Have a look at the manual GE Logiq P5 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
System Presets LOGIQ 5 Basic User Manual 16-11 Direction 2300002-100 Rev. 2 Keyboard Setup Procedure for Russian and Greek (continued) 3. Press Add. The Add Input Locale menu appears. On the pull-down menu, move the Trackball until you see Russian or Greek. Press Set to select. Press Ok. You are returned to the Input Locales menu. Figure 16-5. Adding Russian Input Locale
Customizing Your System 16-12 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Keyboard Setup Procedure for Russian and Greek (continued) 4. Specify Russian or Greek as the default language by pressing Set as Default. Figure 16-6. Set Russian to be the Default
System Presets LOGIQ 5 Basic User Manual 16-13 Direction 2300002-100 Rev. 2 Keyboard Setup Procedure for Russian and Greek (continued) 5. At the bottom of the Input Locales menu, you now need to specify the keys you will press to toggle between the English and the Russian or Greek keyboards. Press Change Key Sequence. The Change Key Sequence pop-up menu appears. Make sure the Enable Key Sequence box has a check mark in it. Select CTRL + SHIFT and say OK. You are returned to the Input Locales menu. Figure 16-7. Set Keyboard Toggle Keystroke 6. Apply the changes by pressing Apply. Press OK.
Customizing Your System 16-14 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Keyboard Setup Procedure for Russian and Greek (continued) 7. Press the General tab. Set Your Locale (location) to Russian or Greek. Figure 16-8. Set the Locale
System Presets LOGIQ 5 Basic User Manual 16-15 Direction 2300002-100 Rev. 2 Keyboard Setup Procedure for Russian and Greek (continued) 8. Press Set default at the bottom of the menu to Select System Locale. Press Ok. Then Apply the changes. Figure 16-9. Selecting the System Locale 9. A general system pop-up message appears. Answer Yes. Figure 16-10. General Windows Pop-Up Message
Customizing Your System 16-16 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Keyboard Setup Procedure for Russian and Greek (continued) 10. Restart the system when prompted: The system screens, menus, and Touch Panel display is now in Russian or Greek. Figure 16-11. Restart System Prompt To set up Russian (or Greek), follow the procedure below EACH TIME software is reloaded on your system. NOTE: To have the settings take effect, you MUST turn off the system and turn it back on. To toggle between the Russian and English keyboards, press the CTRL + SHIFT keys at the same time.
System Presets LOGIQ 5 Basic User Manual 16-17 Direction 2300002-100 Rev. 2 Keyboard Setup Procedure for Russian and Greek (continued) Here is an example of the Russian keyboard: Figure 16-12. Russian Keyboard Here is an example of the Greek keyboard: Figure 16-13. Greek Keyboard
Customizing Your System 16-18 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 System/System Imaging Preset Menu The System/System Imaging screen allows you to specify parameters for cine loop storage and display, patient information, key usage, and image control and display. Figure 16-14. System/System Imaging Preset Menu Table 16-6: Cine Loop Store Preset ParameterDescription Time span (no ECG) [s]Select the number of seconds of CINE Loop storage (no ECG). The default is 3 seconds (approximately 77 B/W frames, 97 Color Frames). Preview loop before storeWhen selected, allows you to review cine loops before storage.
System Presets LOGIQ 5 Basic User Manual 16-19 Direction 2300002-100 Rev. 2 System/System Imaging Preset Menu (continued) Table 16-7: Cardiac Preset ParameterDescription Time before heart cycle [ms]Sets the total storage time span of the cine loop in ECG mode. Time after heart cycle [ms]Sets the total storage time span of the cine loop in ECG mode. Time span of systole [ms]The default systolic time to enable synchronization of cine loops. Table 16-8: Biopsy Guides Preset ParameterDescription Show Center Line Displays center biopsy guideline. Show Outer Lines Displays outer biopsy guidelines. Enable 0.5cm markersActivates biopsy depth markers every 0.5cm. Table 16-9: Image Control and Display Preset ParameterDescription Horizontal Scale Select to display width markers. TGC Display Select to display TGC curve. PW Velocity Units in cm/sSelect to change scale on timeline from centimeters per second to meters per second. Split screen full height display of linear imagesWhen selected, while in split screen and using a linear probe, the system clips the sides of images so that the image can fill the available display. Auto Invert on Linear SteerWhen selected, for auto calcs, automatically inverts the timeline if needed when using ASO. Auto Invert on ASO Automatically inverts the spectrum with ASO. Audio Volume Adjusts the Doppler audio volume. Auto Freeze (15 minutes)Automatically freezes the system after 15 minutes of inactivity. Image Parameter Size (reboot required)Choices=small, medium, and large. Must reboot the system. Show Clipboard Select to show clipboard.
Customizing Your System 16-20 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 System/System Measure Preset Menu The System/System Measure screen allows you to specify measurement parameters such as the type of default OB measurements and calculations. You can also define cursor and Results Window default functionality. Figure 16-15. System/System Measure Preset Menu