Home
>
Triad
>
Telephone
>
Starplus Triad Xts Installation Digital Key Telephone System Instructions Guide
Starplus Triad Xts Installation Digital Key Telephone System Instructions Guide
Have a look at the manual Starplus Triad Xts Installation Digital Key Telephone System Instructions Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 Triad manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Speed Dial2-241 Chapter 2 - Features and Operation 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 (Page A) is lit. 4. Pressbutton#21.ThedisplayupdatestoreflectcurrentprogrammingforPageC. XXX-XXX = Station Range 5. Press the SPEED DIAL ACCESS button (FLASH 50, Page C, Button #6). The following message displays: 6. Enter a range of speed bins to be allowed (100-999). The leading digit 9 is not reflected on the LCD and is not used for your entry. 7. PressHOLDtosavetheentry. Speed Bins/Chaining Description Speed dial bins can be chained together. This is helpful for accessing Long Distance carriers or banking services when account codes are required. Operation To chain speed bins together, simply press one speed bin and then another as required. Initialize System/Station Speed Numbers Description System and Station Speed bins may be initialized to reset all bins to their original default value (empty). All bins 9000-9999 are reset to their default value (empty) upon initializing. Programming Steps 1. Press the SPEED NO flexible button (FLASH 80, Button #6). The following message displays: 2. Press the HOLD button. A confirmation tone sounds. XXX-XXX PAGE C ENTER BUTTON NUMBER SYS SPEED BIN 100-999 ###-### INITIALIZE SYS SPEED NO PRESS HOLD
2-242Speed Dial Chapter 2 - Features and Operation Print System Speed Numbers Description The System Speed Numbers command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. Figure 2-17: System Speed Numbers Printout Programming Steps 1. Press the SYSTEM SPEED flexible button(FLASH 85, Button #6). The following message displays: 2. To print the System Speed bins, press the HOLD button. The following message displays: When the system finishes sending the requested information to the printer, a confirmation tone sounds. SYSTEM SPEED NUMBERS 20 37 21 38 22 39 23 40 24 41 25 42 26 43 27 44 28 45 29 46 30 47 31 48 32 49 33 50 34 51 35 52 36 ... and so on through Speed Number 999 PRINT SYS SPEED NO PRESS HOLD PRINTING SYS SPEED NO
Station Attributes2-243 Chapter 2 - Features and Operation Station Attributes Initialize Station Attributes Description The Station Parameters may be initialized setting all data fields to their original, default values. The following data fields are returned to their default value upon initializing the Station Attributes. Table 2-20: Station Attribute Defaults Program CodeFlexible ButtonFeaturesDefault Value (after initialization) FLASH 50 1 Paging Access Enabled PAGE A 2 Do Not Disturb Enabled 3 Conference Enable/Disable (Per Station) Enabled 4 Executive Override Disabled 5 Privacy (Per Station) Enabled 6 System Speed Dial Access Enabled 7 Line Queuing Enabled 8 Preferred Line Answer Enabled 9 Off-Hook Voice Over (OHVO) Disabled 10 Call Forwarding Enabled 11 Forced Least Cost Routing (LCR) Disabled 12 ACD Supervisor Monitor with Barge-In Disabled 13 Executive Override Blocking Disabled 14 CO Line Ringing Options Muted Ring 15 Name/Number Display at Idle Name (Enabled) 16 ACD Zap Tone Disabled 17 CO, Loop, Pool Disabled 18 Admin Access Disabled
