GTE Omni Scbs Installation And Maintenance Manual
Have a look at the manual GTE Omni Scbs Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
6PFT and 6PFE Cards Installation GE OMNi SBCS. 6PFT CARD CAN BE INSTALLED ONLY IN BASIC CABINET. . 6PFE CARD CAN BE INSTALLED IN EITHER BASIC OR EXPANSION CABINETS DEPENDING ON TOGGLE SWITCH SETTING. 1.INSTALL 6PFT CARD IN SLOT 22 OF BASIC CABINET. 2.INSTALL 6PFE CARD IN EXPANSION CABINET USING (GPFE MAY BE USED IF TOGGLE SWITCH IS SET FOR BASIC MODE.) EXPANSION MODE TOGGLE SETTING. 3.CROSS CONNECT SIGNAL LEADS FOR BOTH CARDS (USE JAO-JAI LEAD OF CARD IN BASIC CABINET AND NAO-NAI LEAD IN EXPANSION CABINET), USING SYSTEM CROSS CONNECTIONS DESIGNATED BELOW: APM PINNUMBERSIGNALNAME 34 9 35 10 34 935 10 36JAORED-BRN JAIBRN-RED NAORED-SL NAISL-RED JAORED-BRN JAIBRN-RED NAORED-SL NAISL-RED CDF CABLE COLOR CODECARD SLOT 48WCPTTL2TTENUMBERLEAD NAMELEAD NAMELEAD NAME BASIC (SPFT?iPFE) EXPANSION (6PFTt’tPFE) JAOREMOTE ALARM-MAJOR JAI EXPANSION-JAO/l NO0REMOTE ALARM-MINOR NAIREMOTE ALARM-MINOR JAOREMOTE ALARM-MAJOR JAIREMOTE ALARM-MAJOR NAOREMOTE ALARM-MAJOR NAIBASIC-JAO/l 5.47
6PFT and 6PFE Cards Installation (Continued) \ 90-EXP 80 EXPIBASIC SWITCH -Is-BASIC -SW270 I ii- @IF 6PFE IS USED IN SINGLE CABINET ONLY (STANDARD SYSTEM CONFIGURATION) OR IS INSTALLED IN BASIC CABINET (EXPANDED SYSTEM CONFIGURATION), THEN TOGGLE SWITCH MUST BE SET FOR BASIC MODE (SEE ABOVE). @IF 6PFE IS USED IN EXPANSION CABINET (EXPANDED SYSTEM CONFIGURATION), THEN TOGGLE SWITCH MUST BE SET FOR EXPANSION MODE. 5.48
6PFT and 6PFE Card Installation (Continued) 6PFT AND 6PFE CROSS CONNECTION MAJOR ALARM [IMINOR ALARM CJ. 00-v00JAO00 00JAl 00NAO00 NAlI00 00I uu /BASIC CABINET 0000JAO00 00JAl NAO0OO--NAI -j- 6PFEEXPANSION CABINET 5.49
Unit (nstallation DIAGRAM REPRESENTS A TYPICAL EXAMPLE OF CROSS CONNECTlONS FOR A DIU INSTRUMENT. EACH DIU REQUIRES ONLY ONE PAIR OF WIRES FOR TIP AND RING. ON THE CDF TERMINAL BLOCK, ONLY EVERY OTHER PAIR OF WIRES IS USED. EXAMPLE ILLUSTRATES A CDF CROSS CONNECTION FOR AN 8DTC INTERFACE CARD IN SLOT 00, USING CABLE NUMBER (CN)O. CONNECTOR BLOCK WOULD HANDLE ALL EIGHT CIRCUITS FOR,THE CARD SLOT IDENTIFIED ABOVE. REFER TO CDF CROSS CONNECTION REFERENCE IN STUDENT WORKBOOK, INSTALLATION MODULE FOR CROSS CONNECTION INSTRUCTIONS FOR OTHER CARD AND EQUIPMENT CONFIGURATIONS.TERMINAL BLOC T25 PAIRTIP L2/RED MODULAR CABLE DATA INTERFACE UNIT 5.50TYPICAL DIU CROSS CONNECTION
Installation of Data Interface Unit (DIU)’with Printer, Modem, or Data Terminal GTE OMNi SBCS DIUTTRI?8DTC .DIU IS CONNECTED DIRECTLY TO A CIRCUIT ON THE 8DTC CARD AND USES ONE 64 KBPS CHANNEL. .THE DIU CAN ACCOMMODATE A PRINTER, DATA TERMINAL, OR MODEM (DTE/DCE) OF UP TO 19.2 KBPS SYNCHRONOUS/ASYNCHRONOUS WITH ITS RS-232-C INTERFACE. 1.WIRE CROSS CONNECTION FOR THE DIU TO A CDF TERMINAL BLOCK FROM A CIRCUIT ON THE 8DTC CARD (REFER TO CDF CROSS CONNECTION TABLE IN GTEP MANUAL). 2.FOR HOTEL/MOTEL CONFIGURATION CONNECT THE PRINTER TO THE DIU WITH RS-232-C CABLE. THE PRINTER AND DIU MUST BE IN DATA TERMINAL EQUIPMENT (DTE) MODE. 3.FOR USE WITH A MODEM, CONNECT MODEM TO DIU WITH RS-232-C CABLE. THE DIU MUST BE IN DATA COMMUNICATION EQUIPMENT (DCE) MODE. IRS232C DTElDCEMODEMLINEI I RINGERDTEIDCE REAR VIEW 5.51
