Data Interface Unit (DIU) Programming DESCRIPTION .PROVIDES STANDALONE DATA STATION CAPABILITY WITH TERMINAL, MODEM, OR PRINTER . PROGRAMMABLE DIU FEATURES INCLUDE:- COS/COR - DATA ATTRIBUTES - TENANT GROUP - DATA HUNT GROUP - DATA HOT LINE piiGEq 1.ASSIGN THE DIU AS A DATA STATION WITH CMC-220: .EQUIPMENT NUMBER OF DATA STATION (PI) .DIRECTORY NUMBER OF DATA STATION (P2) @DATA TERMINAL TYPE (P3) - (4 = DIU) .DIRECTORY NUMBER OF VOICE STATION (P4) - BLANK 2.ASSIGN COS/COR TO DIU DATA STATION WITH CMC-221: .DIRECTORY NUMBER OF DATA STATION (Pl).CLASS OF SERVICE DAY (P2) .CLASS OF SERVICE NIGHT (P3) .CLASS OF RESTRICTION DAY (P4) .CLASS OF RESTRICTION NIGHT (P5) 5.86 CMC = 220 Pl: 030 P4: P2: 4700 P5: P3: 4 CMC = 221 Pl: 4700P4:1 P2: 1P5:1 P3: 1
Qata Interface Unit (DIU) Programmin(ContinPROCEDURE (Continued) . 3.ASSIGN DATA ATTRIBUTES OF DIU WITH CMC-222: @DIRECTORY NUMBER OF DATA STATION (PI). DATA SPEED (P2) 0 SYNCHRONIZATION AND COMMUNICATION (P3) . WORD STRUCTURE (P4) l ,PARITY (P5) 8 ECHOPLEX (P6) 4. ASSIGN DATA ATTRIBUTES AND RS-232-C INTERFACE FOR DIU WITH CMC-223:. DIRECTORY NUMBER OF DATA DIU (Pl). CALL CONTROL MODE (P2). RS-232-C INTERFACE SIGNAL MODE 1 (P3) 0RS-232-C INTERFACE SIGNAL MODE 2 (P4) 5.ASSIGN DATA ATTRIBUTES, TENANT GROUP, AND METERING GROUP TO DIU WITH CMC-224:. DIRECTORY NUMBER OF DATA DIU (Pl) e CALL OPERATION MODE (P2) @DIAL MODE (P3) - (BLANK) @ TENANT NUMBER (P4) @ METERING GROUP (P5)CMC = 222 Pl: 4700P4: 1 P2: 5P5: 3 P3: 3CMC = 223 Pl: 4700P4: 1 P2: 010 P3:CMC = 224 Pl: 4700 P4: P2: 1P5: P3: 0 5.87
PROCEDURE (Continued)6.ASSIGN DIU DATA STATION TO HUNT GROUP WITH CMC-301: ICMC = 301 Pl: 51P4: 1.STATION HUNTING GROUP NUMBER (Pl) - (51 - 60)P2: 1 l TERMINATING ORDER (P2)P3: 4700 . DIRECTORY NUMBER OF DATA STATION (P3). HUNTING TYPE (P4) 1 7.ASSIGN DIU DATA STATIONS TO HOT LINE SERVICE WITH CMC-304: eHOT LINE NUMBER (Pl) - (51 - 90) . ORIGINATING DATA STATION (DIRECTORY NUMBER) - (P2). TERMINATING DATA STATION DN (DIRECTORY NUMBER) - (P3) IData Interface Unit (DILJ)Programming (Continued) 5.88
