    							Review Exercise (1.1) - Installation 
    INSTRUCTIONS: 
    THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, FILL IN THE BLANK OR MATCHING 
    TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E. STUDENT WORKBOOK, NOTES, AND GTEP 
    MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO INSTRUCTOR FOR GRADING 
    WHEN LAST QUESTION HAS BEEN COMPLETED. 
    1. 
    2. 
    3. 
    4. 
    5. 
    6. (TRUE OR FALSE) 
    THE OMNI SBCS SYSTEM REQUIRES ADDITIONAL COOLING. 
    (TRUE OR FALSE) 
    THE OMNI SBCS POWER SUPPLY WILL ACCEPT EITHER 110 VAC, 220 VAC, OR 
    48 VDC AS ITS INPUT POWER SOURCE. 
    Tl-iE SYSTEM BACKUP BATTERY WILL MAINTAIN THE SYSTEM MEMORY FOR A PERIOD OF 
    APPROXIMATELY: 
    A. 2 DAYS B. 5 DAYS C. 1 WEEK 
    D. 2 WEEKS 
    (TRUE OR FALSE) 
    THE DEFAULT STANDARD DATA BASE MUST BE LOADED FROM TAPE OR FLOPPY 
    DISKETTE AT TIME OF SYSTEM INSTALLATION. 
    THE COMMON CONTROL CARDS REQUIRED FOR A MINIMUM SYSTEM CONFIGURATION CONSIST OF: 
    A. 
    CPM, SWC, AND RGEN CARDS 
    B. CMC, MEM, AND RGEN CARDS 
    C. CPM, 4DMR, AND 6PFT CARDS 
    D. CPM, SWC, AND MEM CARDS 
    THE MAXIMUM NUMBER OF STATIONS SUPPORTED BY THE SYSTEM IS 
    AND 
    THE MAXIMUM 
    NUMBER OF TRUNKS SUPPORTED BY THE SYSTEM IS 
    , ALTHOUGH THESE CAPACITIES 
    CANNOT 
    BE ACHIEVED SIMULTANEOUSLY. 
    1.34  
    						
    							7. (TRUE OR FALSE) GTE’ OMNL’SBGS CARD SLOTS 06 THROUGH 18 CAN CONTAIN LINE OR TRUNK CARDS. 
    8. (TRUE OR FALSE) 
    CARD SLOTS 19,20, AND 21 ARE RESERVED FOR COMMON CONTROL CARDS. 
    9. THE TWO RS-232-C PORTS AVAILABLE ON THE SYSTEM CABINET FOR THE PORTABLE MAINTENANCE PANEL OR THE 
    SMDR PRINTER ARE 
    OR 
    MATCH THE FOLLOWING CARDS WITH THE CORRECT DESCRIPTION: 
    10. 
    11. 
    12. 
    13. 
    14. 
    15. 
    16. 
    17. 
    18. 
    19. 
    20. 
    21. CPM CARD 
    MEM CARD 
    SWC CARD 
    RGEN CARD 
    8EKC CARD 
    8SLC CARD 
    4BWC CARD 
    2TTE CARD 
    2TTL CARD 
    4DMR CARD 
    6PFT CARD 
    8DTC CARD A. 
    B. 
    C. 
    D. 
    E. 
    F. 
    G. 
    H. 
    I. 
    J. 
    K. 
    L. 2 CIRCUIT E&M TIE LINE TRUNK CARD SUPPORTING TYPE I AND TYPE II 
    SIGNALING 
    8 CIRCUIT LINE CARD SUPPORTING ELECTRONIC KEY TELEPHONES 
    CONTANS PCM TIME DIVISION MULTIPLEXOR/DEMULTlPLEXOR CIRCUITS 
    INTERFACES WITH 8SLC AND 4BWC CARD TO PROVIDE SIX POWER FAIL 
    TRANSFER STATIONS 
    8 CIRCUIT DIGITAL INTERFACE CARD SUPPORTING CSD TELEPHONES AND 
    DATA INTERFACE UNITS 
    4 CIRCUIT CO TRUNK CARD WHICH CAN ALSO PROVIDE MUSIC-ON-HOLD, 
    EXTERNAL PAGING, AND POWER FAILURE TRANSFER INTERFACES 
    8 CIRCUIT LINE CARD SUPPORTING DTMF AND ROTARY DIAL SINGLE LINE 
    TELEPHONES 
    2 CIRCUIT LOOP START TIE LINE TRUNK CARD 
    CONTAINS ADDITIONAL MEMORY AS EXTENSION OF CPM CARD WITH ROM 
    FOR OPERATING SYSTEM SOFTWARE AND RAM FOR CUSTOMIZED DATA BASE 
    4 CIRCUIT CARD PROVIDING TONES IF TELEPHONES REQUIRING DUAL TONE 
    MULTI-FREQUENCY ARE INSTALLED 
    GENERATES RINGING TONES FOR SINGLE LINE TELEPHONES OR POWER TO 
    MESSAGE WAITING FEATURE ON SINGLE LINE TELEPHONES WITH MESSAGE 
    WAITING LAMP 
    CONTAINS 16 BIT MICROPROCESSOR FOR SYSTEM OPERATION, REAL TIME 
    CLOCK, AND ROM FOR OPERATING SYSTEM SOFTWARE AND RAM FOR 
    CUSTOMIZED DATA BASE 
    1.35  
    						
