    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-51
    Direction 2300002-100 Rev. 2
    Editing Calculations (continued)
    The Measure tab for user-defined calculations is displayed. 
     Figure 7-29. Measurement & Analysis M&A tab 
    						
    							General Measurements and Calculations
    7-52 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Deleting a Folder or Measurement
    NOTE:  You can only delete user-defined folders or measurements. You 
    cannot delete default system folders or measurements.
    1.  Select the folder or measurement in the Selection menu.
    2.  In the Measurement menu section, select the X next to 
    Delete measure and study. 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-53
    Direction 2300002-100 Rev. 2
    M&A Advanced Preset
    The system allows you to specify application-specific values for 
    certain parameters. You specify the parameter values on the 
    Advanced tab of the Measurement & Analysis screen.
    1.  On the Touch Panel, select Utility.
    2.  On the Touch Panel, select Measure.
    3.  On the monitor display, select the Advanced tab. 
     Figure 7-30. M&A Advanced Preset Menu
    M&A Category: Display and select current exam category. 
    Parameter: Lists application specific parameters.
    Va l u e: Select the value for a parameter. 
    						
    							General Measurements and Calculations
    7-54 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    M&A Advanced Preset (continued)
    4.  To select an exam category, select it from the M&A category 
    list.
    The Parameters list displays parameters for the selected 
    category.
    5.  To select a value for a parameter, select it from the Value 
    list.
    •  Doppler Default Method: Aveg., Max, Min or Last
    •  Doppler Trace Cycles: 1, 2, 3, 4 or 5
    •  Heart Rate Cycle: 1, 2, 3, 4, 5, 6, 7, 8, 9 or 10 (future)
    •  Start M&A on a Freeze (B, M or D): Off, On or Caliper
    Off: Select measurement manually on Freeze.
    On: Measurement menu appears automatically on 
    Freeze.
    Caliper: Measurement menu and caliper appear 
    automatically on Freeze.
    •  RI Calc Bidirectional Flow: On or Off
    •  RI Calc Method: MD or ED
    •  Keep Result Window: On or Off
    •  Trace: Auto or Manual
    •  VOL Flow Method: TAMEAN or TAMAX 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-55
    Direction 2300002-100 Rev. 2
    Manual Calcs Presets
    The system allows you to preset the parameters for manual 
    calculations. You specify the parameter values on the Doppler 
    tab of the Measurement & Analysis screen.
    1.  On the Touch Panel, select Utility.
    2.  On the Touch Panel, select Measure.
    3.  On the monitor display, select the Doppler tab. 
     Figure 7-31. M&A Doppler Preset Menu
    M&A Category: Display and select current exam category.  
    						
    							General Measurements and Calculations
    7-56 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Manual Calcs Presets (continued)
    4.  To select an exam category, select it from the M&A category 
    list.
    The system displays a hierarchical view of the exam 
    category and the studies and folders in the category.
    5.  In the hierarchical view, select a study or folder.
    6.  In the Modify Calcs column, select the measurements that 
    you want to the system to show for manual calcs for the 
    selected study or folder.
    7.  To save the changes, select the Save button. 
    						
    							Mode Measurements
    LOGIQ 5 Basic User Manual 7-57
    Direction 2300002-100 Rev. 2
    Mode Measurements
    B-Mode Measurements
    Two basic measurements can be made in B-Mode.
    • Distance
    •  Circumference and Area (Ellipse or Trace Method)
    NOTE:  The following instructions assume that you first scan the 
    patient and then press Freeze.
    Distance measurement
    To make a distance measurement:
    Measure• Press Measure once; an active caliper displays
    • To position the active caliper at the start point, move the Trackball.
    Set• To fix the start point, press Set.
    The system fixes the first caliper and displays a second 
    active caliper.
    • To position the second active caliper at the end point, move the Trackball.
    A dotted line connects the measurement points.
    Set• To complete the measurement, press Set.
    The system displays the distance value in the Results 
    Window. 
    						
    							General Measurements and Calculations
    7-58 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Distance measurement (continued)
    The following hints can help you to perform distance 
    measurements: 
    HINTS•  Before you complete a measurement:
    •  To toggle between active calipers, press Measure.
    •  To erase the second caliper and the current data 
    measured and start the measurement again, press 
    Clear once.
    •  To rotate through and activate previously fixed calipers, 
    adjust Cursor Select.
    •  After you complete the measurement, to erase all data that 
    has been measured to this point, but not data entered onto 
    worksheets, press Clear. 
    						
    							Mode Measurements
    LOGIQ 5 Basic User Manual 7-59
    Direction 2300002-100 Rev. 2
    Circumference and area (ellipse) measurement
    You can use an ellipse to measure circumference and area. To 
    measure with an ellipse:
    Measure• Press Measure once; an active caliper displays.
    • To position the active caliper, move the Trackball.
    Set• To fix the start point, press Set. The system fixes the first caliper and displays 
    a second active caliper
    • To position the second caliper, move the Trackball. 
    						
    							General Measurements and Calculations
    7-60 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Circumference and area (ellipse) measurement (continued)
    • Adjust the Ellipse control; an ellipse with an initial circle shape displays.
    • To position the ellipse and to size the measured axes (move the calipers), 
    move the Trackball.
    • To increase the size, adjust the Ellipse control in a clockwise direction. To 
    decrease the size, adjust the Ellipse control in a counterclockwise direction.
    Measure• To toggle between active calipers, press Measure.
    Set• To complete the measurement, press Set. The system displays the 
    circumference and area in the Results Window.
    HINTSBefore you complete the ellipse measurement:
    •  To erase the ellipse and the current data measured, press 
    Clear once. The original caliper is displayed to restart the 
    measurement.
    •  To exit the measurement function without completing the 
    measurement, press Clear a second time. 
    						