    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 117
    Call Forwarding - Busy Line - DtermC-2D
    Service Conditions (cont’d)
    b.) When the calling party is the attendant console or the night station, and the destination of the
    CALL FORWARDING - BUSY LINE service is also the attendant console or the night station.
    26. SPLIT CALL FORWARDING [S-99] is available only when the calling party is the station or the CCIS
    line.
    27. The OAI monitor number and the ACD pilot number cannot be assigned as the Call Forwarding target
    telephone number except when called from a station or Tie Line trunk.
    28. Telephone number must be set to the call forwarding destination.
    29. This feature is not available for stations having a telephone number of seven digits or more.
    30. A call can be forwarded to an Attendant Console in the remote node via FCCS link.
    31. When a call is forwarded through FCCS link, the numbering plan of the originally called station must be
    identical with that of the forwarded Attendant Console.
    Interactions
    1. If the same access code is used for CALL FORWARDING - BUSY LINE - Dterm and CALL
    FORWARDING - DON’T ANSWER [C-3], only one key needs to be assigned in AKYD.
    2. An ATTENDANT CAMP-ON [A-1] call is terminated at Station A, and Station A has CALL
    FORWARDING - BUSY LINE - D
    term set to Station B. If Station B is busy and part of a STATION
    HUNTING [S-7, 8, 9] Group, the call will Camp-On at Station A and will not Hunt.
    3. When CALL WAITING [C-12, 31], ATTENDANT CAMP-ON [A-1], and CALL BACK [C-1] is
    directed toward Station A, which has call forwarding set to Station B, and Station B is busy, Station A will
    receive Call Waiting Tone.
    4. A non-controlling UCD station is allowed to activate CALL FORWARDING - BUSY LINE - D
    term [C-
    2]. When this station sets CALL FORWARDING - BUSY LINE - Dterm, only calls that are directly dialed
    to this station are call forwarded.
    5. The Attendant attempts BUSY VERIFICATION [B-3] to Station A. Station A has CALL
    FORWARDING - BUSY LINE - D
    term set to Station B. Station B is busy. BUSY VERIFICATION is
    allowed at Station A. If Station A has set CALL FORWARDING - BUSY LINE - Dterm to the Attendant
    Console, BUSY VERIFICATION [B-3] is allowed at Station A.
    6. When CALL FORWARDING - BUSY LINE - D
    term is in effect, the activating station may be used to
    originate calls.
    7. When a call follows call forwarding, the destination station is recorded for STATION MESSAGE
    DETAIL RECORDING [S-10].
    8. STATION-TO-STATION CALLING [S-11] must be provided.
    TKNode ANode B
    FCCS LinkStation A has been set
    Call Forwarding service to
    Attendant Console B
    Attendant
    Console B 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 118ND-70184 (E), Issue 3
    C-2D Call Forwarding - Busy Line - Dterm
    Programming
    STEP 1:ASYD - System Data 1, Index 5, Bit 0. Access codes for CALL FORWARDING BUSY LINE - Dterm
    and CALL FORWARDING - DON’T ANSWER [C-3] are same or separate? 0/1: Same/Separate.
    System Data 1, Index 69, Bit 5, Index 69, Bit 7.
    STEP 2:ANPD - Reserve a number level for feature access and cancel. Assign for Normal (N), Hooking (H),
    and BUSY (B). Assign NND in accordance with a predetermined numbering plan.
    STEP 3:ASPA - Assign an access code to CALL FORWARDING - BUSY LINE - D
    term entry, SID = 10 and
    to CALL FORWARDING-BUSY LINE-Dterm cancel SID = 11. Assign Connection Status Index (CI)
    for Normal (N) service.
    STEP 4:ASFC - Assign a Service Feature Class that allows SFI = 9 to the stations that receive CALL
    FORWARDING-BUSY LINE-D
    term.