    							MATCH THE FOLLOWING COMPONENTS WITH THE CORRECT DESCRIPTION: 
    22. cs-10 
    23. cs-20 
    24. CSD 
    25. BLF/DSS A. 
    B. 
    C. 
    D. 
    26. PMP 
    E. 
    27. SMDR 
    28. MUSIC-ON-HOLD 
    29. SLT 
    30. FLOPPY DISKETTE 
    DRIVE F. 
    G. 
    H. 
    I. DTMF OR DIAL PULSE (ROTARY) TELEPHONE INSTRUMENT 
    ELECTRONIC KEY TELEPHONE WITH 10 PROGRAMMABLE BUTTONS AND 
    MONITOR CAPABILITIES 
    MICROCOMPUTER USED FOR SYSTEM DATA BASE ADMINISTRATION AND 
    MAINTENANCE 
    OPTIONAL UNIT USED TO DECREASE TIME ASSOCIATED WITH SAVING OR 
    LOADING THE CUSTOMIZED DATA BASE 
    PROVIDES MUSIC TO CALLING PARTIES BY MUSIC SOURCE INTERFACED 
    THROUGH A 4BWC CARD 
    ELECTRONIC KEY TELEPHONE WITH 10 PROGRAMMABLE BUTTONS, 
    SPEAKERPHONE, AND 20 CHARACTER LCD DISPLAY 
    40 OR 80 BUTTON EXPANSION MODULE USED TO PROVIDE VISUAL INDICATORS 
    FOR STATUS OF LINES IN SYSTEM 
    PRINTER USED TO PROVIDE HARD COPY RECORDS OF SYSTEM CALLS 
    DIGITAL TELEPHONE WHICH CAN PROVIDE INTERFACE TO DATA TERMINAL IF 
    EQUIPPED WITH DATA TERMINAL ADAPTER (DTA) 
    31. (TRUE OR FALSE) 
    ONLY SIX ELECTRONIC KEY TELEPHONES MAY BE DESIGNATED AS POWER FAIL 
    TRANSFER STATIONS. 
    1.36  
    						
