    of 878
    							System Administration
    LOGIQ 5 Basic User Manual 16-121
    Direction 2300002-100 Rev. 2
    System Admin
    The System Admin screen has information about any options 
    implemented for the system.
     Figure 16-79. Administrative System Admin Preset Menu 
    Table 16-66: System Administration
    Preset ParameterDescription
    Product The name of the product.
    HW Number The hardware number of the product.
    SW Option Key The software option key.
    New To enter a new software option key, select New and 
    then enter the software option key.
    Delete To remove a software option key, select the key in 
    the SW Option Key list, and then select Delete.
    Options A list of the option name and status. 
    						
    							Customizing Your System
    16-122 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2 
    						
    							LOGIQ 5 Basic User Manual 17-1
    Direction 2300002-100 Rev. 2
    Chapter 17
    Probes and Biopsy
    This chapter consists of the information of each probe 
    and describes some special concerns, biopsy kits and 
    accessories as well as basic procedures for attaching a 
    bispsy guide to the different types of probes.  
    						
    							Probes and Biopsy
    17-2 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Probe Overview
    Ergonomics
    Probes have been ergonomically designed to:
    •  Handle and manipulate with ease
    •  Connect to the system with one hand
    •  Be lightweight and balanced
    •  Have rounded edges and smooth surfaces.
    Cables have been designed to:
    •  Connect to system with appropriate cable length
    •  Stand up to typical wear by cleaning and disinfectant 
    agents, contact with approved gel, etc.
    Cable handling
    Take the following precautions with probe cables:
    •  Keep free from wheels
    •  Do not bend the cable acutely
    •  Avoid crossing cables between probes. 
    						
    							Probe Overview
    LOGIQ 5 Basic User Manual 17-3
    Direction 2300002-100 Rev. 2
    Probe orientation
    Each probe is provided with an orientation marking (refer to 
    Figure 17-1). This mark is used to identify the end of the probe 
    corresponding to the side of the image having the orientation 
    mark on the display.
     Figure 17-1. Orientation Marking on Probe
    1. Orientation Mark
    Labeling
    Each probe is labeled with the following information:
    •  Sellers name and manufacturer
    • Operating frequency
    •  GE part number
    •  Probe serial number
    •  Month and year of manufacture
    •  Probe designation-provided on the probe grip and the top of 
    the connector housing, so it is easily read when mounted on 
    the system and is also automatically displayed on the 
    screen when the probe is selected.
    1 
    						
    							Probes and Biopsy
    17-4 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Labeling (continued)
     Figure 17-2. Probe Adapter Label
     Figure 17-3. Probe Handle Labels
    GEMS-Am   GEMS-E   GEMS-A
    MANUFACTURED
    e.g. SEPTEMBER 1993
    Also found on 
    Probe Connector
    E8C
    3Cb
    *GEMS-E-Am   *GEMS-A   *JAPAN    *GEMS-E 
    						
    							Probe Overview
    LOGIQ 5 Basic User Manual 17-5
    Direction 2300002-100 Rev. 2
    Labeling (continued)
     Figure 17-4. Probe Connector Labels
     Figure 17-5. Displayed Probe Information
    1.  Probe Information Location
    3Cb1
    32
    1
    2
    3
    3Cb5CM7CE8C
    GEMS-Am   GEMS-E   GEMS-A
    MANUFACTURED
    e.g. SEPTEMBER 1993Also found on 
    Probe Connector
    1 
    						
    							Probes and Biopsy
    17-6 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    LOGIQ 5 Applications
    Table 17-1: Probe Indications for Use
    Probe 
    Application
    3C3.5C5CE8C7L10L12L3S8C
    Abdomen X X X X X X X
    Small Parts X X X X X X X
    Periph. Vasc. X X X X
    Obstetrics XXXX X
    Gynecology XXXX X
    Pediatrics X X X X X
    Neonatal X X X
    Urology XXXX X X
    Surgery X
    Cardiac
    Endocavity
    Transcranial
    Biopsy XXXX XX X 
    						
    							Probe Overview
    LOGIQ 5 Basic User Manual 17-7
    Direction 2300002-100 Rev. 2
    LOGIQ 5 Applications (continued)
    Table 17-2: Probe Indications for Use (continued)
    Probe 
    Application
    P2DP6D
    Abdomen
    Small Parts
    Periph. Vasc. X
    Obstetrics
    Gynecology
    Pediatrics
    Neonatal
    Urology 
    Surgery
    Cardiac X
    Endocavity
    Transcranial
    Biopsy 
    						
    							Probes and Biopsy
    17-8 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    LOGIQ 5 Features
    Table 17-3: Probe Features
    Probe 
    Application
    3C3.5C5CE8C7L10L12L3S8C
    Coded 
    HarmonicsXX XXX X X
    B-Flow X
    Coded Contrast X
    LOGIQ ViewXXXX XXX X X
    Virtual Convex X X X
    Easy 3D XXXX XXX X X
    Advanced 3D  XXXX XXX X X
    Anatomical MXXXX XXX X X
    M Color Flow X X X
    Tru Access XXXX XXX X X
    Biopsy XXXX XXX
    Non-Imaging 
    CW 
    						