Laboratory Activity - System-Wide Programming Changes (Continued) WORK ORDER #2.7 COMPANY NAME: NU SYSTEM CO. PHONE #: (703) 5551212 LOCATION: RESTON, VIRGINIA WORK ORDER #2.7 (TASK #4) DRlGlNATOR: TELECOMMUNICATIONS MANAGER TASKS: l Modify a system timing parameter with CMC-103. (1) Change the timing value for “call park recall” (1) Perform programming change for system-wide to l/2 minute. (Note: current multiplier is set at 61, yielding a default timing value of 62.464. A multiplier of 88 will provide a timing value of (2) Check/test the operation of changes after 91 .112 seconds, or appropriately a minute and completion of this portion of the laboratory a half). (2) Change the timing value for “no answer recall” (3) Proceed to next work order task. timing to approximately 45 seconds. 2.146
Laboratory Activity - Systizm-Wide Programming Changes (Continued) GTE OMNn SBCS WORK ORDER #2.7 ZOMPANY NAME: NU SYSTEM CO. PHONE #: (703) 555-1212 -0CATION: RESTON, VIRGINIA WORK ORDER #2.7 (TASK #5) IRlGlNATOR: TELECOMMUNICATIONS MANAGER TASKS: l Modify the default network PAD circuit values with CMC-106. ‘ARAMETERS: INSTRUCTIONS: (1) Reduce the PAD value for outgoing station dial (1) tone with the following parameters: Perform programming change for system-wide function. Incoming route = 1 (dial tone and recall dial tone) Outgoing route = 6 (station) Value of padding circuit = 6 (-8.5 db) (2) Check/test the operation of changes after completion of this portion of the laboratory activity. (3) Complete review exercise questions l-1 3. (2) After inspection by instructor, restore the PAD value modified above to its default value. . VERIFY THAT ALL PROGRAMMING CHANGES REQUESTED IN WORK ORDERS HAVE BEEN PERFORMED CORRECTLY. 0 ASK INSTRUCTOR TO INSPECT SYSTEM-WIDE PROGRAMMING CHANGES AND INITIAL YOUR PERFORMANCE CHECKLIST. 2.147
Review Exercise - System-Wide Programming Changes (2.7) INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL IN THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E., STUDENT WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 1. THE DEFAULT FEATURE NUMBER (FNO) FOR GROUP PICKUP IS AND DEFAULT FEATURE ACCESS CODE IS . 2. FEATURE ACCESS CODES MAY BE COMPOSED OF A MAXIMUM OF DIGITS, WITH THE SYMBOLS AND USED AS WELL. 3. WHEN WOULD YOU SPECIFY THE NUMBER OF ACCESS CODE DIGITS TO BE SENT IF USING CMC-1 OO? 4. THE EKT PAGING ACCESS CODE CAN TAKE ADDITIONAL DIGIT AND IDENTIFIES: 5. NAME THREE OF THE SYSTEM FLAGS WHICH CAN BE SET WITH CMC-101: , and . 6. WHAT IS THE DEFAULT SETTING FOR CMC-101, FLAG 4, PARAMETER 2? 7. WHAT VALUE WOULD YOU ASSIGN TO FLAG 1 FOR CMC-102, TO INDICATE THAT TENANTS WILL BE SHARING OUTGOING TRUNKS? 2.149
Review Exercise - System-Wide Programming Changes (2,7) (Continued) 8. HOW IS TIMING CALCULATED FOR SYSTEM TIMING VALUES? 9. WHAT MULTIPLIER VALUE WOULD YOU USE TO CHANGE THE CALL ANNOUNCE WARNING BURST TO ONE SECOND? IO. WHAT MULTIPLIER VALUE WOULD YOU USE TO CHANGE THE DSS CAMP-ON RECALL TIMING TO 1% MINUTES? 11. WHEN MIGHT IT BE NECESSARY TO CHANGE THE DEFAULT PAD CIRCUIT VALUES? 12. STATION USERS HAVE COMPLAINED THAT THE BUSY TONE IS TOO LOUD. WHAT PARAMETERS NEED CHANGING WITH CMC-106 TO CORRECT THIS PROBLEM? Pl = P2 = P3 = 13. MATCH EACH OF THE FOLLOWING CMC COMMANDS WITH ITS CORRECT DEFINITION: CMC-100 A. SERVICE PARAMETER ASSIGNMENT CMC-101 B. NETWORK LOSS PLAN ASSIGNMENT CMC-102 C. SYSTEM TIMING PARAMETER ASSIGNMENT CMC-103 D. FEATURE ACCESS CODE NUMBER PLAN ASSIGNMENT CMC-106 E. SYSTEM PARAMETER ASSIGNMENT 2.150