    STEP 5:AKYD - For D
    term sets, CALL FORWARDING-BUSY LINE-Dterm may be assigned to a
    programmable line/feature key. Assign 
    Type:Function:CALL FORWARDING-BUSY LINE [1].
    STEP 6:ADSL - Assign SN=3 (Called Station is Busy) and FKY=1 (Call Forwarding - Busy Line; FDB)
    This command is required only for assigning the function to each soft key.
    STEP 7:AT N R - Allow tenant-to-tenant connection for Inter and Intra-tenant connections. Assign Tenant
    Restriction Index (TRI) = 1. For this feature to be set, assign Inter and Intra-Tenant connection TRI =
    3 from the Attendant Console. This allows a station in one tenant group to be call forwarded to a
    station in the same or different tenant group. Also assign TRI = 0, station-to-station calling.
    STEP 8:ACFO - For tenant-wide CALL FORWARDING-BUSY LINE - D
    term of incoming DID and DIT
    calls, assign CF = 1 for a destination (CFI) of either the Attendant Console or a station.
    FCCS Programming 
    This data setting describes only the additional or replacement commands used to activate FCCS
    services. When used as an FCCS feature, these commands replace the non-network commands (for
    example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
    on the node. 
    (Note 1)
    STEP 1:ASYDL - This data must be assigned to the node set Call Forwarding service.
    System Data 1, Index 640: Assign the FPC of the node providing the attendant console.
    Note 1:
    When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required in addition
    to ASYDL or ASYDN.
    Note 2:
    The data of the ASFC command is assigned to the node set Call Forwarding service. 
    						
    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 119
    Call Forwarding - Don’t Answer C-3
    C-3 Call Forwarding - Don’t Answer
    General Description
    This feature permits a call to an unanswered station to be forwarded to a predesignated station, or to the Attendant,
    when the called station doesnt answer after a predetermined time interval. If the individual Call Forwarding - Don’t
    Answer timer is not assigned, the default timer assigned by system data programming is used.
    Operating Procedure
    To set CALL FORWARDING - DONT ANSWER from an individual station:
    1. Lift the handset; receive dial tone.
    2. Dial the specific CALL FORWARDING - DONT ANSWER access code; receive special dial tone.
    3. Dial the desired target telephone number; receive service set tone.
    To cancel CALL FORWARDING - DONT ANSWER from an individual station:
    1. Lift the handset; receive dial tone.
    2. Dial the specific CALL FORWARDING - DONT ANSWER cancel code; receive service set tone.
    To set CALL FORWARDING - DONT ANSWER from the ATTENDANT CONSOLE [A-3]: 
    1. Press an idle loop key.
    2. Dial the specific CALL FORWARDING - DONT ANSWER access code; receive special dial tone.
    3. Dial the TENANT [T-12] number (2/3 digits).
    4. Dial the originating telephone number.
    5. Dial the desired target telephone number; receive service set tone.
    To cancel CALL FORWARDING - DONT ANSWER from the ATTENDANT CONSOLE [A-3]: 
    1. Press an idle loop key.
    2. Dial the specific CALL FORWARDING - DONT ANSWER cancel code; receive special dial tone.
    3. Dial the TENANT [T-12] number (2/3 digits). 
    4. Dial the originating telephone number; receive service set tone.
    To assign individual Call Forwarding - Don’t Answer timer to each station:
    1. Use the ADAI command:
    a.) Parameter NAT139 overrides SYS-1, Index 139 of ASYD
    b.) Parameter NAT140 overrides SYS-1, Index 140 of ASYD
    c.) Parameter NAT141 overrides SYS-1, Index 141 of ASYD
    d.) Parameter NAT247 overrides SYS-1, Index 247 of ASYD
    2. Timer assigned to called party is valid.
    Service Conditions
    1. This feature may be set and cancelled by either the user or the Attendant.
    2. When the Attendant extends a call to a station that has set CALL FORWARDING - DONT ANSWER,
    the called station will ring for 10 seconds. If the call is not answered, AUTOMATIC RECALL [A-8] is
    activated. This timing can be changed through the VARIABLE TIMING PARAMETERS [V-1] feature.
