Home > GTE > Communications System > GTE Omni Scbs Installation And Maintenance Manual

GTE Omni Scbs Installation And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GTE Omni Scbs Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 656
    							RUN LAMP (GREEN): 
    . INDICATES NORMAL ON CONDITION. 
    . IF OUT, A MAJOR ALARM CONDITION IS INDICATED 
    (DISPLAYED AT REMOTE LOCATION) CAUSED BY ONE OF 
    FOLLOWING CONDITIONS: 
    - POWER OUTAGE, 
    - DEFECTIVE CPM OR SWC OSCILLATING CIRCUIT, OR 
    - SIXTEENTH FAILURE TO RESTART SYSTEM VIA WATCH- 
    DOG TIMER. 
    . 6PFT CARD AUTOMATICALLY SWITCHES ITS CIRCUITS TO 
    POWER FAILURE TRANSFER MODE. 
    ALARM LAMP (RED): 
    @ INDICATES A MINOR ALARM CONDITION (REMOTE 
    LOCATION) BECAUSE SOFTWARE HAS DETECTED A 
    FAILURE IN ONE OR MORE SYSTEM AREAS. 
    0 FAULT LOG (CMC-801) LISTS MORE DETAILED 
    INFORMATION ON CAUSES OF FAILURE. 
    THblE OVERFLOW (TO) LAMP (RED): 
    0 INDICATES WATCH-DOG TIMER HAS DETECTED A FAILURE 
    IN CPM CARD OR OPERATING PROGRAM. 
    0 SYSTEM AUTOMATICALLY ATTEMPTS RESTART AND IF 
    SUCCESSFUL, LOGS FAULT IN FAULT LOG. 
    0 AFTER 16 UNSUCCESSFUL RETRIES, RUN LAMP IS TURNED 
    OFF. TO LAMP MUST BE TURNED OFF BY COLD OR HOT 
    RESTART, OR BY READING FAULT LOG. 
    - RUN (GREEN) 
    T- ALM (RED) 
    UP-COLD RESTART 
    CAUTION 
    REESTABLISHES DEFAULT 
    DATA BASE. ODDB IS LOST - TO (RED) 
    CENTER- 
    RESET MOMENTARY 
    INTERRUPT 
    DOWN- 
    HOT RESTART 
    - RESTART BUTTON 
    3.10  
    						
    							Remote Alarm Stat 
    CUSTOMER PROVIDED ALARMS AT REMOTE LOCATIONS CAN INDICATE 
    ONE OF TWO ALARM STATES: 
    MAJOR ALARM - 
    . SYSTEM POWER IS OFF AND SYSTEM IS IN POWER FAILURE TRANSFER 
    MODE. 
    MINOR ALARM - 
    . SYSTEM HAS FAILURE IN ONE OR MORE AREAS OF OPERATION. 
    IF BOTH ALARMS ARE ON, THE SYSTEM HAS DETECTED A SYSTEM-WIDE 
    PROBLEM. 
    3.11  
    						
    							PROGRAMMED ALAlwl BUTTON ON BLF/lxS (OR OTHER DESIGNATED 
    MT INSTRUMENT) lNDKATES A MINOR ALARM CONDITION. 
    LOCATION OF PROBLEIM A D FAULT LOG LISTING CAN BE OBTAINED 
    THROUGH USE OF PIMP OR IVET WITH CIVIC-800 AND 801. 
    3.12  
    						
    							Visual Alarms Sche 
    r f 
    I 
    SWC CARD CPM CARD PFT CARD 
    SWC CLOCK FAILURE 
    RESET SET 
    FLIP 
    RESET FLOP 
    MANUAL 
    RESTART 
    I 
    ALM 
    ml 
    RA ALM 
    (RED) 
    + 
    +I 
    MODEM 
    REMOTE 
    MAINTENANCE 
    CENTER PORTABLE 
    MAINTENANCE POWER 
    SUPPLY 
    rl 
    0 X 
    (GREEN) 
    RELAYS 
    RA AND ALM 
    ACTIVATED 
    REMOTE ALARM 
    L----------------------~ 
    (CUSTOMER-PROVIDED)  
    						
