Cardiology Measurements LOGIQ 5 Basic User Manual 10-21 Direction 2300002-100 Rev. 2 Pulmonic Valve The following are cardiac B-Mode Pulmonic Valve measurements: One distance measurement• Pulmonic Valve Annulus Diameter (PV Ann Diam) • Pulmonic Diameter (Pulmonic Diam) Making a one distance measurement1. Select the measurement; an active caliper displays. 2. To position the active caliper at the start point, move the Trackball. 3. To fix the start point, press Set. The system fixes the first caliper and displays a second active caliper. 4. To position the second active caliper at the end point, move the Trackball. A dotted line connects the measurement points. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window.
Cardiology 10-22 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Right Atrium The following are cardiac B-Mode Right Atrium measurements: One distance measurement• Right Atrium Diameter, Length (RA Major) • Right Atrium Diameter, Length (RA Minor) Making a one distance measurement1. Select the measurement; an active caliper displays. 2. To position the active caliper at the start point, move the Trackball. 3. To fix the start point, press Set. The system fixes the first caliper and displays a second active caliper. 4. To position the second active caliper at the end point, move the Trackball. A dotted line connects the measurement points. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window.
Cardiology Measurements LOGIQ 5 Basic User Manual 10-23 Direction 2300002-100 Rev. 2 Right Atrium (continued) One trace measurements• Right Atrium Area (RA Area) • Right Atrium Volume, SIngle Plane, Method of Disk (RAAd) • Right Atrium Volume, Systolic, SIngle Plane, Method of Disk (RAAs) Making a trace measurement1. Select the measurement; an active caliper displays. 2. To position the caliper at the start point, move the Trackball. 3. To fix the trace start point, press Set. The system displays a vertical dotted line. 4. To trace the measurement area, move the Trackball. A line shows the traced area. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window.
Cardiology 10-24 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Right Ventricle The following are cardiac B-Mode Right Ventricle measurements: One trace measurement• Left Pulmonary Artery Area (LPA Area) • Right Pulmonary Artery Area (RPA Area) Making a trace measurement1. Select the measurement; an active caliper displays. 2. To position the caliper at the start point, move the Trackball. 3. To fix the trace start point, press Set. The system displays a vertical dotted line. 4. To trace the measurement area, move the Trackball. A line shows the traced area. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window.
Cardiology Measurements LOGIQ 5 Basic User Manual 10-25 Direction 2300002-100 Rev. 2 Right Ventricle (continued) One distance measurements• Right Ventricle Internal Diameter • Diastolic (RVIDd) • Systolic (RVIDs) • Right Ventricle Wall Thickness • Diastolic (RVAWd) • Systolic (RVAWs) • Right Ventricle Outflow Tract Diameter (RVOT Diam) • Left Pulmonary Artery (LPA) • Main Pulmonary Artery (MPA) • Right Pulmonary Artery (RPA) Making a one distance measurement1. Select the measurement; an active caliper displays. 2. To position the active caliper at the start point, move the Trackball. 3. To fix the start point, press Set. The system fixes the first caliper and displays a second active caliper. 4. To position the second active caliper at the end point, move the Trackball. A dotted line connects the measurement points. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window.
Cardiology 10-26 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 System The following are cardiac B-Mode System measurements: One distance measurements• Interventricular Septum Thickness • Diastolic (IVSd) • Systolic (IVSs) • Inferior Vena Cava (IVC) • Main Pulmonary Artery Diameter (MPA) • Systemic Vein Diameter (Systemic Diam) • Patent Ductus Arterosis Diameter (PDA Diam) • Patent Foramen Ovale Diameter (PFO Diam) • Ventricular Septal Defect Diameter (VSD Diam) Making a one distance measurement1. Select the measurement; an active caliper displays. 2. To position the active caliper at the start point, move the Trackball. 3. To fix the start point, press Set. The system fixes the first caliper and displays a second active caliper. 4. To position the second active caliper at the end point, move the Trackball. A dotted line connects the measurement points. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window. Body surface area and stroke volume measurements• Interventricular Septum (IVS) Fractional Shortening (IVSs) The system calculates body surface area from the patient’s height and weight.
Cardiology Measurements LOGIQ 5 Basic User Manual 10-27 Direction 2300002-100 Rev. 2 Tricuspid Valve The following are cardiac B-Mode Tricuspid Valve measurements: One distance measurements• Tricuspid Valve Annulus Diameter (TV Ann Diam) • Tricuspid Valve Area (TV Area) Making a one distance measurement1. Select the measurement; an active caliper displays. 2. To position the active caliper at the start point, move the Trackball. 3. To fix the start point, press Set. The system fixes the first caliper and displays a second active caliper. 4. To position the second active caliper at the end point, move the Trackball. A dotted line connects the measurement points. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window.
Cardiology 10-28 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 M-Mode Measurements Aorta The following are cardiac M-Mode aorta measurements: One distance measurement• Aortic Root Diameter (Ao Root Diam) Making a one distance measurement1. Select the measurement; an active caliper displays. 2. To position the active caliper at the start point, move the Trackball. 3. To fix the start point, press Set. The system fixes the first caliper and displays a second active caliper. 4. To position the second active caliper at the end point, move the Trackball. A dotted line connects the measurement points. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window.
Cardiology Measurements LOGIQ 5 Basic User Manual 10-29 Direction 2300002-100 Rev. 2 Aortic Valve The following are cardiac M-Mode aortic valve measurements: One distance measurements• Aortic Valve Cusp Separation (AV C u s p) Making a one distance measurement1. Select the measurement; an active caliper displays. 2. To position the active caliper at the start point, move the Trackball. 3. To fix the start point, press Set. The system fixes the first caliper and displays a second active caliper. 4. To position the second active caliper at the end point, move the Trackball. A dotted line connects the measurement points. 5. To complete the measurement, press Set. The system displays the measurement in the Results Window.
Cardiology 10-30 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Left Atrium The following are cardiac M-Mode Left Atrium measurements: Two distance measurement (ratio)• Left Atrium Diameter to AoRoot Diameter Ratio (LA/Ao) Making two distance measurements1. Select LA/Ao; an active caliper displays. 2. Make the first distance measurement: a. To position the active caliper at the start point, move the Trackball. b. To fix the start point, press Set. The system fixes the first caliper and displays a second active caliper. c. To position the second active caliper at the end point, move the Trackball. A dotted line connects the measurement points. d. To complete the measurement, press Set. The system displays the distance value in the Results Window. After the first measurement, the system displays an active caliper. 3. To make the second distance measurement, repeat steps a–d above. The system displays the measurements and ratio in the Results Window.