GTE Omni Scbs Installation And Maintenance Manual
Have a look at the manual GTE Omni Scbs Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Review Exercise - Special System Configurations (2.11) (Co nued) GE OhMNU SBCS 4. THE SYSTEM WILL ALLOW A MAXIMUM OF TENANT GROUPS FOR SiATlONS AND TRUNKS. 5. WHAT PROGRAMMING WOULD BE REQUIRED TO ALLOW TENANTS TO HAVE THEIR OWN INCOMING AND OUTGOING TRUNKS? 6. WHAT ADDITIONAL CUSTOMER PROVIDED EQUIPMENT IS REQUIRED FOR OPX INSTALLATION? WHY? 7. WHAT PROCEDURE(S) COULD BE USED TO CHANGE THE DEFAULT STANDARD RINGING PATTERN FOR AN OPX STATION? 8. OPX STATIONS INTERFACE TO THE OMNI SBCS THROUGH A CARD. 2.206
Review Exercise - Special System Configurations (2.11) (Coutinued) 9. WHAT PARAMETER AND SETTING IS REQUIRED FOR CMC-204 FOR DESIGNATING AN OPX STATION? 10. MATCH EACH OF THE FOLLOWING CMC COMMANDS WITH ITS CORRECT DEFINITION: CMC-100 CMC-102 CMC-200 CMC-201 CMC-204 CMC-251 CMC-254 CMC-400 CMC-503 A. TRUNK DIALING GROUP AND RESTRICTION GROUP ASSIGNMENT B. TRUNK DATA ASSIGNMENT C. SYSTEM PARAMETER ASSIGNMENT D. DATA SECURITY AND OPX ASSIGNMENT E. TRUNK GROUP ROUTE TIMING ASSIGNMENT F. SMDR TENANT SCREENING G. STATION DIRECTORY NUMBER ASSIGNMENT H. NUMBERING PLAN ASSIGNMENT I. STATION DATA ASSIGNMENT 3 3n7
2.12 Enabling Objective GIVEN: . GTE OMNI SBCS . GTE OMNI SBCS PERIPHERALS . PORTABLE MAINTENANCE PANEL . GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE . LABORATORY ACTIVITY - SAVING AND LOADING OFFICE DEPENDENT DATA BASE ODDB) . REVIEW EXERCISE ACTION: . USE OMNI SBCS PROGRAMMING TOOLS AND EQUIPMENT TO: - SAVE OFFICE DEPENDENT DATA BASE TO TAPE. - LOAD OFFICE DEPENDENT DATA BASE FROM TAPE. - SAVE OFFICE DEPENDENT DATA BASE TO FLOPPY DISKETTE. - LOAD OFFICE DEPENDENT DATA BASE FROM TAPE. . COMPLETE REVIEW EXERCISE. CRITERIA: . DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE WITH PROCEDURES OUTLINES IN OMNI SBCS GTEP MANUAL AND OMNI SBCS STUDENT WORKBOOK . REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING ORGANIZATION. 2.209
-. ,- . . . __ Office Dependent ase to Tape 1 DESCRIPTION 1 @ AFTER PROGRAMMING CHANGES, CUSTOMIZED DATA BASE OR OFFICE DEPENDENT DATA BASE (ODDB) STORED IN THE OMNI SBCS SYSTEM MAIN MEMORY MUST BE STORED TO A PMP MICROCASSETTE. . TIME REQUIRED TO WRITE ODDB TO TAPE IS DEPENDENT UPON SIZE OF ODDB AND LINE SPEED. . SAVE PROCEDURE WILL NOT INTERRUPT CALL PROCESSING IF OPERATING AT LESS THAN 1200 BITS PER SECOND. @ SAVE PROCEDURE CANNOT BE PERFORMED USING MASTER CONTROL TELEPHONE. 1 PROCEDURE 1 1. USE CMC-903 TO SAVE ODDB TO PMP TAPE: . VERIFICATION (PI) a. ENTER: SAVE b. PRESS ADD/CHANGE. SCREEN WILL PROMPT. *SAVE PROCESS SETDATATAPE HIT PF9 TO START c. INSERT A BLANK 60 MINUTE MICROCASSETTE INTO THE TAPE DRIVE. (PMP WILL AUTOMATICALLY REWIND TAPE IF NECESSARY). d. PRESS PF9 (SHIFT + PF4). SCREEN WILL DISPLAY MESSAGE THAT SAVE PROCESS HAS BEGUN: I I START