    							Review Exercise 
    - 
    ntena 
    ve 
    INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL IN 
    THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E., STUDENT WORK- 
    BOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO 
    IINSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 
    1. THE TOOLS REQUIRED FOR SYSTEM DATA BASE MAINTENANCE ARE 
    AND 
    2. REMOTE MAINTENANCE USING A PORTABLE MAINTENANCE PANEL REQUIRES 
    AT BOTH THE REMOTE SITE AND AT THE OMNI SBCS SITE. 
    3. LIST THREE PREVENTIVE MAINTENANCE PROCEDURES RELATED TO PROPER CARE OF PCB 
    CARDS: 
    (4 
    4. THE THREE PRIMARY VISUAL INDICATORS OF SYSTEM STATUS ARE: 
    A. CPM LED LAMPS, CABLE WARNING SYSTEM, AND MAJOR AND MINOR ALARMS AT REMOTE 
    LOCATION. 
    B. ALARM BUTTON ON SINGLE LINE TELEPHONE, MAJOR AND MINOR ALARMS AT REMOTE 
    LOCATION, AND SYSTEM FAULT LOG. 
    C. POWER ON LAMP, CPM LED LAMPS, AND POWER FAIL TRANSFER ALARM. 
    D. CPM LED LAMPS, MAJOR AND MINOR ALARMS AT REMOTE LOCATIONS, AND ALARM 
    BUTTON ON BLF/DSS OR EKT INSTRUMENTS. 
    5. HOW COULD MORE DETAILED INFORMATION BE FOUND ABOUT MINOR ALARM CONDITION OR 
    WATCHDOG TIMER OVERFLOW? 
    3.14  
    						
    							Review Exercise - 
    Maintenance Overview (3.1) (Cantinwed) 
    6. WHAT MAY BE INDICATED IF THE RUN LAMP IS OFF AND A MAJOR ALARM CONDITION EXISTS? 
    7. 
    8. 
    9. 
    10. HOW IS THE TIMER OVERFLOW LAMP RESET (TURNED OFF)?! 
    THE SYSTEM WILL AUTOMATICALLY ATTEMPT TO RESTART THE SYSTEM TIMES, 
    IN THE EVENT OF A WATCHDOG TIMER OVERFLOW. 
    WHAT SYSTEM ALARM STATES CAN BE INDICATED BY A CUSTOMER-PROVIDED ALARM AT A 
    REMOTE LOCATION? 
    WHAT CMC COMMAND IS USED TO PROGRAM AN ALARM BUTTON ON A BLF/DSS INSTRUMENT? 
    3.15  
    						
    							-.. ,- .., 
    mmands 
    3.16  
    						
    							GIVEN: l 
    e 
    l 
    l 
    0 
    l 
    ACTION: e 
    0 
    l 
    CRITERIA: e 
    8 
    GTE OMNI SBCS 
    PORTABLE MAINTENANCE PANEL 
    GTE OMNI SBCS PERIPHERALS 
    GTE OMNI SBCS COURSE AND SITE 
    DOCUMENTATION PACKAGE 
    LABORATORY ACTIVITY 
    REVIEW EXERCISE 
    IDENTIFY FUNCTIONS AND APPLICATIONS OF CMC 
    MAINTENANCE COMMANDS. 
    MODIFY PARAMETER VALUES FOR CMC MAINTENANCE 
    COMMANDS. 
    COMPLETE REVIEW EXERCISE. 
    DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE 
    WITH PROCEDURES OUTLINED IN OMNI SBCS GTEP 
    MANUAL AND OMNI SBCS STUDENT WORKBOOK. 
    REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN 
    ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS 
    TRAINING ORGANIZATION. 
    3.17  
    						
    							[DESCRIPTION 1 
    8 SETS THE SYSTEM HARDWARE AND SOFTWARE CLOCKS. 
    @ TIME AND DATE ARE DISPLAYED ON ALL EKT LCD DlSPLAYS. 
    @ CLOCK MUST BE RESET FOLLOWING COLD RESTART. 
    [PROCEDURE 1 
    1. USE CMC-700 TO SET CURRENT CLOCK AND DATE PARAMETERS*: 
    . YEAR (PI) 
    Q MONTH AND DAY (P2) 
    8 DAY OF THE WEEK (P3) 
    . HOUR AND MINUTE (P4) 
    Pl: 1986 P4: 0936 
    *SYSTEM WILL NOT ACCEPT ERRONEOUS VALUES SUCH AS DAY 43. 
    NOTE: 
    HARD ERR ERROR MESSAGE INDICATES THAT CPM CARD MAY 
    NEED REPLACEMENT. 
    3.18  
    						
    							Circuit Busy Assignment 
    1 DESCRIPTION 1 
    @ ALLOWS CIRCUITS FOR TRUNKS AND INSTRUMENTS TO BE PUT OUT OF 
    SERVICE (MADE BUSY) WHILE MAINTENANCE PROCEDURES ARE BEING 
    PERFORMED. 
    . SAME COMMAND IS USED TO RESTORE SERVICE TO CIRCUIT. 
    1 PROCEDURE 1 
    1. USE CMC-701 TO BUSY OUT A CIRCUIT OR RETURN CIRCUIT TO SERVICE. 
    . EQUIPMENT NUMBER (PI) 
    . MAKE BUSY OR PUT IN SEVICE FLAG (P2) 
    CMC=701 
    r-l 
    Pl: 162 
    P2: 1 
    *SYSTEM WILL DENY ANY ATTEMPT TO MAKE THE MASTER CONTROL 
    TELEPHONE’S CIRCUIT BUSY. 
    NOTE: SMDR PRINTER CIRCUIT IS MADE BUSY WITH CMC-705. 
    3.19  
    						
    All GTE manuals Comments (0)