    							OB-Multigestational
    LOGIQ 5 Basic User Manual 9-75
    Direction 2300002-100 Rev. 2
    Using other OB studies (continued)
     Figure 9-19. OB Touch Panel: ASUM studies
    NOTE:  ASUM studies include the following measurements:
    •  ASUM: AC, BPD, and CRL
    •  ASUM 2001: AC, BPD, CRL, FL, HC, HL, and OFD 
    						
    							OB/GYN
    9-76 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Multiple Fetus
    LOGIQ 5 allows you to measure and report multiple fetus 
    development. The system can report a maximum of four 
    fetuses.
    To enter the number of fetuses 
    If more than one fetus is imaged during the exam, enter the 
    number of fetuses in the Patient Data Entry Menu.
     Figure 9-20. Fetus Number
    When you start an OB exam, the system automatically fills in the 
    Fetus # field with 1. To change the number:
    1.  Move the cursor to the fetus number and press Set twice.
    The number is highlighted.
    2.  Type the correct number and press Set.
    The system displays a message to confirm that you want to 
    change the fetus number.
    3. Select Yes. 
    						
    							OB-Multigestational
    LOGIQ 5 Basic User Manual 9-77
    Direction 2300002-100 Rev. 2
    To identify each fetus
    For measurements, calculations, and worksheet displays, the 
    system labels each fetus A, B, C, or D. Each fetus is identified 
    by a letter and the total number of fetuses. For example, fetus  
    A/3 is fetus A from a total of 3.
    When scanning, you can enter information about the fetus 
    position and placenta location. You can enter the information in 
    the Patient Data section of the worksheets and the graphs. You 
    can type up to 23 characters in the FetusPos and PLAC fields. 
     Figure 9-21. Patient Data section of the OB Worksheet
    To select a fetus
    During measurements and calculations, to change between 
    fetuses, do one of the following: 
    • Adjust the Fetus knob.
    • Move the Trackball to the Summary Window and select the 
    fetus.
     Figure 9-22. Summary Window: Multiple fetus
     You can change between fetuses at any time during the exam.
    NOTE:  After you change to the next fetus, any measurements you 
    make are recorded and reported to that fetus. If you have any 
    active measurement or calculation that is not completed when 
    you change the fetus, the system cancels the measurement or 
    calculation. 
    						
    							OB/GYN
    9-78 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    To view multiple fetuses data on graphs
    You can view multiple gestation data on fetal growth curve 
    graphs. After you have made measurements for each fetus, 
    select Graph Display. 
    •  To view the graph for each fetus, do one of the following:
    • Adjust the Fetus knob.
    •  In the Patient Data section, move the Trackball to 
    highlight the FetusNo field. In the list of fetuses, move 
    the Trackball to select the fetus you want, and press 
    Set.
    •  To display data for multiple fetuses on the same graph, 
    select Fetus Compare.
     Figure 9-23. Fetal Growth Curve Graph: Fetus Compare
    The legend at the bottom of the graph shows the symbols and 
    colors that represent each fetus. 
    						
    							OB-Multigestational
    LOGIQ 5 Basic User Manual 9-79
    Direction 2300002-100 Rev. 2
    To compare multiple fetus data on a worksheet
    With multiple fetuses, you can list and compare measurements 
    of the fetuses on the worksheet. 
    Select Worksheet Display, then select Fetus Compare. 
     Figure 9-24. OB Worksheet Display Touch Panel 
    						
    							OB/GYN
    9-80 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    To compare multiple fetus data on a worksheet (continued)
    When you select Fetus Compare, the system lists the 
    measurement results for each fetus on the Worksheet.
     Figure 9-25. Worksheet Display with Fetus Compare 
    						
    							OB-Multigestational
    LOGIQ 5 Basic User Manual 9-81
    Direction 2300002-100 Rev. 2
    To Show Fetal Trending for Multiple Fetuses 
    When you have data for more than one exam, you can show 
    fetal trending and compare fetuses on one graph. 
    To view fetal trending for multiple fetuses: 
    1. Select Graph Display.
    2. Select Fetus Compare. 
    3. Select Plot Both.
    NOTE:  You can only view fetal trending for multiple fetuses in single 
    graph display.
     Figure 9-26. Multigestation Fetal Growth Curve Graph
    The symbol key for fetal trending and multiple fetuses is shown 
    at the bottom of the graph. 
    						
    							OB/GYN
    9-82 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    OB Table Editor
    You can add user programmable OB tables to the system.
    OB Table Settings Menu
    You add OB Tables in the Measurement & Analysis menu. To 
    open the menu:
    1.  On the Touch Panel, select Utility, then select M&A.
    2.  Check the Exam Category on the far left of the monitor 
    screen.  Make sure that Obstetrics is selected.
    If it is not selected, select Obstetrics and continue selecting 
    the folders until the appropriate area is selected as to where 
    this new OB Table will be entered.  For example, select 
    Obstetrics, then select OB-2/3.  If there are further folders 
    within OB-2/3, select that appropriate folder. 
    						
    							OB Table Editor
    LOGIQ 5 Basic User Manual 9-83
    Direction 2300002-100 Rev. 2
    OB Table Settings Menu (continued)
    3.  On the monitor display, select the OB Table tab.
    The system displays the OB Table settings menu. 
     Figure 9-27. OB Table settings 
    						
    							OB/GYN
    9-84 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    OB Table Settings Menu (continued)
    4.  The OB Table settings menu lists OB Table parameters. 
    Specify the following parameter values as appropriate:
    • Study: Shows the study to which this measurement 
    table belongs.
    • New/Edit: To create a new OB table, select New Table. 
    To edit an existing user-programmable OB table, select 
    Edit Table.
    NOTE:  You cannot edit the system’s OB Tables.
    • O B  Ta b l e  Te m p l a t e: To create a new OB table, select 
    the Template (1 - 7) which you want to use as the basis 
    of the user programmable OB Table. See ‘OB Table 
    Templates’ for more information.
    To edit an existing user OB table, select the desired OB 
    table to edit.
    • Tool Type: Select the type of measurement: Distance or 
    Circumference.
    • Measure Name: Type the name of measurement that 
    will display on the Touch Panel.
    • Author Name: Type the author’s name.
    • Ta b l e  Ty p e: If necessary, select the Table Type: Fetal 
    Age or Fetal Growth.
    • Measure Type: Select a measurement type that can be 
    used to calculate EFW, for example BPD. 
    NOTE:  Measure Type is used only when calculating EFW.
    NOTE:  The following items are display only: Table Format, Table 
    Unit, SD/GP Range, and Graph Range. The system 
    determines these values automatically, based on the type of 
    OB table you are creating.
    5.  After specifying all parameter values, move the Trackball to 
    Edit Table and press Set.
    The system displays the Edit Menu.
    NOTE:  If any of the OB table parameters are not correct, the Edit 
    Menu is not displayed. 
    						