Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-31 Direction 2300002-100 Rev. 2 Removing items from the Touch Panel To remove items from the Touch Panel, you remove them from the Measure & Study list. 1. Move the Trackball to highlight the item in the Measure & Study list and press Set. 2. Select the X to the right of the list. The system removes the item from the Measure & Study list and from the Touch Panel. The item is still listed in the Available folders and measurements list. Figure 7-18. Measurement & Analysis: Remove item from Touch Panel
General Measurements and Calculations 7-32 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Removing items from the Touch Panel (continued) To remove an item from the Selection menu: 1. Move the Trackball to the item in the Available folders and measurements list. 2. To clear the check box for the item, move the Trackball to the check box and press Set. The system removes the item from the Selection menu, the Measure & Study list, and from the Touch Panel. It is also not listed in the Summary Window.
Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-33 Direction 2300002-100 Rev. 2 Setting up an automatic exam flow In some cases, related measurements are put in a measurement folder. This allows you to logically organize measurements. It also allows you to specify that the system automatically start each measurement in a folder, one after the other. This is the automatic sequence feature. To use this feature: 1. In the Selection menu, select the folder that contains the measurements you want. The system displays the folder and lists the measurements. 2. In the Folder section of the Measurement & Analysis screen, select Auto sequence. For OB/GYN Vessel measurements, Umbilical Doppler measurements are put in the Umbilical measurement folder. Figure 7-19. Measurement & Analysis screen: Auto sequence
General Measurements and Calculations 7-34 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Changing Measurements You can make changes to some of the measurements. For example, Head Circumference can be measured with an ellipse, a trace, or two distances. You can specify which measurement type you want the system to use as the default. You specify the measurement type by selecting the tool to use to make the measurement. • To change the tool used to make a measurement: In the Measurement section of the Measurement & Analysis screen, select the desired tool from the Tool list. See Figure 7-20. Select the arrow to display the drop-down list. NOTE: If the Tool field is gray, it cannot be changed. After you choose the tool, this is what the system expects when you scan and choose this measurement. NOTE: The diagram to the right of the Tool list shows the measurement type. In Figure 7-20, ellipse is selected and the diagram shows an ellipse.
Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-35 Direction 2300002-100 Rev. 2 Changing Measurements (continued) Figure 7-20. Measurement & Analysis screen: Change measurements
General Measurements and Calculations 7-36 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Adding Folders and Measurements Adding a folder When you add a folder, it can be a study, or a measurement folder that includes related measurements. 1. In the Selection menu, select the study or folder where you want to add the folder. 2. In the Measurement menu section, select Add folder. • If you select Blank, the system adds a folder with a name such as USERDEFS1. It is listed in the Selection menu. See Figure 7-22. • If you want to use an existing folder, select Insert, and then select a folder from the list. The list includes all folders defined for the current exam category and selected mode. You can not edit this folder. Figure 7-21. Add folder Window 3. Select the user-defined folder in the Selection menu. The system displays the new folder in the Folder section of the Measurement & Analysis screen. 4. To name the folder, move the Trackball to highlight the Name field, press Set twice, and type the name. 5. To add measurements to the folder, See ‘Adding a user- defined measurement’ for more information.
Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-37 Direction 2300002-100 Rev. 2 Adding a folder (continued) Figure 7-22. Measurement & Analysis: Add folder
General Measurements and Calculations 7-38 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Adding a user-defined measurement You can create a user-defined measurement in a system- defined folder or in a folder you created. 1. In the Selection menu, select the study or folder where you want to add the measurement. 2. In the Measurement menu section, select Add measurement. The system displays the Add Measurement window. See Figure 7-24. Figure 7-23. Add Measurement window 3. Do one of the following: • If you want to create this measurement from a copy of an existing measurement, select Use copy of, and then select a measurement from the list. The list includes all measurements defined for the current exam category and selected mode. NOTE: This only applies to OB and Cardiac. • If you want to use an exsiting formula, select Insert, and then select a measurement from the list. The list includes all measurements defined for the current exam category and selected mode. You can not edt this formula. • If you want to create a blank new measurement, select Blank.
Measurement and Calculation Setup LOGIQ 5 Basic User Manual 7-39 Direction 2300002-100 Rev. 2 Adding a user-defined measurement (continued) 4. Select OK. • If you created a blank measurement, the system adds a measurement with a name such as USERDEFM3. • If you created a measurement from a copy of an existing measurement, the system lists the measurement and its parameters in the Measurement section. 5. When you create a new measurement, the measurement name is automatically highlighted. Type a name for the new measurement. You can change the name of a measurement you created from a copy. Figure 7-24. Measurement & Analysis: Add measurement
General Measurements and Calculations 7-40 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Adding a user-defined measurement (continued) Defining measurement parametersAfter you add a measurement, you can add parameters. You may also want to change parameters if you copied an existing measurement. See ‘Changing or adding measurement parameters’ for more information. Changing or adding measurement parameters You can make changes to measurement parameters and you can add measurement parameters. Changing measurement parametersTo change a measurement parameter: 1. In the Selection menu, select the measurement. 2. To change the name of the Parameter, move the Trackball to the parameter name and press Set twice. Type a name for the parameter. For a description of other measurement changes, See ‘Changing Measurements’ for more information.