    Have a look at the manual Starplus Triad Xts Installation Digital Key Telephone System Instructions Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 9 Triad manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 626
    							ISDN Programming - Page B2-171
    Chapter 2 - Features and Operation
    Programming Steps
    1. PressFLASHand dial[45]. The following message displays:
    2. Enter a valid number for the range of slots being programmed. If only one slot is being
    programmed, enter that number twice (02 02 = Slot 2, Cabinet 0).
    3. Press HOLD to save the entry. A confirmation tone sounds and the display updates.
    Flexible button #19 (Page A) is lit.
    4. Press button #20 to select Page B. The following message displays to indicate current
    programming of that slot or group of slots:
    XY-XY = Slot Range
    X = Cabinet (0, 1, 2)
    Y=Slot(0-8)
    NOTE -- Slot 8, Cabinet 0 is reserved for the MISB
    MAX # OF
    RETRANSMISSIONSMAX
    OCTETSMAX TEI
    RQSTMAX XID
    RETRANSMISSION
    ✺1Q✺2W✺3E✺4R
    T-200MIN TEI ID
    CHK MSGMIN TEI
    ID RQSTMSG EXCHANGE
    TIMER
    ✺5T✺6Y✺7U✺8I
    MIN XID
    RETRANSMINTER-DIGIT
    T/OSET UP
    TIMERDISCONNECT
    TIMER
    ✺9O✺10 P✺11 A✺12 S
    RELEASE
    REQUESTLINK
    DISCONNECTCALL
    PROCEEDINGCONNECT
    REQUEST
    ✺13 D✺14 F✺15 G✺16 H
    RESTART
    REQ TIMERPAGE APAGE B
    ✺17 J✺18 K✺19 L✺20 ;
    PAGE CPREVIOUSNEXTNEW RANGE
    ✺21 Z✺22 X✺23 C✺24 V
    ISDN ATTRIBUTES
    SELECT A SLOT RANGE
    XY - XY PAGE B
    ENTER BUTTON NUMBER 
    						
    							2-172ISDN Programming - Page B
    Chapter 2 - Features and Operation
    Maximum Number Retransmission
    Description
    The Maximum Number of Retransmissions of a frame (N200) is a system parameter. Do not
    change the Maximum Number Retransmission setting unless advised to do so by Technical
    Support.
    Programming Steps
    1. Press the MAX # RETRANSMSN flexible button(FLASH 45, Page B, Button #1).
    2. Enter a valid number (0-9) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Maximum Number Retransmission is 3.
    Maximum Octets
    Description
    The maximum number of octets in an I-Frame/information field (N201) is a system parameter.
    Do not change the Maximum Octets setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the MAX OCTETS flexible button(FLASH 45, Page B, Button #2).
    2. Enter a valid number (000-999) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    (000 = Disable)
    DEFAULT…Maximum Octet setting is 260.
    MAX # RETRANSMSN 0-9
    N200 3
    MAX OCTETS 000-999
    N201 260 
    						
    							ISDN Programming - Page B2-173
    Chapter 2 - Features and Operation
    Maximum TEI Request
    Description
    This feature is reserved for future use.
    Programming Steps
    1. Press the MAX TEI RQST flexible button(FLASH 45, Page B, Button #3).
    2. Enter a valid number (000-999) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Maximum TEI Request setting is 003.
    Maximum XID Retransmission
    Description
    Do not change the Maximum number of XID Retransmissions setting unless advised to do so
    by Technical Support.
    Programming Steps
    1. Press the MAX XID RETRANSMISSION flexible button(FLASH 45, Page B, Button #4).
    2. Enter a valid number (0-9 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Maximum XID Retransmission setting is 3 seconds.
    T-200
    Description
    TheT-200timerisusedtosetthetimetowaitforanI-Frameacknowledgement.Donot
    change the T-200 timer setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the T-200 flexible button(FLASH 45, Page B, Button #5).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    MAX TEI RQST 000-999
    N202 003
    MAX XID RETRANSMSN 0-9
    N204 3
    T200 00-99
    01 
    						
    							2-174ISDN Programming - Page B
    Chapter 2 - Features and Operation
    DEFAULT…T200 setting is 1 second.
    Minimum TEI ID Check Message
    Description
    The Minimum TEI ID Check Message feature sets the minimum time between retransmission
    of the TEI identity check messages. Do not change the Minimum TEI ID Check Message
    setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the MIN TEI ID CHK MSG flexible button(FLASH 45, Page B, Button #6).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Minimum TEI ID Check Message setting is 1 second.
    Minimum TEI ID Request
    Description
    This feature is reserved for future use.
    Programming Steps
    1. Press the MIN TEI ID RQST flexible button(FLASH 45, Page B, Button #7).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Minimum TEI ID Request setting is 2 seconds.
    Message Exchange Timer
    Description
    The Message Exchange Timer setting establishes the maximum time allowed without frames
    being exchanged. Do not change the Message Exchange Timer setting unless advised to do
    so by Technical Support.
    MIN TEI ID CHK MSG 00-99
    T201 01
    MIN TEI ID RQST MSG 00-99
    T202 02 
    						
    							ISDN Programming - Page B2-175
    Chapter 2 - Features and Operation
    Programming Steps
    1. Press the MSG EXCHANGE TIMER flexible button(FLASH45,PageB,Button#8).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Message Exchange Timer setting is 15 seconds.
    Minimum XID Retransmission
    Description
    The Minimum XID Retransmission setting establishes the minimum time between XID
    messages. Do not change the Minimum XID Retransmission setting unless advised to do so
    by Technical Support.
    Programming Steps
    1. Press the MIN XID RETRANSMSN flexible button(FLASH 45, Page B, Button #9).
    2. Enter a valid number (0-9 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Minimum XID Retransmission setting is 3 seconds.
    Inter-Digit T / O
    Description
    Do not change the Inter-digit time out setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the INTER-DIGIT T/O flexible button(FLASH 45, Page B, Button #10).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Inter-digit Timeout setting is 25 seconds.
    MSG EXCHANGE TIMER 00-99
    T203 15
    MIN XID RETRANSMSN 0-9
    T204 3
    INTER-DIGIT T/O 00-99
    T302 25 
    						