    3. This feature is assigned by CLASS OF SERVICE - INDIVIDUAL [C-15] programming in System Data.
    4. A station programmed for access to CALL FORWARDING - DONT ANSWER is automatically allowed
    CALL FORWARDING - BUSY LINE [C-2, 2D].
    5. There is no limitation to the number of stations that can set the CALL FORWARDING - DONT
    ANSWER simultaneously. 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 120ND-70184 (E), Issue 3
    C-3 Call Forwarding - Don’t Answer
    Service Conditions (cont’d)
    6. CALL FORWARDING - DONT ANSWER can be provided on either a tenant or an individual basis.
    7. Individual CALL FORWARDING - DONT ANSWER takes precedence over tenant basis Call
    Forwarding.
    8. Call Forwarding on a tenant basis allows direct incoming trunk calls that encounter a Dont Answer
    condition to be forwarded to a predetermined station or the ATTENDANT CONSOLE [A-3].
    9. The operator answering a Call Forwarding call can identify the called telephone number on the
    ATTENDANT CONSOLE [A-3] display.
    10. CALL FORWARDING - DONT ANSWER from the Attendant is only activated after pressing the
    RELEASE key.
    11. If the stations own telephone number is set for CALL FORWARDING - DONT ANSWER, then this
    feature is changed to CALLING PARTY RECOGNITION SERVICE (CALL FORWARDING - DONT
    ANSWER [C-103]).
    12. When the called station does not answer for a predetermined time interval, stations are assigned this
    feature according to the TENANT SERVICE [T-12] class of the calling and destination stations. In the
    following cases, when the calling station and destination station are restricted by TENANT SERVICE [T-
    12] class, this feature is not activated, and the called station continues to ring: 
    a.) when the station called is setting CALL FORWARDING - DONT ANSWER,
    b.) when a station holding an original call (station or trunk) on CONSULTATION HOLD [C-17]
    places a call to a station setting CALL FORWARDING - DONT ANSWER.
    13. Call Transfer - Attendant (Trunk): Trunk calls transferred by the Attendant are assigned this feature when
    the called station does not answer for a predetermined time interval according to Route Restriction Class
    of the trunk and the destination stations. When restricted by Route Restriction Class, this feature is not
    activated, and the called station continues to ring.
    14. Call Transfer - Attendant (Station): Station calls transferred by the Attendant are assigned this feature
    when the called station does not answer for a predetermined time interval according to TENANT
    SERVICE [T-12] class of the originating and destination stations. When restricted by Tenant Service
    class, this feature is not activated, and the called station continues to ring.
    15. Speed Calling List numbers may be programmed as the destination telephone number. This permits the
    sent digits to exceed the 12-digit maximum.
    16. CALL FORWARDING - DONT ANSWER data remains in the data memory, even if the system or LP is
    reinitialized.
    17. SPLIT CALL FORWARDING [S-99]: When a call is forwarded to the parties predesignated by SPLIT
    CALL FORWARDING [S-99], service conditions are the same as described in items 12, 13, and 14.
    18. When a call is transferred from the Attendant to a station that has set CALL FORWARDING - DONT
    ANSWER, this feature may be restricted or activated according to System Data (Sys 2, Index 6, Bit 7).
    19. A call can be forwarded to an Attendant Console in the remote node via FCCS link.
    TKNode ANode B
    FCCS LinkStation A has been set
    Call Forwarding service to
    Attendant Console B
    Attendant
    Console B 
    						
    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 121
    Call Forwarding - Don’t Answer C-3
    Service Conditions (cont’d)
    20. When a call is forwarded through FCCS link, the numbering plan of the originally called station must be
    identical with the one of the forwarded Attendant Console.
    21. If individual Call Forwarding - Don’t Answer timer is not given, the default timer assigned by ASYD
    command is used.
