    of 656
    							-, ,, : 
    :, ‘1 
    NUMER 
    KEYS 
    PRINTER 
    PAPER OFF ON 
    FEED 
    FUNCTION KEYS 
    CASSETTE COPY ADD/CHG 
    DUP DSP 
    RLS CAN 
    L JUUU 
    0 STANDARD TYPEWRITER FORMAT. 
    @ SPECIAL CONTROL, KEYS TO ENABLE FUNCTION A RlNTER O~ERATIONm 
    PROGRAM FUNCTION (PF) KEYS WHICH CHANGE M 
    CONTROL PROGRAM OPERATION. ND FUNCTION DURlN 
    @ CURSOR CONTROL KEYS FOR QUICK MOVEMENT OF CURSOR. 
    @ NUMERIC KEYS FOR ENTRY OF DATA BASE PARAMETER VALUES. 
    2.10  
    						
    							@ USES STANDARD IWHCROCASSETTE TAPES: 
    R SAVING PIMP 
    PWO@RANl 
    FEE DEP 
    DATA BASE 
    USED TO LOAD 
    GR INT 
    OF INITIALIZATI EMORY AT TI 
    ER 
    DISCHARGE. 
    @ USED TO SAVE AND LOAD OFFICE DEPENDENT DATA BASE. 
    2.11  
    						
    							1 PROCEDURE 1 
    (1) COMPLETE ANY CMC COMMAND IN PROGRESS AND ENSURE CURSOR IS DISPLAYED Oil 
    SCREEN. 
    (2) PRESS PRlNTER ON/OFF SWITCH (LOCATED ON SIDE OF PMP). 
    (3) PRESS CONTROL KEY AND PF2 KEY SIMULTANEOUSLY. 
    (4) 
    AFTER SCREEN HAS PRINTED, PRESS PAPER FEED KEY TO ADVANCE PAPER FOR REMOVAL 
    FROM PMP. 
    NOTE: 
    I. MAKE CERTAIN COMMAND PROCESS HAS BEEN COMPLETED BEFORE ADVANCING PAPE 
    OR PRINTING, OR COMMAND WILL BE INTERRUPTED AND INPUT DATA WILL BE LOST. 
    2. ONLY CONTENTS OF DISPLAY SCREEN IS PRIMTEti. 
    2.12  
    						
    							itilizing 
    t PROCEDURE 1 
    (1) 
    (2) 
    (3) 
    (4) 
    (5) CONNECT PORTABLE MAINTENANCE PANEL CABLE TO 
    PORT 8. IF NOT CONNECTED ALREADY. 
    POWER ON PMP BY PRESSING POWER ON SWITCH 
    LOCATED ON RIGHT SIDE OF PMP. 
    THE PROGRAM MENU WILL BE DISPLAYED: PRESS CONTROL AND @ KEYS SIMULTA- 
    NEOUSLY. PMP WILL DISPLAY THE FOLLOWING 
    SCREEN WHICH PROMPTS FOR YEAR, DATE, AND TIME: 
    TYPE YEAR, DATE, AND TIME (AS IN EXAMPLE): 
    f 7 
    PRESS RETURM KEY, PMP WILL DISPLAY FOLLOWING 
    SCREEN: 
    IF MENU DOES NOT APPEAR, PRESS RESET SWITCH 
    LOCATED ON RIGHT REAR OF PMP. 
    (6) 
    (7) 
    (8) 
    (9) 
    PRESS NUMERIC 2 KEY TO SELECT BASIC MODE. 
    DO NOT PRESS RETURN. SCREEN WILL DISPLAY: 
    COPYRGHT 1982 BY 
    MICROSOFT & EPSON 
    cl PI: 0 BYTES (10: WAIT APPROXIMATELY FIVE MINUTES. WHEN TAPE HAS 
    FINISHED MOVING, CURSOR WILL APPEAR ON SCREEN: 
    RUN ‘YLwGawER- 
    PUSH TAPE DRIVE COVER RELEASE (ON RIGHT OF PMP) TO (11) TYPE: 
    TlTLE “PMPctrl” (EXACTLY AS SHOWN) AND 
    OPEN TAPE DRIVE. INSERT PMP CONTROL PROGRAM PRESS RETURN. THIS WILL IDENTIFY CONTROL 
    MICROCASSETTE INTO TAPE DRIVE. PROGRAM ON MAIN MENU. 
    TYPE: 
    WIND AND PRESS RETURN TO REWIND TAPE. 
    TYPE: 
    RUN “CASO:LOADER” AND RETURN (MAKING 
    CERTAIN A NUMERIC ZERO IS USED FOR THE FIRST 0 IN 
    THE COMMAND). 
    DISPLAY WILL READ: 
    THEN: 
    WHICH INDICATES MACHINE CODE AND PMP CONTROL 
    PROGRAM ARE BEING LOADED. (12) TYPE: 
    MON AND PRESS RETURN, SCREEN WILL 
    DISPLAY: 
    f 7 
    (13) TYPE: K3. DO NOT PRESS RETURN KEY. 
    / 3 
     / * THE NUMBER THREE (3) IN THIS ENTRY CAN VARY. IT 
    IDENTIFIES THE NUMERIC ORDER OF PROGRAMS IN THE 
    EPSON HX-20. THE MAIN MENU DISPLAYS ALL STORED 
    PROGRA;‘MS IN ORDER. IF PROGRAM THREE ALREADY 
    EXISTS, 3 CANNOT BE USED IN THIS ENTRY. ENTER THE 
    NEXT AVAILABLE NUMBER IN SEQUENCE INSTEAD OF 3. 
    (14) 
    PRESS CONTROL KEY AND [id SIMULTA- 
    NEOUSLY. DO NOT PRESS THE%ETURN KEY. TURN 
    POWER OFF AND THEN ON. MAIN PROGRAM MENU 
    WILL NOW BE DISPLAYED INDICATING THE PMP 
    CONTROL PROGRAM IS NOW LOADED AND WILL RUN 
    AUTOMATICALLY. 
    2.13  
    						
