    LOGIQ 5 Basic User Manual 15-31
    Direction 2300002-100 Rev. 2
    Other Printing Options
    Connecting to a Standard Computer Printer
    You can now connect a standard computer printer, via the USB 
    connection (Service). We currently support the HP970 CXI or 
    HP990 CXI standard computer printers. 
    NOTE:  You can connect a different printer if you have the driver for it on 
    a CD-ROM (*.inf file).
    1.  Connect the printer to the USB port at the back of the 
    system (in the Service port). 
    2.  Install the driver, if necessary. Please refer to the Basic 
    Service Manual for more information. 
    3.  Set the printer as the default printer. 
    						
    							Recording Images
    15-32 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Connecting to a Standard Computer Printer (continued)
    4.  Assign one of the print keys (P1-P4) to the standard printer 
    via Utility --> Connectivity --> Buttons --> Select 
    Destinations and select (Standard Print @ My Computer). 
    This allows you to print the screen by pressing the print 
    screen key. The system automatically determines the 
    portion of the screen to print based upon what is currently 
    displayed. 
     Figure 15-30. Print Button Example 
    						
    							Other Printing Options
    LOGIQ 5 Basic User Manual 15-33
    Direction 2300002-100 Rev. 2
    Connecting to a Standard Computer Printer (continued)
    5.  Bring up the worksheet you want to print on the monitor. Any 
    page displayed on the monitor can be printed.
    6.  Press the P1-4 key that you assigned in Step 2 above.
    NOTE:  You can also set a preset to override the automatic area print 
    and force the entire screen to print by pressing Utility -> System 
    --> Setup and setting the Standard Printer to Print Full Screen.
    NOTE:  Worksheets and Graphs are printed in reverse video for easier 
    readibility. You can also set a preset to override this presentation 
    by pressing Utility --> System --> Setup and setting the Standard 
    Printer to Allow Reverse Video. 
    External Printers
    You can also connect an external printer through the External 
    Printer 1/2 remote expose connections on the back of the 
    system. 
    To use a remote printer, assign a print key (P1-P4) via Utility --> 
    Connectivity --> Buttons --> Select Destinations and select 
    External Printer 1/2 @ My Computer. 
    						
    							Recording Images
    15-34 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Transferring Patient Data to a PC
    Transferring OB/GYN Patient Data to a PC
    The LOGIQ 5 now supports the transfer of OB, GYN and 
    Vascular patient data to a PC. 
    NOTE:  The LOGIQ 5 currently supports Viewpoint patient data 
    communications software for the PC. 
    Connecting the LOGIQ 5 to the PC
    You need to connect a RS232C Converter and RS232C Cross 
    Cable to the USB port to connect a serial peripheral device to 
    the system. 
     Figure 15-31. RS232C to USB Connection
    CAUTIONBe sure to connect the converter and cable BEFORE booting 
    the system. If not, the LOGIQ 5 does not recognize the 
    peripheral device. 
    1. System 3. USB-to-RS232C converter
    2.  Peripheral device 4.  RS232C Cross Cable (female 9 pin-
    to-female 9-pin)
    USB RS232C12
    34 
    						
    							Transferring Patient Data to a PC
    LOGIQ 5 Basic User Manual 15-35
    Direction 2300002-100 Rev. 2
    Transferring Patient Data
    After you perform a scan, you can send the patient and 
    measurement data to a PC that accepts patient data. 
    1.  Ensure that the peripheral device is on. 
    2.  For the current patient, on the Worksheet screen, select 
    Meas. Transf.
     Figure 15-32. Transferring OB Worksheet Data to a PC 
    						
    							Recording Images
    15-36 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Transferring Patient Data (continued)
    3.  The system transfers the data. A beep on the peripheral 
    device indicates a successful transfer.  If there is a problem 
    with the connection or transfer, the system displays an error 
    message.
    NOTE:  If you currently do a heart rate measurement without specifying 
    a vessel, as in the case of a fetal heart, the measurement IS 
    NOT automatically transferred to the PC. You need to enter this 
    measurement manually on the PC. 
    NOTE:  Deleted measurements from the worksheet are still sent to the 
    off-line reporting PC. 
    						
    							VCR
    LOGIQ 5 Basic User Manual 15-37
    Direction 2300002-100 Rev. 2
    VCR
    Setting up the VCR
    To set up the VCR, 
    1. Select the Utility tab on the Touch Panel. 
    2. Select System on the Touch Panel. 
     Figure 15-33. Utility Touch Panel 
    						
    							Recording Images
    15-38 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Setting up the VCR (continued)
    3. Press Peripherals. 
     Figure 15-34. VCR Setup Utility Page
    4.  Trackball to the VCR pulldown menu, place the pointer on 
    the down arrow and press Set, then move the Trackball to 
    select the appropriate VCR. 
    5. Press Save, then press Exit. 
    6.  Turn off the LOGIQ 5, then turn it back on. 
    CAUTIONBe sure to connect the converter and cable before booting up 
    the system.  If not, the LOGIQ 5 does not recognize the 
    peripheral device. 
    						
    							VCR
    LOGIQ 5 Basic User Manual 15-39
    Direction 2300002-100 Rev. 2
    Using the VCR
    To use the VCR, press VCR on the Control Panel. The following 
    Touch Panel appears: 
     Figure 15-35. VCR Touch Panel
    Table 15-2: VCR Functions and Appropriate Steps
    VCR FunctionHow to Do
    To record an image1.  Insert a tape into VCR. 
    2. Press Record. 
    3.  Press to activate and control the microphone. 
    To pause recording Press Pause. 
    To begin recording again Press Record again. 
    To stop recording Press Stop/Eject. 
    To rewind the VCR tape Press Rewind. 
    To playback the tape Press Play. 
    To adjust playback speed Move the Trackball to the left/right to decrease/increase playback speed. 
    To move through the 
    playback frame by frameAdjust the Frame by Frame dial right/left. 
    To pause playback Press Pause. 
    To begin playback again Press Play. 
    To turn the microphone on/off Press MIC ON/OFF.  
    						
    							Recording Images
    15-40 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2 NOTE:  The VCR counter is displayed in two places: in the video area 
    and outside the video area. The playback counter is in the video 
    area and the current counter is outside the video area. 
    Returning to Scanning
    To return to scanning, select Video Source on the Touch Panel. 
    To adjust playback audio 
    volumeAdjust Volume left/right to lower/increase audio playback volume. 
    To fast forward the tape Press Forward. 
    To search for a recorded 
    sequenceExams are marked so that you can search VCR tapes exam by exam. 
    Press Index Search Forward/Reverse to move forward through the tape 
    exam by exam. 
    To adjust search speed Adjust Search Speed left/right to lower/increase search speed. 
    To search to the end of the 
    last examPress Search end of last exam. 
    To reset the counter Press Counter Reset. 
    To eject the VCR tape.  Press Stop/Eject twice. 
    Table 15-2: VCR Functions and Appropriate Steps
    VCR FunctionHow to Do 
    						