Have a look at the manual GTE Omni Scbs Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
T nue PROGRAMMING LEAST COST ROUTING @ PROGRAMMING LEAST COST ROUTING (OBJECTIVES) ..................................... 2.183 . PROGRAMMING LEAST COST ROUTING ................................................. 2.184 . CMC COMMAND SUMMARY ........................................................... 2.186 . LABORATORY ACTIVITY (2.10) ......................................................... 2.187 . REVIEW EXERCISE (2.10) .............................................................. 2.192 PROGRAMMING SPECIAL SYSTEM CONFIGURATIONS . PROGRAMMING SPECIAL SYSTEM CONFIGURATIONS (OBJECTIVES) .......................... 2.195 . SBCS BEHIND A PABX ............................................................... 2.196 . TENANTASSIGNMENTS .............................................................. 2.197 . OFF-PREMISES EXTENSION ........................................................... 2.199 . CMC COMMAND SUMMARY ........................................................... 2.200 . LABORATORY ACTIVITY (2.11) ......................................................... 2.202 0 REVIEW EXERCISE (2.11) ............................................................. 2.205 SAVE/LOAD PROCEDURES . SAVE/LOAD (OBJECTIVES) ........................................................... 2.h9 . SAVING ODDB TO TAPE .............................................................. 2.210 . LOADING ODDB FROM TAPE .......................................................... 2.213 . SAVING AND LOADING ODDB TO FLOPPY DISKETTE ....................................... 2.217 . LABORATORY ACTIVITY (2.12) ......................................................... 2.220 . REVIEW EXERCISE (2.12) ............................................................. 2.225 IMPLEMENTATION FORMS PACKAGE . IMPLEMENTATION FORMS (OBJECTIVES) ................................................ 2.229 @ LABORATORY ACTIVITY (2.13) ......................................................... 2.230 . REVIEW EXERCISE (2.13) ............................................................. 2.231
Termin GIVEN: a 0 0 8 ACTION: 0 m 8 CRITERIA: 0 0 GTE OMNI SBCS PORTABLE MAINTENANCE PANEL GTE OMNI SBCS PERIPHERALS PMP CONTROL PROGRAM AND BLANK OFFICE DEPENDENT DATA BASE TAPES GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE GTE OMNI SBCS IMPLEMENTATION FORMS PACKAGE LABORATORY ACTIVITIES WRITTEN TEST MODIFY GTE OMNI SBCS SYSTEM DATA BASE AND VERIFY PROPER OPERATION. USE DATA COLLECTION AND INSTALLATION PROGRAMMING FORMS TO CUSTOMIZE GTE OMNI SBCS DATA BASE. COMPLETE AND PASS WRITTEN TEST. DATA BASE WILL BE MODIFIED IN ACCORDANCE WITH PROCEDURES OUTLINED IN OMNI SBCS GTEP MANUAL AND CORRECTLY USING DATA COLLECTION AND INSTALLATION PROGRAMMING FORMS. TEST WILL BE COMPLETED CORRECTLY IN ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING ORGANIZATION. 2.1
