    							Fault Code Translation (Continued) 
    Gull OMNi SBGS 
    CIVIC-801 : 
    FAULT DATA TRANSLATION 
    1. FAULT DATA IN HEX CODE: 
    HH HH HH HH HH HH HH 
    1 234567 
    H: HEX CHARACTER O-9, A TO F OR BLANK 
    2. SCI STATUS 
    EACH BIT SHOWS THE FOLLOWING MEANING: 
    BBBBBBBB 
    l- 
    L 
    !: L 
    TRANSMITTER READY 
    RECEIVER READY 
    TRANSMITTER EMPTY 
    PARITY ERROR 
    OVER-RUN ERROR 
    FRAMING ERROR 
    BREAK DETECT 
    DATA SET READY 
    3.28  
    						
    							DESCRIPTION 
    0 PLACE SMDR PRINTER OUT OF SERVICE WITH CMC-705 WHEN CHANGING 
    PAPER. ENSURE THAT CORRECT RS-232-C PORT IS ENTERED. 
    0 CHANGE THE CONTROL CONDITION FOR THE MDR PRINTER REQUIREMENTS 
    RELATING TO PAUSE TRANSMISSION CHARACTER, POWER CONTROL AND 
    TIMING, OR PRINTOUT FORMAT 
    pGGEGG-*I 
    1. PLACE PRINTER IN OR OUT OF SERVICE WITH CMC-705: CMC=705 
    0 PORT NUMBER (PI) P1:l 
    P2:l 
    0 IN/OUT OF SERVICE FLAG (P2) 
    2. MODIFY PRINTER CONTROLS WITH CMC-901: .I 
    0 PORT NUMBER (PI) 
    0 PAUSE TRANSMISSION (XOFFIXON) CHARACTER (P2) 
    CMC=901 
    0 POWER CONTROL (P3) P1:l P4: 
    cl 
    P2:l P5: 
    0 POWER ON TIMING (P5) P3: P6:l 
    0 POWER OFF TIMING (P6) 
    * REFER TO OMNI SBCS GTEP MANUAL, MAINTENANCE SECTION, FOR 
    DESCRIPTION OF ASCII &-ON/X-OFF AND POWER CONTROL CHARACTERS. 
    3.29  
    						
    							RS-232-C Port Configuration Assignkent 
    GE awvll sms 
    DESCRIPTION 
    . ASSIGN OR MODIFY THE CHARACTERISTICS OF THE TWO RS-232-C PORTS 
    INCLUDING BIT RATE, PARITY, CHARACTER LENGTH, STOP BIT AND ECHO. 
    . BOTH PORTS ARE FULL DUPLEX. 
    . DEFAULT STANDARD DATA BASE PRESENTS PORT jif FOR PMP AND PORT 1 FOR 
    MDR PRINTER. 
    piizGiq 
    1. USE CMC-900 TO SET RS-232-C PORT CHARACTERISTICS: 
    . PORT (PI) 
    . BIT RATE (P2) 
    . PARITY (P3) 
    l CHARACTER LENGTH (P4) 
    . STOP BIT (P5) 
    . ECHO BACK (P6) 
    NOTE: IF PORT TO BE CHANGED IS ASSIGNED TO SMDR PRINTER, FIRST PLACE 
    PRINTER OUT OF SERVICE WITH CMC-705. 
    3.30  
    						
    							Diagnostic Trunk Connection Assignment 
    j-J 
    0 CMC-802 DED‘iCATES A TRUNK TO A DESIGNATED STATION FOR AUDITORY, 
    RINGING, AND TRANSMISSION VERIFICATION. 
    @ AFTER ASSIGNMENT, TESTS CAN BE MADE BY ORIGINATING A CALL TO THE 
    TRUNK BY DIALING THE TRUNK ACCESS CODE FOR THE TRUNK GROUP. 
    @ WORKING TRUNK CAN BE CONFIRMED BY DIALING AN OUTSIDE DIRECTORY 
    NUMBER AND LISTENING FOR CONFIRMATION CALL PROGRESS TONES. 
    1 PROCEDURE +[ 
    I 
    I 
    1. USE CMC-802 TO ENTER STATION DIRECTORY NUMBER AND TRUNK 
    TO BE TESTED: 
    CMC=802 
    l DIRECTORY NUMBER (PI) 
    l TRUNK EQUIPMENT NUMBER (P2) 
    r-l 
    P1:214 
    P2:181 
    NOTE: WHEN ACTlVATED STATION WILL ALWAYS SEIZE ASSIGNED TRUNK 
    UNTIL VALUES FOR PI AND P2 ARE DELETED WITH 
    REMOVE KEY. 
    3.31  
    						
    							. . . ,.- 
    c Measuremen 
    DESCRIPTION GE OMNI slxs 
    . ASSIGN OR CANCEL TRUNK GROUP NUMBERS TO BE SAMPLED WlTH CMC-600. 
    . 
    ACTIVATE A TRAFFIC MEASUREMENT STUDY WITH CMC-601. 
    @ 
    DEFINE THE DISPLAY FOR TRAFFIC MEASUREMENT BASED ON RECENT DATA 
    (LESS THAN IO HOURS) OR OLDER DATA (AFTER 10 HOURS). 
    . 
    TRAFFIC DENSITY PERCENTAGE IS DISPLAYED BASED ON DESIGNATED TRUNK 
    GROUP NUMBERS. 
    (PROCEDURE1 
    CMC=600 
    Pl:l 
    1. ASSIGN TRUNK GROUP NUMBERS TO BE SAMPLED WITH CMC-600: P2:13 
    . REGISTRATION SEQUENCE NUMBER: (PI) 
    . TRUNK GROUP NUMBER (P2) 1 
    2. USE CMC-601 TO ACTIVATE TRAFFIC MEASUREMENT FLAG: 
    @ TRAFFIC MEASUREMENT START/STOP FLAG (PI) 
    CMC=601 
    3. USE CMC-602 TO DISPLAY TRAFFIC MEASUREMENT DATA: 
    . TRAFFIC MEASUREMENT DATA AREA (PI) 
    . REGISTRATION SEQUENCE NUMBER (P2) El Pi:1 
    @ TRUNK GROUP NUMBER (P3) 
    . ELAPSED TIME IN HOURS (P4) 
    CMC=602 
    . TRAFFIC DENSITY (P5) P1:2 P4:l 
    NOTE: TRUNK GROUP NUMBERS MUST BE DELETED FROM SAMPLE 
    WITH- 
    REMOVE KEY AFTER TRAFFIC STUDY HAS BEENd 
    El 
    P2:l P5:O 
    P3:13 
    DEACTIVACTIVATED (CMC-601). 3.32  
    						
