Home > GTE > Communications System > GTE Omni Scbs Installation And Maintenance Manual

GTE Omni Scbs Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GTE Omni Scbs Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 656
    							Review Exercise - Special System 
    Configurations 
    (2.11) (Co nued) 
    GE 
    OhMNU SBCS 
    4. THE SYSTEM WILL ALLOW A MAXIMUM OF 
    TENANT GROUPS FOR SiATlONS AND 
    TRUNKS. 
    5. WHAT PROGRAMMING WOULD BE REQUIRED TO ALLOW TENANTS TO HAVE THEIR OWN 
    INCOMING AND OUTGOING TRUNKS? 
    6. WHAT ADDITIONAL CUSTOMER PROVIDED EQUIPMENT IS REQUIRED FOR OPX 
    INSTALLATION? WHY? 
    7. WHAT PROCEDURE(S) COULD BE USED TO CHANGE THE DEFAULT STANDARD RINGING PATTERN 
    FOR AN OPX STATION? 
    8. OPX STATIONS INTERFACE TO THE OMNI SBCS THROUGH A 
    CARD. 
    2.206  
    						
    							Review Exercise - Special System 
    Configurations (2.11) (Coutinued) 
    9. WHAT PARAMETER AND SETTING IS REQUIRED FOR CMC-204 FOR DESIGNATING AN OPX 
    STATION? 
    10. MATCH EACH OF THE FOLLOWING CMC COMMANDS WITH ITS CORRECT DEFINITION: 
    CMC-100 
    CMC-102 
    CMC-200 
    CMC-201 
    CMC-204 
    CMC-251 
    CMC-254 
    CMC-400 
    CMC-503 A. 
    TRUNK DIALING GROUP AND RESTRICTION GROUP ASSIGNMENT 
    B. 
    TRUNK DATA ASSIGNMENT 
    C. 
    SYSTEM PARAMETER ASSIGNMENT 
    D. DATA SECURITY AND OPX ASSIGNMENT 
    E. TRUNK GROUP ROUTE TIMING ASSIGNMENT 
    F. 
    SMDR TENANT SCREENING 
    G. 
    STATION DIRECTORY NUMBER ASSIGNMENT 
    H. 
    NUMBERING PLAN ASSIGNMENT 
    I. STATION DATA ASSIGNMENT 
    3 3n7  
    						
    							Save/Load Procedures 
    2.208  
    						
    							2.12 Enabling Objective 
    GIVEN: . GTE OMNI SBCS 
    . GTE OMNI SBCS PERIPHERALS 
    . PORTABLE MAINTENANCE PANEL 
    . GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE 
    . LABORATORY ACTIVITY - SAVING AND LOADING OFFICE DEPENDENT 
    DATA BASE ODDB) 
    . REVIEW EXERCISE 
    ACTION: . USE OMNI SBCS PROGRAMMING TOOLS AND EQUIPMENT TO: 
    - SAVE OFFICE DEPENDENT DATA BASE TO TAPE. 
    - LOAD OFFICE DEPENDENT DATA BASE FROM TAPE. 
    - SAVE OFFICE DEPENDENT DATA BASE TO FLOPPY DISKETTE. 
    - LOAD OFFICE DEPENDENT DATA BASE FROM TAPE. 
    . COMPLETE REVIEW EXERCISE. 
    CRITERIA: . 
    DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE WITH PROCEDURES 
    OUTLINES IN OMNI SBCS GTEP MANUAL AND OMNI SBCS STUDENT 
    WORKBOOK 
    . REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN ACCORDANCE 
    WITH PASS/FAIL CRITERIA OF THIS TRAINING ORGANIZATION. 
    2.209  
    						
