Have a look at the manual Starplus Triad Xts Installation Digital Key Telephone System Instructions Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 Triad manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Quick Reference TablesF-7 Appendix F - Flash Codes and Numbering Plans Erase Digits2-104 None CO LINE ATTRIBUTES PAGE A PROGRAMMING FLASH 40 Btn 19 DTMF/Dial Pulse Programming 2-66Page A 1 DTMF CO/PBX Programming 2-512CO Universal Night Answer (UNA) 2-2043Enabled DISA CO-to-CO 2-1134Enabled Privacy 2-2205Enabled Loop Supervision Programming 2-816 4=400 ms DISA Programming 2-1117 None CO Line Group Programming 2-698Group01 Class of Service (COS) Programming 2-579COS1 CO Line Ringing Assignments 2-7210 Station 100 CO Line Identification Display 2-7011 Line XXX CO Direction 2-8712 Incoming/Outgoing Display Ring Assignments 2-7413 100A DID/TIE Signal 2-10714 Wink 911 Attendant Alert 3-515 Disabled EKTS 2-15916 Disabled CO LINE ATTRIBUTES PAGE B PROGRAMMING FLASH 40 Btn 20 T-1 Signaling Type 2-261Page B 1 Loop Star t T-1 Ringback 2-2622Enabled T-1 Dial Tone 2-2633 Disabled Transmit Volume 2-7845=0dB Preset Call Forward Destination 2-365 None Preset Forward Voice Mail ID 2-376 None Universal Day Answer (UDA) 2-2887 Disabled Music-On-Hold (per CO Line) 2-1968 Channel 1 Ring Tone (per CO Line) 2-1629 Tone # 00 Directory Number (BRI) 2-16010 None SPID 2-16211 None CO LINE ATTRIBUTES PAGE C PROGRAMMING FLASH 40 Btn 21 Flash Timer Programming 2-53Page C 1 10=1.0 sec Ring Delay Timer A-102 00=Disabled Wink Timer 2-2633 140 ms Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
F-8Quick Reference Tables Appendix F - Flash Codes and Numbering Plans Release Timer2-754 020=200 ms Reseize Timer 2-765 200=200 sec Guard Timer 2-776 05=.5 sec Seize Timer 2-777 010=0.1 sec Preset Forward Timer 2-38810sec DID Collect Timer 2-1089 015=150 ms T-1 Collect Timer 2-26410 015=150 ms MISCELLANEOUS CO PARAMETERS FLASH 41 Dial Pulse Parameters 2-981 60/40, 10 pps DID Digits 2-10633 DID Incoming Signal 2-1075DTMF T-1 Incoming Signal 2-2656DTMF T-1 Framing Type 2-2657D4SF-AMI CO FLEXIBLE PORT ASSIGNMENT 2-60FLASH 42 1-6 (MPB1); 1-18 (MPB2)CO Por ts 1-48 (MPB1); 1-144 (MPB2) ICLID PROGRAMMING FLASH 43 ICLID Ringing Assignment(s) 2-1041 None View ICLID Ringing Assignments 2-10517 Next ICLID Route Number 2-10618 Previous ICLID Route Number 2-10619 Select Route Number 2-10620 DID PROGRAMMING FLASH 44 Route Number 2-1011 refer toFigure A-3onpage A-15 DID Phone Number2-1022 None Name Assigned to Number 2-1033 None Erasing a DID Table Entry 2-1034 None ISDN PAGE A PROGRAMMING FLASH 45 Btn 19 BRI CO Type 2-164Page A 1 NI1 PRI CO Type 2-1642NI2 Framing 2-1653ESF NT/TE Mode 2-1654TE Power 2-1665 Disabled Directory Number (PRI) 2-1666 None Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
Quick Reference TablesF-9 Appendix F - Flash Codes and Numbering Plans Max Out I-Frames2-1667 K 001 Leading 1 2-1678Enabled Leading 011 2-1679Enabled 7/8 Digit Number Plan 2-16810 ITU Calling Number 2-16811 Enabled Loopback 2-16912 Normal 10 Digit Number Plan 2-16913 ITU 11 Digit Number Plan 2-17014 ITU ISDN PAGE B PROGRAMMING FLASH 45 Btn 20 Maximum Number Retransmission 2-172Page B 1 3 Maximum Octets 2-1722260 Maximum TEI ID Request 2-1733003 Maximum XID Retransmission 2-17343sec T-200 2-173501sec Minimum TEI ID Check Message 2-174601sec Minimum TEI ID Request 2-174702sec Message Exchange