    Interactions
    1. If access codes for CALL FORWARDING-BUSY LINE and CALL FORWARDING-DON’T ANSWER
    are the same, only one key needs to be assigned in AKYD.
    2. ACFO is applicable to DID, DIT, and TIE Line calls only.
    3. A non-controlling UCD station is allowed to activate CALL FORWARDING-DON’T ANSWER. When
    this station sets call forwarding, calls directed to this station will be call forwarded. The member station
    is not removed from the UCD group under the conditions of the call forwarding feature used. When it is
    the station’s turn to ring, that call is affected by CALL FORWARDING-DON’T ANSWER.
    4. CALL FORWARDING-DON’T ANSWER to an Attendant Console will not operate when the system is
    in Night mode. If ATTENDANT NIGHT TRANSFER [A-19] is provided, the call is forwarded to the
    ATTENDANT NIGHT TRANSFER [A-19] station.
    5. If the CALL FORWARDING-DON’T ANSWER target station is a D
    term that has activated DO NOT
    DISTURB [D-21D], call forwarding is not activated.
    6. The CALL FORWARDING-DON’T ANSWER feature is set from Station A to Station B if Station A is
    idle and Station B is busy.
    7. When a call is Call Forwarded, the destination station is recorded for STATION MESSAGE DETAIL
    RECORDING [S-10].
    8. STATION-TO-STATION CALLING [S-11] must first be provided.
    Programming
    STEP 1:ASYD - System Data 1, Index 5, Bit 0. Are the access codes for CALL FORWARDING - BUSY
    LINE [C-2] and CALL FORWARDING - DON’T ANSWER the same or separate? 0/1: Same/
    Separate.
    System Data 1, Index 69, Bit 1 and 2 is a short tone to alert person receiving the call that this is a
    CALL FORWARDING-DON’T ANSWER call? 0/1: No/Yes.
    System Data 1, Index 139. Assign the No Answer timer for station-to-station, DID and TIE Line calls.
    For 30 seconds, assign 00H. [RAM data is 3FH].
    System Data 1, Index 141. Assign the No Answer timer for incoming calls via the Attendant Console.
    It will then be forwarded to the next station according to SYS1, Index 145 timer. For 10 seconds assign
    00H. [RAM data is 3FH.]
    System Data 1, Index 141. Assign the No Answer timer for incoming calls via the Attendant console. It
    will then be forwarded to the next station according to SYS1, Index 145 timer. For 10 seconds, assign
    00H. [RAM data is 35H.]
    System Data 1, Index 145. Assign the time an incoming call via the Attendant Console will ring at the
    CALL FORWARDING-DON’T ANSWER station before recalling to the Attendant console. For 30
    seconds, assign 00H. [RAM data is 9FH.]
    System Data 2, Index 6, Bit 7. Enable CALL FORWARDING-DON’T ANSWER via the Attendant
    Console. 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 122ND-70184 (E), Issue 3
    C-3 Call Forwarding - Don’t Answer
    Programming (cont’d)
    STEP 2:ANPD - Reserve a number level for feature access and cancel. Assign Connection Index (CI) = N, H,
    B; Normal, Hooking, and Busy (in order to be applicable to any feature assigned to this level). Assign
    NND in accordance with a predetermined numbering plan.
    STEP 3:ASPA - Assign an access code to CALL FORWARDING-DON’T ANSWER entry, SID = 12, and to
    CALL FORWARDING-DON’T ANSWER cancel, SID = 13. Assign CI for Normal (N) service.
    STEP 4:ASFC - Assign the stations to receive CALL FORWARDING-DON’T ANSWER a Service Feature
    Class that allows SFI = 8.
    STEP 5:AKYD - For D
    term sets, CALL FORWARDING-DON’T ANSWER may be assigned to a
    programmable line/feature key. Assign Type:Function:CALL FORWARD-DON’T ANSWER [22].