    							-. ,- 
    . . . __ 
    Office Dependent 
    ase to Tape 
    1 DESCRIPTION 1 
    @ AFTER PROGRAMMING CHANGES, CUSTOMIZED DATA BASE OR OFFICE DEPENDENT DATA BASE 
    (ODDB) STORED IN THE OMNI SBCS SYSTEM MAIN MEMORY MUST BE STORED TO A PMP 
    MICROCASSETTE. 
    . TIME REQUIRED TO WRITE ODDB TO TAPE IS DEPENDENT UPON SIZE OF ODDB AND LINE SPEED. 
    . SAVE PROCEDURE WILL NOT INTERRUPT CALL PROCESSING IF OPERATING AT LESS THAN 1200 
    BITS PER SECOND. 
    @ SAVE PROCEDURE CANNOT BE PERFORMED USING MASTER CONTROL TELEPHONE. 
    1 PROCEDURE 1 
    1. USE CMC-903 TO SAVE ODDB TO PMP TAPE: 
    . VERIFICATION (PI) 
    a. ENTER: 
    SAVE 
    b. PRESS ADD/CHANGE. SCREEN WILL PROMPT. *SAVE PROCESS 
    SETDATATAPE 
    HIT PF9 TO START 
    c. INSERT A BLANK 60 MINUTE MICROCASSETTE INTO THE TAPE DRIVE. (PMP WILL 
    AUTOMATICALLY REWIND TAPE IF NECESSARY). 
    d. 
    PRESS PF9 (SHIFT + PF4). SCREEN WILL DISPLAY MESSAGE THAT SAVE 
    PROCESS HAS BEGUN: 
    I 
    I 
    START  
    						
    							Saving Office Data I3ase 
    to Tape (Continued) 
    e. THEN SCREEN WILL DISPLAY TAPE DATE INCLUDING SAVED DATE, TAPE VERSION, AND VOLUME SERIAL NUMBER: 
    *SAVE PROCESS 
    SAVEODATENNIDDIY 
    TAPE VER xxx/VOL XY 
    f. WHEN SAVE PROCESS IS COMPLETED, THE SCREEN WILL DISPLAY: 
    n 
    *SAVE PROCESS 
    COMPLETION 
    c ERRORS / 
    . IF ODDB BACKUP TAPE HAS NOT BEEN INSERTED OR IF TAPE IS OVERWRITE PROTECTED, SCREEN WILL DISPLAY: 
    *SAVE PROCESS 
    r-l 
    TAPE DOES NOT EXIST 
    SEEDATATAPE 
    HIT PF9 TO START 
    INSERT TAPE OR BREAK OVERWRITE TAPE. REPEAT STEP 5 AND CONTINUE PROCEDURE. 
    . IF TAPE ENDS BEFORE SAVE PROCESS IS COMPLETED, SCREEN WILL DISPLAY: 
    *SAVE PROCESS 
    i-l DATA TAPE END 
    CHANGE DATA TAPE 
    HIT PF9 TO START 
    ATTEMPT TO LOAD TAPE AGAIN OR INSERT ANOTHER TAPE. REPEAT STEP 5 TO RESTART THE SAVE PROCESS. 
    2.211  
    						
    							Saving Office Data Base 
    Tane (Co tinued) 
    m . 
    . IF RELEASE (PFI) KEY IS ACCIDENTALLY PRESSED, SAVE PROCESS WlLL BE INTERRUPTED AND’ 
    SCREEN WILL DISPLAY: 
    *SAVE PROCESS 
    QUIT 
    BEGIN SAVE PROCEDURE AGAIN FROM STEP a. 
    2.212  
    						
    							Loading Office Dependent 
    Data Base From Tape 
    DESCRIPTION 
    @ TIME REQUIRED TO LOAD ODDB FROM TAPE IS DEPENDENT UPON SIZE OF ODDB AND LINE 
    SPEED. 
    @ ALL CALL PROCESSING STOPS DURING LOADING PROCESS. 
    . AFTER COMPLETION OF LOADING PROCESS, OMNI SBCS AUTOMATICALLY INITIATES HOT 
    RESTART. 
    1 PROCEDURE 1 
    NOTE: BECAUSE CALL PROCESSING STOPS DURING LOADING PROCESS, CHECK CALL STATUS 
    WITH DSS/BLF CONSOLE AND WAIT UNTIL CALLS ARE COMPLETED. IF LOADING RE- 
    QUIREMENT IS URGENT, INTERRUPT CALLS THROUGH EXECUTIVE OVERRIDE FEATURE AND 
    WARN USERS THAT CALL PROCESSING SERVICE WILL BE INTERRUPTED. 
    1. USE CMC-904 TO VERIFY TAPE VERSION AGAINST OMNI SBCS SYSTEM SOFTWARE 
    VERSION. 
    . VERSION IDENTIFICATION NUMBER (PI) 
    2. USE CMC-902 TO LOAD ODDB FROM PMP TAPE TO SYSTEM MEMORY. 
    . VERIFICATION (PI) 
    a. ENTER: 
    LOAD 
    b. PRESS ADD/CHANGE. SCREEN WILL PROMPT: 
    I HIT PF9 TO START 
    I 
     