    							1 PROCEDURE 1 
    (1) TURN PMP POWER ON. 
    (2) AFTER MAIN MENU APPEARS AND PORT CONFIGURATION SCREEN 
    ARE DISPLAYED. 
    PRESS THE BREAK KEY. 
    (3) TYPE: “LQGIN2” AND PRESS RETURN. 
    (4) lNSERT PMP CONTROL PROGRAM TAPE INTO CASSETTE TAPE 
    DRIVE. 
    (5) TYPE: “WIND” AND PRESS RETURN. TAPE WILL NOT REWIND. 
    (6) TYPE: “LOA 
    ‘“CASHeLOA ER”” AND PRES RN. WAIT 
    APPROXIMATELY FIVE MINUTES. 
    (7) AFTER TAPE STOPS MOVING, INSERT BLANK TAPES. 
    (8) TYPE: “WIN 
    SS RETURN. TAPE WILL REWIND. 
    (9) AFTER TAPE STOPS, TYPE: 
    (IQ) AFTER TA E STOPS, TYPE: “ 
    PRESS RETURN. 
    2.14  
    						
    							boratory Activity - Data Base verview 
    Gull aww SBCS 
    INSTRUCTIONS: PERFORM THE FOLLOWlNG TASKS IN THE SEQUENCE OUTLINED BELoW IN 
    ACCORDANCE WITH THE STUDENT WORKBOOK, THE OMNI GTEP MANUAL AND 
    PRIMER. 
    WORK ORDER #2.1 
    COMPANY NAME: NU SYSTEM CO. PHONE #: (703) 5551212 
    LOCATION: RESTON, VIRGINIA WORK ORDER #2.1 (TASK #1) 
    ORIGINATOR: TELECOMMUNICATIONS MANAGER 
    TASKS: 
    e Initialize and load PMP Control program microcassette tape. 
    e Create a backup copy of the PMP Control Program. 
    INSTRUCTIONS: 
    (1) Power ON the PMP. 
    (2) Load the PMP Control Program from the microcassette tape using 
    the procedure in the Student Workbook. 
    (3) Using the blank microcassette tape, make a backup of the original PMP 
    Control Program tape using the procedure in the Student Workbook. 
    2.16  
    						