Data Interface Unit (DIU) Programming - CMC Command Summary CATEGORY. DATA STATION ASSIGNMENT . DATA STATION COS/COR ASSIGNMENT e DATA STATION ATTRIBUTES ASSIGNMENT (I) @ DATA STATION’S ATTRIBUTES ASSIGNMEMTS (II) AND RS-232-C SIGNAL MODES @ DATA STATION ATTRIBUTES ASSIGNMENT (Ill) @ DATA STATION HUNT GROUP ASSIGNMENT 8 DATA STATION HOT LINE ASSIGNMENTCMC TABLE CMC-220 \ CMC-221 CMC-222 CMC-223 CMC-224 CMC-301 CMC-304 5.89 FUNCTION INSTALLS OR REMOVES DIU AS DATA STATION WITH ITS ASSOCIATED DIRECTORY NUMBERSCHANGES DATA STATION‘S COS/COR ASSIGNMENTASSIGNS DATA STATION‘S ATTRIBUTES INCLUDING DATA SPEED, SYNCHRONI-ZATION AND COMMUNCATIONS WORD STRUCTURE, PARITY, AND ECHOPLEXASSIGNS DATA STATION’S ATTRIBUTES INCLUDING CALL CONTROL MODE AND RS-232-C INTERFACE SIGNAL MODES ASSIGNS DATA STATIONS’S ATTRIBUTES INCLUDING OEPRATION MODE, DIAL MODE, TENANT NUMBER, AND METERING GROUPASSIGNS DATA STATION HUNT GROUPS AND MEMBERSASSIGNS DATA STATION HOT LINE SERVICE
Programming Data Interface Unit (DIU) Associated with CS-lO/CS-20.ALLOWS DIU ASSOCIATED WITH CS-10 OR CS-20 TO ESTABLlSH DATA CALLS AND PROVIDE SAME OPERATION AS CSD WITH DATA TERMINAL ADAPTER (DTA). 1.ASSIGN CS-10 OR CS-20 AS VOICE STATION ASSOCIATED WITH DIU WITH CMC-220: @EQUIPMENT NUMBER OF DATA STATION (Pl). DIRECTORY NUMBER OF DATA STATION (P2). DATA TERMINAL TYPE (P3) - (2 = DIU AND CS-lO/CS-20) 0DIRECTORY NUMBER OF VOICE STATION (P4) 2.ASSIGN DATA CALL BUTTON TO CS-20 OR CS-20 ASSOCIATED WITH DIU WITH CMC-203:. STATION DIRECTORY NUMBER (Pl). BUTTON NUMBER (P2) . . FEATURE NUMBER (P3) - (185 = DATA CALL FEATURE NUMBER) SUPPLEMENTARY DATA (P4) - (BLANK). LINE TERMINATING TYPE (P5) - (BLANK). RINGING MODE (P6) - (BLANK) 5.90CMC = 220 PI: 031 P4: 212 P2: 4702 P3: 2CMC = 203 Pl: 212 P4: P2: 4P5:P3: 185 P8:
Programming Data Inrface Unit (DIU) Associated with CSl CATEGORY. DATA STATION ASSIGNMENT @ EKT BUTTON ASSIGNMENT CMC TABLE CMC-220 CMC-203 5.91 FUNCTION INSTALLS OR REMOVES DIU WITH CS-20/C&20 AS VOICE/DATA STATION WITH ITS ASSOCIATED DIRECTORY NUMBERS ASSIGNS DATA CALL BUTTON TO CS-10 OR CS-20 TELEPHONE ASSOCIATED WITH DIU
