    l SBCS CAN FUNCTION AS A STANDALONE COMMUNICATION SYSTEM OR AS A FRONT-END SYSTEM BEHIND 
    OTHER SWITCHING EQUIPMENT, SUCH AS A PABX. 
    . SOME SYSTEM PARAMETER VALUES MAY REQUIRE RESETTING TO ACCOMMODATE CONFIGURATIONS 
    POSSIBLE WITH A FRONT-END ARRANGEMENT. 
    REFER TO CMC-100 TO COORDINATE FEATURE ACCESS NUMBERING PLANS FOR BOTH SYSTEMS AND 
    CMC-200 TO COORDINATE STATION NUMBERING PLANS. 
    1. USE CMC-250 TO MODIFY TRUNK ASSIGNMENT DATA: 
    . EQUIPMENT NUMBER (Pl) CMC = 250 
    . TYPE OF TRUNK (P2) Pl: 182 P4: 3 
    . TRUNK GROUP NUMBER (P3) 
    cl P2: 6 P5: 1 
    . OPERATION MODE (P4) P3: 13 
    P6: 1 
    . SIGNALING (P5) 
    . START MODE/ZONE NUMBER (P6) 
    2. USE CMC-254 TO MODIFY TRUNK ROUTE TIMING SO THAT SBCS FLASH TIMING VALUE MATCHES HOST 
    PABX: 
    . TRUNK GROUP NUMBER (Pl) 
    . ROUTE TIMING IDENTIFICATION NUMBER (P2) 
    0 NORMALIZED TIMING (P3) 
    3. USE CMC-400 TO MODIFY TRUNK DIALING GROUP NUMBERS AND RESTRICTION GROUP ASSIGNMENTS: 
    0 TRUNK GROUP NUMBER (Pl) 
    @ DIAL GROUP NUMBERS (P2 = BLANK) 
    0 TOLL RESTRICTION GROUP NUMBER (P3 = BLANK) CMC = 400 
    P-l: 13 
    P2: 
    P3: 
    2.196  
    						
    							DESCRlPTlOii 
    . ALLOWS SBCS TO BE SHARED BY AS MANY AS FIVE TENANTS. TENANTS MAY USE 
    OWN STATIONS AND/OR TRUNKS, BUT SHARE COMMON CONTROL LOGIC, POWER 
    SUPPLY, ATTENDANT CONSOLE, AND SERVICE TRUNKS. 
    . STATIONS AND TRUNKS (EXCEPT TIE TRUNKS) ARE ASSIGNED TO TENANT 
    NUMBERS SO EACH TENANT CAN ACCESS OWN TRUNKS. TENANTS SHARE SAME 
    FEATURE ACCESS CODE AND STATION NUMBERING PLAN. 
    . THREE TYPES OF TENANT TRUNK SHARING DESIGNATIONS ARE AVAILABLE: 
    - OUTGOING/INCOMING TENANT (NO TRUNK SHARING WITH OTHER 
    TENANTS) 
    - OUTGOING ONLY TENANT (SHARING INCOMING TRUNKS WITH 
    OTHER TENANTS) 
    - INCOMING ONLY TENANT (SHARING OUTGOING TRUNKS WITH OTHER 
    TENANTS) 
    0 STATION MESSAGE DETAIL RECORDING (SMDR) OUTPUT CAN BE RECORDED BY 
    TENANT NUMBERS. FIFTH TENANT IS INDICATED BY CORRESPONDING “BLANK” 
    OUTPUT FOR TENANT NUMBER REFERENCE. 
    2.197  
    						
    							pitEKE- 
    I. USE CMC-20-l TO ASSlGN TENANT NUMBERS TO STATIONS: 
    Q STATION DIRECTORY NUMBER (PI) 
    8 OPERATION MODE (P2) 
    . TYPE OF DIALING (P3) 
    8 TENANT NUMBER (P4) CMC = 201 
    Pl: 236 P4: 2 
    cl 
    P2: 1 P5: 
    P3: 3 
    @ METERING GROUP NUMBER FOR SMDR (P5) 
    2. IF APPLICABLE, USE CMC-102 TO SELECT: 
    . FLAG NUMBER (PI) 
    @ SET VALUE (P2) 
    3. USE CMC-251 TO ASSIGN TENANT NUMBERS TO TRUNKS: 
    @ EQUIPMENT NUMBER (PI) 
    Pl: 161 P4: 3 
    . DIAL MODE/BREAK RATIO (P2) 
    @ TRUNK DIRECTORY NUMBER (P3) 
    If ‘I  e TENANT NUMBER (P4) 
    4. USE CMC-503 TO ASSIGN SMDR OUTPUT FOR TENANTS: 
    . TENANT NUMBER (PI) 
    . OUTPUT IDENTIFICATION FLAG (P2) 
    CMC = 503 
    Pl: 2 
    P2: 1 
    II 
    2.198  
    						