2-244Station Attributes Chapter 2 - Features and Operation Programming Steps 1. Press the STATION ATTRIBUTES flexible button (FLASH 80, Button #3). The following message displays: 2. Press the HOLD button. A confirmation tone sounds. FLASH 50 PA G E B1 Station Identification 006 (24-Btn Keyset) 6(SLTw/oMW) 2 Station Day Class of Service (COS) COS 1 3 Station Night Class of Service (COS) COS 1 4 Speakerphone/Headset Programming 0=Full Speakerphone 5 Pick-Up Group(s) Programming Group 1 6 Paging Zone(s) Programming Zone 1 8 Line Group Access - Station Group 1 9 LCR Class of Service (COS) 0 (Unrestricted Access) 10 Off-Hook Preference Programming 00=No specific button preferred; Enabled 11 Flexible Button Programming (blank) 12 Keyset Mode Inactive Mode 13 Voice Mail ID Translation XXXX=Station # 14 Display Flexible Buttons None 17 Cordless Key Telephone Unit (CKTU) Button 00=No button assigned FLASH 50 PA G E C1 Internal No Answer Forward None 2 Internal Busy Forward None 3 External No Answer Forward None 4 External Busy Forward None 5 No Answer Timer 10 sec 6 Speed Dial Access None INITIALIZE STATIONS PRESS HOLD Table 2-20: Station Attribute Defaults Program CodeFlexible ButtonFeaturesDefault Value (after initialization)
Station Attributes2-245 Chapter 2 - Features and Operation Print Station Attributes Description The Print Station Attributes command dumps the entire database as a permanent record which can serve as a hardcopy of the database. The system baud rate must match that of the printer or receiving device. When printing the Station attributes the following data prints: >>>All Current Station Parameters Figure 2-18: Station Attributes Printout STATION ATTRIBUTES STA 100 STA 101 PAGE ACCESS ENABLED PAGE ACCESS ENABLED DO NOT DISTURB ENABLED DO NOT DISTURB ENABLED CONFERENCE ENABLED CONFERENCE ENABLED EXEC OVERRIDE DISABLED EXEC OVERRIDE DISABLED PRIVACY ENABLED PRIVACY ENABLED SYSTEM SPEED ENABLED SYSTEM SPEED ENABLED LINE QUEUING ENABLED LINE QUEUING ENABLED PREF LINE ANSWER DISABLED PREF LINE ANSWER DISABLED OFF HOOK VOICE OVER DISABLED OFF HOOK VOICE OVER DISABLED CALL FORWARD ENABLED CALL FORWARD ENABLED FORCE LCR DISABLED FORCE LCR DISABLED ACD SUPV BARGE IN DISABLED ACD SUPV BARGE IN DISABLED EXEC OVERRIDE BLOCK DISABLED EXEC OVERRIDE BLOCK DISABLED CO RING OPTIONS MUTED RING CO RING OPTIONS MUTED RING NAME AT IDLE LCD EXT NUMBER NAME AT IDLE LCD EXT NUMBER ACD ZAP TONE DISABLED ACD ZAP TONE DISABLED STATION ID KEYSET - SP 24BTN STATION ID KEYSET - SP 24BTN CO LOOP POOL FLEX DISABLED CO LOOP POOL FLEX DISABLED DAY COS 1 DAY COS 1 NIGHT COS 1 NIGHT COS 1 SPEAKERPHONE FULL SPEAKERPHONE SPEAKERPHONE FULL SPEAKERPHONE PICKUP GROUPS 1 PICKUP GROUPS 1 PAGE ZONE 1 PAGE ZONE 1 INTERNAL NO ANSWER ### INTERNAL NO ANSWER ### INTERNAL BUSY ### INTERNAL BUSY ### EXTERNAL NO ANSWER ### EXTERNAL NO ANSWER ### EXTERNAL BUSY ### EXTERNAL BUSY ### NO ANSWER TIMER 10 NO ANSWER TIMER 10 LINE GROUP ACCESS 1 LINE GROUP ACCESS 1 LCR CLASS OF SERVICE 0 LCR CLASS OF SERVICE 0 OFFHOOK PREFENCE BTN 00 ENABLED OFFHOOK PREFENCE BTN 00 ENABLED KEYSET MODE INACTIVE MODE 2400 KEYSET MODE INACTIVE MODE 2400 VOICE MAIL ID 100 VOICE MAIL ID 101 CORDLESS KEY BTN 00 LIGHT CONTROL NONE BUTTONS: DISPLAY LCD MSG NONE 01D100 02D101 03D102 CORDLESS KEY BTN 00 04D103 05D104 06D105 BUTTONS: 07D106 08D107 09D108 01100 02D101 03D102 10D109 11D110 12D111 04D10 05C001 06C002 13L001 14C002 15L003 07LP 08PL1 09CBK 16L004 17L005 18L006 10PKU 11DND 12LQU 19LP 20PL1 21CBK 13L001 14C002 15L003 22PKU 23DND 24LQU 16L004 17L005 18L006 25FLA 26XFR 27SPD 19LP 20PL1 21CBK 28CNF 29MSG 30FWD 22PKU 23DND 24LQU 31MUT 32CPO 33MON 34HLD 35VOL 36VOL ... and so on through all stations NOTE: The button printout for the 8-button keyset displays all flexible AND fixed buttons, the same as the 24-button keyset.
