    							Laboratory Activity - Maintenance/Data 
    Base Commands (3.2) (Continued) 
    WORK ORDER #3.2 
    COMPANY NAME: NU SYSTEM CD. 
    -0CATlON: RESTON, VIRGINIA 
    3RlGlNATCR: TELECOMMUNICATIONS MANAGER PHONE #: (703) 5551212 
    WORK ORDER 3.2 (TASK #3) 
    TASKS: 
    l Take SMDR printer out of service with CMC-705. 
    l Modify printer controls with CMC-901. 
    e Change the RS-232-C port configuration 
    assignment with CMC-900. 
    (1) Remove SMDR printer from service ‘with CMC-705. (1) Perform maintenance programming commands. 
    (2) Change SMDR power on character to NUL and (2) Check/test the operation of commands after 
    power off to DEL. Change power on timing to 800 completion of this portion of the laboratory activity. 
    ms and power off timing to 30 seconds. 
    (3) Proceed with next work order task. 
    [3) Modify the RS-232-C configuration for port fi to: 
    - 
    2400 bps 
    - even parity 
    - 7 bit character length 
    - 1 bit stop 
    - 
    no echo 
    (Above dafa terms will be discussed in Module Iv). 
    3.38  
    						
    							- Maintenance/Data 
    3.2) (Continued) 
    GE OMNi azzzs 
    WORK ORDER #3.2 
    :OMPANY NAME: NU SYSTEM CO. PHONE #: (703) 555-1212 
    OCATION: RESTON, VIRGINIA WORK ORDER 3.2 (TASK #4) 
    IRIGINATOR: TELECOMMUNICATIONS MANAGER 
    ASKS: 
    a 
    ’ 0 Restore SMDR printer to service with CMC-705. 
    Assign diagnostic trunk connection wfth CMC-802. 
    e Establish a traffic measurement study wftft CMC- 
    600, CMC-601, and CMC-602. 
    ‘ARAMETERS: 
    (1) 
    (2) 
    (3) 
    (4) 
    (5) 
    03 
    (7) Restore SMDR printer to service. 
    Dedicate the E&M tie line (EN170) to station 
    directory number 212 using CMC-802. Trunk tests 
    will be conducted later in Maintenance, 
    Diagnostics section). 
    Assign CO trunk group 13 to traffic sample 
    (registration sequence number 1) with CMC-600. 
    Activate the traffic measurement study with 
    CMC-601. 
    Place several outgoing Co trunk cafN. 
    Display the traffic measurement data for most 
    recent data with CMC-602. 
    Deactivate the traffic measurement study with 
    CMC-602. 
    Remove CO trunk group (13) from the sample 
    registration sequence number 1 using CMC-600. NSTRUCTIONS: 
    (1) Perform maintenance programming commands. 
    (2) Check/test the operation of commands after 
    completion of this portion of the laboratory activity. 
    (3) Complete Review Exercise questions l-l 5.  
    						
    							--., ,,r 
    Review Exercise - 
    Maintenance/Data Base Commands 
    (3.2) 
    GTE OMNi SBCS 
    INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL IN 
    THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E., STUDENT WORK- 
    BOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO 
    INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 
    1. WHEN MUST THE SYSTEM HARDWARE/SOFTWARE CLOCK BE SET OR RESET? 
    2. (TRUE’ OR FALSE) 
    CIRCUITS FOR ALL SYSTEM EQUIPMENT AND TRUNKS CAN 
    ‘BE TAKEN OUT OF SERVICE WITH CMC-701. 
    3. IDENTIFY THE COMPONENTS OF THE FOLLOWING SOFTWARE VERSION NUMBER (8011.2) 
    4. IDENTIFY THE COMPONENTS OF THE FOLLOWING VERSION NUMBER FOR THE INTERFACE 
    CARD LISTED BELOW: 
    CM@ = 907 
    PI = 180 
    P2 = 2 
    P3 = 0 
    3.40  
    						
    							Review Exercise - 
    5. MATCH THE CORRECT CONTENTS OF THE THREE DEVICE STATUS SCREENS FOR CMC-800: 
    SCREEN ONE A. EKT STATUS 
    SCREEN TWO B. LINE/TRUNK CARD AND RS-232-C 
    SCREEN THREE C. HIGH LEVEL PORT STATUS FAULT SUMMARY 
    6. WHAT CAN BE DONE TO OBTAIN MORE INFORMATION REGARDING A FAULTY DEVICE LISTED 
    WITH CMC-800? 
    CMC= 801 DSP PI: Pl: TRM P4: 015 
    P2: 10:37 03112 P2: 
    P3: 1 P3: 
     ) P4: 
    3.41 - 
    7. IDENTIFY THE FOLLOWING DEVICES LISTED FROM CMC-800: 
    SCI 
    ICG 
    RTS 
    8. IDENTIFY THE INFORMATION LISTED ON THE FOLLOWING FAULT 
    LOG 
    DISPLAYS:  
    						