    							Programming Speci 
    System Configurations/ 
    Off-Premises Extension (OPX) 
    I I 
    . ALLOW CONNECTION TO THE SBCS SYSTEM OF SINGLE-LINE TELEPHONE INSTRUMENTS LOCATED AT OFF-PREMISES 
    LOCATION. 
    . CUSTOMER PROVIDED LOOP EXTENDER MUST BE INSTALLED TO EXTEND STATION LINES AND TO PROTECT PUBLIC 
    SWITCHED NETWORK, IF THE IMPEDANCE OF THE PHONE EXCEEDS THE LOOP LIMIT OF THE SYSTEM. 
    . OFF PREMISES EXTENSION (OPX) EQUIPMENT IS MOUNTED AND POWERED EXTERNALLY TO OMNI SBCS CABINET. 
    . RINGING PATTERN FOR OPX STATIONS IS FIXED AND DEFAULT PATTERN IS STATION RINGING PATTERN. 
    CMC = 200 
    1. USE CMC-200 TO ASSIGN OPX EQUIPMENT NUMBER TO STATION 
    DIRECTORY NUMBER. 
    . EQUIPMENT NUMBER (PI) 
    r-l 
    Pl: 015 P4: 
    P2: 346 
    P3: 1 
    . DIRECTORY NUMBER (P2) 
    . TYPE OF TERMINAL (P3) 
    . COPIED STATION DIRECTORY NUMBER (P4) 
    2. USE CMC-204 TO IDENTIFY DIRECTORY NUMBER AS OPX EXTENSION: 
    Pl: 346 P4: 0 
    . STATION NUMBER (Pl) 
    . DATA SECURE (P2) 
    . OFF-PREMISES EXTENSION (P3) 
    . SLT WITH MESSAGE WAITING LAMP (P4) 
    3. USE CMC-102 TO CHANGE RINGING PATTERN: CM6 = 102 
    0 FLAG NUMBER (Pl) - (FLAGS 2 AND 9) 
    rl Pl: 2 
    . SET VALUE (P2) P2: 2 
    * ASSUMES INSTALLATION OF SINGLE-LINE TELEPHONE INSTRUMENT AND LOOP EXTENDER AND PHYSICAL 
    CONNECTION OF OPX LINE TO DESIRED CIRCUIT ON 8SLC CARD. 
    2.199  
    						
    							e SBCS BEHIND A PAl3X CMC-250 
    CMC-254 
    CMC-400 
    e 
    TENANT ASSIGNMENT CMC-201 
    CMC-251 
    CMC-503 
    8 
    OFF-PREMISE EXTENSION CMC-200 
    CMC-204 
    CMC-102 MODIFY TRUNK ASSIGNMENT DATA 
    MODIFY TRUNK ROUTE TIMING ASSIGNMENT 
    MODIFY TRUNK DIALING ASSIGNMENT 
    ASSIGN TENANT NUMBERS TO STATIONS 
    ASSIGN TENANT NUMBERS TO TRUNKS 
    ASSIGN SMDR OUTPUT FOR TENANTS 
    ASSIGN OPX EQUIPMENT NUMBER TO STATION 
    DIRECTORY NUMBER 
    IDENTIFY DIRECTORY NUMBER AS OPX EXTENSION 
    CHANGE RINGING PATTERN FOR OPX FIXED 
    RINGING 
    2.200  
    						
    							PERFORM THE FOLLOWING PROGRAMMING TASKS IN THE SEQUENCE OUTLINED BELOW USING THE 
    SAMPLE WORK ORDERS AND IN ACCORDANCE WlTH THE GTE OMNll SBCS GTEP MANUAL. COMPLETE 
    THE REVIEW EXERClSE QUESTlONS PERTAINING TO SPECIAL SYSTEM CONFIGURATIONS UPON 
    COMPLETION OF THIS LABORATORY ACTIVITY. 
    WORK ORDER 
    #2.11 
    :OMPANY NAME: NU SYSTEM CO. 
    PHONE #: (703) 5551212 
    .OCATION: 
    RESTON, VIRGINIA WORK ORDER #2.11 (TASK #l) 
    )RfGfNATCR: TELECOMMUNICATIONS MANAGER 
    ‘ASKS: 
    s Perform necessary system modifications required to program OMNI SBCS 
    behind a host PABX with CMC-100, CMC-254, CMC-400, and CMC-300. 
    (1) Modify the OMNI SBCS flash timing value to (1) Verify that there are no numbering conflicts in 
    500 seconds using CMC-254. Change P3 to feature access for the OMNI SBCS or the host 
    value of 5. PABX, using CMC-100. Examine station 
    (2) Change the trunk dialing group and restriction numbering plan for conflicts and make appro- 
    group numbers with CMC-400. Ensure that P2 priate changes with CMC-200. 
    and P3 are blank. (2) Perform programming changes for special 
    (3) Change any system speed calling directory system configuration. 
    numbers with CMC-300 to conform to host (3) Check/test the operation of changes afler 
    system. Ensure that access code (P2) is 9 and completion of this portion of the laboratory 
    send number (P3) begins with 9#. 
    (4) Proceed to next work order task. 
    2.202  
    						