2-246Station Identification Chapter 2 - Features and Operation Programming Steps 1. Press the STATION ATTRIBUTES flexible button(FLASH 85, Button #3). The following message displays: 2. To print data for:
Station Identification2-247 Chapter 2 - Features and Operation 3. Press HOLD to save the entry. A confirmation tone sounds and the display updates. Flexible button #19 (Page A) is lit. 4. Pressbutton#20.ThedisplayupdatestoreflectcurrentprogrammingforPageB. XXX-XXX = Station Range 5. Press the STATION ID flexible button(FLASH 50, Page B, Button #1). 6. Enter a valid number on the dial pad to identify type of telephone: 7. Press HOLD to save the entry. A confirmation tone sounds and the display updates. DEFAULT…All Key Telephone Boards (DTIB) default to ID 006 (24-Button Digital Telephone), all Single Line Boards (SLIB) default to ID 6. Station ID Lock Description The Station ID Lock feature provides a means for the installer/programmer to lock the station ID of all stations in the system. After locked, attempts to plug unlike devices (e.g., a DSS into a 24-button port) results in the device not working. This feature is designed to prevent loss of station programming that results when a different station type is plugged into a port already designated as another station type. To change the Station ID with the Station ID Lock feature enabled: 1. Enter programming mode and disable the Station ID Lock feature. 2. Plug the new device type into the jack. The set is automatically identified. 3. Enter programming and perform Station ID programming (FLASH 50, Page B, Button #1). Set is automatically identified. 4. Enter programming mode and enable the Station ID Lock feature. XXX - XXX PAGE B ENTER BUTTON NUMBER STATION ID 0-8 KEYSET -SP24BTN [1-5] = DSS Console [007] = 12-Btn Phone [6] = SLT w/o Msg Wait [008] = 8-Btn Phone [7] = SLT w/Msg Wait (90 VDC) [015] = SLA [006] = 24-Btn Phone [016] = Lg Disp 30-Btn Phone
2-248 Station Message Detail Recording Chapter 2 - Features and Operation Programming Steps 1. PresstheSTATIONIDLOCKflexiblebutton(FLASH 06, Button #8). The following message displays: 2. Enter a 0 or 1 on the dial pad to enable/disable the use of this feature. [0] = Disabled [1] = Enabled 3. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT…Station ID Lock feature is disabled. Station Message Detail Recording Description TheXTSstation message detail recording (SMDR) provides details on both incoming and outgoing calls. This feature is programmable to allow recording of all calls or just outgoing long distance calls. The system tracks calls by outside line, number dialed, time-of-day, date, station that placed the call and duration of call. Account codes may also be entered and recorded. The SMDR Qualification Timer determines the length of time that is needed to determine a valid SMDR call for reporting purposes. By default, this timer is set to 30 seconds and is variable from 00 to 60 seconds in 1-second increments. This feature is enabled or disabled in system programming. By default, SMDR is not enabled and is set to record long distance calls only. A printout format of 80 characters maximum or 30 characters maximum may be selected in system programming. The standard format is 80 characters on a single line. A 30 character format generates 3 lines per message. If the SMDR feature is enabled, the system starts collecting information about the call as soon as it starts and terminates when the call ends. If the call was longer then 30 seconds, the following information is printed: STATION LOCK 0-1 DISABLED