    STEP 6:AT N R - Allow tenant-to-tenant connection for Inter and Intra-tenant connections. Assign Tenant
    Restriction Index (TRI) = 1. For this service feature to be set by the Attendant Console, assign Inter
    and Intra-Tenant connection via the Attendant Console, TRI = 3. Also assign TRI = 0, station-to-
    station calling.
    CFI of either the Attendant Console or a station.
    STEP 7:ACFO - For tenant-wide CALL FORWARDING-DON’T ANSWER, assign CF = 2 for a destination
    STEP 8:ACFS - Call Forwarding can also be assigned via the ACFS command.
    STEP 9:ADAI - Assign NAT139, NAT140, NAT141 and NAT247 for Individual Call Forwarding - Don’t
    Answer Timer.
    Service Version Index (SVI) allow SVI 1439, Individual Call Forwarding - Don’t Answer Timer.
    Binary:0/1=-/enable
    FCCS Programming 
    This data setting describes only the additional or replacement commands used to activate FCCS
    services. When used as an FCCS feature, these commands replace the non-network commands (for
    example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
    on the node. 
    (Note 1)
    STEP 1:ASYDL - This data must be assigned to the node set Call Forwarding service.
    System Data 1, Index 640: Assign the FPC of the node providing the attendant console.
    Note 1:
    When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required in addition
    to ASYDL or ASYDN.
    Note 2:
    The data of the ASFC command is assigned to the node set Call Forwarding service. 
    						
    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 123
    Call Forwarding - Don’t Answer - DtermC-3D
    C-3D  Call Forwarding - Don’t Answer - Dterm
    General Description
    This feature permits a call to an unanswered station to be forwarded to a predesignated station or to the Attendant,
    if the called station does not answer within a predetermined period of time. CALL FORWARDING - DONT
    ANSWER - D
    term may be set or cancelled by the user for all multi-line appearances on the Dterm. Additionally, a
    single station user may set CALL FORWARDING - DONT ANSWER - Dterm to all sub-lines on the Dterm.
    Operating Procedure
    To set CALL FORWARDING - DONT ANSWER Dterm from MY Line:
    1. Lift the handset or press the SPEAKER key; receive dial tone.
    2. Press the CALL FORWARDING - DONT ANSWER FORWARD-NA key; receive special dial tone.
    3. Dial the desired target telephone number; receive service set tone. The LCD displays:
    Target Station
    To monitor CALL FORWARDING - DONT ANSWER from a Dterm from MY Line:
    1. Press the CALL FORWARDING - DONT ANSWER FORWARD-NA key. The LCD displays:
    OR
    To set CALL FORWARDING - DONT ANSWER for a multi-line appearance other than the MY Line:
    1. Lift the handset or press the SPEAKER key.
    2. Press the multi-line appearance; receive dial tone. Press the CALL FORWARDING - DONT ANSWER
    FORWARD-NA key; receive special dial tone.
    3. Dial the desired target telephone number; receive service set tone. The LED of the associated feature
    button does not light at the station setting the service. If the multi-line appearance is another D
    terms MY
    Line, that stations feature key LED will light. The setting stations LCD displays:
    Target Station:
    4. Replace the handset or press the SPEAKER key. FORWARD SET
    XXXX
                       (Time Display) 
    FORWARD  
                                        XXXX     
              (Time Display)        
    FWD SET 
                       (Time Display) 
    FORWARD SET
    XXXX
                        (Time Display)  
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 124ND-70184 (E), Issue 3
    C-3D Call Forwarding - Don’t Answer - Dterm
    Operating Procedure (cont’d)
    5.  If t h e t a rg et  s ta ti on is  t h e A tt e nd an t,  t h e  LC D  d is p la y s:
    To monitor CALL FORWARDING - DONT ANSWER for a multi-line appearance other than the MY Line:
    1. Press the CALL FORWARDING - DONT ANSWER FORWARD-NA key. The LCD displays:
    Target Station 
    To cancel CALL FORWARDING - DONT ANSWER from MY Line:
