    							OB Graphs
    LOGIQ 5 Basic User Manual 9-65
    Direction 2300002-100 Rev. 2
    Fetal Growth Curve Graph (continued)
    To select the
    measurementTo select which measurement you want to display on the Fetal 
    Growth Curve Graph, do one of the following:
    •  To select a specific measurement:
    a.  On the graph display, move the Trackball to the 
    Measurement Type field and press Set. 
    The system displays a list of measurements.
    b. Move the Trackball to select the desired measurement 
    and press Set.
    The system displays the Fetal Growth Curve Graph for 
    the selected measurement.
    •  To scroll through all Fetal Growth Curve Graphs, adjust the 
    Graph Change knob.
    To select the age
    to useTo plot the fetus age, the system allows you to use the 
    gestational age (GA) from the LMP, or to use the composite 
    ultrasound age (CUA). To select, adjust the Select GA knob. 
    The information in the left column changes between CUA and 
    GA(EDD), and the data may change.  
    						
    							OB/GYN
    9-66 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Fetal Growth Curve Graph (continued)
    To view a single or
    four graphsYou can view either a single Fetal Growth Curve Graph or you 
    can view four graphs at the same time. To select each view, 
    press Single or Quad. 
     Figure 9-13. Fetal Growth Curve Graph: Quad View
    The measurement values are displayed at the bottom of the 
    graph.   
    						
    							OB Graphs
    LOGIQ 5 Basic User Manual 9-67
    Direction 2300002-100 Rev. 2
    Fetal Growth Curve Graph (continued)
    To change
    measurements in
    quad viewWhen you view four graphs simultaneously, you can select 
    which four you want to see. To change each graph in quad view:
    1.  On the graph display, use the Trackball to move the cursor 
    to the small box that is upper left of each graph, then press 
    Set.
    The system displays a list of measurements.
    2. Move the Trackball to select the desired measurement and 
    press Set.
    The system displays the Fetal Growth Curve Graph for the 
    selected measurement.
    To scroll through all Fetal Growth Curve Graphs, adjust the 
    Graph Change knob. 
    The order of a quad graph view can be saved by selecting Save.  
    						
    							OB/GYN
    9-68 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Fetal Trending 
    When you have ultrasound data for more than one exam for a 
    patient, you can use the data to look at fetal trending on the 
    Fetal Growth Curve Graphs.
    1. Select Graph Display and select the desired Fetal Growth 
    Curve Graph.
    2. Select Plot Both. 
    The system automatically finds the data from previous 
    ultrasound exams, and displays it on the graph with the 
    present data.
     Figure 9-14. Fetal Trending on Fetal Growth Curve Graph: FL
    The legend at the bottom of the graph shows the symbols and 
    colors that indicate Past and Present data. 
    						
    							OB Graphs
    LOGIQ 5 Basic User Manual 9-69
    Direction 2300002-100 Rev. 2
    Fetal Trending (continued)
    To manually enter
    past exam dataIf you have data from a previous ultrasound exam that you want 
    to use for fetal trending, but it is not in the system, you can 
    manually enter the data.
    1.  After you have registered the patient for this exam, on the 
    Patient Data Entry screen, in the Exam Information 
    (Obstetrics) section, select Past Exam.
    The system displays the Input Past Exam screen. See 
    Figure 9-15.
    2.  Enter the data from previous exams.
    3.  To enter data on page 2, select Next.
    4.  After you enter the previous exam data, select Exit to Save.
    The system saves the previous exam data. When you view 
    the Fetal Growth Curve Graphs, select Plot Both to view 
    fetal trending. The system automatically uses the data you 
    entered.
     Figure 9-15. Input Past Exam screen, page 1 
    						
    							OB/GYN
    9-70 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Fetal Trending (continued)
     Figure 9-16. Input Past Exam screen, page 2 
    						
    							OB Graphs
    LOGIQ 5 Basic User Manual 9-71
    Direction 2300002-100 Rev. 2
    To edit patient data
    When you are working with graphs, you can change or enter the 
    following patient data.
    •  GA(LMP) – this field is computed using the LMP date on the 
    Patient Data Entry screen. To change this field:
    NOTE:  You can only change this field on the Fetal Growth Curve 
    Graph in single view.
    a. Move the Trackball to the field, which is left of the 
    graph. To select the field, press Set.
    The system displays a window with the GA weeks and 
    days.
    b.  To select each field, move the Trackball to the field and 
    press Set.
    c.  Type the correct weeks or days.
    d. Select OK.
    The system makes the following changes:
    •  GA (LMP) is now GA (GA) and shows the age you 
    entered.
    •  In the Patient Data section, the GA changes.
    •  In the Patient Data section, The EDD (LMP) changes to 
    EDD(GA) and shows an updated date, using the GA 
    you entered.
    The LMP is erased.
    •  FetusPos – type information about the fetus position.
    •  PLAC – type information about the placenta.
    To return from a graph to the scan display
    After viewing graphs, to return to the scan display, do one of the 
    following:
    •  On the graph display, select Exit.
    •  On the Touch Panel, select Graph Display. 
    						
    							OB/GYN
    9-72 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Fetal Growth Bar Graph
    The fetal growth bar graph shows current exam measurements 
    and the normal growth range based on the gestational age. It 
    shows all measurements on one graph.
    To view the Fetal Growth Bar Graph: 
    1. Press Measure.
    2. Select Graph.
    3. Select Bar.
     Figure 9-17. Fetal Growth Bar Graph 
    						
    							OB Graphs
    LOGIQ 5 Basic User Manual 9-73
    Direction 2300002-100 Rev. 2
    Fetal Growth Bar Graph (continued)
    •  The horizontal axis shows the gestational weeks. 
    •  The red vertical line shows the gestational age using the 
    patient data. 
    •  The blue dotted vertical line shows the ultrasound age using 
    the current measurements. 
    •  The yellow x shows the ultrasound age for each 
    measurement.
    •  The green rectangle shows the normal age range for the 
    measurement.
    You cannot do fetal trending or view multiple gestation data on 
    the bar graph. 
    						
    							OB/GYN
    9-74 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    OB-Multigestational
    Using other OB studies
    The LOGIQ 5 system includes measurements for the following 
    studies: USA, Europe, Tokyo, Osaka, and ASUM. The following 
    figures show the OB Touch Panel displays for the Tokyo and 
    Osaka studies and for the ASUM studies. For information about 
    how to change studies, refer to “Measurement and Analysis 
    (M&A) System Presets” on page 16-10. 
     Figure 9-18. OB Touch Panel: Tokyo and Osaka studies
    NOTE:  Tokyo and Osaka studies have a folder for JSUM 
    measurements. JSUM measurements include AC, BPD, CRL, 
    and FL. 
    						
    All GE manuals Comments (1)