Review Exercise - Savim and ading the Office Depeident Base (2,12) (Continued) 8. THE SYSTEM AUTOMATICALLY INITIATES A FOLLOWING THE LOADING OF THE ODDB TAPE. 9. IF THE ODDB TAPE VOLUME SERIAL NUMBER IS NOT CORRECT, THE PMP SCREEN WILL DISPLAY: 10. WHAT IS INDICATED IF THE MESSAGE “BAD TAPE/SF VER,XXX” IS DISPLAYED ON THE PMP SCREEN? 11. WHAT ADDITIONAL EQUIPMENT IS REQUIRED TO SAVE AND LOAD THE ODDB USING A FLOPPY DISKETTE? 12. WHAT PROCEDURE MUST BE PERFORMED BEFORE A NEW FLOPPY DISKETTE MAY BE USED? 13. THE OMNI SBCS REQUIRES FLOPPY DISKETTES TO STORE A COMPLETE ODDB. 14. ((TRUE OR FALSE): SAVING AND LOADING THE ODDB WITH THE DISKETTE DRIVE (WHEN USING SVR 1.5.X.X) REQUIRES DIFFERENT CMC COMMANDS THAN THE TAPE BACK-UPS. 2.226
Review Exercise - Saw& and Loading the Office D ase (2.112) (Con 15. MATCH EACH OF THE FOLLOWING CMC COMMANDS WITH ITS CORRECT DEFINITION: CMC-902 A. LOAD ODDB TO SYSTEM MEMORY FROM TAPE OR FLOPPY DISKETTE. CMC-903 B. SAVE ODDB FROM SYSTEM MEMORY TO TAPE OR FLOPPY DISKETTE. 2.227
2.13 Enablinq Obiective GIVEN 0 0 0 0 0 0 ACTION: . CRITERIA: . 0 GTE OMNI SBCS GTE OMNI SBCS PERIPHERALS PORTABLE MAINTENANCE PANEL GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE LABORATORY ACTIVITY-COMPLETING AND USING OMNI SBCS IMPLE- MENTATION FORMS PACKAGE REVIEW EXERCISE INTERPRET AND USE OMNI SBCS IMPLEMENTATION FORMS PACKAGE AS ESSENTIAL TOOL FOR SYSTEM CONFIGURATION AND DATA BASE ADMINISTRATION. COMPLETE REVIEW EXERCISE DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE WITH PRO- CEDURES OUTLINED IN OMNI SBCS GTEP MANUAL AND OMNI SBCS STUDENT WORKBOOK. REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING ORGANIZATION. 2.229
Laboratory Actiwity - Implementation GE’ OMNL7 SBCS PERFORM THE PROGRAMMING TASKS DESIGNATED BY THE COMPLETED SAMPLE IMPLEMENTATION FORMS ATTACHED TO THE WORK ORDER BELOW. COMPLETE THE REVIEW EXERCISE QUESTIONS PERTAINING TO THE IMPLEMENTATION FORMS PACKAGE UPON COMPLETION OF THIS LABORATORY ACTIVITY. WORK ORDER # 2.13 COMPANY NAME: NU SYSTEM CO. PHONE #: (703) 555-1212 LOCATION: RESTON. VIRGINIA WORK ORDER # 2.13 ORIGINATOR: TELECOMMUNICATIONS MANAGER TASKS: l Reestablish the default standard data base with COLD Restart. l Perform all data base modification required for tables and parameters outlined in the Implementation Forms Package. PARAMETERS: INSTRUCTIONS: (1) Complete Implementation Forms Package following instructor’s directions. (1) Check/test the operation of changes after completion of this portion of the laboratory (2) Program all required data base changes using activity. completed Implementation Forms Package. (2) Complete review exercise questions 1-9. LAB MILESTONE: . VERIFY THAT ALL PROGRAMMING CHANGES REQUESTED ON IMPLEMENTATION FORMS HAVE BEEN PERFORMED CORECTLY. e ASK INSTRUCTOR TO INSPECT DATA BASE MODIFICATIONS AND INITIAL YOUR PERFORMANCE CHECKLIST. . MAKE CERTAIN ALL QUESTIONS OF REVlEW EXERCISE 2.13 HAVE BEEN COMPLETED BEFORE SUBMITTING THE REVIEW EXERCISE TO THE INSTRUCTOR FOR GRADING. . YOU HAVE NOW COMPLETED THE DATA BASE ADMINISTRATION MODULE. 2.230
Review Exercise - Implementation s Package (2.13) INSTRUCTIONS: THE FOLLOWlNG EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL IN THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E., STUDENT WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 1. THE IMPLEMENTATION FORMS PACKAGE PROVIDES: . A. INFORMATION USED TO DETERMINE HARDWARE AND SOFTWARE FAULTS. B. A PERMANENT RECORD OF PROGRAMMING REQUIRED FOR CUSTOMER DATA BASE SPECIFICATIONS AT TIME OF INSTALLATION. C. A DESCRIPTION OF THE DEFAULT STANDARD DATA BASE D. A RECORD OF ALL PROGRAMMING CHANGES MADE AFTER LATER SVR UPGRADES. 2. THE AND IMPLEMENTATION FORMS ARE USED PRIMARILY TO PROVIDE GENERAL SYSTEM INFORMATION RATHER THAN USED AS PROGRAMMING TOOLS. 3. SYSTEM/STATION DIALING PATTERNS ARE PROGRAMMED USING THE IMPLEMENTATION FORM(S). 4. A CUSTOMER WISHING TO DEFINE CLASS OF RESTRICTION FOR RESTRICTION GROUPS WOULD COMPLETE THE IMPLEMENTATION FORM(S). 5. WHAT GTEP TABLE IS USED TO IDENTIFY TRUNK GROUP NUMBERS WHEN PROGRAMMING TRUNK ASSIGNMENTS? 2.231