    I 
    c. INSERT ODDB MICROCASSETTE TAPE. ENSURE THAT TAPE IS REWOUND. 
    2.213  
    						
    							Loading Dependent Data Base 
    ntinu.ed) 
    d. PRESS PF9 (SHIFT -t PF4). CALL PROCESSING NOW IS INTERRUPTED. SCREENI WILL DISPLAY: 
    f 1 
    *mm PROCESS 
    START 
    I-J 
    THEN SCREEN WILL DISPLAY TAPE DATA INCLUDING SAVED DATE, TAPE VERSION, AND VOLUME 
    SERIAL NUMBER: 
    e. PRESS PF9 (SHIFT + PF4) TO START LOADING PROCESS. 
    f. WHEN LOAD PROCESS IS COMPLETED, THE SYSTEM WILL AUTOMATICALLY INITIATE A HOT 
    RESTART. THE SCREEN WILL DISPLAY: 
    f I 
    - 
    9 CONFIRM HOT RESTART BY VERIFYING THAT “%ECtitii?Y CODE=” IS DISPLAYED ON SCREEN. 
    MANUALLY HOT RESTART SYSTEM (CPM CARD TOGGLE SWITCH DOWN WHILE 
    PRESSING RESTART BUTTON) IF SYSTEM FAILS TO HOT RESTART AUTOMATICALLY. 
    h. THE TIMER OVERFLOW LAMP WILL BE ON. 
    ENTER CMC-801 AND READ OUT ALL FAULTS. LAMP 
    WILL BE TURNED OFF WHEN FAULT LISTING IS COMPLETED. 
    i. THE SCREEN MAY DISPLAY “NO TRANSMISSION” IF PMP HAS BEEN UNATTENDED FOLLOWING 
    LOADING OF ODDB TAPE. THIS INDICATES THAT COMMUNICATION CHANNEL BETWEEN PMP AND 
    OMNI SBCS HAS BEEN IDLE. PRESS ANY ALPHABETIC KEY TO STOP MESSAGE. 
    2.214  
    						
    							Loading Office ependent Data Base 
    From Tape’N(Continued) 
    GTL aiM#Nn SBCS 
    ERRORS 
    . IF ODDB TAPE VERSION DOES NOT MATCH OMNI SBCS SOFTWARE VERSION,, THE SCREEN 
    WILL DISPLAY: 
    CHANGE TAPE AND 
    PRESS PF9 (SHIFT + PF4). REPEAT STEP D AND CONTINUE1 PROCEDURE. 
    e IF INSERTED TAPE IS NOT ODDB TAPE, THE SCREEN WILL DISPLAY: 
    f 1 
    CHANGE TAPE AND PRESS PF9 (SHIFT + PF4). REPEAT STEP D AND CONTINUE PROCEDURE. 
    . IF ODDB TAPE VOLUME SERIAL NUMBER IS NOT CORRECT, THE SCREEN WILL DISPLAY: 
    / 3 
    L J 
    CHANGE TAPE AND 
    PRESS PF9 (SHIFT + PF4). REPEAT STEP d AND CONTINUE PROCEDURE. 
    . IF TAPE ENDS BEFORE LOAD PROCESS IS COMPLETED, SCREEN WILL DISPLAY: 
    CHANGE TO NEXT TAPE AND 
    PRESS PF9 (SHIFT + PF4). REPEAT STEP d TO RESTART 
    LOAD PROCESS. 
    2.215  
    						
    All GTE manuals Comments (0)

    Related Manuals for GTE Omni Scbs Installation And Maintenance Manual