Timer 2-174815sec Minimum XID Retransmission 2-17593sec Inter Digit T/O 2-17510 25 sec Set-up Timer 2-17611 10 sec Disconnect Timer 2-17612 04 sec Release Request 2-17713 04 sec Link Disconnect 2-17714 30 sec Call Proceeding 2-17715 60 sec Connect Request 2-17816 04 sec Restart Request Timer 2-17817 120 sec VOIP NETWORK PROGRAMMING FLASH 46 IP Address D-101 None Subnet Mask D-102 None Router IP Address D-103 None Domain Name D-114 None Vocoder Value D-115 G.723.1 T-1/ISDN ALARM PROGRAMMING FLASH 47 Carrier Loss Alarm 2-2671Enabled Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
F-10Quick Reference Tables Appendix F - Flash Codes and Numbering Plans Blue Alarm2-2672Enabled Yellow Alarm 2-2683Enabled Red Alarm 2-2694Enabled Bipolar Alarm 2-2695Enabled Frame Slip Alarm 2-2706Enabled Data Errors Alarm 2-2707Enabled Enable/Disable (Carrier Loss Alarm) 2-26711 Enabled Clear Alarm 2-27112 Enabled Minor Alarm 2-27113 15 min Major Alarm 2-27214 30 min Time Period 2-27215 5 min Attendant Display 2-27316 Enabled STATION ATTRIBUTES PAGE A PROGRAMMING FLASH 50 Btn 19 Paging Access 2-210Page A 1 Enabled Do Not Disturb 2-1262Enabled Conference Enable/Disable (Per Station) 2-913Enabled Executive Override 2-1294 Disabled Privacy (Per Station) 2-2225Enabled System Speed Dial Access 2-2396Enabled Line Queuing 2-827Enabled Preferred Line Answer 2-2198Enabled Off-Hook Voice Over (OHVO) 2-2059 Disabled Call Forward - Enable/Disable 2-2510 Enabled Forced Least Cost Routing (LCR) B-1511 Disabled ACD Supervisor Monitor with Barge-In 4-2812 Disabled Executive Override Blocking 2-13113 Disabled CO Line Ringing Options 2-8414 Muted Ring Name/Number Display at Idle 2-19915 Name (Enabled) ACD Zap Tone 4-3216 Disabled CO Line, Loop, and Pool Buttons 2-7917 Disabled Admin Access 2-9518 Disabled STATION ATTRIBUTES PAGE B PROGRAMMING FLASH 50 Btn 20 Station Identification 2-246Page B 1 006 (24-Btn Key set) 6(SLTw/oMW) Station Day Class of Service (COS) 2-582COS1 Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
Quick Reference TablesF-11 Appendix F - Flash Codes and Numbering Plans Station Night Class of Service (COS)2-593COS1 Speakerphone/Headset Programming 2-23640 (Full Speakerphone) Pick-Up Group(s) Programming 2-445Group1 Paging Zone(s) Programming 2-2126Zone1 Line Group Access - Station 2-688Group1 LCR Class of Service (COS) B-169 0 (Unrestricted Access) Off-Hook Preference Programming 2-22910 00=No specific button preferred; Enabled Flexible Button Programming 2-13711 (blank) Keyset Mode 2-18212 Inactive Mode Voice Mail ID Translation 2-29513 XXXX=Station # Display Flexible Buttons 2-14114 None Cordless Key Telephone Unit (CKTU) Button 2-9417 00=No button assigned STATION ATTRIBUTES PAGE C PROGRAMMING FLASH 50 Btn 21 Internal No Answer Forward 2-35Page C 1 None Internal Busy Forward 2-352 None External No Answer Forward 2-353 None External Busy Forward 2-364 None No Answer Timer 2-36510sec Speed Dial Access 2-2396 None FLEXIBLE NUMBERING ASSIGNMENT FLASH 52 Changing a Flexible Code 2-1431 None Erasing a Flexible Code 2-1432 None Selecting a Flexible Code 2-14321 None Next Code Entry 2-14322 None Previous Code Entry 2-14323 None Selecting a Fixed Code 2-14324 None NAME/NUMBER TRANSLATION TABLE FLASH 55 Route Number 2-20011 Phone Number 2-2012 None Name 2-2013 None Clear Entry 2-2014 None ICLID FEATURES FLASH 56 Enable/Disable A-81NO=Disabled Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
