    							Introduction
    LOGIQ 5 Basic User Manual 7-11
    Direction 2300002-100 Rev. 2
    Specifying measurement and display options (continued)
    Displaying the
    Results and
    Summary
    WindowsTypically, the Results Window and Summary Window are shown 
    on the monitor display. If you want, you can remove them from 
    the display. To remove them, select the Options tab, and then 
    select Display Off. To re-display them, select Display Off.
    NOTE:  Display Off removes both the Results Window and Summary 
    Window from the monitor display.
    Selecting cursor
    sizeTo select the cursor size, select the Options tab, and then select 
    Cursor Size. The system displays the following choices:
    • 12 x 12
    •  9 x 9
    Select the size you want.
    Specifying heart
    rate cyclesWhen you measure heart rate, the system assumes a specific 
    number of cycles are measured. You can change the number of 
    cycles used in the calculation. To specify the number of heart 
    rate cycles, select the Options tab, then select Heart Rate 
    Cycle. The system displays a list of choices from 1 – 10. Select 
    the number you want.
    After you choose a number, the next time you measure heart 
    rate, the system assumes you are measuring the specified 
    number of cycles. That number is used when calculating the 
    heart rate.
    After changing patients, the system defaults to the number 
    specified in the Heart Rate Cycle parameter.  
    Moving the
    Results WindowYou may want to change where the Results Window is 
    positioned on the monitor display. To move the Results Window, 
    select the Options tab, then select Move Res Win. The system 
    displays the following choices:
    • Left Top
    • Right Top
    • Right Bottom
    • Left Bottom
    Select the position you want.  
    						
    							General Measurements and Calculations
    7-12 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    General Instructions (continued)
    The following are actions you can take while performing 
    measurements.
    Calculation formulas are available in the Advanced Reference 
    Manual.
    HINTS•  Before making measurements, to stop the acquisition of 
    image data, press Freeze.
    •  For measurements such as distance, to make fine 
    adjustments before completing the measurements, press 
    Measure to toggle between active calipers.
    •  Before completing the measurement sequence, to erase 
    the active measuring caliper and the current data 
    measured, press Clear.
    •  After the sequence is complete, to erase all data that has 
    been measured to this point, but not data entered on 
    worksheet pages, press Clear.
    •  When there are several measurements on the display, to 
    rotate through and activate previously fixed calipers, adjust 
    the Cursor Select knob. After a cursor is activated, you 
    can change the measurement. 
    NOTE: If you want to change a trace measurement, you 
    must erase it and trace again.
    •  To repeat any measurement, select that measurement 
    again from the Touch Panel. 
    						
    							Introduction
    LOGIQ 5 Basic User Manual 7-13
    Direction 2300002-100 Rev. 2
    Erasing measurements
    The following actions erase measurements from the systems 
    memory: 
    HINTS•  If you adjust the Trackball, unfreeze the image, or press 
    Clear, the system erases all completed measurements and 
    calculations on the display. Measurements and 
    calculations, however, remain on the worksheets.
    •  If you select New Patient, the system erases all 
    measurements and calculations on the display and clears 
    the worksheets.
    •  If you make a new measurement that exceeds the 
    maximum number of allowable measurements, the system 
    erases the first (oldest) measurement and adds the new 
    measurement.
    •  If the second caliper is active, to erase the second caliper 
    and activate the first caliper, press Clear. 
    						
    							General Measurements and Calculations
    7-14 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Measurement and Calculation Setup
    When you receive your LOGIQ 5 system, the studies and 
    measurements are organized for typical work flows. If you want, 
    you can change this set up. You can specify which studies are in 
    each exam category, and which measurements and calculations 
    are in each study. You can change the measurements that are 
    available on the Touch Panel. The LOGIQ 5 allows you to 
    quickly and easily set up your system so that you can work most 
    efficiently. 
    This section describes how to:
    •  Change a study to include different measurements
    •  Add a new study or measurement
    •  Remove a study from an exam category
    • Change measurement parameters
    •  Create a measurement formula to correctly handle unit 
    conversions
    • Edit user-defined calculations
    •  Define application-specific measurement parameters
    •  Specify the default manual calc measurements for a 
    selected study or folder 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-15
    Direction 2300002-100 Rev. 2
    Starting Study and Measurement SetUp 
    You make changes to studies and measurements in the 
    Measurement & Analysis screen. To open the screen:
    1.  On the Touch Panel, select Utility.
    2.  On the Touch Panel, select Measure.
    3.  On the monitor display, select the M & A tab.
    The system displays the Measurement & Analysis screen 
    on the monitor display.
     Figure 7-4. Measurement & Analysis screen
    1. Selection menu: select exam 
    category, study, or measurement.3. Folder or measurement: define 
    studies and measurements. This 
    section changes between Folder and 
    Measurement, depending on what 
    you select in the Selection menu. 2. Measurement menu: add and delete 
    studies (folders) and measurements; 
    select mode.
    1
    2
    3 
    						
    							General Measurements and Calculations
    7-16 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Selecting an exam category
    When you open the Measurement & Analysis screen, it displays 
    the exam category that was last used on the system. To select 
    the exam category you want to work with:
    1. Move the Trackball to highlight the exam category at the 
    top of the Selection menu. 
    2. Press Set.
    The system displays a list of exam categories.
    3. Move the Trackball to highlight the exam category you 
    want.
    4. Press Set.
    The Selection menu lists studies and measurements for the 
    selected exam category.
     Figure 7-5. Select Exam Category 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-17
    Direction 2300002-100 Rev. 2
    Selecting the measurement mode
    In the Measurement menu section of the Measurement & 
    Analysis screen, select one of the following:
    • 2D (B-Mode)
    • MM (M-Mode)
    •  Dop (Doppler Mode)
    The Selection menu lists studies and measurements for the 
    selected mode.
     Figure 7-6. Select Mode 
    						
    							General Measurements and Calculations
    7-18 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Selecting a study or measurement
    To work with a folder or measurement, you must first select it in 
    the Selection menu. The Selection menu lists the studies and 
    measurements for an exam category. The studies and 
    measurements are organized in a hierarchy, in the same order 
    that they are organized on the Touch Panel. The illustration 
    below shows the highest level of the Obstetrics exam category, 
    with the OB studies listed.
     Figure 7-7. Selection Menu: Exam Studies 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-19
    Direction 2300002-100 Rev. 2
    Selecting a study or measurement (continued)
    After you select a study, the Selection menu shows all folders 
    and measurements in the study. The Folder section of the 
    Measurement & Analysis screen changes, and lists the 
    measurements. The Selection menu shows all measurements 
    for the OB-1 exam category. 
     Figure 7-8. Selection Menu: OB-1 Exam Category 
    						
    							General Measurements and Calculations
    7-20 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Selecting a study or measurement (continued)
    The illustration below shows the Selection menu after the BPD 
    measurement is selected. The Measurement section is now 
    displayed, with information about the BPD measurement. 
     Figure 7-9. Selection Menu: BPD Measurement 
    						
    All GE manuals Comments (1)