Programming Key FeKEY TELEPHONE EKT BUTTON ARRANGEMENT FORWARDSAVE/FORWARDSAVE/LINE 1CAMP ONALLREPEATICMLINE 1CAMP ONALLREPEATICM DDD[IDnDDDDDO NOT CALL CALLSPEAKER-DISTURBANNOUNCESPEAKERTRANSFERHOLDANNOUNCEMUTEPHONETRANSFERHOLD DDDDDDDanD CS-10 BUTTON ASSIGNMENTS FOR TELEPHONES CS-20 BUTTON ASSIGNMENTS FOR TELEPHONES CONNECTED TO CARD SLOTS OTHER THAN 01CONNECTED TO CARD SLOTS OTHER THAN 01TRUNK FORWARDSAVE/LINE 1(IN)ALLREPEAT ICM DDDDDDO NOT CALL DISTURBANNOUNCE SPEAKERTRANSFERHOLD DDIIDDTRUNK FORWARDSAVE/LINE 1(IN)ALLREPEATICM II-DDDIICALLSPEAKER- ANNOUNCEMUTEPHONETRANSFER HOLD IDDID CS-10 BUTTON ASSIGNMENTS FOR TELEPHONESCS-20 BUTTON ASSIGNMENTS FOR TELEPHONES CONNECTED TO CARD SLOT 01 CONNECTED TO CARD SLOT 01 NOTE: TELEPHONES CONNECTED TO CARD SLOT 01 WILL RING ON ALL INCOMING CALLS (ANSWERING STATION).5.93
Laboratory Activity - Package tasePART 1: ATTENDANT CONSOLEn (5.3) 1.TEST THE FOLLOWING ATTENDANT CONSOLE FEATURE BUTTONS (USING ATTENDANT CONSOLE USER’S GUIDE FOR REFERENCE): A. COS/CORB. TRUNK CAMP-ON C. EKT STATION PAGING D. MESSAGE LEAVING E. ACCOUNT CODE ENTRY 2.USE CMC-231 TO PERFORM THE FOLLOWING TASKS: A.IDENTIFY THE DEFAULT FEATURE ASSIGNED TO BUTTON 14 OF THE ATTENDANT CONSOLE. B.REMOVE THE FEATURE FROM IBUTTON 14 AND ASSIGN THE FDC PROGRAM FEATURE (WHICH WILL BE USED FOR HOTEL/MOTEL TASKS LATER IN THIS LABORATORY ACTIVITY). 3.USE CMC-233 TO ASSIGN ATTENDANT CONSOLE PRlORlTlES FOR INCOMING CALL TERMINATION. ASSIGN LOW PRIORITY TO THE LOOP TIE TRUNK LINES AND HIGH PRIORITY TO THE E&M TIE TRUNK LINES. TEST THESE INCOMING CALL TERMINATION ASSIGNMENTS BY CALLING FROM TWO OF THE OTHER SYSTEMS, TO CONFIRM THAT ATTENDANT CONSOLE SELECTS PRIORITY BASED ON TRUNK GROUP. 4.USE CMC-306 TO COMPLETE THE FOLLOWING STEPS ASSOCIATED WITH CREATING AN ATTENDANT CONSOLE OVERFLOW STATION. A.CREATE A NIGHT ANSWER GROUP FOR THE ATTENDANT CONSOLE OVERFLOW STATION (PI = 1). B.IDENTIFY NIGHT ANSWER GROUP AS A STATION (P2 = 1) C.IDENTIFY THE EQUIPMENT NUMBER OF THE CS-20 STATION DESIGNATED TO SERVE AS THE ATTENDANT CONSOLE OVERFLOW STATION (P3 = 016), THEN ENTER THE ABOVE PARAMETER VALUES WITH THE ADD/CHANGE FUNCTION KEY. D.CONTINUE TO USE CMC-306 TO ASSIGN ALL TENANTS TO THE NIGHT ANSWER GROUP JUST CREATED BY DESIGNATING THE FOLLOWING VALUES: Pi = 1, P2 = 3 (INDICATING TENANT), AND P3 = * (INDICATING ALL TENANTS). ENTER THESE PARAMETER VALUES WITH THE ADD/CHANGE FUNCTION KEY. E.TEST THE OVERFLOW ASSIGNMENT BY ACTIVATING THE ATTENDANT CONSOLE’S ‘POSITION BUSY’ FEATURE BUTTON.PLACE AN INCOMING CALL TO THE SYSTEM TO DEMONSTRATE THAT THE OVERFLOW STATION NOW RECEIVED THE CALLS INTENDED FOR THE ATTENDANT CONSOLE. 5.94
