    PROCEDURE FOR DETERMINATION OF CAUSE (FLOWCHART 1) 
    IS LAMP LIT? 
    NO 
    COMMERICAL AC POWER 
    r- 
    TURN POWER 
    SWITCH OFF 
    AND ON AGAIN. IS LAMP LIT? VERIFY 
    SYSTEM 
    OPERATION 
    TURN POWER OFF- 
    REMOVE POWER CABLE 
    AT POWER SUPPLY 
    REPLACE AND TURN 
    POWER ON AGAIN. 
    IS LAMP LIT? 
    NO 
    REPLACE POWER CABLE 
    INSTALL NEW POWER 
    SUPPLY AND VERIFY 
    SYSTEM OPERATION 
    1 YES 
    3.48  
    						
    							PROCEDURE FOR DETERMINATION OF CAUSE (FLOWCHART 2) 
    TURN POWER OFF. 
    REMOVE ALL CARDS 
    FROM FLOWCHART 1. (INCLUDING RGEN) FROM 
    ) BACKPLANE CONNECTORS. 
    RECONNECT POWER CABLE 
    AND TURN POWER ON. 
    IS LAMP LIT? NO TURN POWER OFF. 
    ) REPLACE POWER CABLE 
    AND TURN POWER 
    ON. 
    A CARD HAS A FAlliT- 
    REINSERT CARDS ONE AT 
    A TIME TO IDENTIFY 
    DEFECTIVE CARD(S). IS LAMP LIT? TURN POWER OFF. 
    REINSERT ALL 
    CARDS. 
    REPLACE ANY DEFECTIVE 
    CARDS. VERIFY TURN POWER ON. 
    SYSTEM OPERATION. VERIFY SYSTEM 
    OPERATION. 
    RESTORE ODDB 
    THROUGH LOADING 
    OR PROGRAMMING. 
    NOTE: TURN POWER OFF WHEN REINSERTING CPM, SWC, MEM, AND RGEN 
    CARDS. UNSEATING CPM OR MEM CARDS DELETES ODDB.  
    						
    							;.’ .--__ 
    ‘I 
    System-Wide Problems (Continued) 
    GTE afi!mw SBCS 
    PROCEDURE FOR DETERMINATION OF CAUSE (FLOWCHART 3) 
    REPLACE CPM, MEM, 
    AND SWC CARDS ONE BY 
    ONE. IF RUN LAMP ON 
    CPM CARD IS LIT. SWC 
    SHOULD BE REPLACED. IF 
    NOT LIT, CPM SHOULD BE 
    REPLACED. 
    I YES 
    OPERATION. 
    . 
    RESTORE ODDB 
    THROUGH LOADING 
    OR PROGRAMMING.  
    						
    							Multiple Card/Interface 
    Sismal Proble 
    U 
    . ASSOCIATED WITH MORE THAN ONE DEFECTIVE STATION OR TRUNK BEING 
    SERVED BY MULTIPLE CARDS. 
    . PROBLEMS MAY RESULT FROM: 
    - INTERFACE SIGNAL ASSOCIATED WITH A GROUP OF CARDS BEING SHORTED 
    BY A DEFECTIVE CARD OR OPENED BY A DEFECTIVE BACKPLANE. 
    - DEFECTIVE SWC CARD WHICH IS CONTROLLING THE GROUP. 
    . THREE TYPES OF INTERFACE SIGNAL PROBLEMS MAY OCCUR: 
    1. SIGNALS ASSOCIATED WITH EACH OF THE SIX INTERFACE CARD GROUPS 
    (WHERE EACH ICG HAS ONE INBOUND AND ONE OUTBOUND BUS TO/FROM THE 
    SWC). 
    2. SIGNALS ASSOCIATED WITH ICG 0 THROUGH 2 AND ICG 3 THROUGH 5 (WHERE 
    LOAD SHARING ALLOWS SEVERAL CLOCK AND TIMING SIGNALS FOR 
    ALL LINE/TRUNK CARDS TO BE DRIVEN FROM THE SWC BY TWO SEPARATE 
    GATES). 
    3. SIGNALS USED TO DISTRIBUTE TIME SLOTS AMONG THE CARD SLOTS IN EACH 
    ICG (WHERE EACH ICG HAS ITS OWN BUS AND THREE CARD SLOTS, EXCEPT 
    ICG 5 WHICH HAS A FOURTH CARD SLOT). 
    @ REFER TO FOLLOWING FLOWCHART FOR TROUBLE SHOOTING PROCEDURE FOR 
    MULTIPLE CARD PROBLEMS. 
    3.51  
    						