    							aintenance 
    Comman 
    Gull 
    TRUNK GROUP TRAFFIC 
    SCREENING ASSIGNMENT 
    TRAFFIC MEASUREMENT 
    ACTIVATION 
    TRAFFIC MEASUREMENT 
    DATA DISPLAY 
    TIME AND DATE SETTING 
    CIRCUIT BUSY 
    ASSIGNMENT 
    SMDR IN/OUT OF SERVICE 600 ASSIGNS TRUNK GROUP NUMBERS TO 
    TRAFFIC SAMPLE. 
    601 ACTIVATES TRAFFIC MEASUREMENT 
    STUDY. 
    602 DISPLAYS TRAFFIC DENSITY. 
    700 
    701 
    705 SETS SYSTEM HARDWARE AND 
    SOFTWARE CLOCK. 
    PLACES CIRCUITS IN/OUT OF SERVICE 
    FOR MAINTENANCE. 
    PLACES SMDR IN/OUT OF SERVICE FOR 
    MAINTENANCE. 
    3.33  
    						
    							c-. Maintenance Data Base Commands/ 
    CM6 Command Summary (Continued) 
    Gull awvn ~Bcs 
    0 
    0 
    e 
    e 
    0 
    e 
    0 DEVICE STATUS 800 LISTS FAULTY DEVICES AND LOCATIONS. 
    FAULT LOG 
    801 
    DIAGNOSTIC TRUNK 
    CONNECTION 
    ASSIGNMENT 
    RS-232-C PORT 
    CONFIGURATION 
    SMDR PRINTER CONTROL 
    READ OUT SYSTEM 
    SOFTWARE VERSION ID 
    DISPLAY 
    DISTRIBUTED 
    PROCESSOR VERSION ID 
    DISPLAY 802 
    900 
    901 
    904 
    907 PROVIDES DETAILED FAULT 
    INFORMATION FOR TROUBLESHOOTING. 
    ASSIGNS A STATION TO A TRUNK FOR 
    DIAGNOSTIC VERIFICATION. 
    CHANGES CHARACTERISTICS OF RS-232-C 
    PORTS. 
    CHANGES CONTROL CONDITION FOR 
    SMDR. 
    DISPLAYS CURRENT SOFTWARE 
    RELEASE. 
    DISPLAYS VERSION NUMBER FOR ICG 
    CARDS. 
    3.34  
    						
    							PERFORM THE FOLLOWING PROGRAMMING TASKS IN THE SEQUENCE OUTLINED BELOW AND IN ACCORDANCE 
    WITH THE GTE OMNI SBCS MANUAL. COMPLETE THE REVIEW EXERCISE QUESTIONS UPON COMPLETION OF THIS 
    LABORATORY ACTIVITY. 
    Labo - Maintenance/Data 
    WORK ORDER #3.2 
    ZOMPANY NAME: NU SYSTEM CO. PHONE #: (703) 555-l 212 
    -0CATION: RESTON, VIRGINIA WORK ORDER 3.2 (TASK #l) 
    IRIGINATOR: TELECOMMUNICATIONS MANAGER 
    TASKS: 0 Set time, day, date with CMC-700. 
    0 Take a circuit out of service with CMC-701. 
    0 Display software and distributed processor 
    version number with CMC-904 and CMC-907. 
    (1) Set system clock using CMS-700. (1) Perform maintenance programming 
    (2) Remove loop tie line circuit. (EN1 60) from commands. 
    service with CMC-701. (2) Check/test the operation of commands after 
    (3) Obtain current software version number with completion of this portion of the laboratory 
    CMC-904 and CMC-907. 
    (3) Proceed with next work order task. I  
    						
    							Laboratory Activity - Maintenance/Data 
    Base Commands (3.2) (Continued) 
    WORK ORDER #3.2 
    ZOMPANY NAME: NU SYSTEM CO. PHONE #: (703) 555-1212 
    .OCATION: RESTON, VIRGINIA WORK ORDER 3.2 (TASK #2) 
    IRIGINATOR: TELECOMMUNICATIONS MANAGER 
    rASKS: 
    l Restore circuit to service with CMC-701. 
    l Display device status with CMC-800. 
    l Display fault log with CMC-801. 
    (1) Restore the loop tie line to service. (1) Perform maintenance programming commands. 
    (2) Unplug one of the CS-10 telephones from its (2) Check/test the operation of commands after 
    modular jack. completion of this portion of the laboratory activity. 
    (3) Check the device status display with CMC-800. (3) Proceed with next work order task. / 
    (4) Read out the latest fault log listing with CMC-801. 
    Was equipment number of disconnected @S-10 
    telelphone displayed? 
    3.37  
    						
    All GTE manuals Comments (0)

    Related Manuals for GTE Omni Scbs Installation And Maintenance Manual