    1. Lift the handset or press the SPEAKER key; receive dial tone.
    2. Press the CALL FORWARDING - DONT ANSWER FORWARD-NA key. The associated LED goes
    out. Receive service set tone. The LCD displays:
    To cancel CALL FORWARDING - DONT ANSWER for a multi-line appearance other than the MY Line:
    1. Lift the handset or press the SPEAKER key.
    2. Press the multi-line appearance; receive dial tone. Press the CALL FORWARDING - DONT ANSWERFORWARD-NA key; receive service set tone. The LCD displays:
    The associated LED that is lit at another station goes out.
    3. Replace the handset or press the SPEAKER key.
    Service Conditions
    1. This feature may be set and cancelled by the Dterm user or the Attendant.
    2. AUTOMATIC RECALL [A-8] supersedes the timing for CALL FORWARDING -  DON’T ANSWER -
    D
    term. Therefore, if the programmed timing for AUTOMATIC RECALL [A-8] is shorter than the
    programmed timing for CALL FORWARDING - DONT ANSWER - Dterm, CALL FORWARDING -
    DONT ANSWER - Dterm is disabled.
    3. Stations are assigned this feature according to CLASS OF SERVICE - INDIVIDUAL [C-15] programming in System Data.
    4. A station programmed for access to CALL FORWARDING -  DONT ANSWER - D
    term is automatically
    allowed CALL FORWARDING - BUSY LINE [C-2].
    5. All stations may simultaneously activate CALL FORWARDING - DONT ANSWER - D
    term.
    6. If separate access codes are programmed into System Data for CALL FORWARDING - DONT ANSWER - D
    term and CALL FORWARDING - BUSY LINE [C-2], each feature must be programmed
    on a separate feature button at the Dterm.
    FWD SET OPR
                        (Time Display) 
    FORWARD
    XXXX
                        (Time Display) 
    FORWARD CANCEL
                       (Time Display) 
    FORWARD CANCEL
                       (Time Display)  
    						
    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 125
    Call Forwarding - Don’t Answer - DtermC-3D
    Service Conditions (cont’d)
    7. CALL FORWARDING - DONT ANSWER - Dterm may also be accessed via the dial pad or SPEED
    CALLING - ONE TOUCH - Dterm [S-26D]. If this feature is accessed via the dial pad, it must be cancelled
    via the dial pad.
    8. CALL FORWARDING - DONT ANSWER - D
    term is not applicable to CONSULTATION HOLD - ALL
    CALLS [C-17], and CALL TRANSFER - ALL CALLS [C-11].
    9. A user may set CALL FORWARDING - DONT ANSWER - D
    term for a multi-line appearance based on
    the CLASS OF SERVICE - INDIVIDUAL [C-15] as assigned to the station (MY Line) setting the service.
    The figure below is a simplified key sheet assignment for stations 200 & 201. The CLASS OF SERVICE
    - INDIVIDUAL [C-15] for station 200 is allowed CALL FORWARDING - DONT ANSWER - D
    term,
    but the CLASS OF SERVICE - INDIVIDUAL [C-15] for station 201 is not. Station 200 is able to set
    CALL FORWARDING - DONT ANSWER - D
    term for station 201. The associated feature button LED
    on station 201 will illuminate.
    Note:
    FORWARD-NA key is same as the CALL FORWARDING - DONT ANSWER feature key.
    Even when a sub-line of Dterm is assigned as the destination station, the call is not forwarded if the MY
    Line of that Dterm is not allowed CALL FORWARDING - DONT ANSWER - Dterm.
    10. This feature is applicable to CALL FORWARDING - ALL CALLS - OUTSIDE [C-28], CALL
    FORWARDING - DONT ANSWER - CCIS [C-47], and MULTIPLE CALL FORWARDING -DONT
    ANSWER - CCIS [M-42].