F-12Quick Reference Tables Appendix F - Flash Codes and Numbering Plans Name in DisplayA-82 YES=phone number in display Baud Rate Display A-83 19.2K Port Assignment A-94Port#1 ACD GROUP PROGRAMMING* FLASH 60 Group Name 4-131 None Alternate Group 4-122 None Overflow Station 4-383 None Supervisor 4-304 None CIQ Threshold 4-135 Disabled Wrap-up Timer 4-3164sec Primary Agents 4-207 None Secondary Agents 4-258 None Guaranteed RAN 4-149 None Primary RAN 4-2110 None Secondary RAN 4-2511 None Transferred R AN 4-3112 None Overflow Timer 4-1813 60 sec Call Factor 4-714 None ACD TIMERS FLASH 61 ACD Ring Timer 4-24160sec ACD Message Interval Timer 4-15260sec ACD No-Answer Recall Timer 4-165000=Disabled ACD No-Answer Retry Timer 4-166 300 sec ACD Guaranteed Message Timer 4-1575sec ACD RAN ANNOUNCEMENT TABLES* 4-22FLASH 62 1–8 None PC/ACD INTERFACE TRACE FLASH 63 Event Trace Disable/Enable 4-191No(Disabled) Trace Por t Assignment 4-202Port#1 Baud Rate Display 4-19-- 19.2K UCD GROUP PROGRAMMING FLASH 60 Alternate UCD Group Assignment 4-362 None UCD Overflow Station Assignment 4-383 None UCD Primary Agent Assignments 4-407 None UCD Primary RAN 4-4110 None Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
Quick Reference TablesF-13 Appendix F - Flash Codes and Numbering Plans UCD Secondary RAN4-4511 None UCD TIMERS FLASH 61 UCD Ring Timer 4-44160sec UCD Message Interval Timer 4-36260sec UCD Overflow Timer 4-40360sec UCD Auto Wrap-Up Timer 4-464 004 sec UCD No-Answer Recall Timer 4-375000=Disabled UCD No-Answer Retry Timer 4-386 300 sec UCD ANNOUNCEMENT TABLES (RAN) 4-42FLASH 62 1–8 None VOICE MAIL PROGRAMMING FLASH 65 Voice Mail Groups (440-447) 2-2911–8 None Alternate Voice Mail Group 2-2919 None Leave Mail Index Entry 2-29210 440 = 0 Retrieve Mail Index Entry 2-29211 440 = 1 Station Assignment(s) 2-29312 None VOICE MAIL OUTPULSING TABLE FLASH 66 Voice Mail In-Band Signaling (Table 0) 2-3071Pre=P7Suf=None (Table 1) 2-3072 Pre=P7 Suf=* (Tables 2-6) 2-3073-7 None (Table 7) 2-3078 Pre=P7; Suf=2 (one-touch record) Voice Mail Disconnect Table 2-3089 None VOICE MAIL IN-BAND FEATURES FLASH 67 Voice Mail In-Band Digits 2-3061Enabled Voice Mail Transfer/Forward 2-3012Enabled Voice Mail Broker 2-3023Enabled VMID Digit Length 2-30243 Remote VM Number (Networking) C-265 None VM Port 2-3036 Disabled VM Port Number 2-30373 TOLL RESTRICTION PROGRAMMING FLASH 70 Allow Table A Programming 2-2791 None Deny Table A Programming 2-2812 None Allow Table B Programming 2-2793 None Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
F-14Quick Reference Tables Appendix F - Flash Codes and Numbering Plans Deny Table B Programming2-2814 None Special Table 1 Programming 2-2825 All Codes Denied Special Table 2 Programming 2-2826 All Codes Denied Special Table 3 Programming 2-2827 All Codes Denied Special Table 4 Programming 2-2828Home Area Code for Special Table 1 2-2829 None Area Code for Special Table 2 2-28210 None Area Code for Special Table 3 2-28211 None Displaying Toll Table Entries 2-28312 None LCR TABLES PROGRAMMING FLASH 75 3-Digit Area/Office Code Table B-61 None 6-Digit Area/Office Code Table B-72 None Exception Code Table B-73 None Route List Table B-84 None Insert/Delete Table B-105 None Daily Start Time Table B-116 None Weekly Schedule Table B-127 None LCR Routing for Toll Information B-148Table0 INITIALIZE DATABASE PARAMETERS FLASH 