    							Laboratory Activity - Programming 
    WORK ORDER #2.11 
    :OMPANY NAME: NU SYSTEM CO. 
    PHONE #: (703) 5551212 
    .OCAT’ON: RESTON, VIRGINIA WORK ORDER H.11 (TASK #2) 
    )R’G’NAToR: TELECOMMUNICATIONS MANAGER 
    .ASKS: 
    e Assign tenant assignments with CMC-201, CMC-102, and CMC-251. 
    (1) Assign stations to tenant numbers with CMC- (1) Perform programming changes for special 
    201 using the following groups: system configuration. 
    Station DN Tenant Group (2) Check/test the operation of changes after 
    completion of this portion of the laboratory 
    212 
    214 (3) Proceed to next work order task. 
    216 
    (2) Select “own trunk for outgoing - share 
    incoming trunks” option with CMC-102. 
    (3) Assign trunk equipment number to tenant 
    group 1 and trunk equipment number to tenant 
    group 2 with CMC-251. 
    ups 1 and 2 will require output with 
    2.203  
    						
    							WORK ORDER #2.11 
    :OMPANY NAME: NU SYSTEM CO. PHONE #: (703) 5551212 
    OCATION: RESTON, VIRGINIA 
    WORK ORDER #2.11 (TASK #3) 
    ‘RlGtNATCR: TELECOMMUNICATIONS MANAGER 
    ASKS: 
    --- l Perform programming required for single line station designated-as off-premises extension 
    with CMC-200, CMC-204, and CMC-102. 
    OPX equipment number 027 has (1) Ensure that off-premises SLT instrument and 
    gned to the SLT instrument (directory customer provided loop extender are 
    physically installed. 
    NOTE: Above verification is not required for 
    (2) Identify above station as OPX station using 
    this lab activity since lab activity simulates OPX 
    CMC-204 (P3). 
    installation and actually uses an on-site SLT. 
    (3) Change ringing pattern for OPX station using 
    (2) 
    CMC-102 (P2, flag 2) from station call ringing Perform programming changes for special 
    (default) to incoming call ringing. system configuration. 
    (3) Check/test the operation of changes afler 
    completion of this portion of the laboratory 
    - 
    LAB MILESTONE: 
    I 
    . VERIFY THAT ALL PROGRAMMING CHANGES REQUESTED IN WORK ORDERS HAVE 
    BEEN PERFORMED CORRECTLY. 
    I 
    . ASK INSTRUCTOR TO INSPECT SPECIAL SYSTEM CONFIGURATIONS PROGRAMMING 
    AND INITIAL YOUR PERFORMANCE CHECKLIST. 
    I . MAKE CERTAIN QUESTIONS l-10 OF REVIEW EXERCISE 2.11 HAVE BEEN 
    COMPLETED BEFORE SUBMITTING TO THE INSTRUCTOR FOR GRADING. 
    I 
    2.204  
    						
    							Review Exercise - 53 
    INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL 
    IN THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E. STUDENT 
    WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO 
    INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 
    1. EXPLAIN WHY IT IS NECESSARY TO EXAMINE TABLES FOR CMC-100 AND CMC-200 WHEN 
    INSTALLING AN OMNI SBCS BEHIND A PABX. 
    2. HOW WOULD YOU INCREASE THE OMNI SBCS FLASH TIMING VALUE WITH CMC-254? 
    3. WHY WOULD YOU LEAVE THE PARAMETERS FOR TRUNK DIAL GROUP NUMBER AND TOLL 
    RESTRICTION GROUP BLANK WHEN MODIFYING CMC-400 TO ALLOW FOR THE OMNI SBCS 
    BEHIND A PABX? 
    2.205  
    						