nsole ItallatisnDESCRIPTION @EACH ATTENDANT CONSOLE WEl,,jlRES TWO PAIRS OF WIRES: ONE PAIR FOR TIPAND RING, THE OTHER FOR DATA/POWER. @REFER TO EKT CROSS CONNECTION REFERENCE CHART IN MODULE I, FOR CROSS CONNECT WIRING INSTRUCTIONS. @ATTENDANT CONSOLE CAN BE LOCATED UP TO 300 FEET FROM SYSTEM CABINET USING 24 AWG CABLE WITH FOUR LEAD WIRING (ONE PORT) AS DESCRIBED ABOVE. 0FOR DISTANCES OF UP TO 2000 FEET, TWO PORTS CAN BE WIRED (AS ILLUSTRATED IN DIAGRAlVl ON FOLLOWING PAGE), USING ONE AQDITIONAL PAIR OF DATA/POWER LEADS. 5.52
Expansion Cabinet InstallationBASIC CABINETGTll OMli SBGS IICABINETswsn-------------_ -nv’---- GROUND,Ar-- FkfSAFETY GROUND TI GROUNDI EXPANSION CABINETI I I-T-lCABINET SWE------------I I. INSTALLATION OF SECOND (EXPANSION) CABINET FOR EXPANDED SYSTEM CONFIGURATION REQUIRES CONNECTION OF SWB CARD (IN BASIC CABINET) TO SWE CARD (IN EXPANSION CABINET) USING AN INTERMODULE CABLE. PROCEDURE 1.ENSURE THAT SYSTEM POWER IS OFF FOR BOTH CABINETS. 2.GROUND END OF INTERMODULE CABLE CONNECTED TO BASIC CABINET, THEN CONNECT CABLE TO BASIC CABINET DOOR WITH BASIC CABINET SCREW. 3.THREAD CABLE THROUGH OPENINGS IN BOTTOM OF BOTH BASIC AND EXPANSION CABINETS. 4.CONNECT CABLE TO EXPANSION CABINET DOOR WITH EXPANSION CABINET SCREW. 5.CONNECT SIGNAL GROUND WIRES (AS ILLUSTRATED IN DIAGRAM) FOR BOTH CABINETS. 6.CONNECT FRAME GROUND WIRES (AS ILLUSTRATED IN DIAGRAM) FOR BOTH CABINETS. 5.53
I-Mel/Motel Printer Installation HOTEL/MOTEL PRINTERINTERFACE HOTEL/MOTEL PRINTER NO. 1RS-232-C DIU OR DTA HOTEL/MOTEL II l-+-j--l 1DIU :?ADTC CPM = CENTRAL PROCESSING UNIT AND hiEMORY CARD CHT = CHARACTER TRUNK CARD DIU = DATA INTERFACE UNIT DTA = DATA ADAPTER DTC = PROPRIETARY DIGITAL TELEPHONE INTERFACE CARD SWC = SWITCHING CONTROL CARD MEM = MEMORY CARD swc -cCHT ENSURE THAT 4CHT CARD IS INSTALLED IN SYSTEM. CONNECT DIU TO SYSTEM VIA TWO WIRE INTERFACE (TO 8DTC CARD OR CONNECT TO DTA ADAPTER). CONNECT THE HOTEL/MOTEL PRINTER TO THE RS-232-C PORT OF THE DIU OR DTA. PROGRAM REQUIRED DATA BASE ENTRIES. 5.54
Hotel/Motel Printer Installation (Continued) HOTEL/MOTEL COMMUNICATION REQUIREMENTSITEM INTERFACE SPEED, CODE PARITY CHARACTER LENGTHSTOP BIT ON/OFF OPTION POWER ON/OFF OPTIONREQUIREMENT* RS-232-C, DTE MODE ASYNCHRONOUS, UP TO 19.2 KBPS 7 BIT ASCIINONE/ODD/EVEN 7 BIT/8 BIT **,80 CHARACTERS1 BIT/2 BIT AVAILABLE NOT AVAILABLE * CONFIGURATION CAN BE MODIFIED BY USING MAINTENANCE COMMANDS (CMC-222 AND CMC-223), ACCORDING TO THE CHARACTERISTICS OF THE INSTALLED PRINTER.** WHEN 8 BIT OPTION IS SELECTED, THE MOST SIGNIFICANT BIT MUST BE A SPACE OR A ZERO. 5.55