Station Message Detail Recording 2-249 Chapter 2 - Features and Operation Figure 2-19: SMDR Printout 80 character format - Outbound Call to a Dialed Number: 12345678 12345678901234567890123456789012345678901234567890123456789012345678901234567890 AAAA BBB HH:MM:SS HH:MM MM/DD/YY HCCCCCCCCCCCCCCCCCCCCCCCC GGGGGGGGGGGG (CR)(LF) STA CO TOTAL START DATE DIALED 1100 001 00:00:38 13:57 01/15/01 O2956006 80 character format - Outbound Call to an Extension: 12345678 12345678901234567890123456789012345678901234567890123456789012345678901234567890 AAAA BBB HH:MM:SS HH:MM MM/DD/YY HCCCCCCCCCCCCCCCCCCCCCCCC GGGGGGGGGGGG (CR)(LF) STA CO TOTAL START DATE DIALED 1100 031 00:00:08 13:58 01/15/01 O2108 ** **CALL TO HOWARD 80 character format - Outbound Call to an Extension: 12345678 12345678901234567890123456789012345678901234567890123456789012345678901234567890 AAAA BBB HH:MM:SS HH:MM MM/DD/YY HCCCCCCCCCCCCCCCCCCCCCCCC GGGGGGGGGGGG (CR)(LF) STA CO TOTAL START DATE DIALED 1102 031 00:00:11 13:59 01/15/01 O2101 ** **CALL TO STA2101 80 character format - Inbound Call from an Extension: 12345678 12345678901234567890123456789012345678901234567890123456789012345678901234567890 AAAA BBB HH:MM:SS HH:MM MM/DD/YY HCCCCCCCCCCCCCCCCCCCCCCCC GGGGGGGGGGGG (CR)(LF) STA CO TOTAL START DATE DIALED 1100 031 00:00:03 13:59 01/15/01 I2108 ** **HOWARD CALLING - continued on next page - 80 character format - Inbound Call to a Station From CO Line 1 with No Caller ID: 12345678 12345678901234567890123456789012345678901234567890123456789012345678901234567890 AAAA BBB HH:MM:SS HH:MM MM/DD/YY HCCCCCCCCCCCCCCCCCCCCCCCC GGGGGGGGGGGG (CR)(LF) STA CO TOTAL START DATE DIALED 1100 001 00:00:04 13:59 01/15/01 I LEGEND: - AAAA = Station originator or Trunk on DISA and Off-Net (CO Line) calls. - BBB = Outside line number - HH:MM:SS = Duration of call in Hours, Minutes and Seconds - HH:MM = Time of day (start time) in Hours and Minutes - MM/DD/YY = Date of Call - H = Indicates call type: “I” = Incoming* “O” = Outgoing “T” = Transferred* “U” = Unanswered calls for ICLID SMDR call records - CC....CC = Number dialed - GG....GG = Last Account code entered (optional) - (CR) = Carriage return - (LF) = Line Feed
2-250 Station Message Detail Recording Chapter 2 - Features and Operation TheXTSsystem can provide SMDR output to the optional RS-232C connectors on the MISB. When SMDR is desired, the following system-wide parameters determine how SMDR information is reported. Programming Steps 1. PressFLASHand dial[21]. The following message displays: 2. To program SMDR features, use the flexible button(s) as defined in the following procedures. 3. The ENABLE/DISABLE, TYPE, and PRINT features toggle on and off each time the button is pressed. The display updates with each toggle. 4. After all entries are made, press HOLD to save the entry. A confirmation tone sounds. SMDR Enable / Disable Description A call accounting device can be installed allowing the system to track calls by outside line number, number dialed, time of day, date, station that placed or received the call, and duration of the call. Programming Steps 1. Press the ENABLE/DISABLE flexible button(FLASH 21, Button #1). This feature toggles on and off each time the button is pressed. The display updates with each toggle. LED ON = SMDR is enabled LED OFF = SMDR is disabled 2. Press HOLD to save the entry. A confirmation tone sounds. DEFAULT…SMDR is disabled. ENABLE / DISABLECALL TYPEPRINT FORMAT ✺1Q✺2W✺3E✺4R PORT ✺5T✺6Y✺7U✺8I SDR TPE PNT BAUD PORT NO LD 80 19.2K 1