASKS RELATED TO
    ATTENDANT CONSOLE, HOTEL/MOTEL, KEY SYSTEM, AND
    DID/DISA APPLICATIONS.
    COMPLETE REVIEW EXERCISE.DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE
    WITH PROCEDURES OUTLINED IN OMNI SBCS GTEP
    MANUAL AND 
    OMNI SBCS STUDENT WORKBOOK.
    REVIEW EXERCISE WILL BE COMPLETED CORRECTLY INACCORDANCE WITH PASS/FAIL CRITERIA OF THIS
    TRAINING ORGANIZATION.
    5.62 
    						
    							Programming Attendant Console
    .ATTENDANT CONSOLE PROVIDES A VARIETY OF FEATURES ALLOWING FOR ANSWERING,
    TRANSFERRING, AND PROCESSING OF CALLS USING FIXED AND PROGRAMMABLE FEATURE
    BUTTONS AND ACCESS CODES..
    TWO ADD ON MODULES ARE AVAILABLE TO SUPPLEMENT THE OPERATION OF THE ATTENDANT
    CONSOLE: A BUSY LAMP FIELD/DIRECT STATION SELECTION 
    (BLFIDSS) MODULE AND A ROOM
    STATUS INDICATOR MODULE.
    1.IDENTIFY CIRCUIT PORT ON 8EKC CARD TO BE USED FOR CONNECTION. (IF ATTENDANT
    CONSOLE IS TO BE PLACED MORE THAN 300 FEET FROM SYSTEM CABINET, A SECOND DATA
    PAIR WILL BE REQUIRED.)2. INSTALL ATTENDANT CONSOLE.
    3.ASSIGN ATTENDANT CONSOLE WITH CMC-230:.ATTENDANT CONSOLE (PI) 
    - (1 OR 2)
    e EQUIPMENT NUMBER (P2)
    .
    TENANT NUMBER (P3) - (1 - 4).
    ATTENDANT CONSOLE NUMBER FOR COPY (P4)CMC= 230
    Pl:P4:
    P2: 010
    P3:
    NOTE:
    THE ATTENDANT CONSOLE CAN BE INSTALLED OR REMOVED ONLY IN AN OFF LINE
    (POSITION BUSY) STATE. ATTENDANT CONSOLE CAN BE REMOVED ONLY IF BLF/DSS IS
    ATTACHED.
    5.63 
    						
    							Programming Attendant
    Console (Continue1 PROCEDURE 1(Continued)
    4.ASSIGN ATTENDANT CONSOLE SERVICES TO FEATURE BUTTONS
    WITH CMC-231:.
    ATTENDANT CONSOLE NUMBER (PI) - (1 OR 2).
    BUTTON NUMBER (P2) - (1 - 16).
    FEATURE NUMBER (P3) - (1 - 255). SUPPLEMENTARY DATA (P4)
    5.ASSIGN ATTENDANT CONSOLE CLASS OF SERVICE (COS) AND CLASS
    OF RESTRICTION (COR) ASSIGNMENT WITH CMC-232:.
    ATTENDANT CONSOLE NUMBER (PI) - (1 OR 2)
    *CLASS OF SERVICE - DAY MODE (P2) - (1 - 16)
    0CLASS OF SERVICE - NIGHT MODE (83) - (1 -1 6)
    0CLASS OF RESTRICTION - DAY MODE (P4) - (1 - 16)
    .CLASS OF RESTRICTION-NIGHT MODE (P5) 
    - (1 - 16)
    6.ASSIGN ATTENDANT CONSOLE PRIORITY FOR INCOMING CALL
    TERMINATION WITH CMC-233:.TRUNK GROUP NUMBER (PI) 
    - (1 - 63)
    .
    ANSWER PRIORITY (P2) - (1 = HIGH to 3 = LOW)
    CMC= 231
    Pl: 1P4:
    P2: 1
    P3: 50CMC= 232
    P3: 16CMC= 233
    Pl: 13
    P2: 1
    5.64 
    						
    							Programming Attendant
    Console (Continued)(PROCEDUREI (Continued)
    7.CREATE NIGHT ANSWER GROUP FOR ATTENDANT CONSOLE
    OVERFLOW STATION WITH CMC-306:.NIGHT ANSWER GROUP NUMBER (PI) 
    - (1 - 32)
    .
    TRUNK/STATION TENANT FLAG (P2) - (1 = STATION,
    2 = TRUNK; 3 = TENANT)
    @EQUIPMENT NUMBER (P3) - (STATION TO RECEIVE OVERFLOW CALLS)
    8.ASSIGN “ALL TENANTS” TO ATTENDANT CONSOLE OVERFLOW
    NIGHT ANSWER GROUP (ASSIGNED ABOVE) WITH CMC-306:
    0NIGHT ANSWER GROUP NUMBER (PI).
    TRUNK/STATION TENANT (P2) - (1 = STATION,
    2 = TRUNK, 3 = TENANT).
    EQUIPMENT NUMBER (P3) - (ASSIGN“*” TO INDICATE ALL TENANTS)
    5.65CMC= 306
    Pl: 1
    P2: 1
    P3: 016CMC= 306
    Pl: 1
    P2: 3
    P3: *
    ..
    /’ 
    						