80 Initialize System Parameters 2-2541Default Initialize CO Line Attributes 2-632Default Initialize Station Attributes 2-2433Default Initialize CO Port Assignments / Codes 2-884Default Initialize Exception Tables 2-2845Default Initialize System Speed Numbers 2-2416Default Initialize LCR Tables B-187Default Initialize ICLID-DID Tables A-118Default Initialize Dir Dialing Table Parameters 2-1209Default Initialize Hunt Group Parameters 2-15110 Default Initialize ACD*/UCD Group Parameters 4-33/4-4711 Default Initialize Voice Mail* Group Parameters 2-29812 Default Initialize DID-TIE Parameters 2-10913 Default Initialize Verified Account Code Table 2-1114 Default Initialize ISDN/VoIP Parameters 2-17915 Default Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
Quick Reference TablesF-15 Appendix F - Flash Codes and Numbering Plans System Reset2-26020 --- PRINTING SYSTEM DATABASE PARAMETERS FLASH 85 Printing System Parameters 2-2581Default Printing CO Line Attributes 2-652Default Printing Station Attributes 2-2453Default Printing CO Por t Parameters / Codes 2-894Default Printing Exception Tables 2-2855Default Printing System Speed Numbers 2-2426Default Printing LCR Tables B-197Default Printing Entire System Database 2-978Default Printing ICLID-DID Tables A-129Default Printing Directory Dial Table Parameters 2-12010 Default Printing Hunt Group Parameters 2-15211 Default Printing ACD*/UCD Group Parameters 4-34/4-4812 Default Printing Voice Mail* Group Parameters 2-29913 Default Printing DID-TIE Parameters 2-11014 Default Printing Verified Account Codes 2-1215 Default Printing ISDN/VOIP Parameters 2-18116 Default LOAD DATABASE ROUTINE FLASH 86 Upload Database E-71PCOnly Download Database E-72PCOnly Table F-1: Feature Default Values FeaturesPage #Program CodeFlexible ButtonDefault Value * Features available with Optional Software
F-16Default Numbering Plan Appendix F - Flash Codes and Numbering Plans Default Numbering Plan Function Code Page 911 Attendant Alert View/Delete (requires button) 608/608+FLASH 3-5 Account Code (requires button) 627 2-7 ACD Call Factor* (requires button) 580+[UUU]+[FFF] 4-7 ACD Call Qualifier* 570+[ YYY ] 4-7 ACD CIQ Display Button* (specific ACD group) (requires btn) 579+[UUU] 4-5 ACD Group* (group 1-16) 550-565 -- ACD Help* (requires button) 574 4-3 ACD Member Status* 573 4-8 ACD Overflow Available/Unavailable* 578 4-9 ACD Login (Primary)* 572+[UUU]+[UUUU] 4-10 ACD Login (Secondary)* 582+[UUU]+[UUUU] 4-10 ACD Logout (Primary)* 571 4-10 ACD Logout (Secondary* 581 4-11 ACD Supervisor Display* 577+[UUU] 4-29 ACD Supervisor Login* 576+[UUU]+[UUUU] 4-27 ACD Supervisor Logout* 575+[UUU] 4-27 ACD*/UCD Available/Unavailable 566 4-6 ACD*/UCD Calls In Queue Status Display (any group) 567+[UUU] 4-4 Answering Machine Ring 654+[0] 2-13 Answering Machine Speaker 654+[1] 2-13 Attendant 0 -- Attendant Clear Alarm ( T-1) 606 2-273 Attendant CO Line External (Off-Net) Forward 603+[NNN]+[YYYY ] 3-6 Attendant Custom Message 694+[XX]+message 3-6 Attendant Day/Night/Special (requires button) 631 (DND key) 3-8 Attendant Directory List Programming 693 3-8 Attendant Disable Outgoing CO Line 602+press CO line button 3-12 Attendant Override (requires button) 601 3-12 Attendant Setting Time and Date 692+date and time entry 3-13 Attendant Unavailable 607 3-15 Attendant Voice Mail Alarm Clear 656 3-16 Di git al E lec tr on ic A tt en dan t Sin g leL in e