    							. .._ 
    d/Interface Signal Problems 
    PROCEDURE FOR DETERiVlINATION OF CAUSE 
    TRUNK FAILURE). 
    REMOVE ONE OF 
    AFFECTED LINE/TRUNK 
    CARDS. VERIFY 
    OPERATION 
    OF OTHERS. 
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ; NOTE: COLD RESTART DELETES ODDS. ; TURN POWER ON 
    INITIALIZE HOT 
    RESTART 
    RESTART ODDS THROUGH 
    LOADING OR 
    PROGRAMMING 
    (IF COLD START 
    HAS PERFORMED). 
    I 
    3.52  
    						
    							l ASSOCIATED WITH MORE THAN ONE DEFECTIVE STATION OR TRUNK 
    BEING SERVED BY THE SAME LlNE OR TRUNK CARD. 
    . PRESCRIPTIVE ACTION MAY INCLUDE: 
    - REPLACING THE DEFECTIVE LINE OR TRUNK CARD. 
    - CHECKING FOR A LOOSE CONNECTION BETWEEN ICG CONNECTORS 
    AND PINS AT THE CABINET. 
    3.53  
    						
    							r .--. 
    3.54  
    						
    							Single Station or Tr n&g Problems 
    : 
    . ASSOCIATED WITH A SINGLE STATION OR TRUNK. 
    . PROBLEMS MAY RESULT FROM: 
    - DEFECTIVE LINE/TRUNK CIRCUIT. 
    - FAULTY WIRING BETWEEN LINE CIRCUIT AND STATION, OR BETWEEN 
    TRUNK CIRCUIT AND EXCHANGE (CO OR HOST PABX). 
    - DEFECTIVE STATION INSTRUMENT OR CONNECTING CO/PABX. 
    - STATION/TRUNK WAS NOT INSTALLED IN DATA BASE. 
    - TRUNK CIRCUIT WAS PROGRAMMED FOR A DIFFERENT SIGNALING 
    MODE (GROUND OR LOOP START) THAN THE CENTRAL OFFICE. 
    . 
    REFER TO FOLLOWING FLOW CHART FOR TROUBLESHOOTING 
    PROCEDURE FOR SINGLE STATION OR TRUNK PROBLEMS. 
    3.55  
    						
    							Single Station or Trunk 
    !§ 
    tinue 
    PROCEDURE FOR DETERMINATION OF CAUSE 
    TRUNK INSTALLED NO 
    IN DATA BASE l INSTALL STATION/ 
    TRUNK IN DATA BASE 
    WITH CMC COMMAND. 
    VERIFY STATION/ 
    TRUNK OPERATION. 
    f 
    PLACE STATION/ 
    YES TRUNK IN SERVICE 
    h WITH CMC-701. 
    VERIFY STATION 
    TRUNK OPERATION. 
    REPLACE LINE/TRUNK 
    CARD SERVING 
    DEFECTIVE NO 
    (CONSULT WITH 
    (CAUSE: FAULTY 
    INSTRUMENT OR LOOSE 
    3.56  
    						
    							. RINGING PROBLEMS MAY RESULT FROM: 
    - DEFECTIVE RGEN CARD (LIKELY CAUSE IF ALARM LAMP ON CPM 
    CARD IS LIT). 
    - OUTPUT FROM RGEN CARD BEING SHORTED BY A LINE OR TRUNKI 
    CARD. 
    - RGEN CARD SET TO PROVIDE SYSTEM WITH DC VOLTAGE FOR 
    MESSAGE WAITING SERVICE, BUT MESSAGE WAITING WAS NOT 
    SPECIFIED IN THE DATA BASE. 
    . REFER TO FOLLOWING FLOWCHART FOR TROUBLESHOOTING 
    PROCEDURES FOR RINGING PROBLEMS. 