Home > GE > Ultrasound System > GE Logiq P5 User Manual

GE Logiq P5 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE Logiq P5 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 878
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-31
    Direction 2300002-100 Rev. 2
    Removing items from the Touch Panel
    To remove items from the Touch Panel, you remove them from 
    the Measure & Study list.
    1. Move the Trackball to highlight the item in the Measure & 
    Study list and press Set. 
    2.  Select the X to the right of the list.
    The system removes the item from the Measure & Study list 
    and from the Touch Panel. The item is still listed in the 
    Available folders and measurements list. 
     Figure 7-18. Measurement & Analysis: Remove item from Touch Panel 
    						
    							General Measurements and Calculations
    7-32 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Removing items from the Touch Panel (continued)
    To remove an item from the Selection menu:
    1. Move the Trackball to the item in the Available folders and 
    measurements list.
    2.  To clear the check box for the item, move the Trackball to 
    the check box and press Set.
    The system removes the item from the Selection menu, the 
    Measure & Study list, and from the Touch Panel. It is also 
    not listed in the Summary Window. 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-33
    Direction 2300002-100 Rev. 2
    Setting up an automatic exam flow
    In some cases, related measurements are put in a 
    measurement folder. This allows you to logically organize 
    measurements. It also allows you to specify that the system 
    automatically start each measurement in a folder, one after the 
    other. This is the automatic sequence feature. To use this 
    feature:
    1.  In the Selection menu, select the folder that contains the 
    measurements you want.
    The system displays the folder and lists the measurements.
    2.  In the Folder section of the Measurement & Analysis screen, 
    select Auto sequence. For OB/GYN Vessel measurements, 
    Umbilical Doppler measurements are put in the Umbilical 
    measurement folder.
     Figure 7-19. Measurement & Analysis screen: Auto sequence 
    						
    							General Measurements and Calculations
    7-34 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Changing Measurements
    You can make changes to some of the measurements. For 
    example, Head Circumference can be measured with an ellipse, 
    a trace, or two distances. You can specify which measurement 
    type you want the system to use as the default. You specify the 
    measurement type by selecting the tool to use to make the 
    measurement.
    •  To change the tool used to make a measurement:
    In the Measurement section of the Measurement & Analysis 
    screen, select the desired tool from the Tool list. See 
    Figure 7-20. Select the arrow to display the drop-down list.
    NOTE:  If the Tool field is gray, it cannot be changed.
    After you choose the tool, this is what the system expects 
    when you scan and choose this measurement.
    NOTE:  The diagram to the right of the Tool list shows the measurement 
    type. In Figure 7-20, ellipse is selected and the diagram shows 
    an ellipse. 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-35
    Direction 2300002-100 Rev. 2
    Changing Measurements (continued)
     Figure 7-20. Measurement & Analysis screen: Change measurements 
    						
    							General Measurements and Calculations
    7-36 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Adding Folders and Measurements
    Adding a folder
    When you add a folder, it can be a study, or a measurement 
    folder that includes related measurements. 
    1.  In the Selection menu, select the study or folder where you 
    want to add the folder.
    2.  In the Measurement menu section, select Add folder.
    •  If you select Blank, the system adds a folder with a 
    name such as USERDEFS1. It is listed in the Selection 
    menu. See Figure 7-22.
    •  If you want to use an existing folder, select Insert, and 
    then select a folder from the list. The list includes all 
    folders defined for the current exam category and 
    selected mode. You can not edit this folder.
     Figure 7-21. Add folder Window
    3.  Select the user-defined folder in the Selection menu.
    The system displays the new folder in the Folder section of 
    the Measurement & Analysis screen.
    4.  To name the folder, move the Trackball to highlight the 
    Name field, press Set twice, and type the name.
    5.  To add measurements to the folder, See ‘Adding a user-
    defined measurement’ for more information. 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-37
    Direction 2300002-100 Rev. 2
    Adding a folder (continued)
     Figure 7-22. Measurement & Analysis: Add folder 
    						
    							General Measurements and Calculations
    7-38 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Adding a user-defined measurement
    You can create a user-defined measurement in a system-
    defined folder or in a folder you created.
    1.  In the Selection menu, select the study or folder where you 
    want to add the measurement.
    2.  In the Measurement menu section, select Add 
    measurement.
    The system displays the Add Measurement window. See 
    Figure 7-24. 
     Figure 7-23. Add Measurement window
    3.  Do one of the following: 
    •  If you want to create this measurement from a copy of 
    an existing measurement, select Use copy of, and then 
    select a measurement from the list. The list includes all 
    measurements defined for the current exam category 
    and selected mode.
    NOTE:  This only applies to OB and Cardiac. 
    •  If you want to use an exsiting formula, select Insert, and 
    then select a measurement from the list. The list 
    includes all measurements defined for the current exam 
    category and selected mode. You can not edt this 
    formula.
    •  If you want to create a blank new measurement, select 
    Blank. 
    						
    							Measurement and Calculation Setup
    LOGIQ 5 Basic User Manual 7-39
    Direction 2300002-100 Rev. 2
    Adding a user-defined measurement (continued)
    4. Select OK.
    •  If you created a blank measurement, the system adds a 
    measurement with a name such as USERDEFM3. 
    •  If you created a measurement from a copy of an existing 
    measurement, the system lists the measurement and its 
    parameters in the Measurement section.
    5.  When you create a new measurement, the measurement 
    name is automatically highlighted. Type a name for the new 
    measurement. You can change the name of a measurement 
    you created from a copy.
     Figure 7-24. Measurement & Analysis: Add measurement 
    						
    							General Measurements and Calculations
    7-40 LOGIQ 5 Basic User Manual
    Direction 2300002-100 Rev. 2
    Adding a user-defined measurement (continued)
    Defining
    measurement
    parametersAfter you add a measurement, you can add parameters. You 
    may also want to change parameters if you copied an existing 
    measurement. See ‘Changing or adding measurement 
    parameters’ for more information.
    Changing or adding measurement parameters
    You can make changes to measurement parameters and you 
    can add measurement parameters.
    Changing
    measurement
    parametersTo change a measurement parameter:
    1.  In the Selection menu, select the measurement.
    2.  To change the name of the Parameter, move the Trackball 
    to the parameter name and press Set twice. Type a name 
    for the parameter.
    For a description of other measurement changes, See 
    ‘Changing Measurements’ for more information. 
    						
    All GE manuals Comments (1)