    							NEAX2400 IMX Feature Programming Manual
    ND-70184 (E), Issue 3
    Page 997
    Voice Call - CCIS V-7
    V-7  Voice Call - CCIS
    General Description
    This service feature allows Inter-office VOICE CALL when the calling Dterm/Single-line Station and the called
    Dterm belong to different PBX’s in the CCIS network.
    Operating Procedure
    From a Dterm to a Dterm:
    1. Dterm (a) places a call to Dterm (b) through a CCIS line; receives ringback tone. Dterm (b) rings.
    2. D
    term (b) still does not answer. Dterm (a), then presses the VOICE key and sends a tone to Dterm (b). The
    LCD on Dterm (a) displays:
    Note:
    If Dterm (a) turns on MIC key on the Dterm, Dterm (a) can talk with Dterm (b) hands-free.
    3. Dterm (a) talks with Dterm (b) via the speaker.
    Note:
    If Dterm (b) turns on MIC key on the Dterm, Dterm (b) can talk with Dterm (a) hands-free.
    From a single-line station to a D
    term:
    1. Station (a) places a call to Dterm (b) through a CCIS line and receives ringback tone while Dterm (b) is
    ringing.
     NE
    CNEC
     Dterm (a)Dterm (b)
    [Node B]
    [Node A]CCIS RBT
    RGRBT
    called Dterm
    VOICE
    XXXX
    NECNEC
     Dterm (a)Dterm (b)
    [Node B] [Node A]CCISSpeakerVoice
    NEC
    STN (a)
    Dterm (b)
    [Node B]
    [Node A]CCISRBT
    RBT
    RG 
    						
    							NEAX2400 IMX Feature Programming Manual
    Page 998ND-70184 (E), Issue 3
    V-7 Voice Call - CCIS
    Operating Procedure (cont’d)
    2. Station (a) switch hook flashes and receives special dial tone. Dterm (b) still does not answer.
    3. Station (a) dial the Access Code of VOICE CALL service and sends out a signal tone to D
    term (b) via the
    speaker. Dterm (b) talks with Station (a) via the speaker.
    Service Conditions
    1. Once a VOICE CALL is executed, the message “VOICE on multi-line set” is displayed on the called
    station.
    2. Call Forwarding-All Calls/-Busy Line/-Don’t Answer can be serviced by VOICE CALL.
    3. VOICE CALL will terminate at the station whose My-line equals the extension called.
    Programming
    Setting by VOICE button:
    STEP 1:AKYD - Assign data to Feature key. FKY= 14 
    STEP 2:ADSL - Assign SN=2 (Originating; RBT Connection) and FKY=14 (Voice Call; VOICE).
    This command is used for assigning the function to each soft key.
    STEP 3:ASFC - With respect to SFC of the stations that set Voice Call, cancel the restriction of SFI= 52. 
    (SFI= 52: Voice Call service)
    (SFI= 93: Voice Call Restrict) 
    Setting by SHF + Access Code (Individual Station):
    STEP 1:ASYD - System 1, Index 17, bit 0: (1) 
    SHF + ACC Code during RBT.
    STEP 2:ANPD - Assign minimum necessary number of digits for the first number of the Access Code of Voice
    Call. 
    STEP 3:ASPA - Assigns Access Code of Voice Call. 
    CI= H (Hooking), SIDA= 41, SRV= SSCA (Service Code Appendix)
    NEC
    STN (a)
    Dterm (b)
    [Node B]
    [Node A]CCISSPDT
    SPDT
    RG
    NEC
    STN (a)
    Dterm (b)
    [Node B]
    [Node A]Voice 
    						