GE Logiq P5 User Manual
Have a look at the manual GE Logiq P5 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
OB Graphs LOGIQ 5 Basic User Manual 9-65 Direction 2300002-100 Rev. 2 Fetal Growth Curve Graph (continued) To select the measurementTo select which measurement you want to display on the Fetal Growth Curve Graph, do one of the following: • To select a specific measurement: a. On the graph display, move the Trackball to the Measurement Type field and press Set. The system displays a list of measurements. b. Move the Trackball to select the desired measurement and press Set. The system displays the Fetal Growth Curve Graph for the selected measurement. • To scroll through all Fetal Growth Curve Graphs, adjust the Graph Change knob. To select the age to useTo plot the fetus age, the system allows you to use the gestational age (GA) from the LMP, or to use the composite ultrasound age (CUA). To select, adjust the Select GA knob. The information in the left column changes between CUA and GA(EDD), and the data may change.
OB/GYN 9-66 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Fetal Growth Curve Graph (continued) To view a single or four graphsYou can view either a single Fetal Growth Curve Graph or you can view four graphs at the same time. To select each view, press Single or Quad. Figure 9-13. Fetal Growth Curve Graph: Quad View The measurement values are displayed at the bottom of the graph.
OB Graphs LOGIQ 5 Basic User Manual 9-67 Direction 2300002-100 Rev. 2 Fetal Growth Curve Graph (continued) To change measurements in quad viewWhen you view four graphs simultaneously, you can select which four you want to see. To change each graph in quad view: 1. On the graph display, use the Trackball to move the cursor to the small box that is upper left of each graph, then press Set. The system displays a list of measurements. 2. Move the Trackball to select the desired measurement and press Set. The system displays the Fetal Growth Curve Graph for the selected measurement. To scroll through all Fetal Growth Curve Graphs, adjust the Graph Change knob. The order of a quad graph view can be saved by selecting Save.
OB/GYN 9-68 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Fetal Trending When you have ultrasound data for more than one exam for a patient, you can use the data to look at fetal trending on the Fetal Growth Curve Graphs. 1. Select Graph Display and select the desired Fetal Growth Curve Graph. 2. Select Plot Both. The system automatically finds the data from previous ultrasound exams, and displays it on the graph with the present data. Figure 9-14. Fetal Trending on Fetal Growth Curve Graph: FL The legend at the bottom of the graph shows the symbols and colors that indicate Past and Present data.
OB Graphs LOGIQ 5 Basic User Manual 9-69 Direction 2300002-100 Rev. 2 Fetal Trending (continued) To manually enter past exam dataIf you have data from a previous ultrasound exam that you want to use for fetal trending, but it is not in the system, you can manually enter the data. 1. After you have registered the patient for this exam, on the Patient Data Entry screen, in the Exam Information (Obstetrics) section, select Past Exam. The system displays the Input Past Exam screen. See Figure 9-15. 2. Enter the data from previous exams. 3. To enter data on page 2, select Next. 4. After you enter the previous exam data, select Exit to Save. The system saves the previous exam data. When you view the Fetal Growth Curve Graphs, select Plot Both to view fetal trending. The system automatically uses the data you entered. Figure 9-15. Input Past Exam screen, page 1
OB/GYN 9-70 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Fetal Trending (continued) Figure 9-16. Input Past Exam screen, page 2
OB Graphs LOGIQ 5 Basic User Manual 9-71 Direction 2300002-100 Rev. 2 To edit patient data When you are working with graphs, you can change or enter the following patient data. • GA(LMP) – this field is computed using the LMP date on the Patient Data Entry screen. To change this field: NOTE: You can only change this field on the Fetal Growth Curve Graph in single view. a. Move the Trackball to the field, which is left of the graph. To select the field, press Set. The system displays a window with the GA weeks and days. b. To select each field, move the Trackball to the field and press Set. c. Type the correct weeks or days. d. Select OK. The system makes the following changes: • GA (LMP) is now GA (GA) and shows the age you entered. • In the Patient Data section, the GA changes. • In the Patient Data section, The EDD (LMP) changes to EDD(GA) and shows an updated date, using the GA you entered. The LMP is erased. • FetusPos – type information about the fetus position. • PLAC – type information about the placenta. To return from a graph to the scan display After viewing graphs, to return to the scan display, do one of the following: • On the graph display, select Exit. • On the Touch Panel, select Graph Display.
OB/GYN 9-72 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Fetal Growth Bar Graph The fetal growth bar graph shows current exam measurements and the normal growth range based on the gestational age. It shows all measurements on one graph. To view the Fetal Growth Bar Graph: 1. Press Measure. 2. Select Graph. 3. Select Bar. Figure 9-17. Fetal Growth Bar Graph
OB Graphs LOGIQ 5 Basic User Manual 9-73 Direction 2300002-100 Rev. 2 Fetal Growth Bar Graph (continued) • The horizontal axis shows the gestational weeks. • The red vertical line shows the gestational age using the patient data. • The blue dotted vertical line shows the ultrasound age using the current measurements. • The yellow x shows the ultrasound age for each measurement. • The green rectangle shows the normal age range for the measurement. You cannot do fetal trending or view multiple gestation data on the bar graph.
OB/GYN 9-74 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 OB-Multigestational Using other OB studies The LOGIQ 5 system includes measurements for the following studies: USA, Europe, Tokyo, Osaka, and ASUM. The following figures show the OB Touch Panel displays for the Tokyo and Osaka studies and for the ASUM studies. For information about how to change studies, refer to “Measurement and Analysis (M&A) System Presets” on page 16-10. Figure 9-18. OB Touch Panel: Tokyo and Osaka studies NOTE: Tokyo and Osaka studies have a folder for JSUM measurements. JSUM measurements include AC, BPD, CRL, and FL.