,. :r .,,, ,,‘. I.~. /: ) ,; -x1 T ADMINI TIO Pr a an LF/DSS 2.38
2.2 Enabling Objective GIVEN: ACTION: l GTE OMNI SBCS . GTE OMNI SBCS PERIPHERALS . PORTABLE MAINTENANCE PANEL . GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE . LABORATORY ACTIVITY - PROGRAMMING STATION INSTRUMENTS AND BLF/DSS MODULES. . REVIEW EXERCISE . USE OMNI SBCS PROGRAMMING TOOLS AND EQUIPMENT TO: - INSTALL AND REMOVE EKT INSTRUMENTS, SLT INSTRUMENTS, AND BLF/DSS MODULES. - ASSIGN AND MODIFY EKT, BLF/DSS BUTTON ASSIGNMENTS. . COMPLETE REVIEW EXERCISE. CRITERIA: . DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE WITH PROCEDURES OUTLINED IN OMNI SBCS GTEP MANUAL AND OMNI SBCS STUDENT WORKBOOK. . REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING PROGRAM. 2.39
,_. r-. ; I /:’ ‘;, Default Standard EKT Button Assignment/CS-10 and CS-20 GiE OMNU sl3cs STANDARD CONFIGURATION (CARD SLOPS 00 OR 02-l 4) ALTERNATE CONFIGURATION (CARD SLOT 01) 6 2.40
Default Standard CSD* Button Assign CSD CONNECTED TO AN 8DTC CARD CSD CONNECTED TO 8DTC CARDS INSTALLED IN CARD SLOT 01 INSTALLED IN CARD SLOTS 02-l 4 ~~@kq~p&-I lTkpkyA**l ,--I SPEAKER - I-1 MUTE I-1 TRANSFER 1-1 HOLD I SPEAKER II MUTE -FIXED KEYS I-1 TRANSFER I-1 HOLD CSD EQUIPPED WITH DTA INTERFACE INSTALLED IN CARD SLOTS 00,03,08,09, and 12 SPEAKER II MUTE -I- FIXED KEYS ,--I TRANSFER I-1 HOLD I I _-. .-_ * PACKAGE B/PHASE 1.5 AVAMBLITY 2.41 -FIXED KEYS
1 PROCEDURE ) * 1. COLD RESTART THE SYSTEM (IF AT TIME OF lNlTlAL SYSTEM INSTALLATION) OR HOT RESTART THE SYSTEM (IF INSTALLING INSTRUMENT AFTER INITIAL SYSTEM INSTALLATION). 2. REFER TO DEFAULT STANDARD DATA BASE TABLES FOR DEFAULT DIRECTORY NUM ER ASSIGNMENT AND B TTON ASSIGNME (FOR CS-10, CS-20, OR CSD). 3. PROGRAM DESIRED DATA BASE CHANGES WWIT PPLICABLE CMC S USING DEFAULT STANDARD SETTINGS AS BASIS FOR THE CUSTOMIZED DATA BASE. *ASSUMES LINE CARD HAS BEEN INSTALLED IN ABPPROPRIATE Sk AND TELEPHONE INSTRUMENT HAS BEEN PHYSICALLY CONNECT TO DESIRED SLOT AND CIRCUIT LOCATION. 2.42
ogram Station In 1 PROCEDURE ] * (REFER TO OMNI SBCS GTEP MANUAL, DATA BASE PROGRAMMING SECTION) 1. USE CMC-200 TO ASSIGN: . EQUIPMENT NUMBER (Pi) . STATION DIRECTORY NUMBER (P2) . TYPE OF TERMINAL (P3) . COPIED STATION DIRECTORY NUMBER (P4) 2. USE CMC-201 TO ASSIGN: . DIRECTORY NUMBER (Pl) . OPERATION MODE (P2) . TYPE OF DIALING (P3) . TENANT NUMBER (P4) . METERING GROUP (P5) 3. USE CMC-202 TO ASSIGN: . STATION DIRECTORY NUMBER (PI) . DAY CLASS OF SERVICE (P2) . NIGHT CLASS OF SERVICE (P3) . DAY CLASS OF RESTRICTION (P4) . NIGHT CLASS OF RESTRICTION (P5) P1:017 p4 I CMC=201 Pl: 215 P4: 2 P2: 1 P5: 2 P3: 3 CMC=202 Pl: 215 P4: 1 P2: 1 PS: 1 P3: 3 2.43