    11. The display of an intermediate station on a D
    terms LCD panel may be allowed or denied according to
    System Data. This arrangement is done on a system basis. The LCD displays:
    Intermediate Station           Calling/Called Station:
    Note:
    When the telephone number of the intermediate or calling/called station exceeds 8 digits, the last 8 digits are
    displayed. However, a maximum of 16 digits calling/called telephone number can be displayed on the middle line of
    LCD depending on the System Data.
    12. Stations are assigned this feature according to TENANT SERVICE [T-12] of the calling and destination
    stations, when the called station does not answer for a predetermined time interval. In the following cases,
    when the calling or destination stations are restricted by TENANT SERVICE [T-12] class, this feature is
    not activated, and the called station continues to ring:
    a.) when a station places a call to another station setting CALL FORWARDING - DONT
    ANSWER,
    MY LINE MULTI-LINE MY LINE MULTI-LINE Station 200 Station 201
    FORWARD-NA FORWARD-NA
    CF NANS XXXX
    (Time Display)XXXX 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 126ND-70184 (E), Issue 3
    C-3D Call Forwarding - Don’t Answer - Dterm
    Service Conditions (cont’d)
    b.) when a station holding an original call (station or trunk) on CONSULTATION HOLD [C-17]
    places a call to a station setting CALL FORWARDING - DONT ANSWER.
    13. Call Transfer - Attendant (Trunk): Trunk calls transferred by the Attendant are assigned this feature
    according to Route Restriction Class of the trunk and the destination station when the station does not
    answer for a predetermined time interval. When restricted by Route Restriction Class, this feature is not
    activated, and the called station continues to ring.
    14. Call Transfer - Attendant (Station): Station calls transferred by the Attendant are assigned this feature
    according to TENANT SERVICE [T-12] class of the originating and destination stations when the called
    station does not answer for a predetermined time interval. When restricted by TENANT SERVICE class,
    this feature is not activated, and the called station continues to ring.
    15. Speed Calling List numbers may be programmed as the destination telephone number. This permits the
    sent digits to exceed the 12-digit maximum.
    16. CALL FORWARDING - DONT ANSWER data remains in the data memory, even if the system or LP is
    reinitialized.
    17. When a call is transferred from the Attendant to a station that has set CALL FORWARDING - DONT
    ANSWER, this feature may be restricted or activated according to System Data (SYS2, INDEX6, BIT7).
    18. A call can be forwarded to an Attendant Console in the remote node via FCCS link.
    19. When a call is forwarded through FCCS link, the numbering plan of the originally called station must be
    identical with that of the forwarded Attendant Console.
    Interactions
    1. If access code for CALL FORWARDING-BUSY LINE [C-2] and CALL FORWARDING-DON’T
    ANSWER-Dterm are the same, only one key needs to be assigned in AKYD.
    2. ACFO is applicable to DID, DIT, and TIE Line calls only.
    3. A non-controlling UCD station is allowed to activate CALL FORWARDING-DON’T ANSWER-D
    term.
    When this station sets Call Forwarding, calls directed to this station will be call forwarded. The member
    station is not removed from the UCD group under the conditions of which the Call Forwarding feature is
    used. When it is the station’s turn to ring, that call is affected by CALL FORWARDING-DON’T
    ANSWER - D
    term.
    4. CALL FORWARDING-DON’T ANSWER-D
    term to an Attendant Console will not operate when the
    system is in Night mode. If ATTENDANT NIGHT TRANSFER [A-19] is provided, the call is forwarded
    to the ATTENDANT NIGHT TRANSFER [A-19] station.
    5. If the CALL FORWARDING-DON’T ANSWER-D
    term target station is a Dterm and DO NOT DISTURB
    [D-21D] has been set, Call Forwarding is not activated. The station will ring, and the timer setting in
    System Data 1, Index 145 is ignored.
    TKNode ANode B
    FCCS LinkStation A has been set
    Call Forwarding service to
    Attendant Console B
    Attendant
    Console B 
    						