GIVEN: ACTION: CRITERIA: . GTE OMNI SBCS . PORTABLE MAINTENANCE PANEL 0 PMP CONTROL PROGRAM . GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE l PMP PRIMER l LABORATORY ACTIVITY REVIEW EXERCISE @ IDENTIFY AND USE GTE OMNI SBCS PROGRAMMING TOOLS AND EQUIPMENT BY DEMONSTRATING CORRECT PROCEDURES TO: - LOAD AND INITIALIZE PMP CONTROL PROGRAM. - OBTAIN SOFTWARE SECURITY ACCESS. - OPERATE PORTABLE MAINTENANCE PANEL. - ENTER, MODIFY, AND DELETE PARAMETER VALUES FOR CMC COMMANDS. - LOAD GTE OMNI SBCS OPERATING SYSTEM AND DEFAULT STANDARD DATA BASE WITH COLD RESTART. . COMPLETE REVIEW EXERCISE. . DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE WITH PROCEDURES OUTLINED IN OMNI SBCS GTEP MANUAL, PMP PRIMER, AND OMNI SBCS STUDENT WORKBOOK. . REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING ORGANIZATION. 2.13
0 Wel3ieW - Syste ata Base DEFINITION: SOFTWARE DRIVEN AND SOFTWARE CONTROLLED SYSTEM WHICH PROVIDES FLEXIBILITY FOR DATA BASE MODIFICA- TIONS AND ALLOWS EFFICIENT UPGRADE OF SYSTEM. LOCATION: RESIDENT ON CPM AND MEM CARDS PACKAGING: ORGANIZED BY CHANGE AND MAINTENANCE CODE (CMC) COMMAND TABLES FOR EASY REFERENCE AND MODIFICATION BACKUP: MICROCASSETTE TAPE OR FLOPPY DISKETTE. 2.4
Data Base Capabilities . CUSTOMIZING THE OMNI SBCS DEFAULT STANDARD DATA BASE . STORING MODIFICATIONS TO THE OFFICE DEPENDANT DATA BASE (ODDB) TAPE OR FLOPPY DISK. @ PERFORMING MAINTENANCE THROUGH FAULT ISOLATION AND TROUBLE SHOOTING STRATEGIES. . PERFORMING ROUTINE DIAGNOSTIC PROCEDURES. 2.5
Programming Tools and Equipment . SBCS OPERATING SYSTEM SOFTWARE - CONTAINS OPERATING PROGRAM WITH CHANGE AND MAINTENANCE TABLES STORED IN ROM. - CONTAINS DEFAULT DATA BASE WHICH IDENTIFIES AND CONTROLS SYTEM HARDWARE AND FEATURE ACCESS. - WRITTEN IN CHILL HIGH LEVEL PROGRAMMING LANGUAGE. * PROGRAMMING DEVICES/EQUIPMENT - PORTABLE MAINTENANCE PANEL (PMP) EPSON HX-20 MICROCOMPUTER - PMP CONTROL PROGRAM TAPE OR FLOPPY DISKETTE - OFFICE DEPENDENT DATA BASE TAPE (ODDB) OR FLOPPY DISKETTE - MASTER CONTROL TELEPHONE (CSD ELECTRONIC TELEPHONE SET) * . OPTIONAL EQUIPMENT - MODEM - REMOTE MAINTENANCE CAPABILITY - FLOPPY DISKETTE DRIVE - COMPATIBLE WITH PMP - PERFORMS SAVE/LOAD FUNCTION IN LESS TIME THAN MICROCASSETTE TAPE . CHANGE AND MAINTENANCE CODE COMMAND (CMC) TABLES PORTABLE MAINTENANCE PANEL CSD TELEPHONE AS MASTER CONTROL TELEPHONE - OMNI SBCS GTEP MANUAL, MAINTENANCE AND DATA BASE PROGRAMMING SECTIONS. *PACKAGE B/PHASE 1.5 AVAILABILITY 2.6
Portable Maintenance Panel (Epson HX-20 Microcomputer) I *m CASSETTE DRIVE ON/OFF SWITCH . 80 CHARACTER ALPHANUMERIC LCD DISPLAY a BATTERY OPERATED (AC POWER SUPPLY FOR RECHARGING) . RS-232-C PORT FOR CABLE INTERFACE WITH OMNI SBCS . STANDARD KEYBOARD WITH SPECIAL FUNCTION KEYS 0 BUILT IN MICROCASSETTE DRIVE FOR LOADING AND STORING THE PMP CONTROL PROGRAM AND OFFICE DEPENDENT DATA BASE . BUILT IN MICROPRINTER FOR HARD COPY OF SCREEN DISPLAY 2.7
. FOR COMMUNICATION BETWEEN PMP AND OMNl SBCS, THE PMP CONTROL PROGRAM PORT CONFIGURATION MUST MATCH THE OMNI SBCS IRS-2324 PORT AT CN13, I/O 0. @ PORT CONFIGURATION IS PRESET TO FOLLOWING VALUES: - BIT RATE = 1200 BAUD - STOP BITS = 1 BIT - PARITY = EVEN - CHARACTER LENGTH = 7 BITS - ECHO = OFF @ PORT CONFIGURATION MAY BE CHANGED TH CMC-900 (refer to CS GTEP ANUAL, DATA BASE PROG NG SECTION). OWERING T E PMP OFF AND ON RETUR PORT CONFIGURATION. MP TO THE PRESET’ 2.9