DATA BASE ADMINISTRATION Programming Station Message Detail Recorder 2.152
2.8 Emablinq Obiective GIVEN: . l l 0 0 0 ACTION: . 0 CRITERIA: @ l GTE OMNI SBCS GTE OMNI SBCS Peripherals PORTABLE MAINTENANCE PANEL GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE LABORATORY ACTIVITY - PROGRAMMING STATION MESSAGE DETAIL RECORDER REVIEW EXERCISE USE OMNI SBCS PROGRAMMING TOOLS AND EQUIPMENT TO: - INSTALL STATION MESSAGE DETAIL RECORDER AND ASSIGN CALL SCREENING OPTIONS. COMPLETE REVIEW EXERCISE. DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE WITH PRO- CEDURES OUTLINES IN GTEP MANUAL AND OMNI SBCS STUDENT WORKBOOK REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN AC@ DANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING ORGANIZATION. 2.153
- Programming Station Message Detail Recorder/SM creening GTE OMN~ SBCS 1 DESCRIPTION 1 l PROVIDES LOCAL PRINTOUT OF SYSTEM CALL INFORMATION. . IF SMDR OPTION IS INSTALLED THE FOLLOWING INFORMATION IS RECORDED FOR EVERY CALL: - TIME OF CALL ORIGINATION - CALL DURATION RECORDED IN HOURS, MINUTES, AND SECONDS - ORIGINATING STATION NUMBER - TRUNK NUMBER WITH IDENTIFICATION - CALLING PARTY IDENTIFICATION - TRUNK ACCESS CODE - DIRECTORY NUMBER DIALED AND PERSONAL ACCOUNTING CODE (SVR 1.5.X.X) - ACCOUNT CODE - TENANT NUMBER (FOR MULTI-TENANT APPLICATION) - METERING GROUP NUMBER l AUTOMATIC SCREENING OPERATION l OPTIONAL CALL SCREENING OPTIONS: - OUTGOING CALLS THROUGH CO TRUNK LINES - OUTGOING CALLS THROUGH TIE TRUNK LINES - ACCOUNT CODE CALLS - TOLL CALLS - OVERTIME CALLS - TRUNK GROUP SELECTION - CLASS OF RESTRICTION SELECTION - TENANT SELECTION e CALLS LASTING LESS THAN PROGRAMMED DATA BASE THRESHOLD TIME ARE NOT RECORDED IN ORDER TO EXCLUDE INCOMPLETE CALLS (E.G., TERMINATED TO BUSY TONE, REORDER TONE, OR NO ANSWER) FROM CALL RECORD. 2.154
1 PROCEDURE * 1 1. USE CMC-500 TO ASSIGN SMDR OUTPUT OPTIONS ON OUTGOING CONNECTION: . CO OUTGOING CONNECTION (PI) CMC=500 . TIE LINE OUTGOING CONNECTION (P2) n PI: 1 P4: 1 . ACCOUNT FLAG (P3) P2: 0 . TOLL CALL FLAG (P4) P3: 0 2. USE CMC-501 TO ASSIGN TRUNK GROUPS FOR SMDR OUTPUT: CMC=501 I I Pl: 13 . TRUNK GROUP NUMBER (PI)** P2: 1 . OUTPUT IDENTIFICATION FLAG (P2) 3. USE CMC-502 TO ASSIGN COR FOR StiDR OUTPUT: . CLASS OF RESTRICTION (PI) . OUTPUT IDENTIFICATION FLAG (P2) 4. USE CMC-503 TO ASSIGN SMDR OUTPUT FOR TENANTS: . TENANT NUMBER (PI) . OUTPUT IDENTIFICATION FLAG (P2) CMC=503 I I PI: 2 P2: 1 5. USE CMC-504 TO SET MINIMUM CALL DURATION FOR SMDR OUTPUT: . HOURS FOR MINIMUM CALL DURATION (PI) CMC=504 . MINUTES FOR MINIMUM CALL DURATION (P2) Pl: 0 0 SECONDS FOR MINIMUM CALL DURATION (P3j rl P2: 0 P3: 45 NOTE: REFER TO MODULE Ill FOR SMDR MAINTENANCE COMMANDS (CMC 705 AND 901) * ASSUMES PHYSICAL INSTALLATION OF SERIAL PRINTER. ** REFER TO DATA BASE PROGRAMMING SECTION IN OMNI SBCS GTEP MANUAL FOR LISTING OF TRUNK GROUP NUMBERS. 2.155