Review Exercise - Implementation s Package (2.13) (Continued) 6. 7. 8. 9. THE IMPLEMENTATION FORM IS USED WHEN PROGRAMMING COMMON CARRIER ACCESS CODES FOR LEAST COST ROUTING IN AREAS WITH EQUAL ACCESS. WHAT CMC COMMAND AND PARAMETER SETTINGS ARE REQUIRED WHEN PROGRAMMING THE AUTOMATIC INTERCOM FEATURE USING THE BLF/DSS FEATURE ASSIGNMENT FORM? NAME TWO TYPES OF IMFORMATION REQUIRED FOR STATION INSTALLATION ON THE SINGLE LINE STATION DETAIL FORM THAT ARE NOT RELATED TO DATA BASE PROGRAMMING. MATCH THE FOLLOWING IMPLEMENTATION FORMS WITH THE TYPE OF INFORMATION INCLUDED ON EACH: MULTI-DIGIT/TOLL A. RESTRICTION FORM EKT FEATURE BUTTON B. ASSIGNMENT FORM C. SYSTEM SPEED CALL FORM D. STATION HUNTING GROUPS FORM E. SYSTEM OVERVIEW FORM A MAXIMUM OF 100 PHONE NUMBERS PROGRAMMED FOR SYSTEM USE. NO/lx AREA/OFFICE ASSIGNMENT TABLES IDENTIFIES TYPE OF SBSC DEVICE USED TO PROGRAM THE SYSTEM BUTTON ASSIGNMENTS PILOT STATION ASSIGNMENT 2.232
Table of Contimts Page MAINTENANCE OVERVIEW . MAINTENANCE OVERVIEW (OBJECTIVES) ........ . MAJOR MAINTENANCE FUNCTIONS .............. . MAINTENANCE TOOLS .......................... . REMOTE MAINTENANCE ......................... * PREVENTIVE MAINTENANCE ..................... . VISUAL INDICATORS OF SYSTEM STATUS ........ . CPM LED LAMPS ................................ . REMOTE ALARM STATES ........................ . INSTRUMENT ALARM BUTTON ................... . VISUAL ALARMS SCHEMATIC .................... . REVIEW EXERCISE (3.1) .......................... MAINTENANCE DATA BASE COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ ............................ ............................ ............................ ............................ ............................ ............................ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 MAINTENANCE DATA BASE COMMANDS (OBJECTIVES) .................... CLOCK,DAYANDDATE ................................................... CIRCUIT BUSY ASSIGNMENT .............................................. SOFTWARE AND DISTRIBUTED PROCESSOR VERSION NUMBER DISPLAYS . . DEVICE STATUS DISPLAY ................................................. FAULTLOGDISPLAY ..................................................... FAULT CODE TRANSLATION .............................................. SMDRPRINTERCONTROLS ............................................... RS-232-C PORT CONFIGURATION ASSIGNMENT ............................ DIAGNOSTIC TRUNK CONNECTION ASSIGNMENT .......................... TRAFFIC MEASUREMENT ................................................. CMC COMMAND SUMMARY ................................................ LABORATORY ACTIVITY (3.2) .............................................. REVIEW EXERCISE (3.2) .................................................... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............. .............. .............. .............. .............. .............. .............. .............. .............. .............. .............. 3.3 3.4 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 .................. .................. .................. .................. ................... .................. .................. .................. .................. .................. .................. .................. .................. .................. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.17 3.18 3.19 3.21 3.23 3.25 3.27 3.29 3.30 3.31 3.32 3.33 3.36 3.40 i