    							@ ACCESS CODES ARE PROVIDED FOR TWO LEVELS OF SECURITY 
    (ACCESS CODES CHANGE ACCORDING TO SOFTWARE VERSION 
    RELEASE). 
    I SECURITY LEVELS SVRul.O.2.2, SVR.l.5.X.X AND 2.0.X,X 
    (PACKAGE A) 
    (PACKAGES B AND C) I 
    HIGH SECURITY ACCESS 
    LOW SECURITY ACCESS 
    . HIGH SECURITY CODES ALLOW ACCESS TO ALL CMC TABLES. 
    Q) LOW SECURITY CODES ALLOW ACCESS TO CM6 TABLES WHICH Do 
    NOT HAVE CRITICAL IMPACT ON SYSTEM. 
    @ REQUIRED SECURITY LEVEL IS NOTED IN CMC TABLE LISTING IN 
    OMNI SBCS GTEP MANUAL. 
    2.17  
    						
    							@ IF HIGH LEVEL SECURITY CODE IS ENTERED AT SECURITY CODE PROMPT (AS 
    ILLUSTRATED IBELOW), ALL CMC COMMANDS MAY BE ACCESSED. ENTER 
    APPROPRIATE CODE FOR SOFTWARE RELEASE AND PRESS RETURN. 
    SECURITY CODE = #803 
    L-J 
    0 IF LOW LEVEL CODE IS ENTERED AT SECURITY PROMPT AND ACCESS TO A CMC 
    COMMAND REQUIRING HIGH SECURITY IS ATTEMPTED, PMP WILL DISPLAY 
    “LOCKED” MESSAGE (AS ILLUSTRATED BELOW): 
    NOTE: FOR SOFTWARE VERSION I.&X.X, USERS MUST PRESS SHIFT + PFI TO EXIT TO 
    THE INITIAL SECURITY PROMPT. THEN THE HIGH LEVEL CODE MUST BE ENTERED TO 
    ACCESS THE COMMAND REQUIRING HIGH SECURITY. 
    FOR SOFTWARE VERSION 1.0.2.2, USERS MAY ENTER THE HIGH LEVEL CODE AT T 
    POINT WHERE THEY RECEIVE THE “LOCKED” MESSAGE. THIS WILL UNLOCK THE 
    C 
    COMMAND AND ALLOW ENTRY. (THE PMP WILL REVERT TO LOW LEVEL STATUS AFTER 
    THE USER EXITS FROM THE HIGH LEVEL CMC COMMAND.) 
    2.18  
    						
    							PMP Control Program Access 
    [PROCEDURE 1 
    (1) POWER ON PMP. A SCREEN DISPLAYING 
    MAIN PROGRAM MENU AND COPYRIGHT 
    INFORMATION WILL APPEAR BRIEFLY AND 
    THEN DISAPPEAR. PMP PORT CONFIGURATION 
    WILL BE DISPLAYED: 
    f 1 
    PORT CONFIGURATION 
    CHANGE? 
    YES OR NO (YIN) 
    (2) ENTER: N DO-URN. 
    THIS WILL SKIP PORT CONFIGURATION 
    SCREENS AND ASSUME DEFAULT VALUES 
    WHICH ARE PRESENT TO MATCH OMNI SBCS 
    DEFAULT PORT 0 CONFIGURATION. 
    (3) SECURITY CODE PROMPT WILL NOW BE 
    DISPLAYED: f-1 
    SECURITY CODE= 
    ENTER DESIRED SECURITY LEVEL NUMBER: 
    #380 AND 
    PRESS RETURN KEY. SECURITY 
    CODE WILL NOT APPEAR (ECHO) ON SCREEN. 
    IF SECURITY CODE IS NOT ACCEPTED, SYSTEM 
    DISPLAYS: 
    SECURITY CODE= 
    ERROR 
    I 
    2.19 IF ANOTHER TERMINAL HAS ACCESS TO THE 
    SYSTEM (A MODEM OR ANOTHER PMP 
    CONNECTED TO CN14), SYSTEM DISPLAYS: 
    f 3 
    SECURITY CODE= 
    BUSY 
    (4) IF SECURITY ACCESS HAS BEEN CLEARED, THE 
    FOLLOWING SCREEN APPEARS WHICH 
    INDICATES THAT USER IS NOW IN PMP 
    COMMAND MODE: 
    CMC= ##### COMMAND READY 
    L-J 
    NOTE: IF HIGH SECURITY LEVEL IS REQUIRED WHEN 
    USING SVR 1.0.2.2, SYSTEM DISPLAYS: 
    CMC=- 
    END 
    ENTER REQUIRED HIGH LEVEL SECURITY 
    CODE TO OBTAIN CMC ACCESS.  
    						