    							TEM INSTAL ATION 
    Cabinet Installation 
    1.38  
    						
    							1.2 Enabling Objective/ 
    binet Inst 
    GIVEN: 0 
    GTE OlVlNl SBCS WITH MOUNTING BRACKET, CABINET, AND POWER SUPPLY 
    0 
    GTE OMNI SBCS PCB CARDS 
    0 
    #6 AWG CABLE, POWER SUPPLY CABLE, AND HARDWARE 
    0 
    GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE 
    0 
    STANDARD INSTALLATION TOOLS 
    0 
    REVIEW EXERCISE 
    ACTION: 0 
    0 
    0 
    0 
    0 
    CRITERIA: 0 
    0 MOUNT AND INSTALL SYSTEM CABINET AND POWER SUPPLY. 
    CONNECT POWER SUPPLY CABLE. 
    GROUND WIRE TERMINALS TO COLD WATER GROUND AND CONNECT SIGNAL 
    WIRE GROUND. 
    INSERT AND SEAT COMMON CONTROL, LINE, TRUNK, AND RING GENERATOR 
    CARDS IN CORRECT CARD SLOTS. 
    COMPLETE REVIEW EXERCISE. 
    CABINET AND POWER SUPPLY WILL BE INSTALLED AND GROUNDED IN 
    ACCORDANCE WITH GTE OMNI SBCS GTEP MANUAL. CARDS WILL BE 
    INSERTED AND SEATED CORRECTLY IN DESIGNATED CARD SLOTS. 
    REVIEW EXERCISE QUESTIONS WILL BE COMPLETED CORRECTLY IN 
    ACCORDANCE WITH PASS/FAIL CRITERIA OF THIS TRAINING ORGANBZ 
    1.39  
    						
    							ask Installation Se 
    (1) 
    (2) 
    (3) 
    (4) 
    (5) 
    (6) 
    (7) 
    (8) 
    (9) 
    (10) 
    (11) 
    (12) INSTALL MOUNTING BRACKET. 
    MOUNT AND INSTALL CABINET AND POWER SUPPLY. (NOTE: DO NOT POWER 
    ON SYSTEM UNTIL CARDS AND PERIPHERALS HAVE BEEN INSTALLED). 
    GROUND POWER SUPPLY AND CABINET. 
    INSTALL COMMON CONTROL CARDS, LINE CARDS, AND TRUNK CARDS. 
    INSTALL CABLES FROM CABINET AND RECEPTACLES TO CDF CROSS 
    CONNECTION BLOCKS. 
    WIRE ALL STATION AND TRUNK CROSS CONNECTIONS. 
    INSTALL PERIPHERAL INSTRUMENTS (E.G., STATION INSTRUMENTS, BLF/DSS 
    CONSOLES, SMDR, PMP, ETC.). 
    POWER SYSTEM ON. 
    COLD RESTART SYSTEM TO ESTABLISH DEFAULT STANDARD DATA BASE. 
    VERIFY SYSTEM/FEATURE OPERATION. 
    DRESS AND TIE CABLES AS REQUIRED. CLEAR INSTALLATION SITE. 
    MODIFY DEFAULT STANDARD DATA BASE TO MEET CUSTOMER’S 
    REQUIREMENTS. 
    1.40  
    						
    							(1) 
    (2) 
    (3) 
     lh MOUNTING 
    ““7\‘1 MOUNTING 
    EQu’PMENTeE “I& 
    CABINET 
    MOUNT EQUIPMENT CA5lNET TO THE MOUNTING BRACKET BY 
    LOWERING THE CABINET ONTO THE BRACKETS. 
    AFTER CABINET IS SECURELY MOUNTED, THEN INSTALL THE 
    POWER SUPPLY. 
    SECURE BOTH CABINET AND POWER SUPPLY WITH THE SCREWS 
    PROVIDED. 
    1.42  
    						
    							Cabinet - Power Supply Cable 
    TO POWER 
    SUPPLY 
    UNIT TO 
    EQUIPMENT 
    CABINET 
    SAFETY 
    KEY 
    SAFETY 
    KEY 
    BOWER 
    SUPPLV 
    RECEPTACLE 
    FRONT VIEW OF CONNECTORS 
    LOCATION OF RECEPTACLES 
    CABLE FOR 
    CABINET-POWER SUPPLY CONNECTION 
    NOTE: CONNECT POWER SUPPLY CABLE TO EQUIPIVIEMT CABINET 
    ONLY WHEN SY IMSTALLATBO PROCEDURE HAS BEEN 
    COMPLETED. 
    1.43  
    						
    All GTE manuals Comments (0)