    							2-176ISDN Programming - Page B
    Chapter 2 - Features and Operation
    Set-Up Timer
    Description
    The Set-up Timer setting establishes the response time to setup message. Do not change the
    Set-up Timer setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the SET UP TIMER flexible button(FLASH 45, Page B, Button #11).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Set-up Timer setting is 10 seconds
    Disconnect Timer
    Description
    The Disconnect Timer setting establishes the response time to a disconnect message. Do not
    change the Disconnect Timer setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the DISCONNECT TIMER flexible button(FLASH 45, Page B, Button #12).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Disconnect Timer setting is 4 seconds.
    SETUP TIMER 00-99
    T303 10
    DISCONNECT TIMER 00-99
    T305 04 
    						
    							ISDN Programming - Page B2-177
    Chapter 2 - Features and Operation
    Release Request
    Description
    Do not change the Release Request setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the RELEASE REQUEST flexible button(FLASH 45, Page B, Button #13).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Release Request Timer setting is 4 seconds.
    Link Disconnect
    Description
    Do not change the Link Disconnect Timer setting unless advised to do so by Technical
    Support.
    Programming Steps
    1. Press the LINK DISCONNECT flexible button(FLASH 45, Page B, Button #14).
    2. Enter a valid number (20-30 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Link Disconnect setting is 30 seconds.
    Call Proceeding
    Description
    Do not change the Call Proceeding setting unless advised to do so by Technical Support.
    Programming Steps
    1. Press the CALL PROCEEDING flexible button(FLASH45,PageB,Button#15).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Call Proceeding setting is 60 seconds.
    RELEASE REQUEST 00-99
    T308 04
    LINK DISCONNECT 20-30
    T309 30
    CALL PROCEEDING 00-99
    T310 60 
    						
    							2-178ISDN Programming - Page B
    Chapter 2 - Features and Operation
    Connect Request
    Description
    Do not change the Connect Request Timer setting unless advised to do so by Technical
    Support.
    Programming Steps
    1. Press the CONNECT REQUEST flexible button(FLASH 45, Page B, Button #16).
    2. Enter a valid number (00-99 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Connect Request setting is 4 seconds.
    Restart Request Timer
    Description
    Do not change the Restart Request Timer setting unless advised to do so by Technical
    Support.
    Programming Steps
    1. Press the RESTART REQ TIMER flexible button(FLASH 45, Page B, Button #17).
    2. Enter a valid number (0-200 seconds) on the dial pad.
    3. Press the HOLD button. A confirmation tone sounds and the display updates.
    DEFAULT…Restart Request Timer setting is 120 seconds.
    CONNECT REQUEST 00-99
    T313 04
    RESTART REQ TIMER 0-200
    T316 120 
    						
    							ISDN Programming - Page B2-179
    Chapter 2 - Features and Operation
    Initialize ISDN/VoIP Parameters
    Description
    The ISDN/VoIP Parameters may be initialized setting all data fields to their original, default
    values.
    Table 2-15: ISDN Parameter Defaults
    Program
    CodeFlexible
    ButtonFeaturesDefault Value
    (after initialization)
    FLASH 45
    PA G E AISDN PARAMETERS
    1BRICOType NI1
    2 PRI CO Type NI2
    3Framing ESF
    4 NT/TE Mode TE
    5 Power Disabled
    6 Directory Number None
    7 Max Out I-Frames K 001
    8 Leading 1 Enabled
    9 Leading 011 Enabled
    10 7/8 Digit Number Plan ITU
    11 Calling Number Enabled
    12 Loopback Normal
    13 10 Digit Number Plan ITU
    14 11 Digit Number Plan ITU 
    						
    							2-180ISDN Programming - Page B
    Chapter 2 - Features and Operation
    Programming Steps
    1. Press the ISDN/VOIP flexible button (FLASH 80, Button #15). The following message
    displays:
    2. Press the HOLD button. A confirmation tone sounds.
    PAGE B 1 Maximum Number Retransmission 3
    2 Maximum Octets 260
    3 Maximum TEI ID Request 003
    4 Maximum XID Retransmission 3 sec
    5 T-200 01 sec
    6 Minimum TEI ID Check Message 01 sec
    7 Minimum TEI ID Request 02 sec
    8 Message Exchange Timer 15 sec
    9 Minimum XID Retransmission 3 sec
    10 Inter Digit T/O 25 sec
    11 Set-up Timer 10 sec
    12 Disconnect Timer 04 sec
    13 Release Request 04 sec
    14 Link Disconnect 30 sec
    15 Call Proceeding 60 sec
    16 Connect Request 04 sec
    17 Restart Request Timer 120 sec
    FLASH 46 VOIP NETWORK PROGRAMMING
    1 IP Address None
    2SubnetMask None
    3 Router IP Address None
    4 Domain Name None
    5 Vocoder Value G.723.1
    INITIALIZE ISDN / VOIP
    PRESS HOLD
    Table 2-15: ISDN Parameter Defaults
    Program
    CodeFlexible
    ButtonFeaturesDefault Value
    (after initialization) 
    						
    All Triad manuals Comments (0)

    Related Manuals for Starplus Triad Xts Installation Digital Key Telephone System Instructions Guide