Station Instruments/Manu (Continued) GTE OMNi SBCS 4. USE CMC-204 (IF APPLICABLE) TO ASSIGN: . STATION DIRECTORY NUMBER (Pl) . DATA SECURE PATH (P2) . OFF PREMISES EXTENSION (P3) . SLT WITH MESSAGE WAITING LAMP (P4)** 5. USE CMC-203 (ONLY FOR CS-10, CS-20, AND CSD INSTRUMENTS) TO ASSIGN FEATURES OR SERVICES TO BUTTONS: . STATION DIRECTORY NUMBER (Pl) . BUTTON NUMBER (P2) @ FEATURE NUMBER (P3) . SUPPLEMENTARY DATA (P4) . LINE TERMINATION TYPE (P5) . RINGING MODE (P6) NOTE: IF LINE BUTTON IS ASSIGNED TO A CS-10, CS-20, OR CSD INSTRUMENT, USE CMC-253 TO ASSIGN TRUNK TERMINATION. (REFER TO STUDENT WORKBOOK FOR INSTRUCTIONS FOR PROGRAMMING TRUNK TERMINATION OR KEY SYSTEM TYPE LINES.) *ASSUMES LINE CARD HAS BEEN INSTALLED IN APPROPRIATE SLOT AND TELEPHONE INSTRUMENT HAS BEEN PHYSICALLY CONNECTED TO DESIRED SLOT AND CIRCUIT. **PACKAGE B/PHASE 1.5 AVAILABILITY 2.46 CMC= 204 Pl: 215 P4: 0 P2: 1 P3: 0 CMC= 203 Pl: 215 P4: P2: IO P5: P3: a5 P6:
Programming Station odification- tation I formation PROCEDURE (CHANGE) 1. USE CMC-203 TO: @ REMOVE UNWANTED EKT BUTTON ASSIGNMENTS . ENTER NEW BUTTON ASSIGNMENTS 2. USE CMC-200 TO: . CHANGE STATION DIRECTORY NUMBERS AND/OR EQUIPMENT NUMBERS 3. CHECK CMC-201, CMC-202 AND CMC-204 TO: 0 MAKE ANY CHANGES AFFECTED BY DIRECTORY NUMBER CHANGE (COS/COR OPERATION MODE TYPE OF DIALING, TENANT NUMBER, METERING GROUP, DATA SECURITY OR OPX DESIGNATION. 4. CHECK CMC-306 AND CMC-307 TO: . MAKE ANY CHANGES AFFECTED BY EQUIPMENT NUMBER CHANGE. IPROCEDURE] (REMOVE) 1. USE CMC-203 TO: . REMOVE ALL BUTTON ASSIGNMENTS ASSOCIATED WITH STATION. 2. CHECK CMC-201, CMC-204, CMC-210, CMC-301, CMC-302 AND CMC-304 TO: . REMOVE STATION DIRECTORY NUMBERS FROM APPLICABLE TABLES. 3. USE CMC-200 TO: l CHANGE STATION DIRECTORY NUMBER ASSIGNMENT AND EQUIPMENT NUMBER ASSIGNMENT. 4. CHECK CMC-306 AND CMC-307 TO: . CHANGE STATION DIRECTORY NUMBERS AFFECTED BY THE CHANGES. 2.46
Programming Station Instruments/ C Corn and Summary CATEGORY CMC TABLE FUNCTION . STATION DN 200 ASSIGNS, REMOVES, OR CHANGES ASSIGNMENT DIRECTORY NUMBER AND TYPE OF TERMINAL. . STATION DATA ASSIGNMENT . STATION COS/COR ASSIGNMENT l EKT BUTTON ASSIGNMENT . DATA SECURITY AND OPX 201 202 203 204 ASSIGNS, REMOVES, OR CHANGES A STATION’S OPERATION MODE, TYPE OF DIALING, TENANT NUMBER, OR METERING GROUP NUMBER. ASSIGNS, REMOVES, OR CHANGES A STATION’S CLASS OF SERVICE OR CLASS OF RESTRICTION LEVEL FOR DAY OR NIGHT MODE. ASSIGNS, REMOVES, OR CHANGES FEATURE BUTTON ASSIGNMENT ON EKT. IDENTIFIES A DIRECTORY NUMBER AS A DATA SECURE LINE OR OFF-PREMISE EXTENSION. 2.47