    							_,--_, 
    .‘. I. 
    ,.‘_ , ,_ ..(I( .” 
    Review Exercise - 
    ntenance/l[)ata Base Commands (3.2) 
    ntinued) 
    CMC= 801 
    Pl: ICG P4: 020 
    P2: lo:38 03112 
    P3: 0 Pl: 
    P2: 
    P3: 
    P4: 
    9. HOW COULD THE POWER OFF TIMING VALUE FOR THE SMDR PRINTER BE CHANGED TO ONE 
    MINUTE? 
    10. THE SLOWEST BIT RATE ACCOMMODATED BY THE RS-232-C PORT CONFIGURATION IS 
    AND THE FASTEST BIT RATE IS 
    11. TRUE OR FALSE 
    STATION ASSIGNED TO TRUNK FOR DIAGNOSTIC TRUNK TESTS 
    WITH CMC-802 WILL ALWAYS SEIZE Tt-iAT PARTICULAR TRUNK CONNECTION. 
    12. WHAT MUST OCCUR BEFORE A TRAFFIC MEASUREMENT STUDY IS ACTIVATED WITH CMC- 
    601? 
    13. TRAFFIC MEASUREMENT DATA CAN BE PROVIDED FOR 
    AND 
    STORED DATA. 
    14. A MAXIMUM OF 
    TRUNK GROUP MEMBERS CAN BE SAMPLED IN A TRAFFIC 
    MEASUREMENT STUDY. 
    3.42  
    						
    							Review Exercise - 
    Maintenance/Data Base Commands 
    (3.2) 
    (Continued) 
    15. 
    CMC-600 
    CMC-601 
    CMC-602 
    CMC-700 
    CMC-701 
    CMC-705 
    CMC-800 
    CMC-801 
    CMC-802 
    CMC-900 
    CMC-901 
    CMC-904 
    CMC-907 A. 
    B. 
    C. 
    D. 
    E. 
    F. 
    G. 
    H. 
    I. 
    J. 
    K. 
    L. 
    M. TRAFFIC TRUNK GROUP SCREENING 
    TIME, DAY, AND DATE SETTING 
    SMDR PRINTER IN/OUT OF SERVICE 
    DEVICE STATUS DISPLAY 
    TRAFFIC MEASUREMENT DATA DISPLAY 
    RS-232-C PORT CONFIGURATION ASSIGNMENT 
    SMDR PRINTER CONTROL 
    CIRCUIT IN/OUT OF SERVICE 
    FAULT LOG DISPLAY 
    DISTRIBUTED PROCESSOR VERSION ID DISPLAY 
    TRAFFIC MEASUREMENT ACTIVATION 
    DIAGNOSTIC TRUNK CONNECTION ASSIGNMENT 
    SYSTEM SOFTWARE VERSION ID DISPLAY 
    3.43  
    						
    							-. 
    . 
    SYSTEM MAINTENANCE 
    Troubleshooting 
    3.44  
    						
    							GIVEN: 0 
    0 
    0 
    0 
    0 
    0 
    l 
    e 
    GTE OMNI SBCS 
    PORTABLE MAINTENANCE PANEL 
    GTE OMNI SBCS PERIPHERALS 
    REPLACEMENT CARDS AND INSTRUMENTS 
    GTE OMNI SBCS COURSE AND SITE DOCUMENTATION 
    PACKAGE 
    STANDARD MAINTENANCE TOOLS 
    LABORATORY ACTIVITY 
    REVIEW EXERCISE 
    ACTION: 
    e 
    0 
    CRITERIA: 0 
    0 
    USE SBCS TROUBLESHOOTING STRATEGIES TO ISOLATE AND 
    RESOLVE TYPICAL SYSTEM HARDWARE AND SOFTWARE 
    PROBLEMS. 
    COMPLETE REVIEW EXERCISE. 
    PROBLEMS WILL BE IDENTIFIED AND RESOLVED IN 
    ACCORDANCE WITH TROUBLESHOOTING PROCEDURES 
    OUTLINED IN OMNI SBCS GTEP MANUAL AND OMNI SBCS 
    STUDENT WORKBOOK. 
    REVIEW EXERCISE WILL BE COMPLETED CORRECTLY IN 
    ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING 
    ORGANIZATION. 
    3.45  
    						
    							Troubleshooting Overview 
    . TROUBLESHOOTING IS A SYSTEMATIC APPROACH TO IDENTIFYING AND 
    ISOLATING SYSTEM PROBLEMS. 
    . PRIMARY TROUBLESHOOTING TOOLS INCLUDE BOTH THE DEVICE STATUS AND 
    FAULT LOG TABLES, IN CONJUNCTION WITH SYSTEM VISUAL INDICATORS. 
    l ISOLATION OF A PROBLEM’S CAUSES REQUIRES: 
    1. DETERMINATION OF SPECIFIC PROBLEMS (E.G., NO RINGING, NO DIAL TONE) 
    2. DETERMINATION OF THE EXTENT OF THE PROBLEM (E.G., A CIRCUIT, A CARD, 
    OR A GROUP NUMBER) 
    . CORRECTION OF A PROBLEM REQUIRES: 
    1. 
    INITIAL CHECKING OF CORRECT SYSTEM OPERATION. 
    2. POSSIBLE REPLACEMENT OF DEFECTIVE COMPONENTS OR RELATED FOLLOW- 
    UP ACTION. 
    3. TESTING TO ENSURE CORRECT MAINTENANCE SYSTEM OPERATION. 
    3.46  
    						
    							ICGO 1 1 t 2 1 3 1 4 1 
    @ A SYSTEM-WIDE PROBLEM lS INDICATED BY A COMPLETE CALL PROCESSlNG FAILURE. 
    . SYSTEM-WIDE PROBLEMS USUALLY ARE CAUSED BY: 
    - A DEFECTIVE POWER SUPPLY OR FAULT IN THE INTERCONNECTING POWER 
    CABLES, OR 
    - A DEFECTIVE COMMON CONTROL GROUP CARD. 
    . IF CAUSE CANNOT BE ISOLATED, THE CABINET BACKPLANE CIRCUITRY MAY BE 
    DEFECTIVE. 
    0 REFER TO THE FOLLOWING THREE FLOWCHARTS FOR TROUBLESHOOTING 
    PROCEDURES FOR SYSTEM-WIDE PROBLEMS. 
    3.47  
    						