Saving Office Data I3ase to Tape (Continued) e. THEN SCREEN WILL DISPLAY TAPE DATE INCLUDING SAVED DATE, TAPE VERSION, AND VOLUME SERIAL NUMBER: *SAVE PROCESS SAVEODATENNIDDIY TAPE VER xxx/VOL XY f. WHEN SAVE PROCESS IS COMPLETED, THE SCREEN WILL DISPLAY: n *SAVE PROCESS COMPLETION c ERRORS / . IF ODDB BACKUP TAPE HAS NOT BEEN INSERTED OR IF TAPE IS OVERWRITE PROTECTED, SCREEN WILL DISPLAY: *SAVE PROCESS r-l TAPE DOES NOT EXIST SEEDATATAPE HIT PF9 TO START INSERT TAPE OR BREAK OVERWRITE TAPE. REPEAT STEP 5 AND CONTINUE PROCEDURE. . IF TAPE ENDS BEFORE SAVE PROCESS IS COMPLETED, SCREEN WILL DISPLAY: *SAVE PROCESS i-l DATA TAPE END CHANGE DATA TAPE HIT PF9 TO START ATTEMPT TO LOAD TAPE AGAIN OR INSERT ANOTHER TAPE. REPEAT STEP 5 TO RESTART THE SAVE PROCESS. 2.211
Saving Office Data Base Tane (Co tinued) m . . IF RELEASE (PFI) KEY IS ACCIDENTALLY PRESSED, SAVE PROCESS WlLL BE INTERRUPTED AND’ SCREEN WILL DISPLAY: *SAVE PROCESS QUIT BEGIN SAVE PROCEDURE AGAIN FROM STEP a. 2.212
Loading Office Dependent Data Base From Tape DESCRIPTION @ TIME REQUIRED TO LOAD ODDB FROM TAPE IS DEPENDENT UPON SIZE OF ODDB AND LINE SPEED. @ ALL CALL PROCESSING STOPS DURING LOADING PROCESS. . AFTER COMPLETION OF LOADING PROCESS, OMNI SBCS AUTOMATICALLY INITIATES HOT RESTART. 1 PROCEDURE 1 NOTE: BECAUSE CALL PROCESSING STOPS DURING LOADING PROCESS, CHECK CALL STATUS WITH DSS/BLF CONSOLE AND WAIT UNTIL CALLS ARE COMPLETED. IF LOADING RE- QUIREMENT IS URGENT, INTERRUPT CALLS THROUGH EXECUTIVE OVERRIDE FEATURE AND WARN USERS THAT CALL PROCESSING SERVICE WILL BE INTERRUPTED. 1. USE CMC-904 TO VERIFY TAPE VERSION AGAINST OMNI SBCS SYSTEM SOFTWARE VERSION. . VERSION IDENTIFICATION NUMBER (PI) 2. USE CMC-902 TO LOAD ODDB FROM PMP TAPE TO SYSTEM MEMORY. . VERIFICATION (PI) a. ENTER: LOAD b. PRESS ADD/CHANGE. SCREEN WILL PROMPT: I HIT PF9 TO START I I c. INSERT ODDB MICROCASSETTE TAPE. ENSURE THAT TAPE IS REWOUND. 2.213
Loading Dependent Data Base ntinu.ed) d. PRESS PF9 (SHIFT -t PF4). CALL PROCESSING NOW IS INTERRUPTED. SCREENI WILL DISPLAY: f 1 *mm PROCESS START I-J THEN SCREEN WILL DISPLAY TAPE DATA INCLUDING SAVED DATE, TAPE VERSION, AND VOLUME SERIAL NUMBER: e. PRESS PF9 (SHIFT + PF4) TO START LOADING PROCESS. f. WHEN LOAD PROCESS IS COMPLETED, THE SYSTEM WILL AUTOMATICALLY INITIATE A HOT RESTART. THE SCREEN WILL DISPLAY: f I - 9 CONFIRM HOT RESTART BY VERIFYING THAT “%ECtitii?Y CODE=” IS DISPLAYED ON SCREEN. MANUALLY HOT RESTART SYSTEM (CPM CARD TOGGLE SWITCH DOWN WHILE PRESSING RESTART BUTTON) IF SYSTEM FAILS TO HOT RESTART AUTOMATICALLY. h. THE TIMER OVERFLOW LAMP WILL BE ON. ENTER CMC-801 AND READ OUT ALL FAULTS. LAMP WILL BE TURNED OFF WHEN FAULT LISTING IS COMPLETED. i. THE SCREEN MAY DISPLAY “NO TRANSMISSION” IF PMP HAS BEEN UNATTENDED FOLLOWING LOADING OF ODDB TAPE. THIS INDICATES THAT COMMUNICATION CHANNEL BETWEEN PMP AND OMNI SBCS HAS BEEN IDLE. PRESS ANY ALPHABETIC KEY TO STOP MESSAGE. 2.214
Loading Office ependent Data Base From Tape’N(Continued) GTL aiM#Nn SBCS ERRORS . IF ODDB TAPE VERSION DOES NOT MATCH OMNI SBCS SOFTWARE VERSION,, THE SCREEN WILL DISPLAY: CHANGE TAPE AND PRESS PF9 (SHIFT + PF4). REPEAT STEP D AND CONTINUE1 PROCEDURE. e IF INSERTED TAPE IS NOT ODDB TAPE, THE SCREEN WILL DISPLAY: f 1 CHANGE TAPE AND PRESS PF9 (SHIFT + PF4). REPEAT STEP D AND CONTINUE PROCEDURE. . IF ODDB TAPE VOLUME SERIAL NUMBER IS NOT CORRECT, THE SCREEN WILL DISPLAY: / 3 L J CHANGE TAPE AND PRESS PF9 (SHIFT + PF4). REPEAT STEP d AND CONTINUE PROCEDURE. . IF TAPE ENDS BEFORE LOAD PROCESS IS COMPLETED, SCREEN WILL DISPLAY: CHANGE TO NEXT TAPE AND PRESS PF9 (SHIFT + PF4). REPEAT STEP d TO RESTART LOAD PROCESS. 2.215