Laboratory Activity - Package C Data Base Adminstation (5.3) (Continued) PART 2: HOTEL/MOTEL 1.USE CMC-203 TO ASSIGN THE CSD TELEPHONE (EQUIPMENT NUMBER 000) AS THE FRONT DESK CONSOLE.d 2.USE CMC-204 TO SET FLAG WHICH WILL ASSIGN ALL LABORATORY ‘STATIONS (EXCEPT PREVIOUSLY DESIGNATED CSDIFDC) AS GUEST ROOMS. 3.USE CMC-354 TO ASSIGN THE BLF/DSS MODULE (EQUIPMENT NUMBER 015) AS A ROOM STATUS INDICATOR MODULE. 4.USE CMC-355TO ASSIGN HOTEL/MOTEL ROOMS (STATION DIRECTORY NUMBERS) TO BUTTONS ON THE ROOM STATUS INDICATOR MODULE. 5.USE CMC-356 TO ASSOCIATE THE HOTEL/MOTEL PRINTER WITH A 4CHT CIRCUIT (EQUIPMENT NUMBER 090) AND A DIU DIRECTORY NUMBER (202). 6.ASSIGN THE HOTEL/MOTEL PRINTOUT MESSAGE ALLOCATION WITH CMC-357, USING THE FOLLOWING PARAMETER VALUES:INDEPENDENT MESSAGES - Pl = 1P2 = 1 (INDICATING INDEPENDENT MESSAGES) P3 = 01 (TAKING MESSAGES FROM THE ATTENDANT CONSOLE) COMMON MESSAGES - PI = 1P2 = 2 (INDICATING COMMON MESSAGES) P3 = BLANK 7.USE CMC-350 TO ASSIGN THE MESSAGE REGISTRATION TRUNK GROUP NUMBER. MAKE ALL CO TRUNKS (TGN 13) SUBJECT TO HOTEL/MOTEL MESSAGE REGISTRATION. 8.USE CMC-351 TO ASSIGN MESSAGE REGISTRATION BILLING RATE NUMBER 1 TO THE FOLLOWING OFFICE CODES: 227, 476, AND 892. 5.95
Laboratory Acti- PackageC instrantinued) 9.USE CMC-352 TO ASSIGN THE FOLLOWING BILLING RATES FOR BILLING RATE NUMBER 1: INITIAL TIME FOR TELEPHONE CALL (P2) = 20 SECONDS INITIAL CHARGE FOR TELEPHONE CALL (P3) = 50 CENTS ADDITIONAL TIME FOR TELEPHONE CALL (P4) = 60 SECONDS ADDITIONAL CHARGE FOR TELEPHONE CALL (P5) = 30 CENTS 10.USE CMC-100 TO CREATE NEW ACCESS CODES FOR THE FOLLOWING HOTEL/MOTEL CODES: FNO 73 -GUEST ROOM CLEAN-UP FNO 78 -WAKE-UP REGISTRATION FNO 79- WAKE-UP CANCELLATION FNO 96 - SERVICE CALL ROUTING #IFNO 97 - SERVICE CALL ROUTING #2 FNO 98- SERVICE CALL ROUTING #3ENSURE THAT NEW CODES DO NOT CONFLICT WITH EXISTING SYSTEM ACCESS CODES. 11.USE CMC-353 TO ASSIGN SERVICE CODE DESTINATIONS TO THE SERVICE CALL FEATURE ACCESS CODES (PREVIOUSLYASSIGNED). ASSIGN THE FOLLOWING PARAMETER VALUES: Pl = (USE ACCESS CODES ASSIGNED TO FNO 96,97, AND 98) P2 = 1 (INDICATING SPECIAL SERVICE) P3 = 200 (DESTINATION DIRECTORY NUMBER) P4 = BLANK 5.96